(4) Additional Considerat ions. The following are items to consider in an icing certification program. They are not intended to be all-inclusive, and the possibility of widely differing characteristics and critical areas among various rotorcraft in icing should be considered.
(i) The rotorcraft should be show n by analysis and confirmed by either simulated or natural icing tests to be capable of holding for 30 minutes in the design conditions of the continuous maximum icing envelope at the most critical weight, CG, and altitude with a fully functional ice protection system.
(ii) A single ice protection system and power source may be considered acceptable provided that after any single failure of the ice protection system, the rotorcraft can be shown by analysis and/or test to be capable of safe operation (no hazard) for 15 minutes following failure recognition in the continuous icing envelope used as the basis for certification within the same icing limits used for the 30-minute hold criteria. During this 15-minute period the rotorcraft may exhibit degraded characteristics. Pilot controllable operating limitations such as airspeed may be used to satisfy this continued safe flight criteria. For purposes of determining performance and handling qualities degradation, ice protection system failure need not be considered to occur simultaneously with engine failure unless ice protection system operation is dependent upon engine operation.
(iii) Although current airborne weather radar technology systems may be useful in avoiding potential icing conditions by detecting precipitation, the use of weather radar is not an FAA/AUTHORITY requirement for icing certification.
(iv) Section 27.1419(e) says there must be a means to advise the crew when the rotorcraft is in icing conditions in order that the system may be activated.
(v) No autorotational performance data is required for rotorcraft which have Category A powerplant installations. The rotorcraft must be capable of full autorotational landings with the ice protection system operating (§ 27.143a(2)(vi).
Autorotational entry, steady state, and flare entry flying qualities and performance should be evaluated with the ice load to be expected with the deice system operating and with the ice load to be expected 15 minutes after failure of the system. Since the en route performance can vary as the ice protection system operates, a mean value of cyclic torque is acceptable provided, at no time the power required drops below that required for level flight. The rotorcraft is assumed to be clear of ice prior to takeoff, and, therefore, the takeoff performance is not degraded. The landing performance can be based on the in-flight assessment of overall performance degradation. Items such as fuel burns can be used as part of the in-flight performance degradation determination.
Regardless of the methods used to determine performance degradation, they must be easily used by the crew. The hover performance should be addressed for the termination of a flight after an icing encounter. The engines should be protected from the adverse effects of ice. When ice does accumulate on the inlets, screens, etc., it
Page F - 88 must be accounted for in performance, engine operating characteristics, and inlet distortion.
(vi) The handling qualitie s of the rotorcraft must be substantiated if ice can accumulate on any surface. When ice can accumulate on unprotected surfaces, the rotorcraft must exhibit satisfactory IFR handling qualities. In addition, following the failure of the deice system, the rotorcraft must be safely controllable for 15 minutes, i.e., the rotorcraft must be free from excessive and rapid divergence. Artificial ice shapes may be acceptable for acquisition of flight test data necessary for handling qualities and performance evaluations and demonstrations.
(vii) Items such as fuel tank vent s, cooling vents, antennas, etc., should be substantiated for maximum icing effects.
(viii) The ice protection system shoul d be sufficiently reliable to perform its intended function in accordance with the requirements of § 27.1309. These requirements may in some instances be met by the use of sound engineering judgment during design and compliance demonstrations. In many instances, use of good design practices, failure modes and effects analysis, and similarity analyses combined with good judgment will be adequate. In some instances the need for reliability analyses may be desirable. Additional information pertaining to reliability is contained in paragraph AC 27.1309 (§ 27.1309).
(ix) The subject of lightning shoul d be addressed. The criteria applied on rotorcraft with ice protection systems are that “the rotorcraft should be protected in such a manner to minimize lightning risk.” The general rules of § 27.1309(a), (b), and (c) are applicable to ensure adequate lightning protection. (Amendment 27-21, November 6, 1984, added lightning protection requirements in § 27.610.)
(x) Ice protection of pitot-static sources, windshields, inlets, exposed control linkages, etc., should be considered.
(xi) The impact of ice protecti on system failure, complete and partial, and achieving adequate warning thereof should be assessed.
(xii) The impact of delayed application of ice protection systems should be assessed. Hazardous conditions should not be apparent. Any rotorcraft characteristic changes resulting should be covered in cautionary material in the rotorcraft flight manual.
(xiii) Possible droop stop malf unction with ice accumulation and its potential hazard to the rotorcraft, its occupants, and ground personnel should be assessed.
Page F - 89
(xiv) Possible ice shedding hazards to ground personnel or equipment in proximity to turning rotors following flight in icing conditions should be given consideration.
(5) Flight Manual . Areas of the flight manual which may require input are:
(i) Operating limitations incl uding approved types of operation and prohibiting operation in freezing rain or freezing drizzle conditions. Avoidance procedures may also be useful.
(ii) Normal Operating Procedures . Information on the ice detection means or system and ice protection system and their capabilities.
(iii) Emergency Operating Procedur es. Operating procedures containing essential information particularly with system failure.
(iv) Caution Notes. These c aution notes should advise or address:
(A) Against inducing asymmetric shedding with rapid control inputs or rotor speed changes, except possibly as a last resort. Rotor speed changes appear to be more effective than control inputs in removing ice from the rotor blades of some rotorcraft.
(B) Loss in range, climb rate, and hover capability following prolonged operation in icing.
(C) The need for clean blade surfaces and use of approved cleaning solvents or ground deicing/anti-icing agents prior to start of rotors turning.
(D) Changes in autorotational characteristics resulting from ice formations.
(E) Although the rotorcraft has been certificated for flight in supercooled clouds and falling and blowing snow, flight in other conditions such as freezing rain, freezing drizzle, sleet, hail, and combinations of these conditions with supercooled clouds must be avoided.
(F) The potential hazards to ground personnel, passengers deplaning, and equipment in proximity to turning rotors following flight in icing conditions.
d. Icing References .
(1) FAA Technical Report ADS-4, En gineering Summary of Airframe Icing Technical Data, December 1963.
Page F - 90
(2) Advisory Circular 20-73, Aircraft Ice Protection, 21 April 71.
(3) Advisory Circular 91-51, Airpl ane Deice and Anti-ice Systems, 9/15/77.
(4) FAA Report RD-77-76, Engineering Su mmary of Powerplant Icing Technical Data, July 1977.
(5) United States Army Aviation Engineering Flight Activity Reports:
(i) Natural Icing Tests, UH-1 H Helicopter, Final Report, June 1974, USAASTA Project No. 74-31.
(ii) Artificial Icing Tests, UH- 1H Helicopter, Part I, Final Report, January 1974, USAASTA Project No. 73-04-4.
(iii) Artificial Icing Tests, UH- 1H Helicopter, Part II, Heated Glass Windshield, Final Report, USAASTA Project No. 73-04-4.
(iv) Artificial Icing Tests, Lockheed Advanced Ice Protection System Installed on a UH-1H Helicopter, Final Report, June 1975, USAAEFA Project No. 74-13.
(v) Artificial and Natural Icing Te sts for Qualification of the UH-1H, Kit A Aircraft, Letter Report, USAAEFA Project No. 78-21-1.
(vi) Microphysical Properties of Artificial and Natural Clouds and Their Effects on UH-1H Helicopter Icing, Report USAAEFA Project No. 78-21-2.
(vii) Helicopter Icing Spray System (HISS) Nozzle Improvement Evaluation, Final Report, September 1981, USAAEFA Project No. 79-002-2.
(viii) Artificial and Natural Ici ng Tests of the YCH-4TD, Final Report, May 1981, USAAEFA Project No. 79-07.
(ix) Limited Artificial Icing Test s of the OV-ID, Letter Report, July 1981, USAAEFA Project No. 80-16, (Limited Distribution).
(x) JUH-IH Ice Phobic Coating Test s, Final Report, July 1980, USAAEFA Project No. 79-02.
(xi) Artificial and Natural Ici ng Tests, Production UH-60A Helicopter, Final Report, June 1980, USAAEFA Project No. 79-19.
(xii) Helicopter Icing Spray Syst em (HISS) Evaluation and Improvements, Letter Report, June 1981, USAAEFA Project No. 80-04.
Page F - 91
(xiii) Artificial Icing Test of CH-47C Helicopter with Fiberglass Rotor Blades, Final Report, July 1979, USAAEFA Project No. 78-18.
(xiv) Limited Artificial and Natu ral Icing Tests, Production UH-60A Helicopter (Reevaluation), Final Report, August 1981, USAAEFA Project No. 80-14.
(6) Further Icing Experiments on an Unheated Nonrotating Cylinder, National Research Council, Canada Report LTR-LT-105, dated November 1979, by J.R. Stallabrass and P.F. Hearty.
(7) Ludlam, F.H., Heat Economy of a Rimed Cylinder, Quarterly Journal, Royal Meteorological Society, Vol. 77, 1951.
(8) U.S. Army AMRDL Reports:
(i) USAAMRDL TR 73-38, Ice Pr otection Investigation For Advanced Rotary Wing Aircraft, J.B. Werner, August 1973, AD 7711182.
(ii) Werner, J.B., The Developm ent of an Advanced Anti-Icing/Deicing Capability for U.S. Army Helicopters, Volume 1, Design Criteria and Technology Considerations, USAAMRDL - TR-75-34A, Eustis Directorate, U.S. Army Air Mobility R&D Laboratory, November 1975, AD A019044.
(iii) Werner, J.B., The Developm ent of an Advanced Anti-Icing/Deicing Capability for U.S. Army Helicopters, Volume 2, Ice Protection System Application to the UH-1H Helicopter, USAAMRDL - TR-75-34B, Eustis Directorate, U.S. Army Air Mobility Research and Development Laboratory, November 1975, AD A019049.
(iv) USAAMRDL-TR-76-32, Ottawa Spray Rig Tests of an Ice Protection System Applied to the UH-1H Helicopter, November 1976, AD A0034458.
(v) USARTL-TR-78-48, Icing Test s of a UH-1H Helicopter with an Electrothermal Ice Protection System Under Simulated and Natural Icing Conditions, April 1979.
(vi) USAAMRDL-TR77-36, Final Report, Natural Icing Flights and Additional Simulated Icing Tests of a UH-IH Helicopter Incorporating an Electrothermal Ice Protection System, July 1978, AD A059704.
(9) Technical Feasibility Test of Ic e Phobic Coatings for Rain Erosion in Simulated Flight Conditions, U.S. Army Test and Evaluation Command, Final Report, 4-AI-192-IPS-001, August 1980.
(10) Technical Feasibility Test of Ice Phobic Coatings in Simulated Icing Flight Conditions, U.S. Army TECOM, Final Report, 4-CO-160-000-048, September 1980.
Page F - 92
(11) Aircraft Icing, NASA Confer ence Publication 2086, FAA-RD-78-109, July 1978.
(12) Helicopter Icing Review, FAA Technical Center, Final Report, FAA-CT-80-210, September 1980.
(13) National Icing Facilities Requi rements Investigation, Final Report, FAA Technical Center, FAA-CT-81-35, March 1981.
(14) Aircraft Icing, AGARD Adviso ry Report No. 127, November 1978.
(15) Rotorcraft Icing - Review and Prospects, AGARD Advisory Report, AR-166, September 1981.
(16) Advisory Circular 20-117, Ha zards Following Ground Deicing and Ground Operations in Conditions Conducive to Aircraft Icing, Dec. 17, 1982.
(17) Olson, W., Experimental Co mparison of Icing Cloud Instruments, January 1983, NASA TM 83340.
(18) JUH-1H Redesign ed Pneumatic Boot Deicing System Flight Test Evaluation. Hayworth, L., Graham, M., August 1987. USAAEFA Edwards AFB, California. Project No. 83-13.
(19) An Appraisal of the Single Ro tating Cylinder Method of Liquid Water Content Measurement, National Research Council Canada Report LTR-LT-92, dated November 1978, by J.R. Stallabrass.
40 - 30 - 20 - 10 - -10 + 2000 4000 6000 8000 10,000
PRESSURE ALTITUDE - FT FIGURE AC 27.1419-1 CONTINUOUS ICING - TEMPERATURE VS ALTITUDE LIMITS Figures 27.1419-1 through 4 represent the approach to a 10,000-foot altitude limit. See Paragraph b(5)(ll) for a discussion on this approach.
Page F - 93
40 - 30 — AMBIENT TEMPERATURE - DEG F 20 10
- 10 2000 4000 6000 8000 10,000
PRESSURE ALTITUDE - FT FIGURE AC 27.1419-2 INTERMITTENTTCING - TEMPERATURE VS ALTITUDE LIMITS Figures AC 27.1419-1 through 4 represent the approach to a 10,000-foot altitude limit.
See Paragraph b(5)(ili) for a discussion on this approach.
Page F - 94
1.0 - LIQUID WATER CONTENT - GRAMS/CUBIC METER 0.8 SEA LEVEL TO 10,000 FT PRESSURE ALTITUDE AMBIENT TEMP °F *70 20 30 40 5
MEAN EFFECTIVE DROP DIAMETER - MICRONS FIGURE 27.1419-3 CONTINUOUS ICING-LIQUID WATER CONTENT VS. DROP DIAMETER Figures AC 27.1419-1 through 4 represent one approach to a 10,000-foot altitude limit.
See Paragraph b(5)(iii) for a discussion of this approach.
Page F - 95
2.0 SEA LEVEL TO 10,000 FT PRESSURE ALTITUDE LIQUID WATER CONTENT - GRAMS/CUBIC METER 1.6
AMBIENT TEMP 32 °F
1.2 14 °F
0.8 Q°F
0.4 10 20 30 40 50
MEAN EFFECTIVE DROP DIAMETER - MICRONS FIGURE AC 27. 1419-4. INTERMITTENT ICING-LIQUID
WATER CONTENT VS DROP DIAMETER Figures AC 27.1419-1 through 4 represent one approach to a 10,000-foot altitude limit.
See paragraph b(5)(iii) for a discussion of this approach.
Page F - 96
Page F - 97
SUBPART F - EQUIPMENT
MISCELLANEOUS EQUIPMENT
AC 27.1435. § 27.1435 HYDRAULIC SYSTEMS .
a. References . The following sections of Part 27 are either incorporated in the provisions of § 27.1435 or are otherwise applicable to hydraulic system design:
§§ 27.695, 27.861, 27.863, 27.1183, 27.1185, 27.1189, 27.1309, and 27.1322.
b. System Design . It is assumed that the hydraulic system will be utilized to operate utility systems and the primary control system of the rotorcraft.
(1) Section 27.1309(a) and (b) provid es for functioning reliably under any foreseeable operating condition and prevention of hazards after any malfunction or failure.
(2) The substantiating data should in clude a failure analysis that considers every possible system component failure, such as (but not limited to) ruptured lines, pump failure, regulator failure, ruptured seals, clogged filters, broken pilot valve connections, and so forth. Also, consideration of the specific requirements of § 27.1435 should be included.
(3) If the rotorcraft cannot be safely operated without the hydraulic system, the requirements of § 27.1309(a) and (b) are met by dual independent hydraulic systems.
From the reservoir, hydraulic pump, regulator, connecting tubing, and hoses through the actuators, there must be no commonality in the fluid-containing components. A break in one system should not result in fluid loss in the remaining systems. The pumps should be separated as far as practicable; i.e., on opposite sides of the rotor drive transmission, on separate engines, or one pump on an engine and the other on the rotor drive transmission. The tubing and hoses should also be routed with as much physical separation as practicable. The purpose of this separation is to prevent total loss of the hydraulic systems in the event of a malfunction such as fire or rotor burst wherein one projectile could disable both systems.
(4) Dual actuators must be designed to ensure that any single failure, such as a cracked housing, broken interconnecting input, or output link, does not result in loss of total hydraulic system function.
(5) If installed, the pressure-indicati ng system is normally included as a dial, vertical scale, or digital indicator. The indicator should enable the crew to detect pressure trends. Paragraph AC 27.1322 concerns § 29.1322 regarding proper colors for annunciators if used to supplement the indicating system.
Page F - 98
(6) A combination of analysis and tests should be included in the substantiating data file to show compliance with the provisions of § 27.1435.
(7) Extra caution should be exercised to ensure that control input forces at the mechanical connection to the actuator pilot valves do not exceed their intended value.
Consideration should be given to the most adverse tolerance buildup in parts fabrication and control system rigging.
(8) The substantiating data should show that the hydraulic components will perform their intended function reliably under the most adverse continuous and short-time environmental conditions to which they are exposed. These variables include but are not limited to temperature, humidity, vibration, altitude, and shock.
Paragraph AC 27.1309b(2)(i) contains a method of temperature correction to cover the entire operating temperature envelope being certified.
(9) The system component strength must be sufficient for its material fatigue life to exceed the number of cycles imposed by pump ripple pressure.
c. Installation Precautions and Fire Protection .
(1) All components and t ubing routed through fire zones may be designed to comply with the fire protection requirements of §§ 29.1183, 29.1185, and 29.1189. As an alternative, a fireproof shield may be used around the component to be protected.
The component should be sufficiently protected to assure fluid leakage will not occur and fuel the fire.
(2) All hydraulic lines should be suffici ently isolated from the engine, bleed air lines, environmental control unit, oil cooler, or other heat source to ensure expected line life.
(3) If flammable hydraulic fluid is used, the hydraulic components should be isolated from ignition sources to ensure that failure of any of the hydraulic components will not result in a fire or explosion. In the case of electrical ignition sources in the proximity of hydraulic components, the electrical equipment should be hermetically sealed or otherwise substantiated as not being an ignition source (reference paragraph AC 27.1309b(1)(i)).
(4) The installation detail should be thoroughly reviewed for adequacy of line clamping and clearance from sharp edges. As much physical separation as possible should be provided between hydraulic lines and electrical cables.
(5) While the control system is being moved from stop to stop, observation should be made to determine that hose flexing and tube bending is minimized.
d. Testing .