FIGURE 11.7A-Wire used in aircraft installations-continued.

Standard Specification Conduetor Insulation Voltage rate temp. rating Conductor Remarka MS-18000 Mil-W-22759 Silver-coated copper Mineral reinforced TFE 600 V. 200° C. Similar to MS-17411 and MS- 17412 with thinner wall and less abrasion resistant.

MS-18001 Mil-W-22759 Nickel-coated copper Mineral reinforced TFE 600 V. 260° C. Same as MS-1800.

MS-18032 Mil-W-22759 Silver-coated copper Fused laminated TFE 600 V. 200° C. Hook-up similar to MS-21985 and MS-21986 with thinner wall and less abrasion registance.

MS-18033 Mil-W-22759 Nickel-coated copper Fused laminated TFE 600 V. 260° C. Same as MS-18032 Laminated wall is uniform in cross section.

MS-18104 Mil-W-22759 Silver-coated copper Extruded TFE polyimide 600 V. 200° C. Similar to MS-18113 and MS- coated 18114 but thinner wall and higher abrasion resistance.

MS-18105 Mil-W-22759 Nickel-coated copper Extruded TFE polyimide 600 V. 260° C. Same as MS-18104.

coated MS-18113 Mil-W-22759 Silver-coated copper Extraded TFE 1,000 V. 200° C. Similar to MS-21985 and MS- 21986 but bigher voltage rate.

MS-18114 Mil-W-22759 Nickel-coated copper Extruded TFE 1,000 V. 260° C. Same as MS-18113.

MS-21985 Mil-W-22759 Silver-coated copper Extruded TFE 600 V. 200° C. Hook-up.

MS-21986 Mil-W-22759 Nickel-coated copper Extruded TFE 600 V. 260° C. Hook-up.

MS-27125 Mil-W-25038 Nickel-clad copper (27% Asbestos, glass, TFE 600 V. 260° C. Fire resistant. Moisture, abranickel) sion and fluid resistant where ambient temp. below 550° C.

None Mil-W-16878 Silver or nickel-coated Extraded TFE 1,000 V. 200° C. Hook-up-similar to MS-18113 Type EE copper or and MS-18114.

260° C.

M81044/1A Mil-W- Silver-plated copper Crosslinked extruded 600 V. - 65 to Aerospace electric systems 81044A polyalkene + 135 (General purpose aircraft (AS) wiring) M81044/2A Tin-coated copper normal weight M81044/3A Silver-plated copper Aerospace electric systems (General electronie wiring) 1973

Page 227OCROpen in PDF

M81044/4A Tin-plated copper Internal wiring of meters, panels, and electrical and electronic equipment.

M81044/5 Silver-plated copper Crosslinked extruded - 65 to Aerospace electric systems polyalkene + 150 (General purpose aircraft M81044/6 Tin-coated copper wiring) normal weight M81044/7 Silver-plated high strength copper alloy M81044/8 Silver-plated copper Aerospace electric systems (General purpose aircraft M81044/9 Tin-coated copper wiring) M81044/10 Silver-plated high medium weight strength copper alloy M81044/11 Silver-plated copper Aerospace electric systems (General electronic wiring) M81044/12 Tin-coated copper Internal wiring of meters, M81044/13 Silver-plated high panels, and electrical and elecstrength copper alloy tronic equipment.

M81381/1 Mil-W--81881 Silver-coated copper Polyimide/FEP film 600 V. -65 to Aerospace electric systems (AS) + 200 (General electronic wiring) Internal wiring of meters, M81881/2 Nickel-coated copper panels, and electrical and electronic equipment, M81381/8 Silver-coated copper Aerospace electric systems (General purpose aircraft M81881/4 Nickel-coated copper wiring) medium weight

Page 228 · 166OCROpen in PDF

of the table on the diagonal line which is numbered 20 amperes; (4) Follow this line until the pointer intersects the diagonal line marked "curve 2;" and (5) Drop pointer straight downward to the bottom of the chart and we are between the number 16 and 18. As the results are again between sizes, select the larger No. 16 wire. This is the smallest size wire acceptable for carrying 20-ampere current in a single wire in free air without overheating.

f. Compare the wire sizes selected. Use & cable no smaller than No. 8 in order to satisfy requirement (a) and no smaller than a No. 16 in order to satisfy requirement (b). Since we must meet both requirements, select the larger No. 8.

g. In this particular instance, the voltagedrop requirement was more critical because it required a larger size than the heat-dissipation requirement. This is usually true when a relatively light current is carried over a relatively long distance. However, when a short wire and/or a heavy current is required, the heatdissipation capabilities of the wire may become the critical factor and may dictate the size of the wire to be used.

h. The tabulation referenced in paragraph 442a shows several values of voltage drop which is allowable for various systems and conditions when selecting wire for use from the bus to the equipment. Additionally, the voltage drop permissible in wires from the generator to the bus and from the battery to the bus will vary with the regulated voltage of the system i.e., nominal 14 V., 28 V., 116 V., etc.

445. SPLICES IN ELECTRIC WIRE, Splicing of electric wire should be kept to a minimum and avoided entirelv in locations subiect to extreme AC 43.13-1A 1972 dle may be spliced provided the completed splice is located so it can be periodically inspected. Stagger splices (see figure 11.8) so the bundle does not become excessively enlarged.

Many types of aircraft splice connectors are available for use when splicing individual wires. Use of the self-insulated splice connector is preferred; however, a noninsulated splice connector may be used provided the splice is covered with plastic sleeving which is secured at both ends. Solder splices may be used; however, they are particularly brittle and not recommended.

446. OPEN WIRING. Electric wiring is often installed in aircraft without special enclosing means. This practice is known as open wiring and offers the advantages of ease of maintenance and reduced weight.

a. Wire Bundles. To simplify maintenance and to minimize the damage that may result from a single fault, limit the number of wires in the run. Shielded wire, ignition wire, and wires which are not protected by a circuit breaker or fuse usually are routed separately. Avoid bending radii less than 10 times the outer diameter of the bundle to prevent excessive stresses on the wire insulation.

b. Insulating Tubing. Soft insulating tubing (spaghetti) cannot be considered as mechanical protection against external abrasion of wire, since at best it provides only a delaying action.

Use conduit or ducting when mechanical protection is needed.

c. Clamping of Wire Bundles. Use clamps lined with nonmetallic material to support the wire bundle along the run. Tying may be used between clamps, but should not be considered as a substitute for adequate clamping. Adhe-

Page 229OCROpen in PDF

AC 43.13-1A Page 167 1972 therefore are not acceptable as a clamping means.

d. Separation from Flammable Fluid Lines. An arcing fault between an electric wire and a MS 21919 metallic flammable fluid line may puncture the CABLE CLAMP line and result in a serious fire. Consequently, EQUIVALENT OR make every effort to avoid this hazard by physical separation of the wire from lines or equipment containing oil, fuel, hydraulic fluid, or alcohol. When separation is impractical, locate the electric wire above the flammable fluid line and securely clamp to the structure. In no case, should a wire be supported by a flammable CLEARANCE fluid line. 14" MINIMUM

447. HEAT PRECAUTIONS. Separate wires from high temperature equipment, such as resistors, exhaust stacks, heating ducts, etc., to prevent insulation breakdown. Insulate wires that must run through hot areas with a high temperature ANGLE BRACKET WITH insulation material such as asbestos, fiberglas, TWO POINT FASTENING or teflon. Avoid high temperature areas when using cables having soft plastic insulation such as polyethylene because these materials are FIGURE 11.9--Cable clamp at bulkhead hole.

subject to deterioration and deformation at elevated temperatures. Many coaxial cables have this type of insulation. - WIRES LESS THAN 1/d

INCH FROM HOLE EDGE

448. PROTECTION AGAINST CHAFING. Protect wire and wire groups against chafing or abrasion as damaged insulation may result in short circuits, malfunctions, or inoperative equip- GROMMET ment. Support wire bundles using MS-21919 cable clamps as indicated in figure 11.9. When clamped in position, if there is less than 1/4- inch clearance between a bulkhead cutout and the wire bundle, install a suitable grommet as indicated in figure 11.10. The grommet may be cut at 45° angle to facilitate installation provided it is cemented in place and the slot is lo-

Page 230 · 188OCROpen in PDF

however, the following basic principles should be practiced:

o. Make sure all cutting tools used for stripping are sharp.

b. When using special wire stripping tools, adjust the tool to avoid nicking, cutting, or otherwise damaging the strands.

c. Damage to wires should not exceed the limits specified in figure 11.11.

FIGURE 11.11.-Allowable nicked or broken strands.

Wire size Nicked or broken strands Copper AN #22-#12 None #10 2 #8 -#4 14 #2 -#0 12 Aluminum All Sizes None NoTE: Longitudinal scratches in copper wire are not considered cause for rejection or rework.

450. TERMINALS, Terminals are attached to the ends of electric wires to facilitate connection of the wires to terminal strips or items of equipment. The tensile strength of the wire to terminal joint should be at least equivalent to the tensile strength of the wire itself, and its resistance negligible relative to the normal resistance of the wire. Terminals specifically designed for use with the standard sizes of aircraft wire are available through normal supply channels. Haphazard choice of commercial terminals may lead to overheated joints, vibration tailures, and corrosion difficulties.

a. Solder Terminals. For most applications, soldered terminals have been replaced by solderless terminals. The solder process has dis- AC 43.13-1A 1972 solder and become more susceptible to breakage due to vibration.

(5) The wire insulation may be charred during the soldering process.

b. Solderless Terminals. The terminal manufacturer will normally provide a special crimping or swaging tool for joining the solderless terminal to the electric wire. Aluminum wire presents special difficulty in that each individual strand is insulated by an oxide coating.

This oxide coating must be broken down in the crimping process and some method employed to prevent its reforming. In all cases, follow the terminal manufacturer's instructions when installing solderless terminals.

451. ATTACHMENT OF TERMINALS TO STUDS.

Electrical equipment malfunction has frequently been traced to poor terminal connections at terminal boards. Loose, dirty, or corroded contact surfaces will produce localized heating which may ignite nearby combustible materials or overheat adjacent wire insulation to the smoking point.

452. BONDING JUMPER INSTALLATIONS. Make bonding jumpers as short as practicable, and install in such manner that the resistance of each connection does not exceed .003 ohm. The jumper must not interfere with the operation of movable aircraft elements, such as surface controls, nor should normal movement of these elements result in damage to the bonding

a. Bonding Connections. To assure a lowresistance connection, remove nonconducting finishes; such as paint and anodizing films, from the attachment surface to be contacted by the bonding terminal. Do not ground electric wirina dirantle to mamacium nasta

Page 231OCROpen in PDF

AC 43.13-1A Page 189 1972 FIGURE 11.12.--Stud bonding or grounding to flat surface.

SCREW OR BOLT WASHER A

LOCKWASHER E

• STRUCTURE

WASHER B WASHER C

PLAIN NUT

WASHER D

TERMINAL (LIMIT TO 4) LOCKNUT

LOCKWASHER F Aluminum Terminal and Jumper Struoture Sorew or Bolt and Look nut Plain Washer Woeher Washer C&D Look washer Look washer Aluminum Alloya Cad. Plated Cad. Aluminam Aluminum Cad. Cad.

Steel Plated Alloy Alloy Plated Plated Steel Steel Steel Magnesium Cad. Plated Cad. Magnesium Magnesium Cad. Cad.

Alloye Steel Plated Alloy Alloy Plated Plated Steel Steel Steel Steel, Cadmium Cad. Plated Cad. None None Cad. Cad.

Plated Steel Plated Plated Plated Steel Steel Steel Steel, Corrosion Corrosion Cad. None None Cor. Cad.

Resisting Resisting Plated Resist Plated Steel ¡ Steel Steel Steel Tinned Copper Terminal and Jumper Aluminum Alloys Cad. Plated Cad. Aluminum Aluminum Cad. Cad. Cad.

Rtaal Dlarat A 1100 Platad plate Platad

Page 232OCROpen in PDF

Page 190 AC 43.13-1A 1973 FIGURE 11.18.-Plate nut bonding or grounding to flat surface.

LOCKWASHER

SCREW OR BOLT WASHER A - LIMITED TO 4

WASHER B

RIVET NUT PLATE Aluminum Terminal and Jumper Struoture Screw or Bolt and Nut plato Rivet Lookwashor Washer & Washer & Aluminum Alloys Cad. Plated Steel Aluminum Alloy Cadmium Cad. plated None Plated Steel steel or alumiaom Magnesium Alloya Cad. Plated Steel Aluminum Alloy Cadmium Cad. plated None or Plated Steel steel or Magnesium aluminum alloy Steel, Cadmium Cad. Plated Steel Cor. Beslet. Steel Cadmium Cad. plated None plated Plated Steel steel or aluminum Steel, Corrosion Corrosion Resist. Cor. Resist. Steel Cadmium Cad. plated Cadmium Resisting Steel or Cad. Plated Steel steel or plated Plated Steel aluminum steel Tinned Copper Terminal and Jumper Aluminum Alloys Cad. Plated Steel Aluminum Alloy Cadmium Cad. plated Aluminam Plated Steal 1 ateal

Page 233OCROpen in PDF

AC 43.13-1A Page 191 1972 FIGURE 11.14.-Bolt and nut bonding or grounding to flat surface.

- SCREW OR BOLT

WASHER A

WASHER B

LOCKWASHER

TERMINAL LIMITED TO 4

LOCKNUT WASHER C Aluminum Terminal and Jumper Etruoture Bores or Bolt and Hut plate Lookraaher Washer 1 Washer B Washer O Alaminum Alloy Cad. Plated Steel Cad. Plated Steel Cad. plated steel None Cad. plated or aluminum steel or aluminum Magnesium Alloy Cad. Plated Steel Cad. Plated Steel Magnesfum Alloy None or Cad. plated Magnesium steel or

• AllOy aluminum Steel, Oadmium Cad. Plated Steel Cad. Plated Steel Cad. Plated Steel Cadmium Cad. plated plated plated steel or ateel aluminum Steel, Corrosion Corrosion Resiat. Cad. Plated Steel Corrosion Resiat- Cadmium Cad. plated Resisting Steel or Cad. Ing Steel plated steel or plated steel steel aluminum Tinned Copper Terminal and Jumper Aluminum Alloy Cad. Plated Steel Cad. Plated Steel Cad. plated steel Aluminum Cad. plated aline ateol

Page 234OCROpen in PDF

Page 192 AC 43.12-1A 1972 CAD. PL. STEEL AN 735 CLAMP SCREW COPPER

TERMINAL

ALUMINUM

CYLINDRICAL WASHERS

SURFACE CAD. PL. STEEL

LOCKWASHER CAD. PL. STEEL

LOCKNUT FIGURE 11.15-Copper jumper connecter to tubular structure.

CAD. PL. STEEL SCREW AN 735 CLAMP WASHER ALUMINUM

• STRUCTURE _ ALUMINUM

ALUMINUM ALLOY WASHER OR CORROSION.

RESISTING STEEL CAD. PL. STEEL

CONDUIT LOCKWASHER CAD. PL. STEEL

LOCKNUT FIGURE 11.16.-Bonding condult to structure.

CAD. PL. STEEL SCREW AN 735 CLAMP

ALUMINUM WASHER

ALUMINUM

TERMINAL

Page 235OCROpen in PDF

AC 43.13-1A 1972 avoided, the choice of jumper and hardware should be such that corrosion is minimized, and the part likely to corrode would be the jumper or associated hardware. Figures 11.12 through 11.17 show the proper hardware combinations for making a bond connection. At locations where finishes are removed, apply a protective finish to the completed connection to prevent subsequent corrosion.

c. Bonding Jumper Attachment. Avoid the use of solder to attach bonding jumpers. Bond tu- Page 193 bular members by means of clamps to which the jumper is attached. Proper choice of clamp material will minimize the probability of corrosion.

d. Ground Return Connection. When bonding jumpers carry substantial ground return current, determine that the current rating of the jumper is adequate, and that a negligible voltage drop is produced.

453.-463. RESERVED.

Page 236OCROpen in PDF

Page 194 AC 43.13-1А 1972 Section 4. WIRE MARKING

464. WIRE IDENTIFICATION. To facilitate instal- 465. SLEEVE SELECTION FOR IDENTIFICATION.

lation and maintenance, original wire-marking identification is to be retained. The wire identi- a. Flexible vinyl sleeving, either clear or fication marking should consist of a combina- opaque, is satisfactory for general use.

tion of letters and numbers which identify the b. For sleeving exposed to high temperatures wire, the circuit it belongs to, its gauge size, and any other information to relate the wire to (over 400° F.), use materials such as silicone rubber or silicone fiberglas.

a wiring diagram. The preferred method is to stamp the identification marking directly on c. Use nylon sleeving in areas where resistthe wire. Place identification markings at each ance to solvent and synthetic hydraulic fluids end of the wire and at 12- to 15-inch intervals is necessary. The size of identification sleeving along the length of the wire. Wires less than & for the various sizes of wire are shown in inches long need not be stamped. Wire lengths fgure 11.18.

8 to 7 inches should be stamped at the center.

If the outer covering or wire insulation will FIGURE 11.18.-Sizes of identification sleeving.

not stamp easily, insulating tubing may be stamped with the identification mark and in- Wire Size Sleeving Bixe stalled on the wire. Identification sleeves are MIL-W-50в6 MIL- X7-9072 Nominal I.D.

normally used for identifying the following AN No. (inches) types of wire or cable: #24 12 .085

a. Unjacketed shielded wire. #22 #20 10 11 ,095 .106

b. Thermocouple wire. #18 .118 #16 .118

c. Multiconductor cable. #14 7 •148 # 12 .166

d. High temperature wire with insulation #10 4 .208 difficult to mark (such as asbestos, teflon, and #8 #8 2 .268 fiberglas). #6 #6 .380 #4 #4 8/8 Inch .875

(1) Thermocouple wire identification is nor- #2 #2 1/2 inch .500 mally accomplished by means of identification #1 #1 1/2 inch -500 sleeves. As the thermocouple wire is usually of #0 #0 5/8 inch .625 the duplex type (two insulated wires within #00 #00 5/8 inch -625 the same casing), each wire at the termination Doint bears the full name of the conductor #0000 #000 #000 #0000 8/4 Inch 8/4 inch .750 -750

Page 237OCROpen in PDF

AC 43.13-1A Роде 195 1972

PRESSURE -

SENSITIVE TAPE XYZ15

SLEEVE MARKER

TIED IN PLACE XYZ15 FIGURE 11.10.--Identification of wire bundles and harnesses.

467,-477. RESERVED.