1 Oct 72 AC 70/7460- 1B

(16) Structures more than 1950 feet but not more than 2100 feet:

(a) Red lights, apply 19b(2) (n).

(b) White lights, 1 At a near top level apply 2la(1).

At approximately six-sevenths, nine-fourteenths, onehalf, five-fourteenths, and one-seventh of the overall height apply 21a(3).

b. Antenna Towers and Similar Open Structures. Not applicable to these types of structures at this time. * Chap. 8 Par. 25 Page 47 (and 48)

Page 47OCROpen in PDF

1 Oct 72 AC 70/7460- 1B Appendix 1

DOUBLE OBSTRUCTION

LIGHT FITTING (Fresnel Globe)

SINGLE OBSTRUCTION

LIGHT FITTING (Fresnel Globe) 300 mm ELECTRIC CODE BEACON (Fresnel Lens) 24-Inch Double End 24-Inch Single End 36-Inch Double End ROTATING BEACONS Pace 1

Page 48OCROpen in PDF

AC 70/7460-1B 1 Oct 72 Appendix i A-More than 150 ft. but not more than 300 fl.

A -Not more than 150 fl.

A-More than 300 ft. but not more than 450 ft.

PAINTING AND LIGHTING OF TOWERS, POLES AND SIMILAR OBSTRUCTIONS Page 2

Page 49OCROpen in PDF

1 Oct 72 AC 70/7460-1B Appendix i Not less than 5 ft.

nor more than 10 ft.

Not less than 5 ft.

nor more than 10 ft Special double obstruction light

SUSPENSION TYPE

OBSTRUCTION LIGHT

INSTALLATION A-More than 300 ft. but not more than 450 fl.

A-Not more than 150 ft.

PAINTING AND LIGHTING OF SMOKESTACKS AND SIMILAR OBSTRUCTIONS Page 3

Page 50OCROpen in PDF

AC 70/7460-1B Appendix 1 1 Oct 72

LIGHTING MARKING LIGHTING MARKING A-More than 150 ft. but not more than 300 fl. A and B- 15 ft. A and B-Not more A -5 ft. or more B-Not more than 150 ft. or more than 150 ft. B-Less than 15 ft.

PAINTING AND LIGHTING OF WATER TOWERS AND SIMILAR OBSTRUCTIONS Page 4

Page 51OCROpen in PDF

1 Oct 72 AC 70/7460-1B Appendix 1

LIGHTING

MARKING A-More than 150 ft. but not more than 300 ft. A and B- 15 ft. or more B-Not more than 150 ft.

PAINTING AND LIGHTING OF WATER TOWERS AND SIMILAR OBSTRUCTIONS

Page 52OCROpen in PDF

AC 70/7460-1B Appendix i 1 Oct 72

- B Á-More than 150 fl. but not more than 300 fl. LIGHTING A and B-15 ft. or more MARKING A and B-Not more LIGHTING A-5 ft. or more MARKING than 150 ft. B- Less than 15 ft.

B-Not more than 150 ft.

PAINTING AND LIGHTING OF GAS HOLDERS AND SIMILAR OBSTRUCTIONS Pade f

Page 53OCROpen in PDF

1 Oct 72 S# 20/74601

PAINTING OF SI

Page 54 · 8OCROpen in PDF

AC 70/7460-1B Appendix 1 1 Oct 72 BRIDGE Page 8

Page 55OCROpen in PDF

1 Oct 72 АС 70/7460-1B Appendix 1 1 Do Not Paint I white

VORTAC-VOR & TVOR SIMILAR

END SIDE PLAN

TYPICAL BUILDING

Page 56OCROpen in PDF

AC 70/7460-1B Appendix 1 I Oct 72 Do Not Paint Rooty IRAILER (Mark as shown) « Plastic Rail-Do Not Paint, SeE Nor So Not Mert Waveguide .owrea PLAN ROOF

DIRECTIONAL LOCALIZER LOCALIZER ANTENNA

WAYEGUIDE SHELTER SUPPORI

ELEVATION Note: Supports up to 15'high paint white. Over 15' paint three equal horizontal bands, middle band white, others aviation surface orange.

PLAN "V" RING ANTENNA ARRAY PLATFORM Page 10

Page 57OCROpen in PDF

1 Oct 72 AC 70/7460-1B Appendix 1 CHAPTER 6, 19a

SPECIFICATIONS FOR

LIGHTING TOWERS, POLES

AND SIMILAR OBSTRUCTIONS

AVIATION RED OBSTRUCTION LIGHTING (NIGHTTIME) HEIGHT OF LIGHTS ON STRUCTURE IN FEET ABOVE GROUND LEVEL 1200 LEGEND:

CODE BEACONS

OBSTRUCTION LIGHTS 1000 TOP 800 TOP 5/6 600 TOP 400 TOP 3/4 1/2 2/5 1/3 200 150 300 450 600 750 900 12 LEVELS 3 LEVELS- *+4 LEVELS - 5 LEVELS - →#6 LEVELS-→

HEIGHT OF STRUCTURE IN FEET ABOVE GROUND LEVEL Page 11