1 Oct 72 AC 70/7460- 1B
(16) Structures more than 1950 feet but not more than 2100 feet:
(a) Red lights, apply 19b(2) (n).
(b) White lights, 1 At a near top level apply 2la(1).
At approximately six-sevenths, nine-fourteenths, onehalf, five-fourteenths, and one-seventh of the overall height apply 21a(3).
b. Antenna Towers and Similar Open Structures. Not applicable to these types of structures at this time. * Chap. 8 Par. 25 Page 47 (and 48)
1 Oct 72 AC 70/7460- 1B Appendix 1
DOUBLE OBSTRUCTION
LIGHT FITTING (Fresnel Globe)
SINGLE OBSTRUCTION
LIGHT FITTING (Fresnel Globe) 300 mm ELECTRIC CODE BEACON (Fresnel Lens) 24-Inch Double End 24-Inch Single End 36-Inch Double End ROTATING BEACONS Pace 1
AC 70/7460-1B 1 Oct 72 Appendix i A-More than 150 ft. but not more than 300 fl.
A -Not more than 150 fl.
A-More than 300 ft. but not more than 450 ft.
PAINTING AND LIGHTING OF TOWERS, POLES AND SIMILAR OBSTRUCTIONS Page 2
1 Oct 72 AC 70/7460-1B Appendix i Not less than 5 ft.
nor more than 10 ft.
Not less than 5 ft.
nor more than 10 ft Special double obstruction light
SUSPENSION TYPE
OBSTRUCTION LIGHT
INSTALLATION A-More than 300 ft. but not more than 450 fl.
A-Not more than 150 ft.
PAINTING AND LIGHTING OF SMOKESTACKS AND SIMILAR OBSTRUCTIONS Page 3
AC 70/7460-1B Appendix 1 1 Oct 72
LIGHTING MARKING LIGHTING MARKING A-More than 150 ft. but not more than 300 fl. A and B- 15 ft. A and B-Not more A -5 ft. or more B-Not more than 150 ft. or more than 150 ft. B-Less than 15 ft.
PAINTING AND LIGHTING OF WATER TOWERS AND SIMILAR OBSTRUCTIONS Page 4
1 Oct 72 AC 70/7460-1B Appendix 1
LIGHTING
MARKING A-More than 150 ft. but not more than 300 ft. A and B- 15 ft. or more B-Not more than 150 ft.
PAINTING AND LIGHTING OF WATER TOWERS AND SIMILAR OBSTRUCTIONS
AC 70/7460-1B Appendix i 1 Oct 72
- B Á-More than 150 fl. but not more than 300 fl. LIGHTING A and B-15 ft. or more MARKING A and B-Not more LIGHTING A-5 ft. or more MARKING than 150 ft. B- Less than 15 ft.
B-Not more than 150 ft.
PAINTING AND LIGHTING OF GAS HOLDERS AND SIMILAR OBSTRUCTIONS Pade f
1 Oct 72 S# 20/74601
PAINTING OF SI
AC 70/7460-1B Appendix 1 1 Oct 72 BRIDGE Page 8
1 Oct 72 АС 70/7460-1B Appendix 1 1 Do Not Paint I white
VORTAC-VOR & TVOR SIMILAR
END SIDE PLAN
TYPICAL BUILDING
AC 70/7460-1B Appendix 1 I Oct 72 Do Not Paint Rooty IRAILER (Mark as shown) « Plastic Rail-Do Not Paint, SeE Nor So Not Mert Waveguide .owrea PLAN ROOF
DIRECTIONAL LOCALIZER LOCALIZER ANTENNA
WAYEGUIDE SHELTER SUPPORI
ELEVATION Note: Supports up to 15'high paint white. Over 15' paint three equal horizontal bands, middle band white, others aviation surface orange.
PLAN "V" RING ANTENNA ARRAY PLATFORM Page 10
1 Oct 72 AC 70/7460-1B Appendix 1 CHAPTER 6, 19a
SPECIFICATIONS FOR
LIGHTING TOWERS, POLES
AND SIMILAR OBSTRUCTIONS
AVIATION RED OBSTRUCTION LIGHTING (NIGHTTIME) HEIGHT OF LIGHTS ON STRUCTURE IN FEET ABOVE GROUND LEVEL 1200 LEGEND:
CODE BEACONS
OBSTRUCTION LIGHTS 1000 TOP 800 TOP 5/6 600 TOP 400 TOP 3/4 1/2 2/5 1/3 200 150 300 450 600 750 900 12 LEVELS 3 LEVELS- *+4 LEVELS - 5 LEVELS - →#6 LEVELS-→
HEIGHT OF STRUCTURE IN FEET ABOVE GROUND LEVEL Page 11