AD 47-10-02

Airworthiness directive · Elevator Tab Control Circuit Breaker · Lockheed 49-46

Model
49-46
Data sheet
TCDSA-763
Registered aircraft
1 matched by model
Product
Aircraft · Large airplane

Unofficial copy of the text in the FAA’s Dynamic Regulatory System. The FAA’s own copy is the authoritative one. DRS record last changed May 30, 2024.

On this page

The airworthiness directive

47-10-02 LOCKHEED: (Was Mandatory Note 1 of AD-763-3). Applies Only to Model 49 Serial Numbers 2021 to 2054, Inclusive.

Compliance required prior to March 1, 1947.

Install an AN 3161-P15 (or equivalent) non-trip-free circuit breaker in the elevator tab control circuit. The breaker is to be located in the pilots' control stand, with access through a plate immediately forward of the control quadrant. Minor wiring changes to connect the circuit breaker are also necessary. (LAC Service Bulletin 049/SB-4 covers this same subject.)

Affected TCDS · 1

The type certificate data sheets for the models this AD names, matched by model and maker.

Registered aircraft · 1

Registered aircraft whose airframe or engine model this AD names. Matched by model only, so check each against the AD’s applicability.

By aircraft maker
  • Lockheed1 aircraft

By model

Aircraft