The airworthiness directive

55-09-03 DOUGLAS: Applies to All DC-6 Series Aircraft Incorporating Hamilton Standard Propellers Prior to Serial No. 473.

To be accomplished as soon as practicable but not later than August 1, 1955.

Loss of manual r.p.m. control can occur as a result of tripping of the fast-acting magnetic circuit breaker before the slow-acting fuse is blown on a faulted branch. Improved circuit protective coordination and resultant reliability in the manual control function should be provided by replacing the "Manual" 10-ampere magnetic circuit breaker with a 5-ampere thermal type breaker, and replacing the four 5-ampere fuses in the synchronizer unit with 2-ampere Slo-Blo fuses.

(Douglas Service Letter DC-6 No. 171 dated November 17, 1953, and Hamilton Standard Service Bulletin No. 283 dated December 21, 1953, covers this same subject.)

Affected TCDS · 3

The type certificate data sheets for the models this AD names, matched by model and maker.

Registered aircraft · 17

Registered aircraft whose airframe or engine model this AD names. Matched by model only, so check each against the AD’s applicability.

By aircraft maker
  • Douglas17 aircraft
By year built
19531959
Registered aircraft by year built: 11 aircraft
19531
19542
19561
19573
19583
19591

6 with no year recorded

By model

Aircraft

See all 17 aircraft