- Effective
- December 20, 1973
- Model
- Chemical Oxygen Generators
- Product
- Appliance
- Amendment
- 39-1756
Unofficial copy of the text in the FAA’s Dynamic Regulatory System. The FAA’s own copy is the authoritative one. DRS record last changed May 30, 2024.
Copies of the files this page was built from, with their SHA-256. Retrieved October 18, 2026.
| File | Size | SHA-256 | Original |
|---|---|---|---|
| FAA DRS HTML | 19 KB | e34e66cd…1b8afa3 | FAA DRS (API key needed) |
On this page
The airworthiness directive
73-26-05 SCOTT AVIATION DIVISION of ATO INC: Amdt. 39-1756. Applies to chemical oxygen generators, Scott Part Numbers 801386-01, -02, and -03, and 801462-01, -02, and -03.
Compliance required within the next six months after the effective date of this AD, unless already accomplished.
To detect generators showing evidence of corrosion, and to replace corroded units, accomplish Scott Aviation Service Bulletin 35-38, dated February 1, 1973, and Revision Number 1, dated May 11, 1973, or an equivalent procedure approved by the Chief, Engineering and Manufacturing Branch, FAA, Eastern Region.
This amendment is effective December 20, 1973.