N11187

Service difficulty reports · 65

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N11187' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20220309034Not Reported · not reportedLANDING GEAR AIR GROUND FAIL ON ROTATION (TAKE OFF). DURING JACKING NLG STRUT FAILED TO FULLY EXTEND AUTOMATICALLY AND L PROXIMITY SWITCH FAILED TO ENGAGE. 1 NEW OCCURRENCE OF "LG AIR/GRD-PROX SW FAIL" NOTED ON CMC. CLEANED ALL LG LEGS AND SERVICES NLG STRUTS.Mar 9, 2022 · N11187 · Emb EMB145XR · Main Landing GearSDR JJBA20211227036Pressure Sensor · inoperativeRUDDER 1-2 INOPERATIVE ON SHORT FINAL INTERMITTENT. DAU WAS REPLACED AND SUSPECTED TO BE CAUSE OF MULTIPLE SYSTEM MALFUNCTIONS. AFTER TAKE OFF THE DAU 2A FAIL MESSAGE DISPLAYED AND THE RUDDER SYS 1-2 INOPERATIVE MESSAGE REAPPEARED AFTER EMERGENCY WAS DECLARED.Dec 27, 2021 · N11187 · Emb EMB145XR · Rudder Control SystemSDR JJBA20210516014Placard · misinstalledPLACARDS ON EMERGENCY EXIT DOORS ARE INCORRECTLY APPLIED. FOUND LH AND RH ESCAPED HATCH IN WRONG POSITIONS, MOVED ESCAPE HATCHES TO CORRECT POSITIONS. OPS CHECK SAT.May 16, 2021 · N11187 · Emb EMB145XR · Placards and MarkingsSDR JJBA20210403008Seat Frame · crackedCRACKED AISLE SIDE FRAMES ON SEATS 8A, 9A, AND 22A. R&R SEATS 8A, 9A, AND 22A.Apr 3, 2021 · N11187 · Emb EMB145XR · Passenger Compartment EquipmentSDR JJBA20210125025Battery Pack · inoperativeEMERGENCY LIGHTS, BATTERY NR 2 INOPERATIVE. R & R EMERGENCY LIGHTS, BATTERY NR 2. OPERATIONS TEST SATISFACTORY.Jan 25, 2021 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20210123041Connector · disconnectedAFT EMERGENCY CEILING LIGHT EXIT SIGN INOPERATIVE. DISCONNECTED CONNECTOR AND RECONNECTED CONNECTOR. OPERATIONS CHECK SATISFACTORY.Jan 23, 2021 · N11187 · Emb EMB145XR · Light System WiringSDR JJBA20210108002Battery Pack · inoperativeEMERGENCY LIGHTS LT & RT MARKERS & OVERHEAD ON EXIT ROW 18 INOPERATIVE. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT BATTERY. OPERATIONS CHECK GOOD.Jan 8, 2021 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20201210011Connector · unsecureLT EMERGENCY EXIT SIGN LIGHT (UPPER) INOPERATIVE AT SEAT 18A. ADJUSTED ELECTRICAL CONNECTORS. OPERATIONS CHECK SATISFACTORY.Dec 10, 2020 · N11187 · Emb EMB145XR · Light System WiringSDR JJBA202008310025Sign · inoperativeLT AFT UPPER EMERGENCY LIGHT/MARKING SIGN ASSEMBLY INOPERATIVE. R&R LT AFT UPPER EMERGENCY MARKING ASSEMBLE. OPERATIONS CHECK SATISFACTORY.Aug 30, 2020 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20191021009Light · missingMISSING EMERGENCY LIGHT STRIP BY ENTRANCE. INSTALLED EMERGENCY LIGHT STRIP. NO DEFECTS NOTED AT THIS TIME.Oct 21, 2019 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA201908195007Warning Message · false indicationBATTERY 1 OVER TEMP MESSAGE ON EICAS. PERFORMED QRH PROCEDURES. R&R BATTERY 1. OPS CHECK SAT. BATTERY TEMP WITHIN LIMITSAug 15, 2019 · N11187 · Emb EMB145XR · Battery/Charger SystemSDR JJBA2019041109007Carbon Seal · failedFUMES DETECTED IN BOTH COCKPIT AND CABIN DURING DESCENT. R&R #1 ENGINE NO 0 CARBON SEAL AND FAN DRIVE SHAFT. OPS AND LEAK CHECK SAT. DECONTAMINATED PACKS 1 AND 2. NO OIL SMELL PRESENT IN COCKPIT OR CABIN.Apr 9, 2019 · N11187 · Emb EMB145XR · Turbine Engine Air Inlet SectionSDR JJBA201902069050Floorbeam · tornRIGHT FLOOR BEAM AT FR 23 TORN / DAMAGED AT NUT PLATE HOLE. REPAIRED RIGHT FLOOR BEAM AT FR 23 TORN / DAMAGED AT NUT PLATE HOLE BY CUT OUT, DOUBLER FABRICATION AND INSTALLATION.Jan 29, 2019 · N11187 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA201902069049Stringer · chafedSTRINGER 2L BETWEEN FRAMES 20 AND 21 CHAFFED. REMOVED CHAFE FROM STRINGER 2L BETWEEN FRAMES 20 AND 21 VIA BLEND OUT. AFTER BLEND OUT 0.018 DEPTH AND 4.190 LENGTH MATERIAL REMOVED AND THERE ARE NO SPECIFIC TOLERANCES GIVEN AND EXCEEDS NON-SIGNIFICANT DAMAGE TOLJan 29, 2019 · N11187 · Emb EMB145XR · Fuselage Main, Longeron/StringerSDR JJBA201902068048Floor Support · corrodedCORROSION - LH OMEGA BEAM LOWER FLANGE FR 23-29. REMOVED CORROSION FROM LH OMEGA BEAM LOWER FLANGE FR 23-29 VIA BLEND OUT. AFTER BLEND OUT 0.017 MATERIAL WAS REMOVED AT DEEPEST POINT AND ONLY 0.015 IS ALLOWED. FABRICATED, LOCATED, INSTALLED, DOUBLER. RESTORED Jan 28, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA201902068047Skin · crackedHFEC INSPECTION SHOWS THE EXTERNAL FUSELAGE SKIN TO HAVE A CRACK APPROXIMATELY .25" LONG AT FRAME 75 AND STRINGER 2L AS MARKED. INSTALLED NEW FABRICATED DOUBLER, FILLER, SHIM, AND ANGLE AT SKIN FRAME 75, STGR 2L.Jan 28, 2019 · N11187 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR JJBA201902068046Floor Support · corrodedCORROSION FOUND ON LEFT OMEGA BEAM JUST AFT OF FR 59 UPON POST REMOVAL INSPECTION OF LH FLOOR BEAM GUSSET BETWEEN FRAMES 59-61. PERFORMED CUT OUT, FABRICATED AND INSTALLED REPAIR DOUBLER FOR LH OMEGA BEAM BETWEEN FRAMES 59-61.Jan 28, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA201902068045Floor Support · corrodedCORROSION ON CENTER OMEGA BEAM AT FR 20 UNDERNEATH SILL. REMOVED AND REPLACED CENTER OMEGA BEAM AT FR 20. RESTORED SURFACE PROTECTION.Jan 28, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA201902067044Floor Support · corrodedCORRODED LH FLOOR BEAM GUSSET BETWEEN FR 59-61 AROUND NUT PLATE. REMOVED AND REPLACED LH OMEGA BEAM GUSSET FRAME 59-61. RESTORED SURFACE PROTECTION. LEVEL 2 CORROSION.Jan 27, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA201902065043Seal · corrodedCARGO, BAGGAGE COMPARTMENT FWD BULKHEAD FLOOR SEAL CORRODED AT FRAME 61 LEFT SIDE AT FLOOR LEVEL. REMOVED AND REPLACED FLOOR SEAL IN CARGO, BAGGAGE COMPARTMENT FWD BULKHEAD. RESTORED SURFACE PROTECTION. LEVEL 2 CORROSIONJan 25, 2019 · N11187 · Emb EMB145XR · Fuselage Main, BulkheadSDR JJBA201902065042Floor Support · corrodedCORROSION - LH OB SILL FR 29-35 AS MARKED. REMOVED AND REPLACED LH FLOOR SILL AT FR 29-35. RESTORED SURFACE PROTECTION. LEVEL 2 CORROSION.Jan 25, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20190205041Floor Support · corrodedCORROSION - LH OMEGA BEAM LOWER FLANGE FR 29-35. REPAIRED CORROSION - LH OMEGA BEAM LOWER FLANGE FR 29-35 BY REAMING, FILLING WITH HYSOL, DOUBLER FABRICATION AND INSTALLATION.Jan 25, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA2019020613040Floor Support · corrodedLH OMEGA BEAM AT FR 46 TO FR 49 HAS CORROSION AS MARKED. INSTALLED REPAIR DOUBLER AND TOP COAT.Jan 23, 2019 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA2019020617039Frame · corrodedSTOP SIGN DOUBLER AT FR 22 HAS CORROSION. REMOVED, REPLACED AND TOP COATED STOP SIGN DOUBLER AT FR 22. CORROSION LEVEL 2Jan 17, 2019 · N11187 · Emb EMB145XR · Fuselage Main, FrameSDR JJBA201811165005Fan · inoperativeAT CRUISE HEARD BUZZING NOISE FROM UNDER CAPTAIN'S FLOOR AND SMELLED SMOKE. (CREW MENTIONED A SMOKE DID DEVELOP). FOUND THAT THE #2 ELECTRONIC COMPARTMENT FAN WAS NOT WORKING. REMOVED AND REPLACED #2 FWD ELECTRONIC COMPARTMENT COOLING FAN. OPS CHECK SAT. NO FUNov 15, 2018 · N11187 · Emb EMB145XR · Air Distribution FanSDR JJBA20180404003Light · unknownEMERGENCY LIGHT INOPERATIVE AT ROW 18A. PERFORMED AN OPERATIONAL CHECK OF EMERGENCY LIGHT SYSTEM. OPS CHECK GOOD. NO OTHER DEFECTS NOTED.Apr 4, 2018 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20171125010Wire · unsecureOVERHEAD EMERGENCY EXIT LIGHTS INOPERATIVE. SECURED THE WIRE TERMINALS.Nov 25, 2017 · N11187 · Emb EMB145XR · Light System WiringSDR JJBA20171005003Lamp · unsecureFIRST CEILING EMERGENCY LIGHT INOPERATIVE. ADJUSTED THE LAMP, OPS CHECKED GOOD.Oct 5, 2017 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA201708220018Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. R & R THE BATTERY PACKS NR 1 AND 2.Aug 20, 2017 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20170601002Light · intermittentLIGHT OVER LEFT EMERGENCY EXIT INOPERATIVE. PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHT SYSTEM OPS CHECK SAT.Jun 1, 2017 · N11187 · Emb EMB145XR · Emergency LightingSDR JJBA20170406006Light · malfunctionedFWD EMERGENCY LIGHT AT ROW 18 INOPERATIVE. IAW MX CONTROL, CYCLED EMERGENCY LIGHTS, OPS CHECKED GOOD. NO MX ACTION REQUIREDApr 6, 2017 · N11187 · Emb EMB145XR · Emergency LightingSDR ASOA2016115005Skin · dentedFORWARD FUSELAGE 1, SKIN LT SIDE HAS DAMAGE FROM A BIRD STRIKE. CUTOUT DAMAGED AREA, FABRICATED DOUBLER AND FILLER. REMOVED DAMAGED SECECTION OF RIB 4 AND SPLICED IN NEW SECTION. HFEC EFFECTED AREA AND NO DEFECTS NOTED AT THIS TIME.Jan 14, 2016 · N11187 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR ASOA20141026300Control Panel · failedDURING FLIGHT, RAPID DEPRESSURIZATION AT 36,000 FT. R & R CPAM IAW AMM 21-32-01. OPS AND LEAK CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 26, 2014 · N11187 · Emb EMB145XR · Cabin Pressure Control SystemSDR ASOA20141021117RInverter · inoperativeDURING MX INSPECTION THE FWD AISLE OVERWING EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. MAINTENANCE R & R THE NR 6 EMERGENCY LIGHT INVERTER WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 21, 2014 · N11187 · Emb EMB145XR · Emergency LightingSDR ASOA20140704077Inverter · inoperativeDURING ROUTINE CHECK, THE LOWER SERVICE DOOR EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. MAINTENANCE R & R NR 2 EMERGENCY LIGHT SYS INVERTER AND OPS CHECKED SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 4, 2014 · N11187 · Emb EMB145XR · Emergency LightingSDR ASOA20140516055Light · inoperativePILOT REPORTED EMERGENCY EXIT SIGN INOPERATIVE. MX RESET SYS AND OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.May 16, 2014 · N11187 · Emb EMB145XR · Emergency LightingSDR ASOA20140322067Bracket · crackedDURING C-CHECK, FOUND BRACKET SUPPORTING A OVERFLOW LINE FROM THE VENTRAL TANK CRACKED. MAINTENANCE FABRICATED A NEW BRACKET AND INSTALLED IAW SRM 53-20-07.Mar 22, 2014 · N11187 · Emb EMB145XR · Fuselage Main, Attach FittingsSDR ASOA20140318050Channel · corrodedDURING C-CHECK, FOUND THE OMEGA BEAM AND TOPCAP CORRODED. MAINTENANCE INSTALLED A NEW REPAIR TO THE OMEGA BEAM WITH A NEW TOP CAP IAW EC 5310-01473 AND SRM 51-40-02.Mar 18, 2014 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA201218004Tank · chafedACFT IS IN FOR A 3C INSPECTION, WHEN INSPECTION FOUND THE VENTRAL TANK BOTTOM CENTER CHAFED. MX PERFORMED A DOUBLER REPAIR ON THE VENTRAL TANK. FABRICATED AND INSTALL THE DOUBLER AFTER ALLODINED, PRIMED, PAINTED, SEAL AND REMOVED FAIRING 197 BB TO PREVENT FUFeb 18, 2012 · N11187 · Emb EMB145XR · Fuel StorageSDR ASOA20120222009Floor Support · corrodedLT OMEGA BEAM TOP CAP CORRODED AT FRM 61. R & R TOP CAP.Feb 16, 2012 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20120222008Floor Support · corrodedCTR OMEGA BEAM TOP CAP CORRODED AT FRM 61 CARBON BEAM. R & R TOP CAP.Feb 16, 2012 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20120222007Floor Support · corrodedRT OMEGA BEAM TOP CAP CORRODED AT FRM 61 CARBON BEAM. R & R TOPCAP.Feb 16, 2012 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20120222006Sill · corrodedRT LAVATORY FLOOR SILL CORRODED AT FRM 61 CARBON BEAM. REPLACED FLOOR SILL AT FRM 61.Feb 16, 2012 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20120222005TBracket · wornLT AILERON PCA BRACKET FITTING MOST OTBD HAT BUSHING MIGRATED. R & R BRACKET.Feb 16, 2012 · N11187 · Emb EMB145XR · Wing, Attach FittingsSDR ASOA20120222010Sill · corrodedLEFT CABIN FLOOR SILL CORRODED FRM 18-23. R & R FLOOR SILL FRM 18-23.Feb 15, 2012 · N11187 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR C2XA11CL075Unknown · malfunctionedORD FLT 5916 - THE CREW REPORTED AIRCRAFT PULLED TO THE LEFT ON LANDING. CREW DISCONNECTED NOSE WHEEL STEERING AND LOST CONTROL OF AIRCRAFT. THE AIRCRAFT DEPARTED THE RUNWAY. SUPPLEMENT TO FOLLOW.Mar 18, 2011 · N11187 · Emb EMB145XR · Landing Gear Steering SystemSDR C2XA11CL043Control Unit · faultyTHE CREW REPORTED A LOUD BANGING NOISE AND SHUTTER ON GEAR RETRACTION. MAINTENANCE INSPECTED AND REPLACED THE BRAKE CONTROL UNIT. OPERATIONAL CHECKS WERE GOOD.Feb 8, 2011 · N11187 · Emb EMB145XR · Landing Gear Brake SystemSDR C2XA11CL037Connector · looseORD FLT 5992 - THE CREW REPORTED A NOSE GEAR INDICATION NOT SHOWING DOWN. MAINTENANCE INSPECTED AND CLEANED AND RE-SECURED THE CONNECTORS ON THE NOSE GEAR DOWN LOCK PROXIMITY SWITCHES. OPERATIONAL CHECKS WERE GOOD.Jan 28, 2011 · N11187 · Emb EMB145XR · Landing Gear System WiringSDR C2XA10CL143Pressure Switch · brokenCLE FLT 5916 THE CREW REPORTED AN ENGINE 2 BLEED VALVE FAIL MESSAGE APPEARED AT 60 KNTS. THE TAKEOFF WAS ABORTED AND TAXIED BACK TO GATE. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ENGINE HIGH STAGE VALVE PRESSURE SWITCH. ALSO REPLACED THE NR 2 ENGINE BLEESep 1, 2010 · N11187 · Emb EMB145XR · Pneumatic Distribution SystemSDR C2XA10TY116Aileron · damagedTYS - A/C WAS FOUND WITH A POSSIBLE LIGHTNING STRIKE INDICATION. THE LEFT AILERON WAS BURNT. MAINTENANCE PERFORMED A LIGHTNING STRIKE INSPECTION AND R/R THE LEFT AILERON TIP. WORK ACCOMPLISHED IAW 145 AMM 5-50-01 AND THE DAMAGED TIP REPAIRED IAW SRM 57-60-0Aug 18, 2010 · N11187 · Emb EMB145XR · Ailerons
Back to N11187