N11193
Service difficulty reports · 136
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N11193' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N11193' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20240304067Gusset · corrodedAT CF2, CORROSION FOUND ON LH GUSSET #2 BTW FR 23 AND FR 30 IN FLOOR STRUCTURE AREA. CF2, LH GUSSET #2 BTW FR 23-30 CORROSION BLENDED AND FOUND OUT OF LIMITS. CF2, LH GUSSET #2 REPLACEDSDR JJBA20240226059Door Frame · corrodedCF1, CORROSION FOUND ON RH SERVICE DOOR FWD SILL FRAME BTW FR 18-20. IN CF1, RH SERVICE DOOR FWD SILL BTW FR 18-20 BLENDED AND FOUND OUT OF LIMITS. IN CF1 RH SERVICE DOOR SILL BTW FR 18-20 REMOVED AND REPLACEDSDR JJBA20240223055Floor Support · corrodedCF1, CORROSION FOUND ON RH DOUBLERS FLOOR STRUCTURE AT FR 20 AND FR 22. IN CF1, ON RH SIDE, DOUBLERS AT FR 20+22 BLENDED AND FOUND OUT OF LIMIT. IN CF1, RH SIDE DOUBLERS AT FR 20+22 REPLACED WITH NEW ONE.SDR JJBA20240304006Shear Tie · crackedAT RF1, FRAME 68, LH SIDE SHEAR CLIP BTW STR 6L-9L FOUND CRACKED. AT RF1, FRAME 68, LH SIDE SHEAR CLIP BTW STR 6L-9L REMOVED AND REPLACED WITH NEW PARTSDR JJBA20240226060Bracket · crackedIN LH ENG PYLON, LH ENG PYLON STRUCTURE FWD PRECOOLER BRACKET IS CRACKED AND BENT. LH ENG PYLON STRUCTURE FWD PRECOOLER BRACKET REMOVED AND REPLACEDSDR JJBA20240223058Bracket · crackedAT FWD FUSE AREA, CRACK FOUND ON LH TOP BRACKET ON FR 10 UNDER SIDE COCKPIT WINDOW SURROUND STRUCTURE. LH TOP BRACKET ON FR10 REPLACED BY NW BRACKETSDR JJBA20240223057Floor Support · corrodedCF1, CORROSION FOUND ON MIDDLE GUSSET FLOOR STRUCTURE BTW FR18-22. IN CFI CTR GUSSET BTW FR 18-22 BLENDED OUT OF LIMITS. IN CF1, CTR GUSSET BTW FR 18-22 REPLACED WITH NEW ONESDR JJBA20240223054Channel · corrodedCF1, CORROSION FOUND ON RH SERVICE DOOR LOWER CHANNEL FRAME BTW FR20-22. RH SERVICE DOOR LOWER CHANNEL BTW FR 20-22 BLENDED AND FOUND OUT OF LIMIT. RH SERVICE DOOR LOWER CHANNEL BTW FR 20-22 REPLACED WITH NEW ONE.SDR JJBA20240304010Shear Tie · crackedCF2, FRAME 24, LH SHEAR CLIP FOUND CRACKED BTW STR 15L-16L. LH SHEAR CLIP AT FR24 BTW STR 15L-16L REPLACEDSDR JJBA20240304008Shear Tie · crackedAT RF1, FRAME 73, RH SHEAR CLIP U/FLOOR BTW STR 8R-10R FOUND CRACKED. AT RF1, FR73 RH SHEAR CLIP U/FLOOR BTW STR 8R-10R REMOVED AND REPLACED WITH NEW PART.SDR JJBA20240223056Floor Support · corrodedAT CFII, CORROSION FOUND ON LH SILL #2 BTW FR 23 AND FR 30 IN FLOOR STRUCTURE AREA. LH SILL #2 BTW FR 23-FR30 BLENDED OUT OF LIMITS. LH SILL #2 REPLACEMENT. LH SILL #2 BTW FR 23-FR36 REPLACEDSDR JJBA20240219053Shear Tie · crackedCF2, FRAME 26, LH SHEAR CLIP FOUND CRACKED BTW STR 15L-16L. LH SHEAR CLIP AT FR 26 BTW STR 15L-16L REPLACEDSDR JJBA20240304021Uplock · crackedNLG W/WELL, CRACK FOUND ON NLG UP-LOCK AFT CROSSBEAM. REMOVED AND REPLACEDSDR JJBA20240304020Shear Tie · crackedCF2, FRAME 25, RH SHEAR CLIP FOUND CRACKED BTW STR 15R-16R. AT FR25 BTW STR 15-16 RH SHEAR CLIP REPLACED.SDR JJBA20240219051Floor Support · corrodedAT CFII, CORROSION FOUND ON RH SILL #1 BTW FR 23 AND FR 30 IN FLOOR STRUCTURE AREA. CORROSION ON RH SILL #1 BTW FR 23-30 BLENDED OUT OF LIMITS. RH SILL #1 BTW FR 23-30 REMOVED FOR REPLACEMENT. NEW RH SILL #1 BTW FR 23-30 INSTALLED WITH RIVETSSDR JJBA20240219050Shear Tie · crackedCF2, FRAME 27, RH SHEAR CLIP FOUND CRACKED BTW STR 15R-16R. AT FR27 BTW STR 15R-16R RH SHEAR CLIP REPLACEDSDR JJBA20240219049Shear Tie · crackedCF2, FRAME 24, RH SHEAR CLIP FOUND CRACKED BTW STR 15R-16R. AR FR24 RH SHEAR CLIP BTW STR 15-16 REPLACED.SDR JJBA20240219048Shear Tie · crackedCF2 FRAME 26, RH SHEAR CLIP FOUND CRACKED BTW STR 15R-16R. AT FR26, RH SHEAR CLIP BTW STR 15-16 REPLACED.SDR JJBA20240219047Doubler · corrodedCF3, RH DOUBLER ON FLOOR STRUCTURE AT FR 49 OVER OMEGA BEAM FOUND CORRODED. RH DOUBLER AT FR49 FLOOR STRUCTURE BLENDED OUT OF LIMITS. RH DOUBLER AT FR 49 REMOVED AND INSTALLEDSDR JJBA20240304015Support · corrodedAT CFIII, CORROSION FOUND ON RH SILL #5 BTW FR 47 AND FR53 IN FLOOR STRUCTURE AREA. RH SILL #5 BTW FR 47 AND FR 53 IN FLOOR STRUCTURE, CORROSION BLENDED AND FOUND OUT OF LIMIT. NEW RH SILL #5 INSTALLEDSDR JJBA20240219052Floor Support · corrodedCF2, RH DOUBLER ON FLOOR STRUCTURE AT FR35 OVER OMEGA BEAM FOUND CORRODED. RH DOUBLER ON FLOOR STRUCTURE AT FR35 BLENDED OUT OF LIMITS. RH DOUBLER AT FR35 REPLACEDSDR JJBA20240304001Floor Support · corrodedAT CFIII, CORROSION FOUND ON RH SILL #3 BTW FR35 AND FR42 IN FLOOR STRUCTURE AREA. RH SILL #2 BTW FR35 AND FR42 IN FLOOR STRUCTURE AREA BLENDED CORROSION AND FOUND OUT OF LIMIT. RH SILL #3 BTW 35 AND FR42 REMOVED AND INSTALLED WITH RIVETS.SDR JJBA20240219044Floor Support · corrodedAT CFII, CORROSION FOUND ON RH SILL #2 BTW FR 29 AND FR 36 IN FLOOR STRUCTURE AREA. RH SILL #2 BTW FR 29 AND FR 36 IN FLOOR STRUCTURE AREA, CORROSION BLENED AND FOUND OUT OF LIMITS. RH SILL #2 BTW FR 29 AND FR 36 REMOVED AND REPLACED.SDR JJBA20240304002Support · corrodedAT CFIII, CORROSION FOUND ON LH SILL #4 BTW FR35 AND FR42 IN FLOOR STRUCTURE AREA. LH SILL #4 BTW FR35-FR42 BLENDED OUT OF LIMIT. LH SILL #4 BTW FR35-FR42 REPLACEDSDR JJBA20240219046Floor Support · corrodedAT CFIII, CORROSION FOUND ON LH SILL #5 BTW FR 41 AND FR 48 IN FLOOR STRUCTURE AREA. LH SILL #5 BTW FR 41-FR48 BLENDED OUT OF LIMITS. LH SILL #5 BTW FR 41-FR48 REPLACEDSDR JJBA20240219045Floor Support · corrodedAT CFIII, CORROSION FOUND ON LH SILL #6 BTW FR 47 AND FR 53 IN FLOOR STRUCTURE AREA. LH SILL #6 BTW FR 47-FR53 BLENDED OUT OF LIMITS. LH SILL #6 BTW FR 47-FR53 REPLACEDSDR JJBA20240219043Floor Support · corrodedAT CFII, CORROSION FOUND ON LH SILL #3 BTW FR 29 AND FR 36 IN FLOOR STRUCTURE AREA. LH SILL #3 BTW FR 29-FR36 BLENDED OUT OF LIMITS. LH SILL #3 BTW FR 29-FR36 REPLACEDSDR JJBA20240304074Gusset · corrodedCF4, LH GUSSET IN TOILET AREA BTW FR59-61 FOUND CORRODED. CF4, LH GUSSET IN TOILET AREA BTW FR59-61 BLENDED AND FOUND OUT OF LIMIT. CF4, LH GUSSET IN TOILET AREA BTW FR59-61 REMOVED FOR REPLACEMENT. CF4, LH GUSSET IN TOILET AREA BTW FR59-61 INSTALLED.SDR JJBA20240304072Gusset · corrodedCF4, MIDDLE GUSSET IN TOILET AREA BTW FR59-61 FOUND CORRODED. IN CF4, CTR GUSSET BTW FR 59-61 BLENDED OUT OF LIMITS AND REMOVED FOR REPLACEMENT. IN CF4, CTR GUSSET BTW FR59-61 REPLACED WITH NEW ONE.SDR JJBA20240304065Gusset · corrodedCF4, RH GUSSET IN TOILET AREA BTW FR 59-61 FOUND CORRODED. RH GUSSET IN TOILET AREA BTW FR 59-61 BLENDED OUT OF LIMITS. RH GUSSET BTW FR 59-61 REPLACED BY NEW GUSSETSDR JJBA20240304083Gusset · corrodedAT CFIII, CORROSION FOUND ON LH GUSSET #5 BTW FR38 AND FR 46 IN FLOOR STRUCTURE AREA. IN CFIII, LH GUSSET #5 BTW FR 38-46 BLENDED AND FOUND OUT OF LIMIT. AT CFIII, LH GUSSET #5 BTW FR38 AND FR46 IN FLOOR STRUCTURE AREA REMOVED FOR REPLACEMENT. AT CFIII, LH GUSSDR JJBA20231113010Lamp · inoperativeFOUND LH OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20230530019Unknown · unknownICU CABIN AND CABIN EMERGENCY LIGHTS FAIL TO RESET. FOUND A BROKEN WIRE AT PLUG P8300 PIN 29. REPAIR THE WIRE. PERFORMED OPS CHECK. OPS CHECK SAT AT THIS TIME.SDR JJBA20230217012None · noneSMOKE COMING FROM SINK IN THE LAV ELECTRICAL BURNING SMELL. FOUND BOTH POT WATER DRAIN HEATERS WORKING NORMALLY. SUSPECT SINK DRAIN HEATER OR ASSOCIATED WIRING. PULLED AND COLLARED CB E-11. INSPECTED WIRING BEHIND AND UNDER LAV SINK COMPARTMENT AND FOUND SMELLSDR JJBA20230106005Charger · inoperativeLH EXTERIOR FORWARD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EXTERIOR EMERGENCY LIGHT LAMP. OPS CHECK FAILED. TROUBLESHOT TO #1 EMERGENCY LIGHT BATTERY AND CHARGER ASSEMBLY INOPERATIVE. REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY. REMOVED AND REPLSDR JJBA20220527058None · noneREMOVED BOTH PILOTS AND COPILOTS O2 MASKS BOX FOR FOM AND FOUND FITTINGS DISCONNECTED. RECONNECTED FITTINGS AND INSTALLED BOTH O2 MASK BOXES. OPS CHECK SATSDR JJBA20220522037None · noneFWD LH EXTERNAL EMERGENCY LIGHT AS CONDENSATION IN THE LENS. REMOVED LENS AND DRIED CONDENSATION. RE-INSTALLED LENS.SDR JJBA20211228041None · noneRAR #2 ANTENNA BASE HAS SIGNS OF CORROSION. REMOVED CORROSION AT RAR #2 ANTENNA BASE, FOUND CRACKS, CUTOUT DAMAGE AREA AND PERFORMED REPAIR. THIS REPAIR IS CONSIDERED TEMPORARYSDR JJBA20211228040None · noneRAD ALT 2, ANTENNA HAS SIGNS OF CORROSION. REMOVED AND REPLACED ANTENNA SUPPORT.SDR JJBA20211213016None · noneBAG BAY CUTOUT TRAILING EDGE GOUGED. BLENDED OUT DAMAGED AREA AND EVALUTATED. FOUND TO BE OUT OF LIMITS. PERFORMED ET AND UT INSPECTION BY BARON NDT, LLCSDR JJBA20211207006None · noneRH VERTICAL PARTITION LOWER SILL ATTACH POINT HAS SIGNS OF CORROSION AT FASTENER HOLES. ACCOMPLISHED PERMANENT REPAIR. SPLICE DOUBLER FABRICATED. CORROSION LEVEL II.SDR JJBA20211201004None · noneLH OB FLOOR SILL SHOWS SIGNS OF CORROSION BETWEEN FRAMES 42-49. REMOVED AND REPLACED DAMAGE SILL BETWEEN FRAMES 42-49 LH SIDESDR JJBA20211127033None · nonePAX DOOR LOWER FWD CORNER BENT. CUTOUT DAMAGE AREA, FABRICATED DOUBLER AND FILLER FROM 2024T3 .080". INSTALLED REPAIR PARTS AT PAX DOOR LOWER FWD CORNER.SDR JJBA20211123037Mount · corrodedRH VERTICAL PARTITION LOWER SILL ATTACH POINT HAS SIGNS OF CORROSION AT FASTENER HOLES. ACCOMPLISHED BEAM FUSELAGE !, FRAME 61 DOUBLER REPAIR AT RH VERTICAL PARTITION LOWER.SDR JJBA20211117033None · noneLH FLOOR SILL FROM FRM 53-59 HAS SIGNS OF CORROSION. REMOVED AND REPLACED FLOOR SILL FROM FR 53 TO 59. RESTORED FINISH AND APPLIED CICSDR JJBA20211115023None · noneSIGNS OF CORROSION ON RH UPPER FLOOR BEAM TRACK SUPPORTS AFT OF FRM 52. REMOVED AND REPLACED BEAM, HAT ASSY FROM FR 49 - FR 55 RHSDR JJBA20211113024None · noneLH AFT FUSELAGE, INTERIOR AT FR59-FR61 @ Y=479.0 HAS SIGNS OF CORROSION UNDER FLOOR BY LAV. REMOVED AND REPLACED LH FR 59 - FR 61 @ Y=479 GUSSETSDR JJBA20211113022None · noneSIGNS OF CORROSION UNDER GUSSET LH AT HAT BEAM FR59-61 BL-479. ACCOMPLISHED CENTER FUSELAGE IV-CF IV FLOOR STRUCTURE OMEGA BEAM, CORROSION PERMANENT REPAIR AT FR 59 AT FR61 BL479 LSDR JJBA20211113021None · noneSIGNS OF CORROSION UNDER GUSSET CENTER AT HAT BEAM FR59-61, BLO. ACCOMPLISHED CENTER FUSELAGE IV-CF IV FLOOR STRUCTURE-OMEGA BEAM CORROSION PERMANENT REPAIR. HAT BEAM, CENTER FR59-FR61, BLOSDR JJBA20211113020None · noneAFT FUSELAGE INTERIOR, FR 59-61 C Y=0.0 HAS SIGNS OF CORROSION UNDER FLOOR BY LAV. REMOVED AND REPLACED GUSSET AT FR 59 - 61 CY=0.0
Back to N11193