N12109
Service difficulty reports · 162
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12109' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12109' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2010111600575Oxygen Mask · crackedSUPPORT TASK - ROW 34D, F O2 MASKS AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111600574Oxygen Mask · crackedSUPPORT TASK - ROW 30D O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600573Oxygen Mask · crackedSUPPORT TASK - ROW 29F O2 MASK AT FLOW INDICATOR FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600572Oxygen Mask · crackedSUPPORT TASK - ROW 28D O2 MASK AT FLOW INDICATOR FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600571Oxygen Mask · crackedSUPPORT TASK - ROW 27D O2 MASK AT FLOW INDICATOR FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600570Oxygen Mask · crackedSUPPORT TASK - ROW 24D, F O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111600569Oxygen Mask · crackedSUPPORT TASK - ROW 23F O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600568Oxygen Mask · crackedSUPPORT TASK - ROW 21D O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600567Oxygen Mask · crackedSUPPORT TASK - ROW 20 D, E, F O2 MASKS AT FLOW INDICATOR FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111600566Oxygen Mask · crackedSUPPORT TASK - ROW 12F O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600565Oxygen Mask · crackedSUPPORT TASK - ROW 11F O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600564Oxygen Mask · crackedSUPPORT TASK - ROW 9D O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600563Oxygen Mask · crackedSUPPORT TASK - ROW 3D O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111600562Oxygen Mask · crackedSUPPORT TASK - ROW 1C O2 MASK AT FLOW INDICATOR, FOUND STRESS CRACKS AT CENTER WELD OF INDICATOR. PB 174080-193 REV D, CUST 417T4205-193. MFG DATE 3-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500561Oxygen Mask · crackedSUPPORT TASK - ROW 29C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500560Oxygen Mask · crackedSUPPORT TASK - ROW 30A AND 30C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111500559Oxygen Mask · crackedSUPPORT TASK - ROW 34A MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500558Oxygen Mask · crackedSUPPORT TASK - ROW 3A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500557Oxygen Mask · crackedSUPPORT TASK - ROW 32A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500556Oxygen Mask · crackedSUPPORT TASK - ROW 38C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500555Oxygen Mask · crackedSUPPORT TASK - ROW 26A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500554Oxygen Mask · crackedSUPPORT TASK - ROW 27A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500553Oxygen Mask · crackedSUPPORT TASK - ROW 39 ABC ALL O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111500552Oxygen Mask · crackedSUPPORT TASK - ROW 22A AND 22C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111500551Oxygen Mask · crackedSUPPORT TASK - ROW 40C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500550Oxygen Mask · crackedSUPPORT TASK - ROW 38A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500549Oxygen Mask · crackedSUPPORT TASK - ROW 12C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500548Oxygen Mask · crackedSUPPORT TASK - ROW 21C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500547Oxygen Mask · crackedSUPPORT TASK - ROW 24A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500546Oxygen Mask · crackedSUPPORT TASK - ROW 4A AND 4B O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111500545Oxygen Mask · crackedSUPPORT TASK - ROW 2A AND 2B O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASKS PER MM 35-21-05.SDR CALA2010111500544Oxygen Mask · crackedSUPPORT TASK - ROW 37A O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUS 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500543Oxygen Mask · crackedSUPPORT TASK - ROW 25A AND 25C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500542Oxygen Mask · crackedSUPPORT TASK - ROW 14C O2 MASK AT FLOW LIMITER, FOUND STRESS CRACKS AT CENTER WELD OF LIMITER. PB 174080-193, REV C CUST 417T4205-193. MFG DATE 6-94 TO 8-94. REPLACED O2 MASK PER MM 35-21-05.SDR CALA2010111500538Floorbeam · corrodedAFT WET AREA FLOORBEAM CORRODED STA 1640 AT BL 0. (MARKED) FABRICATED, TREATED, PRIMED,AND INSTALLED REPAIR PARTS (PART 1 CHORD, PART 2 ANGLE, PART 3 ANGLE, PART 4 STRAP AND PART 5 STRAP) FROM LBL 33-RBL 10 AT STA 1640 REF SRM 53-00-51, SRM 51-40-02 AND SRM SDR CALA2010052000218Oven · malfunctionedAFT GALLEY OVEN 413 SMOKES EXCESSIVELY AND SETS OFF LAV SMOKE DETECTOR. PLACED AFT GALLEY OVEN POS 413 ON MEL. OK TO CONT. PULLED AND COLLARD C/B. REMOVED AND REPLACED NR 413 AFT OVEN. ALL FUNCTIONS NORMAL AT THIS TIME. PLACARD REMOVED. ROTABLE PARTS CHSDR CALA2010010400005Shutoff Valve · leakingCREW 02 PRESS LOW SERVICED CREW 02 FOUND SHUTOFF VALVE LEAKING AND BENT. REMOVED AND REPLACED CREW 02 BOTTLE REF AMM 35-11-00, A/C OK TO CONTINUE. ROTABLE PARTS CHANGE WAS INDICATED - TT 1384230 S/N OFF 06820 BOTTLE, OXY, AI OFF 29-3511-9-9001 8620 ON 29-3SDR CALA2010010400004Light · inoperativeEXTERIOR EMERGENCY EXIT LIGHT BEHIND L3 DOOR IS INOPERATIVE. REMOVED AND REPLACED EXTERIOR EMERGENCY EXIT LIGHT BEHIND L3 DOOR REF AMM 33-51-01.SDR CALA2010010400001Charger · inoperativeCOACH CABIN EMERGENCY LIGHTS AISLE PATH ROWS 15-25 NOT WORKING DURING TEST T/S FOUND M10699 BAD AT RT ROW 22. REMOVED AND REPLACED CHARGER AND BATTERY. OPS CHECK NORMAL AT THIS TIME.SDR CALA2009102000635Charger · inoperativeDURING NR 3 SERVICE CHECK INSPECTION FOUND CABIN EMERGENCY LIGHTS ROW 15-24 INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY CHARGER, OPS CHECK NORMAL.SDR CALA2009012600055Rotary Actuator · inoperativeLEADING EDGE SLAT DISAGREE LIGHT ILLUMINATED DURING CLIMBOUT, PERFORMED ABNORMAL CHECKLIST. SLAT WOULD NOT RETRACT, RETURNED TO AIRPORT (EWR). REMOVED AND REPLACED NUMBER 11 AND 13 ROTARY ACTUATORS PER AMM 27-81-18. OPERATIONAL CHECKS NORMAL.SDR CALA0700695Fitting · crackedREF EA 5440-01234 REV B OP 11 FASTENER 20 HAS CRACK INDICATION, NR 1 PYLON AFT BULKHEAD FITTING. REPAIRED PER ECRA 5450-01724.SDR CALA0600446Charger · inoperativeTHE EMERGENCY PATH LIGHTING AT ROWS 15 THROUGH 25, AND 23 DEF BULLNOSE LIGHT WERE FOUND INOPERATIVE. THE BATTERY CHARGER AT ROW 22 DEF WAS REPLACED AND OPERATIONAL CHECKS WERE GOOD IAW MM 33-51-07.SDR CALA0600204Battery · dischargedTHE EMERGENCY LIGHTS AT SEATS 15-25 WERE FOUND INOPERATIVE. THE BATTERY AND CHARGER AT SEAT 22 DEF WERE REMOVED AND REPLACED.SDR CALA0500205Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON UNDERSIDE OF UNDER ANCHOR NUT ATTACH PLATE AT BS 1681, LBL 52. REPAIRED IAW ECRA 5320-01781.SDR CALA0500206Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER STRUCTURE CORRODED AT BS 680, RBL 53. REPAIRED IAW SRM 53-00-51, FIGURE 201, REPAIR 3.SDR CALA0500197Floorbeam · corrodedINSPECTION FOUND UPPER CHORD OF FLOORBEAM CORRODED AT BS 720 FROM RBL 24-52. REPAIRED IAW SRM 53-00-51, FIGURE 201.SDR CALA0400466Circuit Card · faultyTHE FLIGHT ATTENDANTS REPORTED SMOKE/HAZE AND SMOKEY ODOR IN CABIN WHILE AT CRUISE. THE QRH PROCEDURE FOR SMOKE IN CABIN WAS COMPLETED AND THE GALLEY AND VIDEO EQUIPMENT CIRCUITS WERE DEACTIVATED. THE HAZE CEASED, BUT THE ODOR REMAINED. THE AIRCRAFT LANDED SDR CALA0200592Circuit Board · faultyTHE FIRE WARNING BELL SOUNDED CONTINUOUSLY WITH NO OTHER INDICATIONS AFTER TAKEOFF FROM EWR. THE WARNING SILENCED AFTER PULLING AND RESETTING B18 (WARN ELE B) CIRCUIT BREAKERS. THE FLIGHT CONTINUED TO FLL WHERE IT LANDED WITHOUT FURTHER INCIDENT. NO EVIDENCSDR CALA0000339Oven · inoperativeSMOKE APPEARED IN THE AFT CABIN SHORTLY AFTER TAKEOFF FROM SDQ. THE CIRCUIT BREAKER FOR THE NR 3 OVEN IN AFT GALLEY WAS PULLED AND THE SMOKE CEASED. THE AIRCRAFT WAS RETURNED TO SDQ WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 3 OVEN AT FAULT.
Back to N12109