N12142
Service difficulty reports · 91
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12142' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12142' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20261014002Placard · missingRT EMERGENCY EXIT WINDOW INTERIOR PLACARD MISSING. INSTALLED RT EMERGENCY EXIT WINDOW INTERIOR PLACARD AS REQUIRED.SDR JJBA20260805002Inverter · inoperativeNR 2 EMERGENCY LIGHT BATTERY LOWER INVERTER INOPERATIVE. REMOVED AND REPLACED LOWER INVERTER AT NR 2 EMERGENCY LIGHT BATTERY. OPS CHKD GOOD.SDR JJBA20260423017Battery Pack · misinstalledSEVERAL EMERGENCY LIGHTS INOPERATIVE. FOUND #3 BPS NOT INSTALLED CORRECTLY. REINSTALLED. OPS CHECK GOOD.SDR JJBA20250623016Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECK FAILED. SUSPECT BAD HOUSING. REMOVED AND REPLACED LIGHT ASSEMBLY HOUSING. OPS CHECK SAT.SDR JJBA20250623015Sign · inoperativeEXIT LOCATING SIGN MID CEILING FWD INOPERATIVE. REMOVED AND REPLACED EXIT LOCATING SIGN FWD SIDE MID CEILING. OPS CHECK SAT.SDR JJBA20250417059Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. FOUND LIGHT COVER BROKEN WHEN CHANGING BULB ON LIGHT. REMOVED AND REPLACED BULB AND LIGHT COVER ON SERVICE DOOR EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250401039Lamp · inoperativeLH AFT EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH AFT EXTERIOR EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250303008Lamp · inoperativeLH LOWER EXT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LH LOWER EXT EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20241118005Battery Pack · inoperativeSEVERAL EMERGENCY LIGHTS OUT. REMOVED AND REPLACED EMERGENCY BATTERY #2. OPS CHECK SAT.SDR JJBA20240528059Duct · unsecureSMELL OF SMOKE (BURNING RUBBER) ON CLIMB OUT WITH EXCESSIVE AMOUNTS OF CONDENSATION FROM #1 PACK. FOUND BOTH NACA RAM AIR INLET DUCTS (191GL), NOT SECURED; RH PACK DUCT FROM NACA AIR INLET WAS TORN; REMOVED AND REPLACED DUCT. LH PACK DUCT FROM NACA AIR INLET WSDR JJBA20240523058Floor Support · corrodedCENTER FUSELAGE 1 - RH OMEGA BEAM UPPER SURFACE - BETWEEN FR18 - FR19 - CORROSION. PROCEEDED TO FABRICATE DOUBLE AND INSTALLED DOUBLER.SDR JJBA20230530020Sensor · inoperativeFLAP FAILURE ON APPROACH, FLAP STOPPED AT 38 DEGREES. RESET FLAPS. EICAS MESSAGE CLEARED AND FLAPS OPS CHECKED NORMAL. PERFORMED GVI OF FFL. LH FLAP VELOCITY SENSOR CANNON PLUG BACKSHELL WAS FOUND LOOSE, RESECURED. REACTIVATED SYSTEM BY REINSTALLING CONNECTS PSDR JJBA20230320026Lamp · inoperativeMAIN CABIN DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB ON MCD EMERGENCY LIGHT. OPS CHECK FAIL. LIGHT ASESEMBLY FOUND TO BE INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOODSDR JJBA20230320025Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. DETERMINED FAULT TO BE BAD BATT 1 AND 4. REMOVED AND REPLACED BOTH BATTERIES. OPS CHECK SAT
BATTERY PACK #4 PN: ABS-2013-1A SN 61249 TSN 3920.06 CSN: 3300 TIME SINCE: 3198.54SDR JJBA20220921026None · failedSUPPLEMENTAL (NEW) INFORMATION: REMOVED AND REPLACED NOSE LANDING GEAR. OPS AND LEAK CHECK SAT.SDR JJBA20220502012None · noneREAR FUSELAGE SKIN HAS CORROSION UNDER #2 RAT ANTENNA ON EXTERNAL AND INTERNAL SURFACES. REPAIRED REAR FUSELAGE SKIN UNDER #2 RAT ANTENNA.SDR JJBA20220420009None · noneREAR FUSELAGE SKIN HAS CORROSION UNDER #2 RAR ANTENNA ON EXTERNAL AND INTERNAL SURFACES. REPAIRED REAR FUSELAGE SKIN UNDER #2 RAR ANTENNA.SDR JJBA20220412008None · noneLH OMEGA BEAM AT FR 38 - FR 44 HAS CORROSION AROUND SURFACE OF FASTENER HOLES. REMOVED AND REPLACED LH OMEGA BEAM.SDR JJBA20220325011None · noneCORROSION FOUND ON THE OMEGA BEAM LOCATED BETWEEN FR59 TO FR 61, Y.00-19. REPAIRED OMEGA BEAM AT FR 59 - FR61 AND Y.00-16SDR JJBA20220325010None · noneCORROSION FOUND ON THE OMEGA BEAM LOCATED BETWEEN FR59 TO FR 61. REPAIRED OMEGA BEAM AT FR 59 - FR61 AND Y.00+16SDR JJBA20211024054Inverter · faultyEXIT MARKING ASSEMBLY FORWARD OF SEAT 3C INOPERATIVE. SWAPPED EXIT MARKING WITH EXIT SIGN ABOVE FA SEAT. FAULT DID NOT FOLLOW. SWAPPED EMERGENCY LIGHT DC/AC INVERTER. FAULT FOLLOWED #3 INVERTER. ALL PARTS RETURNED TO ORIGINAL POSITION. R&R EMERGENCY LIGHT INVESDR JJBA20210920031Battery · inoperativeRH FWD EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT LIGHT PLACARD ASSEMBLY. OPS CHECK BAD. R&R CHASSIS ASSEMBLY AND BATTERY PACK. OPS CHECK SATSDR JJBA20210316012Light · inoperativeRH FWD WING TO FUSELAGE EMERGENCY LIGHT INOPERATIVE. R&R RH FWD WING TO FUSELAGE EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20211110012Seat · crackedSEATS 2A, 3A, 4A, 8A, 9A, 11A, 19A, 22A, AND 23A ALL HAVE A CRACK IN THE RADIUS OF THE BASE ASSEMBLY BELOW THE AISLE SIDE ARM REST. REPLACED SEATS 2A, 3A, 4A, 8A, 9A, 11A, 19A, 22A, AND 23A.SDR JJBA20201229034Skin · dentedSUSPECTED DENT FOUND ON CENTER FUSE II, BETWEEN FR 27-28 AND BETWEEN STR 1L-2L. DENT ON CENTER FUSE II, BETWEEN FR 27-28 AND BETWEEN STR 1L-2L REPAIRED.SDR JJBA20201216033Skin · dentedDENT ON LT FWD FUSE II, BETWEEN CUT OUT EXTERNAL POWER RECEPTACLE AND STR 15L. PAINT REMOVED AT DENTED AREA. AFTER INVESTIGATION, A CHAFING IS FOUND ON LT FWD FUSE 2, BETWEEN FR 6-7 AND BETWEEN STR 13L-15L. ON LT FWD FUSE II, BETWEEN CUT OUT EXTERNAL POWER SDR ASOA202009124023SLight · inoperativeMAINTENANCE REMOVED AND REPLACED THE AFFECTED LIGHT ASSEMBLY FOR SEATS 19A-21A. OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA2020091424023Socket · burnedBHM-FLIGHT 4369, THE CREW REPORTED SMELL OF SMOKE AND VISIBLE SMOKE ON SIDEWALL LIGHT PANEL 20A WITH A VISIBLE BURN MARK. THE AIRCRAFT LANDED IN BHM WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT. DEACTIVATED LIGHT ASSEMBLY AT SEAT 20A AND PLACE ISDR RAIA2020031100001Support · corrodedDISCOVERED SURFACE CORROSION ON FUSELAGE SERVICE DOOR CUTOUT THRESHOLD SUPPORT STRUCTURE AROUND FLOOR TRIM NUTPLATE LOCATIONS----REMOVED AND REPLACED ITEM WITH NEW ITEMSDR RAIA2020031080002Shear Tie · crackedSHEAR CLIP FRAME AT STR 18L-19L IS CRACKED ......REMOVED AND REPLACED SHEAR CLIP AT STR 18L=19LSDR RAIA2020031080001Angle · corrodedCARGO Z ANGLE IS CORRODED..........REMOVED AND REPLACED CARGO Z ANGLESDR RAIA2019121760001Unknown · odorELECTRICAL SMELL IN COCKPIT.CREW REPRTS A FAINT ELECTRICAL SMELL AND SMOKE VENTING INTO COCKPIT THROUGH CAPTS FWD WINDSHIELD SEAL ON THE LH SIDE.SMELL AND SMOKE DISSIPATED WITHIN 90 SEC. FA REPORTS THAT SHE COULD ONLY DETECT SMELL AT THE COCKPIT DOOR AND NOT TSDR RAIA201907270002Thermostat · malfunctionedBLEED 1 & 2 OVERTEMP DURING CLIMBOUT IN ICING( EMER DECLARED). R&R #2 FAN AIR VALVE HIGH TEMP THERMOSTAT AND #2 LOW TEMP THERMOSTAT INLET HOSE, ALL OPS CHECK GOOD.SDR RAIA2019032200001Button · defectiveRUDDER SYSTEM 1-2 INOP MESSAGE AFTER YAW DAMPER FAIL MESSAGE. WENT AWAY, CAME BACK THEN WENT AWAY. SYS 1 PRESSURE 3100. SYSTEM 2 3000. REFER TO DISCREPANCY 1, LOG PAGE 471478. R & R RUDDER SHUT OFF PUSH BUTTONS FOR SYSTEM 1 AND 2. OPS CHECK GOOD. MORE INFORMATSDR RAIA201812120001Connector · burnedLAV SMOKE EICAS ON TAKE OFF. FOUND CONNECTOR P8100 BURNT. R&R PLUG. OPS CHECK GOOD.SDR RAIA2018090670001Carbon Seal · leakingAT 290 SMOKE IN CABIN AND FLT DECK. NOTE FILLED FROM AFT TO FORWARD. UPON INSPECTION FOUND 0 CARBON SEAL LEAKING AND SHAFT SEAL SPINNER LOOSE. REFERENCE STANDARD PAPERWORK FOR DISPOSITION. DETAILS OF THIS REPAIR HAVE BEEN EMAILED TO 9-AMC-SDR-PROGMGR@FAA.GOV, SDR RAIA201801120001Sensor · dirtyNR 1 AND 2 BLEED OVERTEMP. CLEANED THE TEMP SENSORS AND PERFORMED AN OPS CHECKED GOOD.SDR RAIA201709010002Bulb · inoperativeCEILING AISLE FLOOD LIGHT AT ROW 12 INOPERATIVE. R & R THE BULBS, OPS CHECKED GOOD.SDR RAIA201703120001Fcu · inoperativeFLAP FAIL MESSAGE INFLIGHT. R & R THE FECU, OPS CHECKED GOOD. ACFT FOR SERVICE.SDR RAIA201612090001Power Supply · inoperativeLEFT EXTERIOR FWD EMERGENCY LIGHT INOPERATIVE. R & R THE NR 1 BATTERY POWER SUPPLY, OPS CHECKED GOOD.SDR ASOA20160329012Skin · damagedLIGHTNING STRIKE AT FRAME 29 BETWEEN STR 15L AND 16L. CUTOUT DAMAGED AREA, FABRICATED DOUBLER AND FILLER. INSTALLED IAW SRM 53-22-01. ACFT RELEASED AND RETURNED TO SERVICE.SDR ASOA20160301016HPower Supply · inoperativeTHE LT FWD EMERGENCY LIGHT ON PANEL 191 WAS FOUND TO BE INOPERATIVE. MAINTENANCE R & R THE NR 1 EMERGENCY LIGHT POWER SUPPLY, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20160105001Tank · chafedACFT IS IN FOR A C-CHECK INSPECTION. INSPECTION FOUND THE VENTRAL TANK CHAFE AT A PREVIOUS LOWER SKIN PATCH BETWEEN TANK DRAINS. THE OLD DOUBLER HAS BEEN REMOVED AND BLENDED SMOOTH, FABRICATED A NEW DOUBLER FOLLOWING THE INSTRUCTIONS OUTLINED ON EC 2015-145-SDR ASOA20141021119Wire Harness · odorCREW REPORTED A BURNING ODOR NEAR SEAT 4A DURING TAKEOFF AND LANDING. MAINTENANCE R & R THE CABIN LIGHT WIRE HARNESS WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140922106Charger · inoperativeDURING MX INSPECTION, THE FWD LT SIDE EXTERIOR EMERGENCY LIGHT WAS FOUND INOPERATIVE. MX R & R THE NR 1 EMERGENCY LIGHT SYS BATTERY CHARGER ASSY WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA201400710213Inverter · inoperativeDURING RON ROUTINE MAINTENANCE, SEVERAL EMERGENCY LIGHTS IN THE COCKPIT AND FORWARD CABIN WERE FOUND INOPERATIVE DURING FUNCTIONAL TEST. MAINTENANCE R & R THE NR 1 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20131123445Floor Support · crackedRT OMEGA BEAM OTBD CRACKED AT FRAME 47. R & R OMEGA BEAM.SDR ASOA20131123444Floor Support · crackedRT OMEGA BEAM, INBD, AT FRAME 47 CRACKED. R & R OMEGA BEAM.SDR ASOA20131123443Frame · crackedWHILE INSTALLING SHEAR TIE FOUND CRACK IN FRAME 25 BETWEEN STRINGER 15 & 16R. TRIMMED CRACK, FABRICATED AND INSTALLED REPAIR DOUBLER/FILLER IAW ETD2013-145-059433A.SDR ASOA20131123442Shear Tie · crackedSHEAR TIE CRACKED AT FRAME 25 BETWEEN STRINGER 15 & 16R. R & R SHEAR TIE
Back to N12142