N128BZ

Service difficulty reports · 18

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N128BZ' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR BAGA2027072700001Power Supply · failedFLIGHT DECK EMERGENCY LIGHT DOES NOT COME ON WHEN THE EMERGENCY LIGHTS ARE SELECTED ON. REMOVED AND REPLACED THE FWD RH ELPU.Jul 24, 2026 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR BAGA2025091900002Handle · out of positionEMERGENCY EXIT LH OPEN EICAS INDICATION DURING CLIMB. RETURNED BACK TO FIELD AT MCN. RESET LH OVERWING EMERGENCY EXIT DOOR HANDLE.Sep 19, 2025 · N128BZ · Emb ERJ190100IGW · Emergency ExitsSDR BAGA2024062500004Shutoff Valve · failedBLEED 2 FAIL, LOSS OF CABIN PRESSURIZATION CONTROL DUE TO BLEED 1 ON MEL. EMERGENCY DECLARED AND RETURNED TO FIELD. CREW OXYGEN DEPLOYED. FINAL INDICATION 1100 PSI. PASSENGER MASKS WERE NOT DEPLOYED.REMOVED AND REPLACED NPRSOV.Jun 23, 2024 · N128BZ · Emb ERJ190100IGW · Cabin Pressure Control SystemSDR BAGA2023091800010Unknown · unknownCORROSION AROUND FASTENER HOLES - PNL 192CR AT MULTIPLE LOCATIONS - ZONE 100 CORRECTIVE ACTION- PANEL REPLACEDAug 29, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Structure (General)SDR BAGA2023091800009Unknown · unknownCORROSION ON FLOOR SUPPORT AT FR 13 AND Y-11. CORRECTIVE ACTION - REMOVED AND REPLACE DAMAGE FLOOR SUPPORT/DOUBLER AT FR 13 AND -11Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR BAGA2023091800008Floor Support · corrodedCORROSION ON ENTRY WAY 9 HOLE FLOOR SUPPORT AROUND FASTENER HOLE AT FR 17 AT Y-13 CORRECTIVE ACTION - REMOVED AND REPLACED 9 HOLE FLOOR SUPPORT PN170-12118-001 AT FRAME 17 Y-13 IAW EMB 190 SRM 51-40-08Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Main, StructureSDR BAGA2023091800007Unknown · unknownWET AREA FLR SUPPORT STRUCTURE – SILL – RH BETWEEN FR 84 AND FR 85 AND Y +36 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION – REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE SILL RH BETWEEN FR 84 AND FR 85 AND Y+36 PER E-190 SRM 51-40-08Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR BAGA2023091800006Unknown · unknownWET AREA FLR SUPPORT STRUCTURE BEAM RH I/B BETWEEN FR 86 AND FR 87 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTIONS - REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE BEAM RH I/B BETWEEN FR 86 AND FR 87 AND Y - 10 PER EMB 190 SRM 51-40-08Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR BAGA2023091800005Unknown · unknownWET AREA FLR SUPPORT STRUCTURE – BEAM – LH I/B BETWEEN FR 88 AND FR 89 AND Y – 10” HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION – REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE BEAN LH I/B BETWEEN FR 88 AND FR 89 PER E-190 SRM 51-40-08Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR BAGA2023091800004Unknown · unknownWET AREA FLR SUPPORT STRUCTURE - CNTR SILL - AT FR 88 AND Y = 0 HAS CORROSION ON MULTIPLE LOCATIONS. CORRECTIVE ACTION: REMOVED AND REPLACED WET AREA FLR SUPPORT STRUCTURE - CENTER SILL AT FR 88 AND Y = 0 PER EMB 190 SRM 51-40-08.Aug 19, 2023 · N128BZ · Emb ERJ190100IGW · Fuselage Miscellaneous StructureSDR BAGA2023091800003Power Supply · inoperativeRH MIDDLE EXTERNAL EMERGENCY LIGHT INOP CORRECTIVE ACTION REMOVED AND REPLACED #4 ELPU FOR RH MIDDLE EXTERNAL EMERGENCY LIGHT PER REF EMBRAER 190 AMM 33-50-01. OPS CHECK GOOD. #4 ELPU REMOVED PN-3400-22--10 SN-002752. INSTALLED PN-3400-22-10 SN--001926.Aug 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR BAGA2023091800002Power Supply · dischargedBOTH FWD AND MIDDLE LH EXTERNAL EMERGENCY LIGHTS INOP - REMOVED AND REPLACED BOTH #4 AND #5 ELPU FOR THE FWD AND MIDDLE LH EXTERNAL EMERGENCY LIGHTS PER REF EMBRAER 190 AMM 33-50-01. #4 INSTALLED PN-- 3400-22-10 SN-001926, REMOVED PN-3400-22-- 10 SN-00002752.Aug 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR BAGA202306190001Power Supply · unserviceableRIGHT HAND OVERWING EMERGENCY EXIT IDENTIFIER SIGN, DOES NOT ILLUMINATE DURING MX, EMERGENCY LIGHT OPERATIONAL TEST. REMOVED AND REPLACE CENTER FUSELAGE II, FWD EMERGENCY LIGHT BATTERY (#3 BATT) REF E190AMM 33-50-01. PERFOMRED CABIN EMERGENCY LIGHT TEST, ALJun 16, 2023 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR BAGA2023122000027Unknown · unknownTHIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. PILOT REPORTED THAT THE R2 SERVICE DOOR WAS DIFFICULT TO ARM/DISARM. PERFORMED OPERATIONAL CHECKS AND TROUBLESHOOTING. NO FAULTS FOUND.Jan 20, 2023 · N128BZ · Emb ERJ190100IGW · Emergency EquipmentSDR BAGA2023122000023Battery · dischargedTHIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. #6 EMERGENCY LIGHT POWER SUPPLY NOT FUNCTIONING CORRECTLY. REPLACED BATTERY.Dec 20, 2022 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR BAGA2023121900010Shutoff Valve · failedTHIS SDR SUBMITTED LATE DUE TO AUDIT FINDINGS. BRAKE FAULT MESSAGE ON EICAS. OBSERVED OUTBOARD BRAKES NOT WORKING ON OP CHECK. BCM1 SOV TEST FAILED. REPLACED BRAKE SOV VALVE.Sep 14, 2022 · N128BZ · Emb ERJ190100IGW · Landing Gear Brake SystemSDR BAGA2023121900008Battery · dischargedTHIS SDR SUBMITTED LATE DUE TO AUDIT FINDING. #1 EMERGENCY LIGHT BATTERY FAULTED DUE TO POWER SUPPLY. BATTERY REPLACED.Aug 19, 2022 · N128BZ · Emb ERJ190100IGW · Emergency LightingSDR 2022FA0000330None · failedFLAP FAIL CAUTION MESSAGE ON EICAS AFTER SELECTING FLAPS ZERO AFTER TAKEOFF, RAN QRH PROCEDURE BUT WERE UNABLE TO CLEAR THE MESSAGE - REMOVED AND REPLACED SFACE 2 IAW AMM 27-53-02/400.PERFORMED OPERATIONAL CHECK NUMEROUS TIMES IAW AMM 27-50-00-710-801-A, ALLJul 5, 2022 · N128BZ · Emb ERJ190100IGW · Trailing Edge Flap Control System
Back to N128BZ