What was found
CORROSION ON ENTRY WAY 9 HOLE FLOOR SUPPORT AROUND FASTENER HOLE AT FR 17 AT Y-13 CORRECTIVE ACTION - REMOVED AND REPLACED 9 HOLE FLOOR SUPPORT PN170-12118-001 AT FRAME 17 Y-13 IAW EMB 190 SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON ENTRY WAY 9 HOLE FLOOR SUPPORT AROUND FASTENER HOLE AT FR 17 AT Y-13 CORRECTIVE ACTION - REMOVED AND REPLACED 9 HOLE FLOOR SUPPORT PN170-12118-001 AT FRAME 17 Y-13 IAW EMB 190 SRM 51-40-08