N13132

Service difficulty reports · 74

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N13132' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20210823052Battery Pack · inoperativeBOTH LH EMERGENCY LIGHT, RH OVER WING EMERGENCY LIGHT MAIN CABIN DOOR EMERGENCY LIGHTS ALL INOPERATIVE. REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY. OPS CHECK SAT.Aug 23, 2021 · N13132 · Emb EMB145XR · Emergency LightingSDR JJBA202108030028Battery Pack · inoperativeLEFT AND RIGHT OVERWING EMERGENCY LIGHT NOT WORKING. R&R #3 EMERGENCY BATTARY. OPS CHECK SATJul 30, 2021 · N13132 · Emb EMB145XR · Emergency LightingSDR JJBA20210730027Light · intermittentEMERGENCY LIGHT ON MAIN DOOR IS WORKING INTERMITTENLY. REMOVED AND REPLACED MAIN DOOR EMERGENCY LIGHT ASSY. OPS CHECK GOOD.Jul 30, 2021 · N13132 · Emb EMB145XR · Emergency LightingSDR JJBA20210404010Armrest · crackedFOUND CRACK IN PAX SEAT ARMREST AT 6A, 8A, 9A, 10A, 11A, 18A, 19A, 23A, 24A. R&R SEAT ASSEMBLY AT 6A, 8A, 9A, 10A, 11A, 18A, 19A, 23A, 24AApr 4, 2021 · N13132 · Emb EMB145XR · Passenger Compartment EquipmentSDR JJBA20201114009Connector · unsecureCABIN EMERGENCY ICU LIGHT ILLUMINATED AND WILL NOT EXTINGUISH. RESECURED PLUG ON FWD F/A PHONE. OPERATIONS CHECK SATISFACTOR. NO DEFECTS NOTED.Nov 14, 2020 · N13132 · Emb EMB145XR · Emergency LightingSDR JJBA20200924036Skin · dentedMULTIPLE DENTS ON RT CENTER FUSE 4, BETWEEN FR 53-54 AND BETWEEN STR 12R-14R. RT FUSELAGE 4, BETWEEN FR 53-54 STR 12R-13R, 2 CUT-OUT PERFORMED FOR ENGINE REVIEW. RT FUSELAGE BETWEEN FR 53-54 AND BETWEEN STR 12R-14R REPAIRED. RT CABIN OVERHEAD BIN RE-INSTALLSep 24, 2020 · N13132 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR RAIA2020011109001Bolt · looseAFTER TAKE OFF, GEAR WOULD NOT COME UP. EICAS MESSAGE: LDG AIR/GROUND FAIL. AFTER LANDING, IC 1-2 INOP. FOUND R/H MLG WOW #2 BRACKET BOLT EXCESSIVELY LOOSE. REMOVED SAFETY, TIGHTENED BOLT, AND RESAFTIED. OPS CHECK GOOD ON 2 GEAR SWINGS.Jan 9, 2020 · N13132 · Emb EMB145XR · Landing Gear Retraction/Extension SystemSDR RAIA2019082510002Floor Support · corrodedR/H FLOOR SILL BETWEEN FR 53-59 HAS CORROSION. REMOVED AND REPLACED R/H FLOOR SILL.Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA201908241010Floor Support · corrodedR/H FLOOR SILL HAS CORROSION BETWEEN FR 42-47.......REMOVED AND REPLACES R/H FLOOR SILLAug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019082150001Shear Tie · crackedL/H SHEAR TIE AT FR 65 IS CRACKED. R&R LT SHEAR TIE AT FR 65Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019082110009Floor Support · corrodedL/H FLOOR SILL HAS CORROSION BETWEEN FR 15 AND FR 23. R & R LT FLOOR SILL AT FR 15-23Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019082100009Door Frame · corrodedSVC DOOR CUTOUT LWR THRESHOLD FR REPAIR DOUBLER AT FR 20 HAS CORROSION AROUND NUTPLATE. REMOVED AND REPLACED REPAIR DOUBLERAug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Main, StructureSDR RAIA2019081910007Floor Support · corrodedR/H FLOOR SILL HAS CORROSION BETWEEN FR 33-35. REMOVED AND REPLACED R/H FLOOR SILL.Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081910006Floor Support · corrodedR/H FLOOR SILL HAS CORROSION BETWEEN FR 36-41. REMOVED AND REPLACED R/H FLOOR SILL....Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081910005Sign · corrodedR/H STOP SIGN FLOOR HAS CORROSION AT FR 22.... REMOVED AND REPLACED R/H STOP SIGN NEAR SVC DOORAug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081910004Floor Support · corrodedL/H FLOOR SILL HAS CORROSION BETWEEN FR 29-35. REMOVED AND REPLACED R/H FLOOR SILLAug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081710003Floor Support · corrodedR/H FLOOR SILL HAS CORROSION BETWEEN FR 23-29. REMOVED AND REPLACED R/H FLOOR SILL.Aug 11, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019082710012Shear Tie · crackedSHEAR CLIP AT RF 80 BETWEEN STR 4L- 5L IS CRACKED. R & R SHEAR CLIP.Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019082510011Shear Tie · crackedAFT CARGO COMP FRAME 66 SHEAR CLIP IS CRACKED ABOVE CARGO DOOR CUT OUT BETWEEN STR 5&6 L/H SIDE. REMOVED AND REPLACED SHEAR CLIP AT FR 66Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019082100010Bracket · crackedCARGO DOOR TORSION BAR AFT SUPPORT BRACKET LOWER BRACKET IS CRACKED. R & R CARGO DOOR TORSION BAR AFT SUPPORT BRACKETAug 10, 2019 · N13132 · Emb EMB145XR · Cargo/Baggage DoorsSDR RAIA2019082011008Floor Support · corrodedL/H FLOOR SILL HAS CORROSION BETWEEN FR 42 -47. REMOVED AND REPLACED R/H FLOOR SILL AT FR 42-47Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019082001008Shear Tie · crackedMAIN CABIN FRAME 16 R/H SHEAR CLIP IS CRACKED AT DTR 15 RIGHT. REMOVED AND REPLACED SHEAR CLIP.Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019081900007Support Bracket · crackedAFT CARGO DOOR THRESHOLD T PROFILE SUPPORT BRACKET IS CRACKED AT FR 66...... REMOVED AND REPLACED AFT CARGO DOOR THRESHOLD T PROFILEAug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081700006Gusset · corrodedL/H GUSSET HAS CORROSION BETWEEN FR15 AND FR 18. PERFORMED REPAIR ON L/H GUSSET BETWEEN FR 15 AND FR 18.Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR RAIA2019081700005Doubler · damagedL/H FR 15-14 DOUBLER PLATE GROMMET HOLE ELONGATED. REMOVED AND REPLACED DOUBLER PLATE ON L/H FR 15-14Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Main, StructureSDR RAIA2019081700004Shear Tie · crackedAFT CARGO COMP FRAME 73 SHEAR CLIP IS CRACKED BETWEEN STR 6 AND 7 L/H SIDE. REMOVED AND REPLACED SHEAR CLIP.Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019081700003Shear Tie · crackedAFT CARGO COMP FRAME 73 SHEAR CLIP IS CRACKED BETWEEN STR 7 AND 7 L/H SIDE.... REMOVED AND REPLACED SHEAR CLIP...Aug 10, 2019 · N13132 · Emb EMB145XR · Fuselage Internal Mounting StructureSDR RAIA2019081700002Wedge · crackedR/H WING STUB AFT WED IS CRACKED IN 2 PLACES.... REMOVED AND REPLACED R/H WING STUB AFT WEB.Aug 10, 2019 · N13132 · Emb EMB145XR · Wing Main, Frame StructureSDR RAIA201905150001Door Seal · lack of lubeON POST FLIGHT, MAIN CABIN DOOR DIFFICULT TO OPEN. LUBRICARED SEAL. OPS CHECK GOOD. RESISTANCE < 50 LBS.May 15, 2019 · N13132 · Emb EMB145XR · Passenger/Crew DoorsSDR RAIA201709240001Lens · crackedPAX DOOR SWING ARM EMERGENCY LIGHT LENS IS CRACKED. R & R THE LENS, OPS CHECKED GOOD.Sep 24, 2017 · N13132 · Emb EMB145XR · Emergency LightingSDR RAIA201708290001Battery Pack · inoperativePAX DOOR EMERGENCY LIGHT INOPERATIVE. R & R THE EMERGENCY LIGHT BATTERY PACK POS 1, OPS CHECKED GOOD.Aug 29, 2017 · N13132 · Emb EMB145XR · Emergency LightingSDR RAIA201708150001Window Frame · corrodedCAPTAINS WINDSHIELD FRAME HAS CORROSION. R & R CAPTAINS WINDSHIELD, OPS CHECK GOOD.Aug 15, 2017 · N13132 · Emb EMB145XR · Flight Compartment WindowsSDR RAIA201611180001Outflow Valve · inoperativeAUTO PRESSURIZATION FAIL & UNABLE TO MANUALLY CONTROL PRESSURIZATION. R & R ELECTROPNEUMATIC OUTFLOW VALVE.OPS CHECKED GOOD.Nov 18, 2016 · N13132 · Emb EMB145XR · Pressure Regulator/Outflow ValveSDR RAIA201610120001Bulb · inoperativeEMERGENCY LIGHT AT ROW 22 INOPERTIVE. R & R THE BULB. OPS CHECKED GOOD.Oct 12, 2016 · N13132 · Emb EMB145XR · Emergency LightingSDR RAIA201604270001Fire Warning · activatedAPU FIRE INDICATION ON EICAS IN FLT.Apr 27, 2016 · N13132 · Emb EMB145XR · Fire DetectionSDR RAIA201603160001Warning Light · false activationAPU FIRE WARNING IN FLT WITH APU OFF, RETURN TO BLOCK. MAINTENANCE PERFORMED APU FIRE WARNING INSPECTION AND FOUND NO DEFECTS, ACFT RETURN TO SERVICED.Mar 16, 2016 · N13132 · Emb EMB145XR · Fire DetectionSDR RAIA201603010001Bulb · inoperativeCABIN EMERGENCY LIGHT NR 23 DOES NOT ILLUMINATE. RELAMPED CABIN EMERGENCY LIGHT AT SEAT 23. OPS CHECK GOOD.Mar 1, 2016 · N13132 · Emb EMB145XR · Emergency LightingSDR ASOA20150926179Beam · corrodedDURING C-CHECK, THE CARGO DOOR LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE BEAM IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 26, 2015 · N13132 · Emb EMB145XR · Fuselage Main, StructureSDR ASOA20150926178Door Frame · corrodedDURING C-CHECK THE LT EMERGENCY EXIT LOWER FRAME WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE FRAME IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 26, 2015 · N13132 · Emb EMB145XR · Fuselage Main, StructureSDR ASOA20150908051Flashlight · inoperativeTHE FLASHLIGHT BEHIND THE CAPTAINS SEAT WAS REPORTED TO BE NOT WORKING. MAINTENANCE R & R THE CAPTAINS FLASHLIGHT ASSY WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Sep 8, 2015 · N13132 · Emb EMB145XR · Emergency EquipmentSDR ASOA20141211147HFan · inoperativeTHE CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE COCKPIT AND CABIN. THE ACFT DIVERTED WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE ACFT AND FOUND THE COCKPIT RECIRCULATING FAN TO BE CAUSING THE BURNING ODOR. THE FAN WAS DEACTIVATED AND PLADec 11, 2014 · N13132 · Emb EMB145XR · Air Distribution FanSDR ASOA20131001390Skin · scratchedDURING C-CHECK, LT SIDE FUSELAGE SKIN WAS FOUND WITH SIX SCRATCHES FRAMES 22 AND 23. APPROXIMATELY 135" IN AREA. BLENDED OUT AREA IAW SRM 53-21-01. FOUND TO BE OUT OF LIMITS. REPAIRED IAW EC 5320-01845.Oct 1, 2013 · N13132 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR ASOA20131001389Structure · gougedDURING C-CHECK, ACCESS DOOR 272DR WAS FOUND GOUGED AT THE HANDLE CUTOUT AREA. MX REMOVED GOUGE IAW EC 5240-01069. COMPLIED WITH A HFEC EDDDY CURRENT AND NO CRACKS FOUND. CLEANED, PREPED AREA AT HANDLE, ALLODINED AND PAINTED AREA IAW CPM 51-21-04.Oct 1, 2013 · N13132 · Emb EMB145XR · Service DoorsSDR ASOA20130930388Floor Support · crackedRIGHT OMEGA BEAM SUPPORT CRACKED. R & R RIGHT OMEGA BEAM SUPPORT.Sep 29, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20130930387Crossbeam · corrodedCENTER AISLE CROSSBEAM CORRODED BEYOND LIMITS. R & R CROSSBEAM.Sep 29, 2013 · N13132 · Emb EMB145XR · Fuselage Main, StructureSDR ASOA20130930386Floor Support · corrodedCORROSION BEYOND LIMITS AFTER BLEND OUT AROUND NUT PLATE CENTER AISLE FLOOR FRAME. FABRICATED FILLER/EXTERNAL ANGLE AND INSTALLED.Sep 29, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20130926384Gusset · corrodedLEFT GUSSET HAS CORROSION BEYOND LIMITS. R & R GUSSET.Sep 25, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20130926383Gusset · corrodedCENTER GUSSET CORRODED HAS CORROSION BEYOND LIMITS. R & R CENTER FLOOR GUSSET.Sep 25, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20130926382Gusset · corrodedRT GUSSET CORRODED BEYOND LIMITS. R & R GUSSET.Sep 25, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR ASOA20130926381Floor Support · corrodedRIGHT OTBD FLOOR SUPPORT CORRODED BEYOND LIMITS AFTER BLEND OUT. R & R FLOOR SUPPORT.Sep 25, 2013 · N13132 · Emb EMB145XR · Fuselage Miscellaneous Structure
Back to N13132