N1381A
Service difficulty reports · 382
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1381A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1381A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021021700337Depressor · damagedMAIN DECK CARGO DOOR AFT UPPER SEAL DEPRESSOR DAMAGED. REMOVED AND REPLACED DAMAGED SEAL DEPRESSOR AT MAIN CARGO DOOR AFT UPPER SIDE PER B767-300 AMM 20-11-00-910-802.SDR UIEA2021021700338Seal · damagedENGINE NR 2 DRAIN SEAL DAMAGED. PREPARED, CLEANED AND REPAIRED DAMAGED SEAL AT NR 2 ENG BY DRAIN AREA PER B767-300 AMM 78-00-00-038-N00.SDR UIEA2021021700339Handle · unlatchedF/O WINDOW OUTSIDE EMERGENCY TO OPEN HANDLE UNLATCHED. RESTOWED EMERGENCY OPEN HANDLE ON F/O NR 2 WINDOW IAW 767 AMM 25-61-00 56-11-04. PERFORMED OPS CHECK, OPS CHECK GOOD.SDR UIEA2021021700340Ceiling Panel · damagedL1 DOOR POSSIBLE OUT OF RIG. FOUND CEILING PANEL DAMAGED AT CREW ENTRY DOOR, SEE NR 34 FOR CORRECTIVE ACTIONS. PERFORMED CREW ENTRY DOOR CHECK IAW AMM 52-12-00, FOUND NORMAL.SDR UIEA2021021700341Sensor · malfunctionedAUTO BRAKES INOP. AUTO BRAKE SYSTEM 200/-300 AUTO BRAKES LIGHT NOT ILLUMINATED. NOTIFY DISPATCH A/C CAT III (RESTRICTED). REMOVED & REPLACED RT MLG TILT SENSOR S268 PER AMM 32-09-07/201. ADJUSTED MLG TILT SENSOR S268 PER AMM 32-09-07. AUTO BRAKE SYS TEST SDR UIEA2021021500322Controller · inoperative#2 RH FLIGHT DECK WINDOW HEAT NOT WARMING. TRANSFER TO MDDR # 142372 PER MEL 30-41-01-02, CAT C. DUE 23 FEB 21. DISPATCH NOTIFIED GTC 08:57A. LOG PG 12162219 ITM 9 - MIA T/S W/D 30-41-11 ALL WIRING READING CHECK OK; REMOVED AND REPLACED LH WINDOW HEAT CONTROSDR UIEA2021021200286Generator · inoperativeAPU GENERATOR INOP (APU GENERATOR, EXCEPT ER OPERATIONS BEYOND 120 MINUTES (NOTIFY DISPATCH)(<P>APU GENERATOR CONSIDERED INOP, ITEM TRANSFERRED TO MDDR 142290 IAW MEL 24-00-02B, CAT B, DUE 14FEB21.</P><P>14 FEB 21- LP 1216215 ITEM 3 - CVG - REMOVED AND REPLACESDR UIEA2021013000154Eicas · fault messageEICAS MAIN CARGO LOOP 1 AND LOOP 2 RAN THROUGH FIM 26-14 FT 809 FOR BOTH LOOP 1 AND 2. NO FAULTS NOTED AT THIS TIME. OK FOR SERVICE.SDR UIEA2021011200037Handle · unsecureCABIN EMERGENCY EXIT HANDLE NOT FULLY LATCHED ON FIRST OFFICERS SIDE. RE-SECURED HANDLE (EMERGENCY) ON FIRST OFFICERS SIDE. EMERGENCY EXIT HANDLE LATCHED AND LOCKED, IAW AMM 56-11-04. OPERATIONS CHECK GOOD AT THIS TIME. NO DEFECTS NOTED.SDR UIEA2021010500009O-Ring · leakingFUEL LEAKING FROM RT WING DRY BAY. REPLACED O-RINGS AND RETAINING RING, IAW AMM 28-22-07. PERFORMED ENGINE RUN LEAK CHECK. NO LEAKS NOTED.SDR UIEA2020113002473Warning Message · false activationFWD EQUIPMENT VALVE EICAS DURING TAXI IN, PER FIM 21-58 FT 805 A/C EXPERIENCED SHORT TERM POWER TRANSFER OPERATIONS, PER 21-58-00. OPERATIONS TEST FWD EQUIPMENT VALVE, PER AMM 21-58-00. CYCLED VALVE SWITCH TO STBY, OPERATIONS NORMAL.SDR UIEA2020110902366Pressure Switch · malfunctionedRIGHT AFT PRESSURE LIGHT IS OUT. TRANSFER TO MDDR 137297 MEL 28-22-01, DUE 16NOV20, CAT C. CONTINUITY CHECK OF GROUND WIRE, PIN 2 OF CONNECTOR D2822, CHECKS GOOD. JUMPERED PINS 2 & 3 ON CONNECTOR D2822, LIGHT IN F/D COMES ON. REQUIRES RT AFT BOOST PUMP PRESDR UIEA2020102902335Warning Light · false activationAFTER SHUTDOWN LT ENGINE VALVE REMAIN ILLUMINATED. LT ENGINE VALVE LIGHT EXTINGUISHED ON ITS OWN. PERFORMED DRY MOTOR AND IDLE RUN, IAW AMM 71-00-00. COULD NOT DUPLICATE FAULT. ENGINE PARAMETERS READ NORMAL. NO FAULTS NOTED AT THIS TIME.SDR UIEA2020102602308Unknown · malfunctionedWX RADAR INOPERABLE, WILL NOT SHOW WX RETURNS WITH EITHER LT OR RT SIDE. GROUND CLUTTER ONLY. PERFORMED OPERATIONAL TEST OF THE WXR SYSTEM, IAW AMM 34-43-00. NO FAULTS DISPLAYED. WEATHER SHOWS IN BOTH LT & RT SYSTEM. MCC NOTIFIED SYSTEM CHECKS OK, NO FAUSDR UIEA2020101202221Starter · inoperativeAPU INOPERABLE, ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60. TRANSFERRED TO MEL 49-11-01A, MDDR 135912, CAT C. 12OCT, CVG MX. REMOVED AND REPLACED APU STARTER MOTOR ASSEMBLY, IAW B767 AMM 49-41-01. OPERATIONS CHECK GOOD, LEAK CHECK GOOD. PERFORMED 3 SSDR UIEA2020100902200Radar · unreliableLT SYS RADAR UNRELIABLE. RT SYSTEM OK. TRANSFERRED TO MDDR 135742 PER MEL 34-43-01 CAT D. DUE 05JAN21 TI: CW AT 21:51Z. PERFORMED OPERATIONS CHECK OF LT WX RADAR SYSTEM, IAW AMM 34-43-00. OPERATIONS CHECK GOOD. THIS CLEARS DMI 135742, PLACARDS REMOVED.SDR UIEA2020101262178Relay · failedEICAS MESSAGE "CENTER LT FUEL PUMP" AFTER ENGINE START. BOTH CENTER PUMPS ON WITH ADEQUATE FUEL IN CENTER TANK. COMPLIED WITH THE QRH. TRANSFERRED TO MDDR 135604, PER MEL 28-22-02A, CAT "C", DUE 16 OCT 20 T/I 17:25Z JL. PLACARDS INSTALLED, C/B COLLARED. RSDR UIEA2020100852168Sensor · malfunctionedRIGHT ENGINE BLEED OVERHEAT RIGHT BLEED VALVE OFF ILLUMINATED IN FLIGHT. PERFORMED QRH PROCEDURE OVERHEAT LIGHT WOULD NOT EXTINGUISH. REPLACED RIGHT ENGINE (FATS) FAN AIR TEMP SENSOR, IAW MM 36-11-17. LEAKAGE TEST GOOD AND BITE TEST OK, AIR SUPPLY GOOD.SDR UIEA2020100852167Valve · malfunctionedRT ENGINE BLEED OVERHEAT EICAS ILLUM ON CLIMBOUT. ACCOMPLISHED QRH IN CRUISE AND BLEED SYSTEM RESET. SAME EICAS ILLUM ON DESCENT THROUGH 17,500 FT MSL. REMOVED AND REPLACED RIGHT ENGINE FAN AIR VALVE, IAW 36-11-16. FAMV CHECKS GOOD. ENGINE IDLE RUN. OK NSDR UIEA2020100842166Valve · malfunctionedREPEAT WRITE-UP: PASSING 5,000 MSL RT ENGINE BLEED OVERHEAT, RT ENGINE BLEED OFF, RT PACK OFF. RAN QRH, LIGHT EXTINGUISHED. PASSING 12,000 MSL IN CLIMB SAME INDICATIONS, QRH COMPLETED AGAIN. FLIGHT CONTINUED AT 15,000 MSL PER DUTY PILOT, MCC DISPATCH. T/S SDR UIEA2020100642161Switch · failedPASSING 3,000 MESSAGE RT ENGINE BLEED OVERHEAT, RT ENGINE BLEED OFF EICAS. RAN QRH, TURNED BLEED SWITCH OFF. REMOVED AND REPLACED RT ENGINE AIR SUPPLY OVERHEAT SW (S359), IAW B767 AMM 36-27-01. PERFORMED SATISFACTORY ENGINE RUN CHECK, IAW B767 AMM 71-00-00,SDR UIEA2020100642165Controller · intermittentDURING PNEUMATIC HEALTH CHECK FOUND INTERMITTENT ERRONEOUS READINGS FROM RT ENGINE HIGH PRESSURE CONTROLLER. REMOVED AND REPLACED RT ENGINE HPC, IAW AMM 36-11-08. OPERATIONS TEST GOOD AT THIS TIME, IAW AMM 36-23-00 AND EO 6736A013.SDR UIEA2020091081967Indication Sys · intermittentRT ENGINE FUEL FLOW IS INTERMITTENT. TRANSFERRED TO MEL 73-31-01-02, MDDR 133972, CAT C.SDR UIEA2020090801966Warning Message · false activationRIGHT ENGINE FUEL FLOW INDICATOR INOPERABLE, QUANTITY INDICATORS ALL INDICATE NORMALLY. PERFORMED FUEL FLOW TRANSMITTER INSPECTION IAW AMM 73-31-00, NO LEAKS FOUND. TRANSMITTER CONNECTOR PLUG IS RIGHT, NO DEFECTS FOUND. PERFORMED OPERATIONS CHECK IAW AMM 71SDR UIEA2020090101913Battery · failedDURING DAILY CHECK, EICAS MESSAGE "MAIN BATTERY CHGR". REMOVED & REPLACED THE BATTERY CHARGER IAW AMM 24-31-02, P/N OFF: 8-930-03, MESSAGE CLEARED, BUT RETURNED. REMOVED & REPLACED THE MAIN BATTERY IAW AMM 24-31-01. BATTERY CHARGER MESSAGE CLEARED. OPERATISDR UIEA2020082401856Selector · inoperativeFOUND CABIN PRESSURE SELECTOR INOP. REMOVED AND REPLACED CABIN PRESSURE SELECTOR IAW AMM 21-31-01, OPS CHECK GOOD IAW AMM 21-31-01, NO FURTHER DEFECTS NOTED AT THIS TIMESDR UIEA2020082401865Unknown · malfunctionedPRESSURIZATION WOULD BUMP ENROUTE APPROX EVERY 15-20 MINUTES WITH A NOTICEABLE DIFFERENCE IN FLOW FROM FLIGHT DECK GASPERS AND A CHANGE IN SOUND. OPS CHECK CABIN PRESSURE CONTROL SYSTEM IAW AMM 21-31-00, NO FAULTS NOTED AT THIS TIME.SDR UIEA2020082191818Tube · leakingEICAS MSG FOR L ENG BLEED OFF DURING DESCENT. FOUND SENSE LINE GOING TO PRC. REMOVED AND REPLACED TUBE ASSY. RAN ENG, OPS CHECKED AND TESTED OK. LEFT ENG BLEED ALL CHECK OK PER AMM 20-11-00 AND 71-00-00.)SDR UIEA2020081741768Controller · malfunctionedL ENG BLEED OFF ILLUMINATED AFTER PUSH BACK. REMOVED AND REPLACED #1 ENGINE PRVC IAW AMM 36-11-19 AND RESET ALL CB'S IAW AMM 36-11-19. LEAK CK, OPS CK GOOD. MAINT ACTIONS REVERSED. RAN ENGINES IAW AMM 71-00-00. BLEED SYSTEM OPERATES GREAT.SDR UIEA202008120737Quick Disconnect · leakingDURING PRE-FLIGHT INSPECTION, FOUND OIL POOLING UNDER NR 2 ENGINE. SECURED THE NR 2 ENGINE QUICK DISCONNECT T/R FITTING IAW MM 71-11-04. OPS CHECK OK.SDR UIEA2020072311587Transmitter · failedNR 2 ENGINE, NO FUEL FLOW INDICATION. PERFORMED FIM 73-31 TREE 806 ITEM 44, ACCOMPLISHED. REMOVED AND REPLACED THE FUEL FLOW TRANSMITTER FOR THE RT ENG, OPS CHECKED GOOD, FUEL FLOW TRANSMITTER TESTED GOOD.SDR UIEA2020072101589Actuator · inoperativeUPON STARTING RIGHT ENGINE, ENGINE APPEARED TO START NORMALLY BUT FUEL FLOW STAYED AT ZERO. REMOVED AND REPLACED THE RT ENGINE DUAL SHUTOFF VALVE ACTUATOR IAW AMM 28-22-11, OPS CHECKED GOOD.SDR UIEA2020072001586Fuel Sys · unknownRT ENGINE STARTED ON SECOND ATTEMPT, ENGINE RAN NORMALLY FOR 3 MINUTES. THEN FUEL FLOW WENT TO ZERO AND ENGINE SHUTDOWN. RETURNED TO BLOCKS. PERFORMED AN OPS CHECK IAW 28-22-11. RAN ENGINE THREE TIMES WITH NO FAULTS IAW AMM 70-00-00. CYCLED SPAR VALVE CIRCUITSDR UIEA2020071501528Ecu · malfunctionedRT ENG CONTROL EICAS MESSAGE ON TAXI. REMOVED AND REPLACED EEC UNIT RT IAW AMM 73-21-15, OPS TEST OK. PERFORMED SATISFACTORY ENG RUN PER MM 71-00-00. REMOVED AND / REPLACED VAR BLEED VALVE ACTUATOR, IAW AMM 75-32-01, OPS AND LEAK CHECK OK(P/N: / 1211318-006,SDR UIEA2020062601401Fuel Filter · faultyLT ENG FUEL FILTER EICAS MSG DURING CLIMB. REMOVED AND REPLACED LT ENG FUEL FILTER IAW AMM 73-11-02, LEAK CHECK GOOD. OPS CHECK GOOD FIM 73-11 FT 803.SDR UIEA2020100851400Bleed Valve · malfunctionedLEFT ENGINE FOUND FUEL LEAK DRAIN MAST FROM PORT "FUEL DIRECT", 8 DROPS PER MINUTE FOUND IN LIMITS, IAW AMM TASK 71-71-00-796-067-H00 TABLE 601. FUEL DRIP FROM DIRECT FUEL ON DRAIN MUST WITHIN LIMITS, PER AMM 71-71-00 TABLE 601. TRANSFER TO NON-MEL NR 130228SDR UIEA2020062301341Valve · unknownTEMP CONTROL VALVE CONTINUOUSLY FLUCTUATING IN AUTO CONTROL MODE. PERFORMED PRESSURE TEST ON TEMP CONTROL, SYSTEM NORMAL. NO FLUCTUATIONS NOTED IAW AMM 21-61-00.SDR UIEA2020052601130Radar · malfunctionedRADAR REQUIRES + 3 DEGREES IN ORDER TO NOT GET GROUND RETURNS. PERFORMED OPERATIONAL GROUND TEST OF WEATHER RADAR SYSTEM IAW B767 AMM 34-43-00. SYSTEM TEST NORMAL, NO FAULTS AT THIS TIME.SDR UIEA2020050400941Unknown · malfunctionedRADAR ON DESCENT INDICATED CONTINUOUS FAKE INDICATION OF MEDIUM TO HIGH PRECIPITATION FROM 0 TRIM EVEN IN CLEAR SKIES EITHER WX OR WXT ALL SCALES.(<P>PERFORMED OPS CHECK ON WXR IAW B767 AMM 34-43-00 AND SYSTEM OPERATES AND INDICATES CORRECTLY. FOUND GAIN SETTISDR UIEA2020042400829Spring · brokenPILOT WRITE UP EMERGENCY ARMING LIGHT SWITCH COVER SPRING BROKEN.(<P>REMOVED & REPLACED EMERGENCY LIGHT PANEL ASSY IAW B767 33-51-08 AMM, OPS CHECK GOOD.</P>)SDR UIEA2020040600703Module · faultyAPU BLEED AIR INOP ( AUXILIARY POWER UNIT, PNEUMATIC FUNCTION )(<P>TRANSFERRED TO MDDR 126636 IAW MEL 49-11-01-01, CAT 'C'.</P><P>12APR, LP 1149777, ITEM M3: TROUBLESHOOT APU PNEUMATIC PRESSURE IAW FIM 36-10 FAULT TREE 841 UP TO SHEET 2 BLOCK 35 & FIM 49-11 FASDR UIEA2020040600687Unknown · malfunctionedLEFT WEATHER RADAR SYSTEM ONLY PAINTS +/- LEFT AND RIGHT IN THE 320 RANGE.(<P>PERFORMED OPS CHECK OF LEFT WEATHER RADAR SYSTEM IAW AMM 34-43-00. OPS CHECK OK.</P>)SDR UIEA2020040200678Modulating Valve · faultyWHEN ATTEMPTING TO START ENG, THERE WAS NOT ENOUGH PSI FROM APU. PSI WAS AT 15 AND EVEN IF YOU TURNED ON PACK PSI WOULD DROP TO 8 PSI OR LESS.(<P>APU WAS TRANSFERRED TO MDDR 126566 IAW MEL 49-11-01A, CAT C, DUE DATE 12APR20, DISPATCH ACL 0532Z.</P><P>LOG PAGE SDR UIEA2020032500548Unknown · malfunctionedWX RADAR TILT REQ +2 ON THE TILT REQ TO NOT TOTALLY PAINT GROUND AT FL 370. NORMALLY AROUND 0 TO -1 IS REQ.(<P>PERFORMED WXR BITE PROCEDURE IAW FIM TASK 34-43. BITE TEST SHOWS SYSTEMS ARE OKAY. OPS CHECKED WXR RADAR SYSTEM IAW AMM 34-43-00. OPS CHECK GOOD. NOSDR UIEA2020031300438Oxygen Mask · defectiveFO O2 MASK VALVE SHUTTERS WHEN BREATHING IN.(<P>REMOVED AND REPLACED FO'S OXYGEN MASK IAW AMM 35-11-51. OPS CHECK GOOD AT THIS TIME. NO DEFECTS NOTED.</P>)SDR UIEA2020031300439Wire · damagedF/O O2 MASK WILL NOT TEST.(<P>FOUND WIRE GOING INTO FO'S MASK TO BE DAMAGED. RESPLICED WIRE IAW SWPM 20-10-13. OPS CHECKED FO'S MASK IAW 35-11-51. OPS CHECKED GOOD AT THIS TIME.</P>)SDR UIEA2020031000426Fitting · leakingLEFT ENGINE FUEL LEAK FROM DRAIN MAST FUEL PUMP, 03 DROPS PER MINUTE. LEAK WITHIN LIMITS IAW AMM 71-71-00. WITHIN LIMITS IAW AMM 71-71-00/601. LEAK TEST BAD IAW AMM 71-00-01. FOUND LINE & FITTING LEAKING AT THE FUEL IN LOCATION. FOUND FITTING & LINE LEASDR UIEA2020030500381Hose · looseAFTER START EICAS MSG LH ENG BLEED OFF, FOLLOWED QRH PROCEDURE AND COMPLETED ON GROUND (DUCT PRESS IND. ZERO) - REPEAT WRITE UP.(<P>AFTER FURTHER INVESTIGATION FOUND SUPPLY PRESSURE HOSE LOOSE ON PRV VALVE. TIGHTENED LINE AND PERFORMED ENG RUN. PNEUMATICS OPESDR UIEA2020030400379Circuit Card · defectiveAT 12000' LEFT ENG BLEED OFF EICAS. QRH PROCEDURE PERFORMED.(<P>TROUBLESHOT IAW FIM 36-10 FAULT TREE 836. REMOVED AND REPLACED BLEED AIR CONTROL CARD IAW AMM 36-11-12. OPS CHECK GOOD.</P>)SDR UIEA2020030200361Control Panel · faultyRT ISLN SWITCH POPS ON WITHOUT TOUCHING IT.(<P>REMOVED AND REPLACED BLEED AIR SUPPLY CONTROL PANEL IAW B767 AMM 36-11-26. OPS CHECK GOOD.<BR /></P>)
Back to N1381A