N1409A
Service difficulty reports · 458
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019123096165Status Message · false activationWEATHER RADAR SYSTEM STATUS MESSAGE. TROUBLESHOT IAW FIM 34-43 FT 805. NO FAULTS FOUND. SYSTEM OK.SDR UIEA2019122436134Radar · malfunctionedWX RADAR TILT (AUTO) TILT/DISH TO -1C AND PAINTS EXCESSIVE GROUND CLUTTER @ 37000.(<P>PERFORMED SYSTEM TEST AND OPERATIONAL TEST OF WEATHER RADAR SYSTEM, TESTED GOOD IAW B767 AMM 34-43-00-735-053-002 & 34-43-00-715-026-002. NO FURTHER DEFECTS NOTED AT THIS TIMSDR UIEA2019122306133Warning Message · false activationIDLE DISAGREE EICAS MESSAGE WHILE LANDING. ACCOMPLISHED FIM 32-09-03 FIG 103. NO PSEU FAULTS AT THIS TIME. CLEARED MSG, NO FURTHER FAULTS.SDR UIEA2019122096114Pump · inoperativeL AFT FUEL PUMP INOP.(<P>TRANSFERRED TO MDDR 122287 IAW MEL 28-22-01, CAT 'C'.</P><P>LP 1232308: TROUBLESHOT PER FIM B767 28-22 FAULT TREE 819. ALL SYSTEMS NORMAL. CLEANED & RESET CONNECTOR ON L AFT BOOST PUMP. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2019121326061Start Valve · malfunctionedADVISORY: DURING LEFT ENG START, L ENG STARTER EICAS MSG APPEARED FOR 3 SECONDS, THEN DISAPPEARED. ENG THEN STARTED NORMALLY.(<P>T/S PER FIM 80-11 FT 803, PERFORMED BITE TEST ON L PIMU. FLAGGED "L SAV DISAGREE". REMOVED AND REPLACED START VALVE IAW AMM 80-11-0SDR UIEA2019121326059Warning Message · false activationADVISORY: DURING LEFT ENGINE START, "L ENG STARTER" ILLUMINATED. PRIOR TO CREW BEGINNING CHECKLIST, EICAS MSG DISAPPEARED AND ENGINE STARTED NORMALLY.(<P>PREFORMED OPERATIONAL START OF L/H ENGINE IAW B767 AMM 80-11-00, NO DEFECTS NOTED. NO ENGINE STARTER MSG.<SDR UIEA2019120325981Pressure Switch · failedLEFT FWD AND AFT FUEL PUMPS NOT DEPRESSURIZED. NO PRESS LIGHTS.(<P>TRANSFERRED TO MDDR 121445 AS PER MEL DDG 28-22-01-01. L AFT PUMP DE-ACTIVATED, C/B PULLED AND COLLARED, CAT 'C', DUE DATE 13-DEC-19. PLACARD INSTALLED.</P><P>LP 1232253 - M5: REMOVED AND REPLASDR UIEA2019120325979Oil System · lowAPU OIL QUANTITY STATUS MESSAGE, APU DID NOT START. ONLY ONE ATTEMPT MADE.(<P>SERVICED APU OIL IAW AMM 12-13-04. RAN APU IAW AMM 49-11-00, OPS CHECK OK AT THIS TIME.</P>)SDR UIEA2019112005935Regulator · leakingCREW O2 BOTTLE 1 LEAKING AT COUPLING.(<P>REMOVED AND REPLACED CREW O2 BOTTLE 1 REGULATOR ASSY- TRANSDUCER IAW B767 AMM 35-11-04, NO LEAKS NOTED.<BR /></P>)SDR UIEA2019102425778Pressure Switch · malfunctionedAFT LEFT FUEL PUMP LOW PRESSURE LIGHT NOT ILLUMINATED WITH PUMPS SWITCH OFF. REPEAT WRITE-UP REF LOG PAGE 1086652 AND 1086631.(<P>TRANSFERRED TO MEL 28-22-01. MDDR 119492 ASSIGNED, CAT 'C', DUE DATE: 01-NOV-19. MAINT PROCEDURES C/W.</P><P><BR DATA-MCE-BOGUS="1SDR UIEA2019102105762Warning Light · no indicationAFTER SHUTTING DOWN BOTH ENGINES, WITH APU RUNNING AND TURNING ALL FUEL PUMPS OFF, THE LEFT AFT FUEL PUMP LOW PRESSURE LIGHT NOT ILLUMINATED.(<P>PERFORMED OPERATIONAL TEST OF THE LEFT AFT FUEL PUMP PER AMM 28-22-03, OPS CHECK NORMAL.</P>)SDR UIEA2019101605732Knob · unsecureAPU SELECTOR KNOB IS LOOSE. RE-SECURED APU SELECTOR KNOB REF AMM 49-41-81, OPS CHECK NORMAL AT THIS TIME. </P>)SDR UIEA2019101505720Seal · dislodgedORANGE SEAL APPEARS EXTRUDED OR DISLODGED ON SENSOR PROBES IN ENGINE INLET ON # 2 ENGINE.(<P>CORRECTED SEAL IAW AMM 72-32-00, NO FURTHER DEFECTS NOTED AT THIS TIME. </P>)SDR UIEA2019101305710Selector · looseAPU START SELECTOR IS LOOSE. ADJUSTED & TIGHTENED APU START SELECTOR IAW AMM 49-61-00. OP'S CHECK NORMAL AT THIS TIME.SDR UIEA2019100315619Engine · not reportedNR 2 ENG DISC RECORD COMPLIANCE ISSUE. REMOVED AND REPLACED THE NR 2 ENGINE IAW AMM 71-00-02.SDR UIEA2019092105553Unknown · malfunctionedLEFT AFT FUEL PUMP WILL NOT TURNOFF WHEN DE-SELECTED, NO PRESSURE LIGHT OR ASSOCIATED EICAS MESSAGE. PERFORMED OPS TEST LEFT AFT FUEL PUMP IAW AMM 28-22-00-1. OPS CHECKED GOOD, PRESSURE LIGHT AND EICAS MESSAGE WHEN PUMP OFF.SDR UIEA2019091205489Unknown · malfunctionedITEM 1 - APU COLD SOAK START FL 360 -51 TEMP, 21:52Z; 3 ATTEMPTS UNSUCCESSFUL. ITEM 2 - APU FAULT EICAS. NOTED BY MX, DMI CONTINUES FOR APU COLD SOAK, MCC ADVISED. ITEM - 2: PERFORMED APU BITE PROCEDURE IAW FIM 49-11 FT 987. ECU LRU FAULTED, CLEARED FAULT, APUSDR UIEA2019082505279Pressure Switch · malfunctionedCTR LEFT FUEL PUMP INOP. PERFORMED FIM TASK 28-22 FT 805 UP TO AND INCLUDING SHEET 3 BLOCK 49/50. SYSTEM (PUMP) WORKED AS REQUIRED, PER FIM RECOMMEND PRESSURE SWITCH PN # 60B92400-7 (LOC:S423) REF WDM 28-22-12. REMOVED AND REPLACED CENTER (OVERRIDE) LT FUELSDR UIEA2019081965206Warning Message · false activationLEFT ENG SPEED CARD STATUS MESSAGE DISPLAYED AT BLOCK-IN. TROUBLESHOT PER B767 FIM 73-21 FT 871, NO FAULTS NOTED AT THIS TIME.SDR UIEA2019081205009Relay · unknownLEFT CENTER PUMP LOW PRESSURE LIGHT ILLUMINATED. TROUBLESHOT THE LEFT CENTER BOOST PUMP IAW FIM 28-22 FT 805, NO FAULTS NOTED. THE LEFT CENTER LIGHT STARTS FLASHING AROUND 1500 POUNDS, THIS IS NORMAL. RT CTR WILL PUMP TO .4 POUNDS. REOPENED ORIGINAL MDDR SDR UIEA2019080404943Warning Message · false activationLEFT CENTER FUEL PUMP INOP ON TAXI OUT.(<P>TRANSFERRED TO MDDR 115786 IAW DDG 28-22-02A, CAT C. TROUBLESHOT L CTR FUEL PUMP IAW FIM 28-22 FAULT TREE 805. NO DEFECTS NOTED, OPS CHECK GOOD.SDR UIEA2019070804712Warning System · false activationRT GEN DRIVE REMAINED ON FOR 2 MINUTES AFTER START TNEN EXTINGUISHED(<P>PERFORMED IDG INSPECTION IAW AMM 24-11-01 NO DEFECTS NOTED</P>)SDR UIEA2019070604689Control Panel · malfunctionedL WXR SYS AUTO TILT MODE INOP (<P>TRANSFERRED TO MDDR # 114328 AS PER MEL 34-43-01-04 CAT C </P><P>LP 1090216-M3 REPLACED WXR CONTROL PANEL PERFORMED GROUND TEST SYSTEM OK IAW AMM 34-43-02 AND 34-43-00</P>)SDR UIEA2019070704690Indication Sys · malfunctionedLEFT FUEL FLOW INDICATION INOP (<P>TRANSFER TO MDDR # 114307 IAW DDG 73-31-01-02 CAT C DUE DATE 16JULY-2019</P><P>LP 1090219-M5 INBOUND CREW REPORTED LEFT FUEL FLOW INIDICATION NORMAL RAN LEFT ENG AND OPS CHECK OK IAW AMM 71-00-00 </P>)SDR UIEA2019070704691Pump · malfunctionedCENTER LEFT BOOS PUMP INOP (<P>TRANSFER TO MDDR # 114305 IAW DDG 28-22-02A CATC DUE DATE 16-JULY-2019</P><P>LP 1090219 -M4 RESET /B LEFT CENTER BOOST PUMP OPS CHECK OK IAW AMM 28-22-05 </P>)SDR UIEA2019070504684Control Valve · malfunctionedLEFT PACK TEMP EICAS MSG AND AUTO SHUT DOWN(<P>REMOVED AND REPLACED LEFT PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-12 OPS CHECK GOOD </P>)SDR UIEA2019070404671Idg · lowRIGHT GENERATOR DRIVE EICAS MESSAGE INTERMITTENT. (<P>SERVICED ENG # 2 IDG REF 12-13-03 AND PERFORMED ENGINE RUN REF AMM 71-00-00. IDG COMES ONLINE AS REQUIRED, PUT A LOAD, NO DEFECTS NOTED AT THIS TIME. A/C OK FOR SERVICE. </P>)SDR UIEA2019070404673Control Valve · malfunctionedRIGHT PACK TEMP EICAS MESSAGE. (<P>C/W BITE CHECK ON TEMP CONTROL BOX IAW AMM 21-51-00. FOUND FAULT ON TEMP CONTROL VALVE, REPLACED RIGHT TEMP CONTROL VALVE AND OPS CHECKED IAW AMM 21-51-12-004-001/404-013. OPS CHECK GOOD, NO FAULTS NOTED. </P>)SDR UIEA2019070204654Warning System · false activationRT PACK TEMP EICAS MSG.(<P>PERFORMED BITE TEST CHECK ON TEMP CONTROLLER COMPT IAW FIM 21-51-803. NO FAULTS NOTED AT THIS TIME ON RIGHT HAND PACK.</P>)SDR UIEA2019070204655Control Unit · malfunctionedLEFT PACK TEMP EICAS MSG.(<P>PERFORMED BITE TEST ON LEFT PACK TEMP CONTROL UNIT IAW FIM 21-51-803. NO FAULTS NOTED AT THIS TIME, OPS TEST OK.</P>)SDR UIEA2019063004619Warning System · false activationR PACK TEMP EICAS MESSAGE ON GROUND. EICAS MESSAGE WENT AWAY AFTER A FEW MOMENTS. (<P>PERFORMED RT PACK OPS TEST AND BITE TEST OF RT PACK TEMP CONTROLLER IAW AMM 21-51-00. NO FAULTS NOTED AT THIS TIME.</P>)SDR UIEA2019062804613Lanyard · unsecureMAIN ENTRY DOOR ESCAPE ROPE FELL OUT WHEN OPENING ENTRY DOOR. MISSING SNAP ON STORAGE BAG. SECURED SNAPS ON ESCAPE ROPE COVER IAW SRM 51-40-02, OPS NORMAL.SDR UIEA2019062104549Pressure Switch · failedWITH FUEL IN CENTER TANK 1200LBS LEFT CENTER FUEL PUMP PRESSURE LIGHT ON WHEN OPERATING PUMP EICAS. REMOVED AND REPLACED LEFT CENTER PUMP PRESSURE SWITCH IAW AMM 28-42-01. PERFORMED TEST AND SYSTEM OK. RESET BREAKERS.SDR UIEA2019062104550Unknown · noiseBLEED AIR NOISE IN COCKPIT REACHES 78.3 DB AT CLIMB POWER. COULD NOT DUPLICATE ON GROUND. OPS CHECK OF PACK SYSTEM GOOD IAW AMM 21-51-00. T/S FLIGHT DECK BLEED AIR NOISE IAW AMM 21-22-00. NO DEFECTS NOTED. RAN RH ENGINE TO TRY TO DUPLICATE THE NOISE IAW AMM SDR UIEA2019062104548Bpcu · failedAFTER START OR THE NR 2 ENGINE, GEN DRIVE LIGHT ILLUMINATED SELF EXTINGUISHED AFTER 1 MINUTE. SERVICED THE IDG IAW AMM 12-13-03. OPS CHECKED GOOD. BPCU SHOWS NO FAULTS. REMOVED AND REPLACED BPCU IAW AMM 24-41-03. OPS CHECKED GOOD.SDR UIEA2019062004535Warning Message · false activation"RIGHT PACK TEMP" EICAS, RIGHT PACK OVERHEAT.(<P>PERFORMED PACK TEMPERATURE CONTROLLER BITE TEST REF AMM 21-51-14-705-035. COULD NOT DUPLICATE MESSAGE. OPS CHECK OK AT THIS TIME.</P>)SDR UIEA2019061434486Pump · warning messageLEFT CTR FUEL PUMP PRESS LIGHT ILLUMINATED AND L CTR FUEL PUMP EICAS MSG (AMBER). REMOVED AND REPLACED LEFT CENTER OVERRIDE PUMP IAW AMM 28-22-05. LEAK CHECK GOOD, TRANSFERS GOOD, PRESS LIGHT GOOD.SDR UIEA2019061324469Status Message · false activationSTATUS MESSAGE, LEFT ENGINE SPEED CARD. PERFORMED OPS CHECK IAW PER B767 AMM 77-12-00. OPS CHECKED GOOD, NO STATUS MESSAGE DISPLAYED.SDR UIEA2019061204468Pump · malfunctionedLEFT CENTER FUEL PUMP INOP. PERFORMED OPS CHECK OF PUMP PER AMM 28-22-01. OPS CHECK GOOD.SDR UIEA2019061104457Idg · malfunctionedEICAS MSG "RT GEN OFF". TROUBLESHOT RT GEN OFF MSG. REMOVED AND REPLACED BUS POWER CONTROL UNIT IAW B767 AMM 24-41-03. BPCU TEST GOOD. OVER VOLTAGE TRIP FAULT WAS RECORDED ON LAST FLT WAS REASON. NO FAULTS PRESENT AT THIS TIME. REMOVED AND REPLACED RIGHT ENGSDR UIEA2019061084440Gcu · malfunctionedTHRU 18,000 AFTER TURNING TAXI L&R TURNOFF LIGHTS & WING LANDING LIGHTS, ENTIRE 2 AC BUS FAILED. "R AC BUS ISLN" CAUTION MSG. RAN QRH & COMPLIED. A MAYDAY CALL WAS DECLARED. MULTIPLE SYSTEMS FAILURES OCCURRED DURING REST OF DESCENT. SDR UIEA2019061074429Connector · not seatedSTANDBY PACK TEMP CONTROLLER FAILS BITE TEST "RIGHT COMP SENSOR" RESEATED CONNECTORS TO TS5134 AND TS5135 OPS CHECK GOOD IAW AMM 21-51-14-705-036, 21-51-06, SSM 21-50-06, 21-50-05, WDM 21-51-23, 21-51-13.SDR UIEA2019061074430Unknown · damagedL/H SIDE WINDOW HEAT PB IS DAMAGED. REMOVED AND REPLACED L/H SIDE WINDOW HEAT PB IAW B767 AMM 30-41-02 AND SWPM 20-84-15. PERFORMED SAT OPS CHECK IAW AMM 30-41-02 AND 33-13-00. NO DEFECTS NOTED.SDR UIEA2019061074431Warning Message · missingEICAS IS MISSING INDICATION ON RT "PRIM HX IN". PERFORMED BITE TEST FOR MR SUPPLY BITE MODULE IAW B767 AMM 36-11-16-745-135 BITE PASSED INDICATION PRESENT.SDR UIEA2019061074432Valve · malfunctionedR/H ENG FAV CLOSED AND OPEN SWITCHES DISAGREE. REMOVED AND REPLACED THE R/H ENG FAV (SUPPLY PRE-COOLER VALVE) IAW B767 AMM 36-11-15. PERFORMED SATISFACTORY OPS CHECK IAW B767 AMM 36-11-15.</P>)SDR UIEA2019061074433Door · excess playNR 2 ENG OB CORE COWL PRESSURE RELIEF DOOR HAS PLAY. REMOVED AND REPLACED NR 2 ENG OB CORE COWL PRESSURE RELIEF DOOR HINGE PINS AND RELATED HARDWARE IAW B767 AMM 71-11-09.SDR UIEA2019061074434Connector · corrodedNR 1 ENG IGNITION BOXES HAVE CORROSION ON CANNON PLUG CONNECTION RECEPTACLES. REMOVED AND REPLACED BOTH IGNITION EXCITER BOXES AND PERFORMED SATISFACTORY OPS TESTS #1 ENG IAW AMM 74-11-01 AND AMM 74-00-00.SDR UIEA2019060704435Plug · gougedNR 2 OB BORESCOPE PLUG B3-1 GOUGED. REMOVED AND REPLACED #2 ENG BORESCOPE PLUG B3-1 IAW AMM 72-00-00. LEAK CHECK ACCOMPLISHED ON TC T2031.SDR UIEA2019061074437Wire · brokenRIGHT PACK CONTROLLER BITE FAILS MX MAN SENSOR. FOUND AND RETERMINATED BROKEN WIRES AT CONNECTOR D2826 IAW B767 WDM 21-51-22 PERFORMED SATISFACTORY OPS CHECK IAW B767 AMM 21-51-14. NO DEFECTS NOTED. FAULT CLEARED.SDR UIEA2019061004446Unknown · damagedLH SIDE WINDOW HEAT P/B IS DAMAGED. REMOVED AND REPLACED LH SIDE WINDOW HEAT P/B IAW AMM 30-41-02 AND SWPM 20-84-15. PERFORMED OPS CHECK IAW B767 AMM 30-41-02 AND 33-13-00 NO FAULTS NOTED.
Back to N1409A