N1409A
Service difficulty reports · 458
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1409A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019061004448Filter · trippedLEFT HYD BAY RETURN FILTER MODULE PRESSURE INDICATOR POPPED. REMOVED AND REPLACED LH HYD RETURN FILTER IN LH PYLON IAW B767 AMM 29-11-17. ACCOMPLISHED OPS CHECK IAW B767 AMM 29-11-00, 29-11-17 AND 71-00-00 NO DEFECTS NOTED. </P>)SDR UIEA2019061004451Pump · damaged#2 ENG EDP FOUND DAMAGED DEPRESS VALVE. REMOVED AND REPLACED NR 2 EDP DEPRESS VALVE IAW B767 AMM 29-11-05 ACCOMPLISHED OPS CHK. IAW AMM 29-11-00, 29-11-05 AND 71-00-00 NO DEFECTS NOTED.SDR UIEA2019061004455Sensor · faultedFLT DECK DUCT TEMP SENSOR FAULT ON ZONE TEMP CONTROLLER. REMOVED AND REPLACED FLT DECK DUCT TEMP SENSOR IAW AMM 21-61-02 PERFORMED GOOD OPS CHECK IAW B767 FSM 21-61FAULT TREE 912 NO DEFECTS NOTED.SDR UIEA2019061004456Shutoff Valve · malfunctionedRH ENG HYD PRESSURE FROM PUMP WAS INOP. REMOVED AND REPLACED EDP. REMOVED AND REPLACED HYD SHUTOFF VALVE.SDR UIEA2019050504129Unknown · malfunctionedNO LIGHT ON FIRST START ATTEMPT USING SINGLE IGNITION. USED BOTH FOR SECOND ATTEMPT, SUCCESSFUL START. RIGHT ENGINE(<P>PERFORMED IGNITION AUDIBLE TEST IAW AMM 74-00-00 NO FAULTS NOTED. OPS CHECK NORMAL AT THIS TIME.</P>)SDR UIEA2019050304105Unknown · malfunctionedNR 2 ENGINE NO EGT RISE ON FIRST START (<P>SEE ITEM 3 ON LOG PAGE 1078399. ACCOMPLISHED RIGHT ENGINE START OPS CHECK NORMAL IN BOTH, SINGLE AND DUAL IGNITION. OPERATION IAW AMM 74-00-00 AND 72-00-00</P>)SDR UIEA2019050304106Igniter · faultyRIGHT ENGINE IGNITER 2 STATUS MESSAGE (<P>REMOVED AND REPLACED THE RIGHT ENGINE NR 2 IGNITER PLUG. OPS CHECK GOOD ON AUDIO CHECK IAW AMM 74-21-00 AND 74-00-00-705-015. </P>)SDR UIEA2019050104088Warning System · false activationRIGHT ENG IGNITION 2 STATUS MSG ON RIGHT ENG START (<P><SPAN>PERFORMED RT ENG IGNITION SYS AUDIBLE TEST IAW AMM 74-00-00. OPS CHECK GOOD. PERFORMED PIMU (RT) BITE PROCEDURE IAW FIM 71-01 FAULT TREE 810 AND PERFORMED 2 ENGINE RUNS OF RT ENGINE IAW AMM 71-00-0. SDR UIEA2019042603963Oxygen Mask · damagedCAPT O2 MASK RATTLES WHEN BREATHING IN.(<P>SWAPPED CAPTS O2 MASK P/N MC10-08-109 SN SE72273 WITH THE RIGHT SUPERNUMERARY SEAT PN MC 10-08-109 SN B124047. IAW AMM 35-11-51. OPS CHECK NORMAL. REF ITEM 3 THIS PAGE FOR RIGHT SUPERNUMERARY SEAT DEFERRAL.</P>)SDR UIEA2019042603972Oxygen Mask · inoperativeRIGHT SUPERNUMERARY SEAT OXYGEN MASK INOP.(<P>TRANSFERRED TO DMI 110647.</P><P>LOG PAGE 1078435: REF DMI 110647, REMOVED AND REPLACED RH SUPERNUMERARY O2 MASK IAW AMM 35-11-51. OPS CHECKS GOOD. THIS CLEARS DMI 110647. MCC NOTIFIED AND PLACARDS REMOVED.</P>)SDR UIEA2019041703899Engine · malfunctionedR ENGINE NO LIGHT OFF WITH SINGLE IGNITER, SWITCHED TO BOTH IGNITERS.(<P>PERFORMED ENGINE START / RUN W. SINGLE IGNITER SELECTED. ENGINE START UP NORMAL THROUGH ALL PARAMETERS. ALSO PERFORMED IGNITER CHECK PRIOR TO START. NO FAULTS NOTED IAW AMM 74-00-00 & 80-SDR UIEA2019041973898Monopole · looseAPU INOP. PERFORMED APU CONTROL UNIT BITE TEST IAW AMM 49-61-05. FOUND SPEED SENSOR #1 & 2 FAULTED ON ECU PREVIOUS 3RD & 4TH STARTS. PER MCC PERFORMED OPS CHECK OF APU . OPS NORMAL. NO DEFECTS NOTED. COMPLIED WITH WDM 49-16-11, & CONTINUITY GOOD BOTH MONOPOSDR UIEA2019041603885Pump · inoperativeLH FWD FUEL BOOST PUMP INOP (<P>TRANSFERRED TO MDDR 110289.</P><P>LP 1061087 - PERFORMED TS IAW FIM 28-25 FT 807 AND RESET GFI RELAY K10701. PERFORMED OPS CHECK IAW AMM 28-22-03. ALL CHECKS NORMAL. THIS CLEARS MDDR 110289. PLACARD REMOVED AND MCC ADVISED. MCC SDR UIEA2019041503871Apu · malfunctionedAPU FAULT ON 1ST ATTEMPT AFTER LANDING. SUCCESSFUL START ON 2ND ATTEMPT. PERFORMED BITE TEST PER AMM 49-81-02. OPS CHECK GOOD PER AMM 49-11-00. NO DEFECTS NOTED AT THIS TIMESDR UIEA201904043765Warning Message · false activationLEFT ENGINE ANTI ICE(<P>PERFORMED FIM 30-21 F.T. 806 ON LEFT ENG ANTI ICE. NO DEFECT NOTED AT THIS TIME. OPS CHECK NORMAL AT THIS TIME. CONTINUITY CHECKS CHECKED GOOD.</P>)SDR UIEA2019040103738Oil System · lowAPU FAULT ON TAXI IN(<P>PERFORMED TEST OF APU ECU ONLY FAULT NOTED WAS LOW OIL IAS AMM 49-61-01 SERVICED OIL IAS AMM 12-13-04 NO FURTHER FAULT NOTED OK AT THIS TIME</P>)SDR UIEA2019032203602Connector · dirtyLEFT ENGINE FUEL FLOW 300 - 400 PPH HIGHER THAN RIGHT, WITH NO FUEL IMBALANCE. (<P>PER FIM 73-31 FT 806, NO LEAKS NOTED. CLEANED CONNECTOR AT FF TRANSMITTER AND RAN ENGINE MIN IDLE, HAD 200 LBS SPLIT. OK TO CONTINUE SERVICE. </P>)SDR UIEA2019031103516Warning System · false activationDURING ENG START MOMENTARY OVERSPEED WARNING MSG(<DIV>PERFORMED FIM TASK 71-01-00 PIMU BITE CHECK NO FAULT FOUND AT THIS TIME. STARTED ENGINE MULTIPLE TIMES IAW 71-00-00, ALL ENGINE STARTS NORMAL AT THIS TIME. </DIV>)SDR UIEA2019030803501Guard · defectiveGUARD FOR EMERGENCY LIGHT SWITCH OVERHEAD P5 PANEL INOP (<P>TRANSFERRED TO MDDR 108362 AS PER DDG 25-20-01 NEF FLIGHT DECK (NEW NEF). </P><P>LP 1051442-M3: REMOVED AND REPLACED EMERGENCY LIGHTS GUARD SWITCH ASSEMBLY IAW
AMM 33-51-08. THIS CLEARS MDDR 10836SDR UIEA2019030703495Warning System · false activationINFO ONLY: "APU FAULT" EICAS MESSAGE. APU STARTED CORRECTLY ON THE SECOND ATTEMPT. (<P>PERFORMED OPS TEST OF APU, OPS CHECK OK IAW AMM 49-11-00.</P>)SDR UIEA2019022503381Warning Message · false activationAPU OIL LEVEL LOW. PERFORMED VISUAL INSPECTION OF APU OIL LEVEL . FOUND TO BE WITHIN OIL LEVEL SPECS IAW AMM 49-27-00, NO FURTHER DEFECTS NOTED.SDR UIEA2019021803246Test Switch · damagedFIRST OBSERVER OXYGEN MASK STOWAGE BOX TEST SW DAMAGED.(<P>TRANSFER TO MDDR # 107395 IAW DDG 25-11-02-01A </P><P>LP 706777: R&R O2 BOX, LEAK CHECK OK. THIS CLEARS DMI 107395. </P><P><BR DATA-TEMP="1" /></P>)SDR UIEA201902143177Lamp · inoperativeL FWD FUEL PUMP PRESSURE LIGHT INOP(<P>TRANSFER TO MDDR #107152 IAW DDG 28-42-01-01 CAT C DUE DATE 20-FEB-19 PLACARD INSTALLED. </P><P>LEFT FWD FUEL PUMP PRESS LIGHT RELAMPED IAW AMM 33-13-00 AS PER MX CONTROL. OPS CHECK GOOD. THIS ACTION CLEARS DMI #107152, SDR UIEA2019013003057Indicator · defectiveE&E COOLING LOW FLOW MONITOR IRU-C, IRU-L, AND E5, FLOW BALLS STUCK IN UP POSITION. REMOVED AND REPLACED E&E COOLING MONITOR INDICATOR. OPS TESTED OK PER AMM 21-58-00-715-244-008.SDR UIEA2019013003058Indicator · inoperativeFUELING STA LT FUEL SELECT INDICATOR, INDICATOR BACK LIGHT INOP. R&R FUELING STA LT FUEL SELECT/QTY INDICATOR. OPS CHECK OK PER AMM 28-41-06.SDR UIEA2019013003059Indicator · inoperativeFUELING STA FUEL SELECT INDICATOR BACK LIGHT INOP. R&R FUELING & RIGHT & FUEL TANK LOAD SELECT INDICATOR IAW AMM 28-41-06. INDICATION TESTS GOOD.SDR UIEA2019012403022Unknown · malfunctionedAFTER LANDING, APU FAILED TO START FIRST ATTEMPT APU RPM 30% HANGING, THEN APU FAULT EICAS MSG , SUCCESSFUL START ON SECOND ATTEMPT (<P>PERFORMED BITE OF PAU ECU NO FAULTS NOTED , APU STARTED NORMALLY BITE IAW AMM 49-61-05</P>)SDR UIEA2019010900047Indicator · defectiveOUTFLOW VALVE POSITION INDICATOR VARIES ERRACTICALLY . INDICATES FULLY CLOSED IN CRUISE(<DIV>RR CABIN PRESSURE INDICATOR IAW AMM 21-33-01. OPS CHECK IS NORMAL AT THIS TIME. NO DEFECTS NOTED PN 130502-7 SN OFF 105-70416 SN ON 113-372 </DIV>)SDR UIEA2019010700039Connector · disconnectedFIRST OFFICERS OXYGEN MASK MICROPHONE DOES NOT TEST SUCCESSFULLY.(<P>FOUND MASK MIC FO SIDE CONNECTOR DISCONNECTED - RE-SECURED AS REQUIRED - OPS TEST GOOD IAW 35-11-51.<BR /></P>)SDR UIEA2018123102975Control Valve · malfunctionedRT PACK TEMP EICAS MSG RAN QRH PROCEDURE WHICH PLACED PACK CONTROL SELECTOR TO STBY R PACK TEMP LIGHT EXTINGUISHED , CHECK LIST COMPLTED (<P>REMOVED AND REPLACED RT TEMP CONTROL VALVE IAW AMM REF 21-51-12 OPS CKS GOOD ON GROUND </P>)SDR UIEA2019010300012Warning System · false activationRT PACK TEMP EICAS MESSAGE. PERFORMED BITE CHECK OF THE RIGHT PACK TEMP CONTROL IAW FIM 21-51 FAULT TREE 844. BITE TEST NORMAL, OPS CHECK OF RIGHT PACK GOOD AT THIS TIME PER AMM 21-51-00.SDR UIEA2018123102966Unknown · fault messageAPU FAULT ON START UP AFTER LANDING STARTED SECOND ATTEMPT(<P>PERFORMED APU & & ECU BITE TEST IAW FIM 49-11 FT 987 & AMM 49-11-00 / 501 NO FAULT NOTED AT THIS TIME PERFORMED 03 NORMAL APU START TO TEST; OPS CHECK NORMAL.</P>)SDR UIEA2018123102970Heater · malfunctionedEICAS PROBE HEAT AFTER ENGINE START(<P><SPAN>FOUND / PITOT HEAT C/B POPPED. RESET BREAKERS. SYSTEM OPS OK. (AMM 30-31-00)</SPAN></P>)SDR UIEA2018122802949Connector · dirtyRIGHT PACK TEMP EICAS CAUTION MSG, RAN QRH, MSG DISAPPEARED. (<P>FOUND TCV FAULT ON RT PACK CONTROLLER BITE , CLEANED AND RE-SECURED CANNON PLUG ON TCV, RIGHT PACK OPS TEST GOOD I.A.W AMM 21-51-00 FAULT CLEARED AND NO EICAS MSG DISPLAYED </P>)SDR UIEA2018122632908Hose · defectiveLEFT PACK INOPERATIVE. REMOVED AND REPLACED DEFECTIVE HOSE FOUND IN L/H PACK BAY IAW B767 AMM 20-11-00 THIS CLEARS DMI 104991 </P>)SDR UIEA2018121902885Engine · vibrationENGINE CHANGE REQUIRED DUE TO HIGH VIBRATION (<P>REMOVED AND REPLACED LH ENGINE I.A.W AMM 71-00-00 OPS CHECK NORMAL, NO LEAKS NOTED </P>)SDR UIEA2018121802873Engine · vibrationDURING CLIMB OUT RT ENGINE VIB 3.6 IN CRUISE 2.1 2.3. PERFORMED TRIM BALANCES PROCEDURRES IAW AMM 72-31-00 WITHIN SERVICEABLE LIMITS.SDR UIEA2018121702857Unknown · vibrationDURING TO AND CLIMB THE RIGHT ENG FAN VIB WAS AT 4.1-4.4 WITH A NOTICABLE AIRFRAME VIBRATION. DURING CRUISE VIB WENT DOWN TO 1.6. PERFORMED VISUAL INSPECTION OF RT ENGINE FAN BLADE, SPINNER AND TURBINE BLADES IAW FIM 71-05 FT 853. FIM C/W NO DEFECTS.SDR UIEA2018121502840Unknown · vibrationDURING CLIMB OUT THE LEFT FAN ENGINE VIBE WENT UP TO 4.3 ON THE SCALE ON THE LOWER EICAS, ONCE LEVEL AT 16000 WITH CRUISE THRUST THE FAN VIBE WAS 1.1. PERFORMED VISUAL INSPECTION OF THE LT ENG FAN BLADE, SPINNER AND TURBINE BLADES IAW FIM 71-05 FT 853, NO DEFESDR UIEA2018121402835Warning System · false activationAPU FAULT CAUTION MSG. PERFORMED BITE CHECK OF APU ECU IAW AMM 49-61-05, NO FAULTS FOUND. PERFORMED OPS CHECK OF APU 4 TIMES IAW AMM 49-11-00. OPS CHECK GOOD.SDR UIEA2018112982736Anti-Ice Valve · failedRIGHT ENGINE ANTI ICE VALVE STATUS MESSAGE ON ARRIVAL(<P>REMOVED AND REPLACED RH ENGINE ANTI-ICE VALVE I.A.W AMM 30-21-03 OPS CHECK GOOD </P>)SDR UIEA2018112972725Anti-Ice Valve · malfunctionedRIGHT ENGINE TAI VALVE STATUS MSG AFTER LANDING(<P>REMOVED AND REPLACED TAI IAW AMM 30-21-03 ALSO R&R #2 ENGINE PRESSURE SWITCH IAW 30-21-01 OPS CHECK GOOD </P>)SDR UIEA2018112702710Warning Message · false activationRIGHT ENGINE ANTI ICE VALVE STATUS MESSAGE ON ARRIVAL (<P>RIGHT ENGINE ANTI ICE VALVE STATUS MESSAGE ERASED IAW FIM 30-21 FT 805. PERFORMED ENGINE RUN OF RIGHT ENGINE IAW FIM 30-21 FT 805 BLOCK 2 WITH NO FAULT FOUND. SYSTEM OPS CHECK OK </P>)SDR UIEA2018112972722Warning Message · false activationRIGHT ENGINE TAI VALVE STATUS MSG (<P>RIGHT ENGINE TAI VALVE EICAS MESSAGE ERASED PER FIM 30-21 FT 805 RAN ENG OPERATED RIGHT ENG TAI PRESS MAINTAINED 38 PSI WITH TAI ON OPS CKS OK PER FIM 30-21-FT 805 </P>)SDR UIEA201811212657Anti-Ice Valve · failedAFTER SHUTDOWN RIGHT ENGINE ANTI ICE VALVE LIGHT ILLUMINATED ON OVERHEAD PANEL(<DIV>REMOVED AND REPLACED VALVE COWL ANTI ICE IAW AMM 30-21-00 OPS CHECK GOOD </DIV>)SDR UIEA2018123002961Sensor · malfunctionedAPU DID NOT START ON FIRST ATTEMPT (<P>PERFORMED BITE TEST OF APU AT ECU PREVIOUS START STOPPED ABORTED START FOR SPED SENSOR / # 2 SPEED SENSOR MEMORY CLEARED ECU BITE TEST NORMAL IAW FIM 49-11 FT 987 NORMAL 2 OPERATIONAL TEST NORMAL IAW 49-11-00/501 </P>)SDR UIEA2018110502519Warning Message · false activationLEFT ENGINE VALVE LIGHT AND LEFT VALVE EICAS MESSAGE ILLUMINATED. CYCLED THE CIRCUIT BREAKER IAW AMM 26-60-01. NO DEFECT NOTED. OPS CHECKED GOOD.SDR UIEA2018102202313Clamp · missingENGINE VIBE ON LEFT FAN EXCEEDED 4.0 DURING CLIMB. ACCOMPLISHED FIM 71-05 FT 852 - CREW REPORTED ENGINE VIBE WAS NORMAL AT CRUISE. FIM TASK NOTED B - LEVEL SHOULD BE CONSIDERED AT STABLE CONDITION. FOUND WIRE BUNDLE NR 1 ENG FAN ACCELEROMETER LOOSE AND MISSINGSDR UIEA2018101902286Filter · cloggedFLT DECK AUTO TEMP CONTROLLER ERRATIC AND UNABLE TO MAINTAIN TEMPERATURE. FOUND FLIGHT COMPARTMENT ZONE TEMP SENSOR FILTER CLOGGED. CLEANED FILTER AND OPS CHECK GOOD IAW AMM 21-61-08-004-003.SDR UIEA2018101802283Chip Detector · missingAPU MAGNETIC CHIP DETECTOR MISSING. R&R MAGNETIC CHIP DETECTOR IAW AMM 49-27-04. OPS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME.