N14177
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N14177' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N14177' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20260713008Battery Pack · inoperativeFWD INTERIOR CABIN EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED FWD INTERIOR AISLE EMERGENCY LIGHT. OPS CHECK FAIL. REMOVED AND REPLACED BATTERY.SDR JJBA20260713007Battery Pack · inoperativeLEFT EXTERNAL EMERGENCY LIGHT INOPERATIVE. FWD NR 1 EMERGENCY BATTERY HAS LOW VOLTAGE. REMOVED AND REPLACED LT FWD LOWER EXTERNAL EMERGENCY LIGHT. OPS CHECK FAIL REMOVED AND REPLACED BATTERY. OPS CHECK SAT.SDR JJBA20260702001Engine · shutdownENGINE 1 SHUTDOWN IN FLIGHT DURING CLIMB. REMOVED AND REPLACED ENGINE NR 1. OPS/LEAK CHECK SAT.SDR JJBA20260423025Skin · canningAPU SKIN OIL CANNING UPPER BETWEEN PROFILES, SIDE LH. REPAIRED APU COWLING SKIN.SDR JJBA20260423022Thrust Reverser · damagedSKIN DAMAGE LOWER INBOARD REVERSER LH. A REINFORCEMENT WAS INSTALLED. THE REPAIR WAS COMPLETED WITH NO ISSUED.SDR JJBA20260423024Skin · chafedAPU COWLING SHEAR PANEL HAS SEVERAL CHAFING ON SKIN. PERMANENT REPAIR WAS PERFORMED.SDR JJBA20260423023Skin · damagedAPU COWLING INTERNAL SKIN GOUGE-DENT. PERMANENT REPAIR WAS PERFORMED.SDR JJBA20260423020Skin · dentedMAIN DOOR SEVERAL DENT ON UPPER SKIN. DENT ASSESSMENT WAS PERFORMED. DENT 1 - NO ACTION REQUIRED ALLOWABLE DAMAGE. DENT 2 - NO ACTION REQUIRED ALLOWABLE DAMAGE ALSO AFTER INSPECTION, REWORKED AREA WAS FOUND ON LOWER AFT MAIN DOOR. PERMANENT REPAIR WAS PERFORMESDR JJBA20260423018Skin · scratchedSCRATCH BETWEEN FR 22 AND FR 23 AND STGR 13 FUSELAGE RH. SCRATCH ASSESSMENT WAS PERFORMED. NO ALLOWABLE DAMAGE. BLEND OUT AND THICKNESS WAS PERFORMED. NO ALLOWABLE DAMAGE. RESPIRED PERFORMED. NO ADDITIONAL INSPECTION REQUIREDSDR JJBA20260423021Gusset · corrodedCORROSION BEYOND LIMITS ON CENTER FUSELAGE IV FLOOR STRUCTURE, LATERAL SILLS BETWEEN FR61-FR33, GUSSET BEAN HAY BETWEEN FR59 AND FR62 BEAM LH. REPLACED THE GUSSET AND SILLS.SDR JJBA20260423019Skin · dentedBAGGAGE DOOR SKIN HAS SEVERAL DENTS. DENTS WERE EVALUATED AND FOUND ALLOWABLE DAMAGE DENTS 2, 3, AND 6. DENTS 1 AND 4 THE DENTS ARE LOCATED IN THE SHADED AREAS AND DAMAGE IS NOT PERMITTED. THE REPAIR WAS PERFORMED.SDR JJBA20260423026Inlet · damagedENG RH AIR INLET MODULE ACUSTIC INNER SKIN SEVERAL DAMAGES. REMOVED AND REPLACED ENG RH AIR INTAKESDR JJBA20230818005Coupling · leakingBLEED 2 LEAK ON EICAS DURING CLIMB THROUGH FL13. PERFORMED OPS CHECK OF THE AIR BLEED SYS. OPS CHECK FAILED. PERFORMED LEAKAGE CHECK. R & R SLEEVE ON DUEL TEMP CONTROLLER. R & R BOOT ON HEAT EXCHANGER EXHAUST. CLEANED AIR START ADAPTER CHECK VALVE. OPS CHECK SDR JJBA20230712010Unknown · unknownQTY (1) HOLE BORE IS NICKED, C/TO RH WING SPAR 3/TORQUE BOX #1 ATTACHMENT LOWER POSITION #2. HOLE OVERSIZED.SDR JJBA20230705002Unknown · unknownAT CF IV AREA, CORROSION FOUND ON MIDDLE GUSSET UNDER TOILET AREA BTW FR 59-61. MIDDLE GUSSET REPLACED WITH NEW ONE. FOLLOWING REMOVAL OF GUSSET, OMEGA BEAM FOUND CORRODED. BEAM REPAIRED WITH 2 DOUBLERSSDR JJBA20230620018Unknown · unknownCRACKS SUSPECTED (9X) ON RH SKIN AROUND FASTENERS BTW FR 77-80 BTW STR 3R-9R. SKIN REPAIRED WITH 2 DOUBLERS AND 7 BUSHINGSSDR JJBA20230705005Unknown · unknownCORROSION SUSPECTED ON REAR FUSELAGE I LH LATERAL SKIN INNER SURFACE BTW FRAME 60 & 61 AT STR 19L. SPLICE REPAIR ON LH REAR FUSE 1 STRINGER 19L, BTW FR 60-62SDR JJBA20230705004Unknown · unknownCF1, CRACK FOUND ON LH OMEGA BEAM #2 FLOOR STRUCTURE BTW FR 23-24. BEAM REPAIRED WITH A DOUBLER.SDR JJBA20230705003Unknown · unknownCRACKS FOUND ON TOP OVERHEAD MIDDLE FRAME LH + RH SIDE AROUND NUT PLATE ON WINDSHIELD SURROUND STRUCTURE COCKPIT AREA.TOP OVERHEAD MIDDLE FRAME LH + RH SIDE INSTALLED REPAIR DOUBLERS.SDR JJBA20230131024Engine · contaminatedSMOKE IN FLIGHT DECK AND FORWARD CABIN AFTER DEPARTURE. FOUND EVIDENCE OF DE-ICE FLUID IN BOTH ENGINES AND COWLING. CLEANED AREA, PERFORMED ENGINE RUNS. OPS CHECK SAT.SDR JJBA20220808002Light · inoperativeFUSELAGE EMERGENCY LIGHT FORWARD OF LH WING INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT LAMP FORWARD OF LH WING. OPS CHECK FAILED. REMOVED AND REPLACED EMERGENCY LIGHT #1 BATTERY. OPS CHECK SAT.SDR JJBA20220531063None · noneFWD CABIN EMERGENCY LIGHT TRACK MISSING. INSTALLED EMERGENCY LIGHT STRIP AT SEAT 1ASDR JJBA20220216016Not Reported · not reportedEMERGENCY FLOOR LIGHT STRIP RIPPED OFF BY SEAT 1A. RESECURED 1A EMERGENCY LIGHT STRIP.SDR JJBA20220113018Not Reported · not reportedSUPPLEMENTAL (NEW) INFORMATION: AUTO PRESSURIZATION FAIL. R&R MAIN DOOR FRAME SEAL. R&R SIDE HINGED MAIN DOOR RUBBER TRIM SEAL. OPS CHECK SAT.SDR JJBA20210113019Door · noisyLOUD NOISE COMING FROM UPPER LH CORNER MCD. R&R MAIN DOOR FRAME SEAL. LEAK CHECK SAT AND REINSTALLED MAIN DOOR LINING.SDR JJBA202201183018Cabin Pressure · failedAUTO PRESSURIZATION FAILSDR JJBA20211119032Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPS CHECK PASS.SDR JJBA20210406044Seat Track · corrodedRH INBD SEAT TRACK SUPPORT BEAM FROM FRAME 24 TO BETWEEN FRAMES 29-30 HAS SIGNS OF CORROSION AND PAINT DAMAGE THROUGHOUT THE TOP LENGTH (RIVETS). REMOVED CORROSION RH, IB SEAT TRACK SUPPORT BEAM GUSSET FR 24-29, FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLEDSDR JJBA20210404049Flap Track · wornRH OB FLAP OB FLAP TRACK SHOWS SIGNS OF WEAR IN MULTIPLE AREAS. REMOVED AND REPLACED RH OB FLAP OB FLAP TRACK.SDR JJBA20210404045Seat Track · corrodedRH INBD SEAT TRACK SUPPORT BEAM FROM BETWEEN FRAMES 29-30 TO BETWEEN FRAMES 35-36 HAS SIGNS OF CORROSION AND PANT DAMAGE THROUGHOUT TOP LENGTH (RIVETS). REMOVED CORROSION AT RH IB SEAT TRACK SUPPORT BEAMS FR 30-35. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALSDR JJBA20210402046Seat Track · corrodedLH INBD SEAT TRACK SUPPORT BEAM FROM BETWEEN FRAMES 29-30 TO BETWEEN FRAMES 35-36 HAS SIGNS OF CORROSION AND PAINT DAMAGE THROUGHOUT THE TOP LENGTH (RIVETS). REMOVED AND REPLACED GUSSET FROM LH IB SEAT TRACK SUPPORT FR 30 @ 35.SDR JJBA20210402043Seat Track · corrodedLH INBD SEAT TRACK SUPPORT BEAM FROM FRAME 24 TO BETWEEN FRAMES 29-30 HAS SIGNS OF CORROSION AND PAINT DAMAGE THROUGHOUT THE TOP LENGTH (RIVETS). REMOVED AND REPLACED GUSSET FROM FR 24 @ 29 ON LH INBD SUPPORT BEAMSDR JJBA20210402042Fitting · corrodedSIGNS OF POSSIBLE CORROSION ON 2 EACH FITTING FOR FILLING AND OVERFLOW LINE AT FLOOR BOARD IN AFT LAV APPROX FRAME STA 60. EWIS INSTALLED. CORROSION ON GUSSET-BEAD HAT FOUND TO BE OUT OF LIMITS. REMOVED RH AFT PRESSURE. REMOVED DAMAGED GUSSET. DRILLED NEW GUSSSDR JJBA20210310048Support · crackedCENTER FLOOR BEAM (L) SUPPORT BRACKET CRACKED AFTER RM 21 STE 21R. REMOVED AND INSTALLED SUPPORT BRACKET.SDR JJBA20210309047Seat Track · wornFIRST OFFICERS SEAT TRACKS WORN. UPON EVAL FIRST OFFICER COCKPIT SEAT TRACKS ARE OUT OF LIMITS. REMOVED AND INSTALLED SEAT TRACKS.SDR JJBA202008174009Battery Pack · inoperativeMULTIPLE EXTERIOR AND INTERIOR LIGHTS INOPERATIVE. R&R EMERGENCY BATTERY POSITION #1 AND #4. OPS CHECK SAT.SDR JJBA202007275003Unknown · odorSTRONG RUBBER BURNING SMELL THROUGH CABIN AND COCKPIT AROUND 24,000 FEET FOR ABOUT 2 MINUTES. PERFORMED GVI OF #1 AND #2 PACK AREA, PRECOOLER AND INTERIOR OF CABIN AND COCKPIT WHILE APU OFF. NO DEFECTS NOTED. TROUBLESHOT ABNORMAL SMELL. NO RUBBER BURNING SMELLSDR JJBA202006297007Battery Pack · inoperativeRH FWD EXTERNAL LIGHT INOPERATIVE. R&R EMERGENCY LIGHT LAMP. OPS CHECK FAILED. ALSO, FOUND MULTIPLE INTERNAL EMERGENCY SIGNS IN GALLEY AREA TO BE INOPERATIVE AS WELL. TROUBLESHOT TO #2 EMERGENCY BATTERY PACK. R&R #2 BATTERY PACK. OPS CHECK SAT.SDR JJBA202005297008Connector · disconnectedFOUR EMERGENCY LIGHTS INOPERATIVE AS FOLLOWS: ABOVE SERVICE DOOR, GALLEY CEILING, SERVICE DOOR EXTERIOR LIGHT, AND LIGHT ON WALL IN FRONT OF SEAT 3CD. FOUND CONNECTOR CONNECTING TO GALLEY CEILING PANEL 234ARC TO BE DISCONNECTED. RECONNECTED. OPS CHECK SATISFSDR JJBA201902287014Case · crackedAPU EXHAUST EXTERNAL CASE HAS CRACK LEFT SIDE. R&R APUSDR JJBA201807101001Handle · out of adjustLEFT EMERGENCY EXIT HANDLE UPSIDE DOWN. ADJUSTED PASSENGER CABIN EMERGENCY EXIT HANDLE. NO DEFECTS NOTED.SDR JJBA20180131013Wire Harness · chafedNR 2 ENGINE FIRE DETECTOR FAIL MESSAGE DURING TAKE OFF. RESET SYSTEM. PERFORMED HIGH POWER RUN. NO MESSAGE PRESENT. NO DEFECTS NOTED. FOUND PYLON FIRE LOOP DAMAGED. CHAFE FOUND IN HARNESS. . R & R THE NR 2 ENGINE FIRE DETECTOR HARNESS. PERFORMED AN OPS CHECSDR JJBA20180126012Clamp · disconnectedNR 2 ENGINE FIRE DETECTION FAIL MESSAGE DURING TAKE OFF. DURING RUN UPS. PERFORMED WIRING CHECKS OF THE FIRE DETECTION SYSTEM. NO DEFECTS NOTED. PERFORMED ENGINE RUN AT HIGH POWER SETTING. ENGINE RUN TESTED SATISFACTOR. ON INSPECTION OF FIRE LOOP, FOUND SDR JJBA20171029009Unknown · odorODOR OF SMOKE IN THE ACFT AT 21000 FT. ODOR WENT AWAY AT 19000 FT. NO ODOR NOTED FOR THE REMAINDER OF THE FLIGHT. PERFORMED FIM 21-20-00-810-801-A. COMPLIED WITH FIM 21-20-00-810-803-A. OPS CHECKED GOOD NO OTHER DEFECTS NOTED.SDR JJBA20170528035Light · unknownROW 18 LT AND RT EMERGENCY EXIT LIGHTS INOPERATIVE. AFT FACING OVERHEAD LIGHT INOPERATIVE. PERFORMED OPS CHECK OF THE EMERGENCY EXIT LIGHTS, OPS CHECKED GOOD.SDR JJBA20170419011Bulb · inoperativeCEILING EMERGENCY LIGHT INOPERATIVE. R & R THE BULBS. OPS CHECKED SAT.SDR JJBA20170411009Smoke Warning · false activationLAVATORY SMOKE DETECTOR EICAS MESSAGE. VERIFIED NO SMOKE PRESENT. INSPECTED WIRES, TESTED SYSTEM NO FAULTS FOUND OPS CHECKED GOOD.SDR JJBA20170224017Display · malfunctionedEICAS SCREEN BLANKED OUT IN FLIGHT AT FL340 AND THERE WAS A BURNING ODOR ASSOCIATED. NO SMOKE WAS OBSERVED. THE EICAS SCREEN CAME BACK ON 20 SECONDS LATER AND THE ODOR DISSIPATED AFTER ABOUT 1 MINUTE. FOUND EICAS DISPLAY ABNORMALLY HOT. SWAPPED MFD2 AND EICSDR JJBA20170208007Inverter · inoperativeEMERGENCY EXIT LIGHT AT FWD SERVICE DOOR INOPERATIVE. R & R THE INVERTER. OPS CHECKED GOOD.SDR JJBA20170120017Connector · unsecureEMERGENCY LIGHT ON GALLEY DOOR INOP. RESECURED LIGHT CONNECTOR. OPS CHECK SAT.
Back to N14177