N1427A
Service difficulty reports · 457
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA201902253325Warning Message · false activationAFTER PUSHBACK RECEIVED AN APU GEN OFF MESSAGE, ONE RESET ATTEMPT AFTER 5 MINUTES, RECEIVED THE MESSAGE AGAIN. TROUBLESHOT IAW FIM 49-11 F/T 987. RESET THE APU GENERATOR, RAN APU AND APPLIED A LOAD TO THE SYSTEM, NO MESSAGE OR FAULTS NOTED.SDR UIEA2019021543219Oil System · lowAFTER ENGINE START R GEN DRIVE EICAS WITH R GEN DRIVE DISC LIGHT ILLUMINATED ON OVERHEAD PANEL. LIGHT REMAINED ON APPROXIMATELY 45 SEC THEN WENT OUT.(<P>PERFORMED FIM TASK 24-20 FT 801, FOUND IDG LOW IOL PRESSURE. SERVICED IDG PER 12-13-03-613-027 AND PERFORMESDR UIEA2019021103180Idg · overservicedAFTER ENGINE START RIGHT GENERATOR DRIVE EICAS WITH DRIVE LIGHT ILLUMINATED ON OVERHEAD PANEL. REMAIN ON FOR OVER 1 MINUTE THEN WENT OUT. (<P>FOUND IDG TO BE OVER SERVICED, PERFORMED IDG OPERATIONAL TEST IAW AMM 24-11-00-715-006. TEST PASS NO FURTHER DEFECTS NSDR UIEA2019020863139Fire Loop · abnormalR ENG FIRE LP 2 STATUS MESSAGE(<P>TRANSFER TO MDDR 106994 IAW DDG 26-11-01-01</P><P>LP 1040431: R/R R/H ENGINE UPPER AFT FIRE LOOP IAW AMM 26-11-02, ENGINE FIRE TEST IAW AMM 26-11-00, NO FAULTS NOTED, NO MSG NOTED @ THIS TIME. THIS ACTION CLOSES MDDR 106994 ASDR UIEA2019020503122Wire · missingPRE-FLIGHT INSP FOUND R IDG SWITCH COVER SHEER WIRE MISSING , ALSO FOUNF R GEN FIELD LIGHT(<P>RECONNECTED R IDG PER AMM 24-11-01 OPS TEST OK FIELD LIGHT OUT </P>)SDR UIEA2019020403102Apu · malfunctionedAPU FAULT.(<P>SUSPECT APU COLD SOAKED ALLOWED SUFFICENT GROUND TIME PERFORMED 3 SUCCESSFUL STARTS NO FAULTS OK FOR SERVICE IAW AMM 49-11-00.<BR /></P><P><BR /></P>)SDR UIEA2019012703036Start Valve · faultyIN FLT L STARTER CUTOUT AND L ENGINE STARTER MESSAGE DISPLAY NOTE LEFT ENGINE VALVE LIGHT DOES NOT DISPLAY IN ADDITION LEFT ENGINE BLEED VALVE EICAS DISPLAYED TWICE BUT CLEARED STARTER MESSAGE DID NOT CLEAR. REMOVED AND REPLACED LEFT ENGINE START VALVE IAW AMMSDR UIEA2019012503027Fuel Filter · defectiveLT ENG FUEL FILTER STATUS MESSAGE. NO ABNORMAL ENG INDICATIONS OBSERVED.(<P>R/R FUEL FILTER PER FIM 73-11 FT 803. RAN ENGINE LEAK CHECK GOOD. OPS CHECKS GOOD MSG CLEARED.</P>)SDR UIEA2019011400087Warning System · false activationSTATUS MESSAGE AFT EQUIP EXHAUST FAN(<P>PERFORM FIM 21-58-PERFORMED OPS CHECK TEST OK PER AMM 21-26-00</P>)SDR UIEA2019010700028Warning System · false activationRT ENGINE FIRE LOOP 2 EICAS MESSAGE(<P>TRANSFER TO MDDR 105598 IAW MEL 26-11-01-01</P><P>LP 1047887-M3 PERFORMED OPERATIONAL TEST FIRE LOOP SYSTEM IAW AMM 26-11-00 NO FAULTS FOUND OPS CHECK GOOD CLEARED MDDR 105598 PLACARD REMOVED </P>)SDR UIEA2019010900050Oxygen Mask · inoperativeSUPERNUMERARY SEAT RIGHT O2 MASK INOP.(<P>DEFERRED. MDDR 105634. SECURED O2 MASK AND PERFORMED OPS CHECK IAW AMM 35-11-51, OPS NORMAL, MDDR CLOSED.<BR /></P>)SDR UIEA201812212888Switch · unknownRH CTR FUEL PUMP MESSAGE ON EICAS.(<P>TRANSFERRED TO MDDR# 104786 DUE 29DEC18, CAT "C" MXCTRL RA OPENED CB'S @ P6F21 "RIGHTFUEL OTBD PUMP" PER MEL 28-22-02A. PLACARD INSTALLED.<BR /></P><P><BR DATA-MCE-BOGUS="1" /></P><P>R&R FUEL PRESSURE SWITCH IAW AMM 28-42-SDR UIEA2018122092881Circuit Card · malfunctionedRT ENG FIRE LOOP 2 EICAS MSG(<P>TRANSFER TO MEL 26-11-01-01 CAT C DUE 29DEC18 MMDR# 104772.</P><P>PERFORMED VISUAL INSPECTION OF RH ENGINE FIRE LOOP, NO DEFECTS NOTED R/R R ENGINE FIRE LOOP CARD (M684) IAW AMM 26-10-01 OPS CHECK GOOD, THIS CLEARS NDDR 104772.<SDR UIEA2018112632682Gcu · malfunctioned APU WILL NOT SUPPLY ELECTRICAL POWER.(<P>PLACED ON MDDR 103295,REMOVED AND REPLACED APU GCU IAW AMM 24-22-02 OPS CHECK NORMAL ,THIS CLEARS MDDR 103295.</P>)SDR UIEA2018112102672Duct · unknownBEFOREE ENG START DUCT PRESSURE WAS 15 PSI. AS #2 ENG WAS STARTING DUCT PRESSURE CLIMBED TO 30 PSI(<P><SPAN>RAN / BOTH ENG'S TO OPS CHECK DUCT PRESSURE. OPS CHECK GOOD AT THIS TIME IAW AMM / 36-21-00 & 72-10-00</SPAN></P>)SDR UIEA201811212658Warning Message · false activationPRIOR TO ENGINE START BOTH DUCT PRESSURES FLUCTUATE BETWEEN 15 AND 20 PSI (<P>PERFORMED OPS CHECK OF PNEUMATIC SYS IAW AMM 49-52-00 OPS CHECKED GOOD 35 PSI STEADY WITH NO PACKS RUNNING OPS CK GOOD </P>)SDR UIEA2018111302591Idg · failedRIGHT GENERATOR FAILED IN FLT. R & R THE RT ENGINE IDG IAW AMM 24-11-01,OPS CHECKED GOOD.SDR UIEA2018111652622Apu · unknownON STARTING FIRST ENGINE(#2), APU VERY SLOW TO INCREASE PRESSURE TO START MINIMUM.(<P>PERFORMED DRY MOTOR RUN ON NO.2 ENG. PRESSURE HELD NORMAL AT 30 PSI, OPS CKS. OK IAW 71-00-00.</P>)SDR UIEA2018110902554Control Unit · inoperativeCREW OXYGEN PRESSURE INDICATOR INOPERATIVE. R & R THE CREW OXYGEN AVERAGE UNIT IAW 35-11-06. OPS CHECKED GOOD.SDR UIEA2018110202486Indication Sys · inoperativeCREW OXYGEN INDICATION INOPERATIVE. PERFORMED AN INSPECTION OF THE OXYGEN BOTTLE IAW AMM 35-11-00, OPS CHECKED GOOD.SDR UIEA2018103002429Adc · malfunctionedDURING TAXI OUT, RECEIVED A LEFT EEC ENGINE MODE AND RT EEC MODE ADVISORY MESSAGE. REMOVED AND REPLACED RIGHT ADC IAW AMM 34-12-01. OPS CHECKED GOOD.SDR UIEA2018102202311Status Message · false activationCABIN ALT AUTO 1 STATUS MESSAGE APPEARS AFTER AC TRANSFER DURING ENGINE START. ACCOMPLISHED CABIN CONTROLLER BITE PER FIM 21-31-809, FAULTED SELECTOR, NO FAULT INDICATED WHEN SELECTED VERIFY. FAULT CLEARED. TRANSFERED POWER SEVERAL TIMES 24-22-00 NO FAULTS NOTSDR UIEA2018102502344Battery · not reportedMAIN AIRCRAFT BATTERY NEEDS REPLACEMENT. R&R AIRCRAFT MAIN BATTERY IAW 24-31-01. OPS CHECK NORMAL.SDR UIEA2018102502343Fire Loop · brokenRT ENGINE AFT FIRE LOOP TERMINAL BROKEN. R&R RT ENG FIRE LOOP IAW AMM 26-11-02. OPS CHECK NORMAL.SDR UIEA2018102502342Fire Loop · damagedRT ENG FIRE LOOP TEMP REPAIR. INSTALLED TEFLON TUBING ON EXPOSED PORTIONS OF WIRE W5324-455R16 IAW AMM 26-11-21.SDR UIEA2018101602273Transducer · faultyAPU INOP. REMOVED AND REPLACED TRANSDUCER MOTIONAL MONOPOLE, APU OPS CHECK NORMAL IAW AMM 49-61-02.SDR UIEA2018101002232Status Message · false activationSTATUS MESSAGE AFT EQ EXH FAN NR 2. PERFORMED FIM 21-26-FT 8069 NO FAULTS NOTED AT THIS TIME.SDR UIEA2018101002217Ecu · malfunctionedAPU INOP. REMOVED AND REPLACED APU ECU IAW AMM 49-61-05 OPERATIONAL CHECK NORMAL.SDR UIEA2018100802204Hsi · malfunctioned"WXR DSPY" MESSAGE ON CA HSI INTERMITTENTLY THROUGHOUT FLIGHT. REPEAT WRITE-UP. R&R HSI.SDR UIEA2018100802205Light · inoperativeLT ENG OIL PRESSURE LIGHT NOT ILLUMINATED. RELAMPED PER AMM 33-16-02.SDR UIEA2018100802202Display · intermittentWX DISPLAY ( WXR DSPY) INTERMITTENT ON PIC HSI (+TERR DISY+TCAS). PERFORMED FIM TASK 34-22 FT 804, NO FURTHER DEFECTS NOTED. NO MX PROCEDURE NECESSARY FOR INTERMITTENT FAILURE.SDR UIEA2018100802200Generator · faultyWEATHER DISPLAY (WXR DSPY) INTERMITTENT ON CAPT'S HSI. R&R GENERATOR ASSY-ELECTRONIC FLT IAW AMM 34-22-01, PERFORMED OPS CK, OPS CHECK SATISFACTORY.SDR UIEA2018100802198Warning System · false activationYELLOW " WXR DSPY" MESSAGE DISPLAYED ON CAPT'S EHSI NUMEROUS TIMES, BUT INTERMITTENTLY. PERFORMED TEST OF WEATHER RADAR SYSTEM IAW AMM 34-43-00, OPS TEST GOOD AT THIS TIME.SDR UIEA2018100402183Status Message · false activationAFT EQ EXH FAN STATUS. COMPLIED WITH SYSTEM CK, IAW AMM CH 21-58-41 NO FAULTS NOTED ERASE PROCEDURE IAW MM 31-41-00.SDR UIEA2018100202165Ecu · faultyAPU INOP. R&R APU ECU IAW 49-61-05 OPS GOOD.SDR UIEA2018091801999Warning System · false activationSTATUS MESSAGE RT ENG OH LP 2. PERFORMED OPERATIONS TEST FOUND NO FAULTS. CLEARED MESSAGE AND OPS CHECKED GOOD IAW AMM 26-15-00.SDR UIEA2018091601986Warning System · false activationAFT EQ EXH FAN 2 STATUS MESSAGE DISPLAYED. RECYCLED AFT EQ EXH FAN 2 BREAKER MESSAGE CLEARED IAW AMM 21-58-41.SDR UIEA2018091401972Solenoid · failedAPU INOP. REMOVED AND REPLACED APU FUEL SOLENOID PER AMM 4931-03. PERFORMED LEAK & OPS CHECK.SDR UIEA2018091001933Transmitter · faultyUPON INSPECTION FOUND LEFT ENG OIL PRESSURE LIGHT INOP. REMOVED AND REPLACED OIL PRESS TRANSMITTER. OPS AND LEAK CHECK NORMAL AMM 79-32-01.SDR UIEA2018090901930Detector · defectiveINTERMITTENT R FIRE LOOP 2 STATUS MSG. REMOVED AND REPLACED DETECTOR ASSY UPPER AFT IAW AMM 26-11-02 OPS CHECK NORMAL.SDR UIEA2018090501891Bleed Air Sys · fluctuatesAPU DUCT PRESSURE BEFORE ENGINE START FLUCUATES BETWEEN 15-T0 22 PSI. PERFORMED AIR SUPPLY DISTRIBUTION OPS TEST IAW AMM 36-11-00 NO DEFECTS NOTED NO FLUCTUATION NOTED AT THIS TIME.SDR UIEA2018090401877Generator · inoperativeAPU GEN INOP. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01. OPS CHECK GOOD.SDR UIEA2018090301876Start Valve · faultyRT STARTER INOP. REMOVED AND REPLACED START VALVE IAW AMM 80-11-02 OPS AND LEAK CHECK GOOD.SDR UIEA2018090401889Unknown · malfunctionedLT ENG OIL PRESS INDICATOR LIGHT NOT ILLUMINATED W/ ENGINE SHUTDOWN. PERFORMED ENGINE ILDE RUNS IAW AMM 71-00-00. OPS CHECK GOOD AT THIS TIME.SDR UIEA2018083001848Wire · damagedRT ENG FIRE LOOP 2 INTERMITTENTLY DISPLAYED(STATUS MESSAGE). REMOVED AND REPLACED WIRE W5306-455R-16 AT RT ENG REPLACED WITH NEW BMS513-67 WIRE MATERIAL, RE CLAMPED & RETERMINATED WIRE TO ENG LOOP 2 TS682% A & TS683 A IAW WDM 26-11-21, SWPM 20-10-12 & 20-10-15SDR UIEA2018090401883Fire Loop · damagedRIGHT ENGINE FIRE LOOP2 PERMANENT REPAIR. C/W HIGH TEMP TAPE IAW SWP 20-10-13, WIRE W-5324-455R-16 TO BE REPLACED DURING THE NEXT A CHECK.SDR UIEA2018082801826Generator · faultyAPU LOW OIL SHUTDOWN. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01. OPS CHECK GOOD.SDR UIEA2018082701806Warning System · false activationRIGHT ENGINE FIRE LOOP 2 STATUS MESSAGE DISPLAYED AFTER NR 2 ENGINE START. NO CURRENT FAULTS, PERFORMED FIRE/OVERHEAT TEST IAW AMM 26-11-00.SDR UIEA2018082101763Warning System · false activationRT ENG NR 2 FIRE LOOP STATUS MESSAGES, INTERMITTENT DURING FLIGHT. PERFORMED FIRE DETECT OPS CHECK IAW AMM 26-11-00, RT ENG LOOPS. NO DEFECTS NOTED.SDR UIEA2018082101759Sensor · faultyAPU AUTO SHUT DOWN. BITE CODE "REVERSE FLOW". T/S IAW FIM 49-11 FT 987. R&R LC TT SENSOR IAW AMM 49-61-03. APU OPS CHK GOOD PER 49-00-00. ERASED ECU PER FIM 49-11 FT 987. NO DEFECTS AT THIS TIME.
Back to N1427A