N1427A
Service difficulty reports · 457
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1427A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019082305262Warning Message · false activationDURING DESCENT, RECEIVED EICAS ADVISORY "R FWD WINDOW". RAN QRH AND COMPLIED, MSG EXTINGUISHED. PERFORMED WINDOW HEAT CONTROL UNIT BITE. NO FAULTS AND NO EICAS MESSAGES AT THIS TIME. PERFORMED BITE PER AMM 30-41-01-861-001. OPS CHECK TESTED OK.SDR UIEA2019082105244Hook And Loop · missingEVAS SYSTEM: HOOK AND LOOP STRIP FOR IVU ON THE TOP GLARE SHIELD NOT INSTALLED ON CA/FO SIDES. INSTALLED LOOP SIDE OF FASTENER FOR COCKPIT SMOKE VISION SYSTEM IAW EO 6725A222.SDR UIEA2019082205260Unknown · malfunctionedFWD RIGHT WINDOW HEAT INOP. PERFORMED BITE CHECK OF WINDOW HEAT CONTROLLERS PER AMM 30-41-00. NO FAULTS NOTED, MESSAGE CLEARED.SDR UIEA2019081605196Connector · damagedRIGHT SYS RADAR DISPLAYS ATT DISAGREE LEFT SYS ON OK. PERFORMED R WXR TEST IAW FIM 34-43 F/T 805. WXR FAIL ATT. SWAPPED WX RADAR RT PER AMM 34-43-01. NO HELP. WXR ATT FAULT WHEN USING RT WXR. INSPECTED WXR ANTENNA PER AMM 34-43-00. NO DEFECTS. FOUND D4769 PSDR UIEA2019081605197Warning Message · false activationLEFT PACK TEMP CAUTION MESSAGE. PERFORMED LEFT PACK TEMPERATURE CAUTION B9 TE TEST PROCEDURES IAW B767 300 FIM 21-51 FT 844. RE SAT THE INITIAL BITE TEST OK EVERYTHING WORKING GOOD AT THIS TIMESDR UIEA2019081655179Wire Harness · malfunctionedA/C HAS A HISTORY OF LEFT WING FUEL QTY INDICATIONS ISSUES. REPLACED L/W FQIS WIRE HARNESS, PERFORMED BITE CHECK, BITE CHECK FAILED IAW AMM 28-41-09.SDR UIEA2019081505192Heat Exchanger · crackedRIGHT AIR CONDITIONING MAIN HEAT EXCHANGER CRACKED. REMOVED & REPLACED THE RT SECONDARY HEAT EXCHANGER IAW AMM 21-51-02. PERFORMED SATISFACTORY LEAK CHECKED IAW AMM 21-51-02.SDR UIEA2019081505191Transducer · malfunctionedWHILE PERFORMING ENGINE RUN, RT EFC CHAN 2 MESSAGE SHOWS ON EICAS DISPLAY. REMOVED AND REPLACED NR 2 ENGINE OUTBD THRUST REVERSER TRANSDUCER IAW AMM 78-36-03. PERFORMED SATISFACTORY OPS CHECK IAW AMM 71-00-00, NO DEFECTS NOTED, EICAS MESSAGE DID NOT COME BACKSDR UIEA2019081505190Ecu · unknownAPU BITE MESSAGE ON EICAS DURING APU RUN. NO FAULTS ON ECU. REMOVED AND REPLACED APU ECU IAW AMM 49-61-05.</P>)SDR UIEA2019081505189Isolation Valve · malfunctionedN1 ENGINE FAILS TO SPOOL ABOVE 20% N2. REMOVED AND REPLACE RT ISOLATION VALVE IAW AMM 36-11-04. ACCOMPLISHED SATISFACTORY OPERATIONAL AND LEAK TEST IAW AMM 71-00-00, 36-11-04. NR 1 ENGINE SPOOL UP WAS 26% N2 IAW AMM 71-00-00. NO DEFECTS NOTED.SDR UIEA2019081505188Connector · disconnectedMAIN CARGO LOOP 1 MESSAGE SHOWS ON LOWER EICAS DISPLAY. CONNECTED THE SMOKE DETECTOR M12213 1A2D ELECTRICAL PLUG IAW SWPM 20-60-06 SHT. PERFORMED SATISFACTORY MAIN CARGO SMOKE DET OPS CHECK IAW SMPM 26-14-00.SDR UIEA2019081505187Warning Message · false activationAPU BITE MESSAGE SHOWS ON LOWER EICAS DISPLAY.(<P>PERFORMED SATISFACTORY T/S AT LOWER EICAS DISPLAY IAW FIM 49-11 FAULT TREE 987. APU MESSAGE ISN'T SHOWING ON DISPLAY.</P>)SDR UIEA2019081505186Monitor · malfunctionedWHILE PERFORMING ENGINE RUNS, ENGINE VIBE BITE MSG SHOWS ON EICAS.(<P>REMOVED AND REPLACED ENG AVM IAW AMM 77-31-03. PERFORMED SATISFACTORY ENG AMM OPS CHK IAW AMM 77-31-00.</P>)SDR UIEA2019081505181Lead · damaged#2 ENGINE INBD LOWER IGNITION LEAD HAS ARC DAMAGE.(<P>REMOVED & REPLACED #2 ENG #1 SYSTEM IGNITOR LEAD IAW AMM 74-21-01. ASSET # 0019077, 0019114, 0018917 OPS CHECK ACCOMPLISHED ON TASK # T2031.</P>)SDR UIEA2019081505180Tube · cracked#1 ENGINE TURBINE COOLING AIR TUBE CRACKED AT 8:30 POSITION.(<P>REMOVED AND REPLACED #1 ENG TURBINE COOLING AIR MANIFOLD @ 8:30 POSITION IAW AMM 75-24-03. AS# 0018938, AS# 0013164, AS# 0019069.</P>)SDR UIEA2019081505178Plenum · damagedL/H A/C PACK PLENUM ON AFT SIDE OF AIR CYCLE MACHINE HAS LARGE HOLE TOP FWD SIDE AND SMALL 1 SQ IN HOLE BOTTOM FWD SIDE.(<P>REMOVED AND REPLACED THE L/H A/C PACK PLENUM IAW AMM 21-51-02. PERFORMED SATISFACTORY LEAK CHECK IAW AMM 21-51-02 WITH NO LEAKS NOTED ATSDR UIEA2019081505175Blade · damaged#2 ENG LE FAN BLADE DENT MARKED WITH DOT.(<P>UPON FURTHER EVALUATION, FOUND DAMAGE TO BE NICK IN AREA "D" OF BLADE WITH ALLOWABLE DAMAGE TO 0.060". MEASURED 0.040". ASSET # 0017552 WITHIN ALLOWABLE LIMITS IAW AMM 72-31-02. NO ACTION REQUIRED.</P>)SDR UIEA2019081505174Connector · not seatedNR 1 ENGINE, DURING START, N2 RISING UP TO 20% ONLY AND PRESSURE MANIFOLD FLUCTUATES AROUND 15-20 PSI. SEATED THE CONNECTOR PLUGS ON NR 1 HP CONTROLLER AND PERFORMED SATISFACTORY NR 1 ENGINE START WITH NO FLUCTUATING IN MANIFOLD PRESSURE IAW AMM 71-00-00.SDR UIEA2019071904792Unknown · malfunctionedUNABLE TO START RIGHT ENGINE VIA AIR START, DUCT PRESSURE APPROX 10 PSI. LEFT ENGINE STARTED NORMALLY WITH PROPER DUCT PRESSURE, FOLLOWED BY CROSS BLEED TO START RIGHT ENGINE.(<P>PERFORMED SYS TEST OF CTR ISO VALVE SYSTEM IAW 36-11-00, NO FAULTS NOTED. PERFORMSDR UIEA2019071704775Sensor · faultyAPU AUTO SHUTDOWN ON GROUND BEFORE BLOCK-OUT.(<P>TRANSFERRED TO MDDR 114872 IAW DDG 49-11-01A, CATC, DUE DATE 26-JUL-19.</P><P>LP 1058751 - ITEM 1: REMOVED AND REPLACED APU INLET TEMP SENSOR IAW AMM 49-61-03. OPERATIONAL CHECK SATISFACTORY. MDDR 114872 CLOSEDSDR UIEA2019070904719Oil System · lowAPU SHUTDOWN - 0 OIL QUANTITY (<P>SERVICED APU OIL IAW AMM 12-10-00. APU OPS CHECK GOOD. NO DEFECTS NOTED </P>)SDR UIEA2019070304667Warning System · false activationAFT EQ COOLING FAN 2 STATUS MSG (<P>AFT EQ EXH FAN 2 DEFERRED PER MEL 21-58-05. THIS BECOMES DMI 114127, CAT 'C', DUE 12JUL19. <BR /></P><P>LP 1080455 - M6: C/W FIM TASK 21-26 FAULT TREE 809. FIM TEST PAST, NO DEFECTS NOTED. THIS CLEARS DMI #114127. MCC NOTIFISDR UIEA2019070104627Ecu · malfunctionedAPU PRODUCED 21 PSI FOR #2 ENGINE START AND ONLY 10 PSI FOR #1 ENGINE START. CROSS START REQUIRED. (<P>TRANSFERRED TO MDDR 114030 IAW MEL 49-11-01-01. PNEUMATIC FUNCTION OF APU INOP. CAT 'C', DUE 11-JUL-19. R&R APU SURGE BLEED OPS CHECK GOOD IAW AMM 49-53-01SDR UIEA2019063004623Isolation Valve · closedAPU ONLY PRODUCED 10 PSI FOR #1 ENGINE START. CROSS START REQUIRED TO START ENGINE 1.(<P>FOUND RT ISOLATION VALVE CLOSED. VALVE RESET, CYCLED, OPERATE OK REF 36-15-00.</P>)SDR UIEA2019060764400Idg · malfunctionedAFTER RIGHT ENGINE START, R GEN OFF EICAS MESSAGE DISPLAYED. FOLLOWED QRH PROCEDURE AND OPERATED NORMALLY.(<P>TRANSFERRED TO MDDR # 112777 PER MEL 24-30-01-01, CAT B. DUE DATE 09JUN19. ER 120 MNS RESTRICTED. DISPATCH YK @ 13:02Z. REMOVED AND REPLACED #2 IDG ISDR UIEA2019060704413Generator · malfunctionedAFTER RIGHT ENG. START, R GEN OFF EICAS APPEARED. PERFORMED QRH PROCEDURE AND CONTINUED FLIGHT. PERFORMED BITE TEST IAW FIM 24-20. NO FAULTS NOTED AT THIS TIME.SDR UIEA2019060604397Idg · overservicedAFTER RIGHT ENGINE START, R GEN OFF EICAS MSG. PERFORMED QRH PROCEDURE AND CONTINUED WITH FLIGHT.(<P>T/S IAW FIM 24-20 F/T 801 AND FIM 24-20 F/T 804 TABLE 102. RESET BPCU AND RE-SERVICED IDG REF 12-15-02. AFTER FINDING IT TO BE OVER-SERVICED BY 3/4 OF QT, RESSDR UIEA2019060654394Warning Message · false activationAFTER START, GOT "R GEN OFF". RECYCLED AND OPERATED NORMALLY. PERFORMED BITE TEST OK PER FIM 24-20. NO FAULTS NOTED AT THIS TIME.SDR UIEA201906054381Gcu · failed"R GEN OFF" ADVISORY AFTER R ENGINE START. RAN QRH AND CONTINUED NORMAL OPS. REMOVED AND REPLACED RH GCU IAW AMM 24-22-01. OPS CHECK GOOD AT THIS TIME.</P>)SDR UIEA201906054385Warning Message · false activationRIGHT BLEED ISOLATION VALVE EICAS MESSAGE OCCURS WHEN THE VALVE IS PRESSED OUT. CYCLED RIGHT BLEED ISOLATION VALVE MULTIPLE TIMES PER AMM REF 36-11-00. NO FAULTS NOTED.SDR UIEA2019060544388Apu · malfunctionedWHEN STARTING RIGHT ENGINE, APU DUCT PRESSURE WENT FROM 30 PSI TO 10 PSI. ENGINE START W/IN PARAMETERS. PERFORMED OPS CHECK IAW AMM 71-00-00. OPS CHECK GOOD AT THIS TIME.SDR UIEA2019051904231Unknown · malfunctionedLEFT MAIN FUEL PUMP INOP.(<P>TRANSFERRED TO MDDR 111871.</P><P>LP 1015740 - M4: LH MAIN FUEL PUMP OPS CHECK GOOD IAW AMM 28-22-00. THIS CLEARS DMI # 111871. MCC NOTIFIED. DISPATCH DP1540Z. </P>)SDR UIEA2019051704225Control Panel · faulty"GCS" BUTTON ON WX RADAR WILL NOT STAY PRESS.(<P>TRANSFER TO MDDR 111815 IAW DDG 34-43-01 DUE DATE 15 SEP-19.</P><P>LP 1015739 - M3: REMOVED AND REPLACED WXR CONTROL PANEL WITH REPAIRED UNIT. OPS CHECK IS GOOD. REF 767 AMM 34-43-02. THIS CLEARS DMI# 111815. SDR UIEA2019051004164Unknown · malfunctionedL ENGINE IN FLIGHT GOES TO GROUND IDLE, INSTEAD OF STAYING IN FLIGHT IDLE. EICAS MESSAGE IDLE DISAGREE.(<P>PERFORMED FIM TASK TREE 71-05 FAULT TREE 846. RAN ENGINE BOTH ENGINES AND NO FAULTS NOTED AT THIS TIME. OPS CHECK NORMAL. NO FLIGHT IDLE IDLE MESSAGE AT SDR UIEA2019050604140Window · defectiveLEFT SIDE WINDOW EICAS (<P>REF LOG PAGE 1024257 ITEM 02: NO MESSAGE PRESENT AT THIS GROUND TIME. C/W BITE CHECK OF BOTH CONTROLLERS. NO FAULTS NOTED. LEFT SIDE WINDOW HEAT OPS GOOD AT THIS TIME REF FIM 30-41-00 FT 804. </P><P>REF LOG PAGE 1024259 ITEM M7: TRANSDR UIEA2019050504136Warning System · false activationLEFT SIDE WINDOW CAUTION MESSAGE IN FLIGHT(<P>PERFORMED BITE CHECK IAW FIM 30-41 F/T 804 OPS CHECK GOOD</P>)SDR UIEA2019050404127Actuator · malfunctionedLEFT PACK EXHAUST DOOR DOES NOT OPEN(<P>REMOVED AND REPLACED EXHAUST DOOR ACTUATOR IAW AMM 21-53-04 OPS CHECK NORMAL</P>)SDR UIEA2019042904071Idg · malfunctionedEICAS MSG "RT GEN DRIVE".(<P>RT GENERATOR DEFERRED PER MEL 24-11-01, REF MDDR 110882.</P><P>REMOVED AND REPLACED RT IDG IAW AMM 24-11-01 OPS AND LEAK CHECK REQUIRED. OPS AND LEAKED CHECKED OK ON ENG RUN REF AMM 71-00-001. THIS CLOSES MDDR 110882. PLACARD REMOVSDR UIEA2019042533931Controller · failedL SIDE WINDOW" EICAS MESSAGE 2 HOURS INTO FLIGHT. QRH CHECKLIST CYCLES WINDOW HEAT SWITCH. EICAS MESSAGE EXTINGUISHED. L2 WINDOW HEAT INOP.(<P>PERFORMED FLIGHT COMPARTMENT WINDOW ANTI ICE TEST PER AMM 30-41-00. OPS CHECK GOOD. T/S PER WDM 30-41-12. PERFORMED CSDR UIEA2019041803902Control Unit · inoperativeLEFT SIDE WINDOW EICAS MSG. REMOVED AND REPLACED THE LT SIDE WINDOW HEAT CONTROL UNIT IAW AMM 30-41-01. OPS CHECKED GOOD.SDR UIEA2019041983904Filter · unknownR ENG FUEL FILT EICAS MESSAGE INTERMITTENT(<P>REMOVED AND REPLACED RH ENGINE FUEL FILTER IAW B767 AMM 73-11-03. PERFORMED LEAK CHECK AND WET MOTOR IAW AMM 71-00-00. OPS CHECK GOOD.</P>)SDR UIEA2019041653873Heater · inoperativeL-2 WINDOW HEAT INOP.(<P>TRANSFERRED TO MDDR #110216.<BR /></P><P>LP 1015670 - M6: PER WDM 30-41-12 SHEET 1-2, REMOVED CONNECTOR D5872P. MEASURED VOLTAGE B/W PINS 2&1 SHOWS 2.3 V AC. WHEN THE CONNECTOR WAS CONNECTED BACK THE INOP LIGHT EXTINGUISHES. MCC NOTIFISDR UIEA2019041203861Connector · dirtyL2 WINDOW HEAT INOP. FOUND LOOSE CONNECTION AT C/P D5872P. CLEANED AND SECURED REF WDM 30-41-02. PERFORMED OPS TEST IAW AMM 30-41-00-715-001, OPS TEST GOOD.SDR UIEA2019041103846Warning Message · false activationL SIDE WINDOW ANNUNCIATED IN FLIGHT. (<P>PERFORMED OPERATIONAL TEST I.A.W BITE TEST IN WINDOW HEAT CONTROL UNIT. FOUND GOOD I.A.W AMM 30-41-00.</P>)SDR UIEA2019040803824Warning Light · false activationRH WINDOW HEAT INOP. PERFORMED WINDOW DE-ICE OPS TEST REF AMM 30-41-00, OPS CKD GOOD. ALSO PERFORMED FIM 30-41 FT 804 & 805. NO DEFECTS, OPS CKD GOOD.SDR UIEA2019040873821Anti-Ice System · failedR/H WINDOW HEAT INOP(<P>PERFORMED WINDOW DE-ICE TEST I.A.W. AMM 30-41-00 AND BITE TEST OF R/H FWD AND R/H SIDE WINDOWS IAW AMM FIM 30-41 F/T 804. NO DEFECTS NOTED, OPS CHECK GOOD.</P>)SDR UIEA2019040543774Window · failedL-3 WINDOW HEAT INOP. PERFORMED BITE CHECK OF RIGHT FORWARD/ LEFT SIDE WINDOW HEAT CONTROL UNIT AND FOUND IT TO BE FAULTING 'L3 WINDOW SENSOR' REF AMM 30-41-01. T/S PER FIM TASK 30-41 FAULT. MAIN AND SPARE SENSE OHMED GOOD @ 293.7. CHECKED J9-J12 AT L3 WINDOSDR UIEA2019040103747Duct · tornTWO AIR COOLING DUCTS TORN ON APU.(<P>R/R BOTH AIR DUCTS COOLING DUCTS IAW AMM 49-51-00. NO LEAKS NOTED.</P>)SDR UIEA2019040103749Window · damagedLH ## WINDOW HAS BUBBLES.(<P>R/R LH #3 WINDOW IAW AMM 56-11-10. WINDOW HEAT TEST OK IAW AMM 30-41-00.</P>)SDR UIEA2019032103598Safety Equip · missingEMERGENCY GLOVES MISSING(<P>INSTALLED FIRE GLOVES PER LOPA FT 25-EEL REV 11.<BR /></P>)
Back to N1427A