N144UP

Service difficulty reports · 292

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N144UP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA2026080475424Skin · gougedMAJOR REPAIR, RT WING SLAT NR 1 HAS A GOUGE AND CRACK DAMAGE AT LOWER SKIN, OTBD SIDE. ACCOMPLISHED REPAIR IAW EO-98059-REQ1 AND VT-MAE EA 300-5742-27-A4556, REV -.Jul 2, 2026 · N144UP · Airbus A300F4622R · Leading Edge DevicesSDR IPXA2026061568089Longeron · crackedNR 1 AFT LWR PYLON FAIRING LONGERONS CRACKED UNDER GUSSET PLATE. INSTALLED LONGERON SPLICE DOUBLERS, 2EA IAW SRM 51-40-21-001.Jun 14, 2026 · N144UP · Airbus A300F4622R · Nacelle/Pylon, Longeron/StringerSDR IPXA2026060456403Mount · damagedNR 1 ENGINE, AFT MOTOR ATTACH FITTING HAS CORROSION AND PITTING ON MATTING SURFACE ALL RII STEPS C/W REF GMM CH4. WITNESSED INSTALL AND VERIFIED CRITICAL TORQUE STEPS OK FOR INSTALL.Apr 17, 2026 · N144UP · Airbus A300F4622R · Engine Mount SectionSDR IPXA2026031958584Indicator · inoperativeWARNING SYSTEM ARMED LIGHT WOULD NOT ACTIVATE WITH SLIDE ARMED ON L1 DOOR LIGHT ON CREW DEFERRAL REF T3F18E008H0VJ AND AUTH CODE 2872636Mar 19, 2026 · N144UP · Airbus A300F4622R · Door Warning SystemSDR IPXA2025120197155Light · inoperativeFIRST OFFIER`S OVERHEAD/EMERGENCY LIGHT (DIM SETTING) INOPERATIVE. RE-LAPPED FO`S EMERGGENCY OVERHEAD DIM LIGHT IAW AMM 33-50-00 OPS CHECKED GOOD.Nov 29, 2025 · N144UP · Airbus A300F4622R · Emergency LightingSDR IPXA2025092633383Lock · lack of lubeATB, CABIN DOOR UNLOCK MESSAGE AT 12500 WARNING AT 23000 DOOR UNLOCK OFF AT 7000 FT HANDLE SHOWED SMALL MOVEMENT PRESSURE WAS NORMAL AT GATE HANDLE VISUALLY SHOWS UNLOCKED ACCOMPLISHED RIG AND ADJUSTMENT OF FWD DOOR REF 52-10-20-501. FWD DOOR WAS WITHIN RIG. NSep 25, 2025 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2025092533383Handle · out of positionATB, CABIN DOOR UNLOCK MESSAGE AT 12500 WARNING AT 23000 DOOR UNLOCK OFF AT 7000 FT HANDLE SHOWED SMALL MOVEMENT PRESSURE WAS NORMAL AT GATE HANDLE VISUALLY SHOWS UNLOCKEDSep 25, 2025 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2025072496591Indicator · inoperativeON PREFLIGHT FOUND L1 DOOR RED WARNING LIGHT NOT ILUMINATING WHEN TESTED. RESET AUTONOMOUS POWER SUPPLY AND PERFORMED TEST OF EMERGENCY ESCAPE SLIDE RELEASE WARNGING SYSTEM IAW AMM 52-73-00. TEST PASS. THIS CLEARS AUTH 2851768. DMP REVERSED PLACARD REMOVED.Jul 24, 2025 · N144UP · Airbus A300F4622R · Door Warning SystemSDR IPXA2024040309466Union · leakingLOSS OF GREEN SYSTEM HYDRAULICS IN FLIGHT. PERFORMED ECAM & CHECKLISTS REMOVED AND REPLACED EXTRUDED €ŒO€? RING AND UNION ON HYDRAULIC. KRUEGER MANIFOLD 1149 REF: IPC 27-88-03-04 ITEMS 140 AND 150. I/A/W A300 AMM 27-88-14. PERFORMED BLEEDING OF GREEN. HYDRAUApr 3, 2024 · N144UP · Airbus A300F4622R · Hydraulic System, MainSDR IPXA2024012452353Web · crackedWEB AT FR 10 RH HAS A CRACK. INSTALLED NEW WEB IAW SRM 51-40-21 AT FR10 INSIDE FED ACCESSORY COMPT. R/H SIDE, MAIN DECK FLOOR STRUCTURE. APPLIED ALODINE AND PRIME IAW SRM 51-21-10 AND TOP COAT IAW SRM 51-75-10. AUDIT COMPLETE. REVIEWEDJan 16, 2024 · N144UP · Airbus A300F4622R · Fuselage Miscellaneous StructureSDR IPXA2024011752353Web · cracked*** SDR FILED OPEN *** FAULT- AA INSP - WEB AT FR 10 RH HAS A CRACK 1) REMOVED CRACKED WEB AT FR 10 RH IAW SRM 51-40-21. JL 07586 1/17/24Jan 16, 2024 · N144UP · Airbus A300F4622R · Fuselage Miscellaneous StructureSDR IPXA2024011726100Skin Panel · damagedFWD CARGO COMPT. FR 20 R/H SIDE HAS UPPER SKIN DAMAGE CEILING PANEL 132 NC. INSTALLED SKIN PANEL IAW SREO A300-2550-21666 JL 07586.Jan 13, 2024 · N144UP · Airbus A300F4622R · Fuselage Main, Plate/SkinSDR IPXA2024011725517Doubler · crackedNR 1 ENGINE PYLON INBOARD EDGING ANGLE CRACK - PERFORM PERMANENT REPAIR FABRICATED DOUBLER IAW SRM 54-56-10. INSTALLED DOUBLER IAW SRM 54-56-10 CONFIG-1 PAGE 203. AT #1 ENG PYLON.Jan 13, 2024 · N144UP · Airbus A300F4622R · Nacelle/Pylon, Main FrameSDR IPXA2024012411460Floorbeam · crackedFOUND STRUCTURAL ANGLE LOCATED INSIDE FWD ACCESSORY COMPT R/H SIDE, MAIN DECK FLOOR STRUCTURE THAT IS CRACKED. ATTACHED TO FLOOR BEAM DIRECTLY ABOVE ENTRY OPENING. AA006 INSTALLED NEW ANGLE IAW SRM 51-40-21 AT LOCATED INSIDE FWD ACCESSORY COMPT. RH SIDE, MAIN Jan 6, 2024 · N144UP · Airbus A300F4622R · Fuselage Main, Floor BeamSDR IPXA2024011307457Doubler · crackedSKIN DOUBLER ON R/H WING AT PANEL 611KT HAS A REPAIR DOUBLER THAT IS CRACKED. DOT 60-003. INSTALLED REPLACEMENT DOUBLER IAW SRM 51-40-21.Jan 6, 2024 · N144UP · Airbus A300F4622R · Wing, Plate/SkinSDR IPXA2023112883286Unknown · unknownOOS - AFT TRANSFER FUEL NOT AVAILABLE MSG RECIEVED VIA ECAM ON CLIMBOUTTRIM ISO VALVE REMAINED ON ** OII 2 ** (LINKED ALERT T3F18E003F21D) CENTER TANK HARNESS, PROBES AND COMPENSATOR REPLACED ON ALERT BARCODE TEF18E003F21D PER AMM 28-42-34 AND 28-42-31. TESTSNov 28, 2023 · N144UP · Airbus A300F4622R · Aircraft Fuel Distribution SystemSDR IPXA2023101834213Unknown · unknownLEFT FWD CABIN NOT CLOSED INFLIGHT. WE VISUALLY CHECKED AND DOOR NOT LOCKED. RAN CHECKLIST (INDICATION UNLOCKED)IN ACCORDANCE WITH AOM PROCEDURES CHECKED OPERATION OF SWITCHES 43WS & 7WS, ACCOMPLISHED ADJUSTMENT OF SWITCH 7WS W/REF TO M/M 52-71-00. OPS CHECK GOct 18, 2023 · N144UP · Airbus A300F4622R · Door Warning SystemSDR IPXA2023061393425Safety Clip · inoperativeINSPECTION TYPE:NAEXIT DOOR EMERGENCY SLIDE SAFETY PIN NEEDS A RED STREAMERRE-INSTALLED THE EXIT DOOR EMERGENCY SLIDE SAFETY PIN. OPS CHECKS GOOD IAW AMM 52-10-30-0501Jun 12, 2023 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2023041992924Unknown · unknownINSPECTION TYPE:NAON CLIMB OUT "L FWD CABIN NOT CLOSED" ECAM WARNING. CABIN ALT AND DIFF PRESS IN NORMAL RANGE.C/W L FWD CABIN DOOR WARNING OPS TEST PER AMM 52-70-00 PB 501. OPS CHECK GOOD. NO 30 DAY HISTORY.Apr 19, 2023 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2023031791937Door · unknownINSPECTION TYPE:N/ADURNG CLIMB "L FWD CABIN" EICAS DISPLAYED. PRESSUREIZATION WAS NORMAL, FLOOWED QRH PROCEDURE AND PUSHED DOOR CONTROL HANDLE DOWN MOVING IT SLIGHTLY, THIS EXTINUISHED FWD CABIN AND RETURNED TO NORMAL DOOR CLOSED AND LOCKEDL/H FWD CABIN DOOR LMar 16, 2023 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2023021791085Slide · inoperativePLASTIC SLIDING COVER THAT GUARDS MAIN ENTRY DOOR SLIDE ARMING LEVER APPEARS BROKEN. DEFERRED BY NEF 25-70-52-10-04 M803016 ASSIGNED PLACARD INSTALLED. REPLACED COVER PER MM 52-10-13-0401. M803016 CLEARED ESR: IPC 52-11-13-07AFeb 17, 2023 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2022112988544Thrust Reverser · faultedDIVERSION, AT FL300 RECEIVED A #2 T/R UNLOCKED INDICATION. AT FIRST IT WAS A STEADY INDICATION DURING DESCENT THE LIGHT WENT OUT FOR AWHILE THEN BECAME INTERMITANT UNTIL LANDING. COMPLIED WITH ECAM. NR 2 T/T STOWED AND LOCKED. TROUBLESHOT IAW TSM 78-31-40Nov 29, 2022 · N144UP · Airbus A300F4622R · Engine Thrust ReverserSDR IPXA2022111588139Warning Horn · no testWARNING HORN DID NOT BUZZ WHEN TESTING SLIDE. C/W VERIFICATION OF WARNING HORN WORKING PER MM 52 73 12 0401.Nov 14, 2022 · N144UP · Airbus A300F4622R · Emergency EquipmentSDR IPXA2021111776084A/C Pack · odorINSPECTION TYPE:N/ASMELL FROM PACK 1--SMELLS LIKE BURNING DUST OR WAM FRENCH FRIES. SMELL WENT AWAY TURNING PACK 1 OFF (NOTE IT IS NOT A DIRTY SOCKS SMELL)RUN PACK 1 THROUGH ALL TEMPERATURE RANGES IAW A300 AMM 21-51-00 NO FURTHER SMELLS NOTEDNov 17, 2021 · N144UP · Airbus A300F4622R · Cabin Cooling SystemSDR IPXA2021092474219Warning Light · inoperativeINSPECTION TYPE:N/AWARNING LIGHT IN SLIDE ARMING PANEL INOP. REF MEL 52-73-01-1 DMI M757558 APPLIED PLACARD INSTALLED.T/S'ING C/O USING ASM 52-73-00. CONFIRMED BROKEN WIRE FROM TERMINAL @ SWITCH LT 7WN WARN. ACCOMPLISHED REPAIR PER ESPM 20-48-20-0201. NORMAL CSep 23, 2021 · N144UP · Airbus A300F4622R · Passenger/Crew DoorsSDR IPXA2021091573945Battery · dischargedAT 2305 Z ECAM - SMOKE, DSC AGENT 2- DISCHARGED, FOUND #1 MAIN BATT 0 VOLTS CAUSING DISCH 2 LIGHT TO COME ON, REF ASM 24-50 SCH 3 RESET C/B 27PE, PERFORMED BATTERIES DC GENERATION ADJ. TEST IAW AMM 24-31-00 PB 501. OPS CHECK GOOD. ALL BATT VOLTAGES NORMAL, PESep 14, 2021 · N144UP · Airbus A300F4622R · Battery/Charger SystemSDR IPXA2021080572499Cover · brokenINSPECTION TYPE:N/A** SUPPLEMENTAL SDR** ENTRY DOOR HANDLE NEEDS TO BE RIGGED. SLIDE ARMING COVER IS BROKEN AND SHARP.TRANSFERRED TO NRC 212031 AND NRCX 212032.REMOVED AND REPLACED SLIDING ARM COVER IAW AMM 52-10-13.Aug 5, 2021 · N144UP · Airbus A300F4622R · Emergency EquipmentSDR IPXA2021080372262Battery · no testINSPECTION TYPE:A300BAT-2 FAIL LIGHT DURING ASPSU BITE TESTREMOVED AND REPLACED INBOARD BATTERY IAW A300-600 AMM 52-73-18-0401 AND AIPC 52-73-18-01-010.Jul 25, 2021 · N144UP · Airbus A300F4622R · Door Warning SystemSDR IPXA2021080392261Battery · no testINSPECTION TYPE:A300BAT-2 FAIL LIGHT DURING ASPSU BITE TESTREMOVED AND REPLACED OUTBOARD BATTERY IAW A300-600 AMM 52-73-18-0401 AND AIPC 52-73-18-01-010.Jul 25, 2021 · N144UP · Airbus A300F4622R · Door Warning SystemSDR IPXA2021080272292Floor Panel · damagedINSPECTION TYPE:A300PNL 221VF DAMAGED.FABBED IAW SREO A300-5320-40552-B.Jul 22, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072572054Floor Panel · damagedINSPECTION TYPE:A300PNL 232KH BROKEN.FABBED IAW SREO A300-5320-40552-B.Jul 13, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072872220Strap · damagedINSPECTION TYPE:A300WHILE REMOVING DAMAGED RUDDER CAP,FOUND UNDERLINING STRUCTURE I/B AND O/B T/E STRAP DAMAGED FROM LIGHTENING STRIKE.REPAIRED PER A300 SRM 55-41-21.Jul 12, 2021 · N144UP · Airbus A300F4622R · Rudder StructureSDR IPXA2021071671749Floor Panel · damagedINSPECTION TYPE:A300FWD CABIN FLOOR PANEL 23IVG HAS DAMAGE AT 2 LOCATIONS.COMPLIED WITH SREO A300-5320-42722-F.Jul 10, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072872198Hinge Bracket · crackedINSPECTION TYPE:A300LT WING BELOW #3 SPOILER I/B HINGE ARM FIXED T/E END RIB INTER-COSTAL FWD BRACKET CRACKED.REMOVED,FABRICATED,AND INSTALLED IAW SRM 51-40-44 AND 51-40-21.Jul 7, 2021 · N144UP · Airbus A300F4622R · SpoilersSDR IPXA2021072071888Rib · crackedINSPECTION TYPE:A300LT WING BELOW #3 SPOILER I/B HINGE ARM WING FIXED T/E END RIB INTER-COSTALWEB CRACKED.REMOVED,FABRICATED,AND INSTALLED IAW SRM 51-40-21.Jul 7, 2021 · N144UP · Airbus A300F4622R · SpoilersSDR IPXA2021071541679Intercostal · crackedINSPECTION TYPE:A300LT WING BELOW #4 SPOILER O/B HINGE ARM WING FIXED T/E END RIB INTER-COSTAL WEB CRACKED.REMOVED,FABRICATED,AND INSTALLED IAW SRM 51-40-21.Jul 7, 2021 · N144UP · Airbus A300F4622R · Wing Miscellaneous StructureSDR IPXA2021071871799Floor Panel · damagedINSPECTION TYPE:SEGPANEL #242BN HAS COMPOSITE DAMAGECOMPLIED WITH SREO A300-5320-42722-FJul 3, 2021 · N144UP · Airbus A300F4622R · Fuselage Miscellaneous StructureSDR IPXA2021071371631Floor Panel · brokenINSPECTION TYPE:A300MAIN CARGO COMPT. FLOOR PANEL 241NN, UPPER LH CORNER HAS HONEYCOMB BROKEN.REPAIRED IAW A300-5320-42722-F.Jul 3, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021071371630Floor Panel · brokenINSPECTION TYPE:A300MAIN CARGO COMPT. FLOOR PANEL Z41RM, UPPER RH CORNER HAS HONEYCOMB BROKEN.REPAIRED IAW SREO A300-5320-42722-F.Jul 3, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021070371241Floorboard · damagedINSPECTION TYPE:A300AFT CARGO FLOOR PANEL 152SF MISSING PIECE OF HONEYCOMBCOMPLIED WITH SREO A300-5320-42722-FJul 3, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021070371240Floor Panel · damagedINSPECTION TYPE:A300FWD CARGO FLOOR PANEL 132RG HAS DAMAGE AT THE CORNERCOMPLIED WITH SREO A3005320-42722-FJul 3, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021071571731Floor Panel · damagedINSPECTION TYPE:A300MDCC FLOOR PANEL 251ZG BROKEN. FABBED IAW SREO A300-5320-40552-B.Jul 2, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021071571718Floor Panel · damagedINSPECTION TYPE:A300PNL 251PG BROKENFABBED IAW SREO A300-5320-40552-B.Jul 2, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021071571717Floor Panel · damagedINSPECTION TYPE:A300MDCC FLOOR PNL 251UJ BROKENFABBED IAW SREO A300-5320-40552-B.Jul 2, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021071571716Floor Panel · damagedINSPECTION TYPE:A300PN 251BN BROKENFABBED IAW SREO A300-5320-40552-B.Jul 2, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021073072272Bracket · crackedINSPECTION TYPE:A300EXTERNAL FUSELAGE BET FR45 & FR46 LH SIDE AIRON PANEL 143CL AFT STRUCTURE SUPPORT BRACKET CRACKED.REMOVED AND REPLACED IAW A300 SRM 51-40-21.Jul 1, 2021 · N144UP · Airbus A300F4622R · Fuselage Main, Attach FittingsSDR IPXA2021072572056Floor Panel · damagedINSPECTION TYPE:A300PNL 262BH CRACKED.FABBED IAW SREO A300-5320-40552-B.Jul 1, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072572053Floor Panel · damagedINSPECTION TYPE:A300PNL 262DM CRACKED.FABBED IAW SREO A300-5320-40552-B.Jul 1, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072572052Floor Panel · damagedINSPECTION TYPE:A300PNL 261BM CRACKED.FABBED IAW SREO A300-5320-40552-B.Jul 1, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor PanelSDR IPXA2021072572051Floor Panel · damagedINSPECTION TYPE:A300PNL 231MJ BROKEN.FABBED IAW SREO A300-5320-40552-B.Jul 1, 2021 · N144UP · Airbus A300F4622R · Fuselage Floor Panel
Back to N144UP