What was found
OOS - AFT TRANSFER FUEL NOT AVAILABLE MSG RECIEVED VIA ECAM ON CLIMBOUTTRIM ISO VALVE REMAINED ON ** OII 2 ** (LINKED ALERT T3F18E003F21D) CENTER TANK HARNESS, PROBES AND COMPENSATOR REPLACED ON ALERT BARCODE TEF18E003F21D PER AMM 28-42-34 AND 28-42-31. TESTS OF CENTER TANK HARNESS/PROBE INSTALLATION VERIFICATION PASS PER AMM 28-42-00. FQIS BITE TEST PASSES PER AMM 28-42-00 AND CGCC OPS CHECKS GOOD PER AMM 31-46-00. SEALANT STILL WET AT THIS TIME. LEAK CHECK OF CENTER TANK HARNESS CONNECTORS REQUIRED. PLACARD REMOVED.