N155UW
Service difficulty reports · 111
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N155UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N155UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014082500014Bottle · low pressureR4 DOOR ASSIST BOTTLE NEEDS SERVICED. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001A.SDR USAA2014080400014Bottle · low pressureFLIGHT ATTENDANT ADVISED CHECK DOOR PRESS ON DOOR 4R. SERVICED DOOR ASSIST BOTTLE & MSG CLEARED. OK FOR SERVICE.SDR USAA2014071400006Lens · brokenTHE EMER LIGHT WHITE LENS AT SEAT 3C LENS BROKEN OFF. REPLACED LIGHT AT SEAT 3C EMER LIGHTING. OPERATIONS CHECKED GOOD.SDR USAA2014070800004Bottle · low pressureCREW RECEIVED A CHECK DOOR PRESS ON DOOR 4R MSG ON CIDS PANEL. SERVICED DOOR ASSIST BOTTLE AS REQUIRED. DOOR 4R CHECKED OK IAW TASK AMM 52-22-00-614-022-A.SDR USAA2014062600007Bottle · low pressureTHE 4R DOOR ASSIST BOTTLE HAS LOW PRESS. SERVICED 4R DOOR ASSIST BOTTLE. CHECKED OK IAW AMM 52-22-00-614-002A.SDR USAA2014051300004Filter · cloggedCREW REPORTED A SMOKE LAVATORY DETECTOR INOPERATIVE. FOUND LAVATORY L SMOKE DETECTOR FILTER CLOGGED, CLEANED FILTER. TROUBLE SHOT SYS IAW TSM 26-17-00-810-815A. SYSTEM OPERATIONS CHECKED GOOD IAW AMM 26-17-00-710-001A.SDR USAA2014050600003Unknown · odorFLIGHT ATTENDANT REPORTED A CABIN ODOR. PERFORMED JOB CARD 26L00021001 TROUBLESHOOT CABIN AIR QUALITY & PERFORMED ENG RUN. ISOLATED THE PACKS & BLEED SOURCES FOR EXTENDED PERIOD OF TIME. NO ODORS DETECTED REGARDLESS OF BLEED SOURCE, PACK OR TEMPERATURE SELESDR USAA2014032500001Bottle · low pressureCIDS PANEL REPORT SLIDE 4R PRESS LOW. SERVICED 4R DOOR ASSIST BOTTLE IAW AMM 52-22-00-614. FAULT CLEARED, OK FOR SERVICE.SDR USAA2014030700006Filter · dirtyCREW REPORTED A CLASS II MX STATUS MSG SMOKE. MX FOUND ALL LAVATORY SMOKE DETECTOR FILTERS DIRTY. REPLACED FILTERS, OPERATIONS CHECK OF LAVATORY SMOKE DETECTION SYS OK IAW AMM 26-17-15-100-003-A.SDR USAA2014022800003Bottle · low pressureREPORTED THE AFT 4R SLIDE DOOR ASSIST PRESS LOW. SERVICED ASSIST DOOR BOTTLE FOR AFT 4R DOOR IAW 52-22-00-614-002A, OK FOR SERVICE.SDR USAA2014012700041Light · damagedMAINTENANCE REPORTED THE EMERGENCY EXIT LIGHT AT SEAT 8C DAMAGED. R & R LIGHT ASSEMBLY, OPERATIONS CHECKED GOOD.