N156AN
Service difficulty reports · 173
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N156AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N156AN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201806065002Bottle · low pressureR3 DOOR DAMPER PRESSURE IN THE RED BAND. MAINTENANCE SERVICED THE R3 DOOR DAMPER CYLINDER IAW AMM 52-22-00, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA20180605001Cylinder · low pressureR1 DOOR EMERGENCY ACCUMULATOR CYLINDER PRESSURE READ 1650 PSI, AT 81 DEGREES F. SERVICED THE R1 DOOR TO PROPER PRESSURE IAW AMM 52-10-00.SDR AALA20180313014Bottle · low pressureEMERGENCY DOOR PRESSURE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR AALA201803139021Valve · faultyLANDING GEAR FAILED TO EXTEND, DOORS FAILED TO OPEN. THIS CONDITION LASTED FOR 30 SECONDS. CYCLED LANDING GEAR HANDLE AND LANDING GEAR EXTENDED IMMEDIATELY, THREE RED LAMPS REMAINED ILLUMINATED DURING THE FIRST ATTEMPT). INSTALLED SERVICEABLE LANDING GEAR SAFSDR AALA201801189021Battery · inoperativeFOUND FAULT MESSAGE BAT/EPSU 15WL ON MCDU WHEN PERFORMING EMERGENCY BATTERY OPERATIONS TEST. REPLACED EMERGENCY BATTERY AT DOOR 2L PER AMM 33-51-38.SDR AALA20170903010Cylinder · low pressureR3 DOOR EXIT ASSIST CYLINDER PRESSURE WAS LOW, IN YELLOW BAND. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA20170829002Actuator · low pressureAIRCRAFT WAS NOT GROUNDED. R3 DOOR DAMPER PRESSURE IN LOWER RED ZONE. SERVICED R3 DAMPER (ACTUATOR) PRESSURE TO GREEN ZONE PER AMM 52-22-00.SDR AALA201708109010Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. R3 DOOR ASSIST BOTTLE PRESSURE BELOW LIMITS. SERVICED R3 DOOR ASSIST BOTTLE PER AMM 52-22-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20170712001Cylinder · low pressureR3 DOOR EMERGENCY EXIT DAMPER PRESSURE IN RED ZONE. SERVICE R3 DOOR CYLINDER IAW AMM 52-22-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201706069008Bottle · low pressureR3 EMERGENCY EXIT DOOR BOTTLE PRESSURE IS LOW. SERVICED THE BOTTLE IAW AMM 52-22-00.SDR AALA20170605001Actuator · low pressureR-3 EMERGENCY EXIT DOOR, DISCHARGE BOTTLE PRESSURE IS LOW. SERVICED ACTUATOR TO TOP OF GREEN BAND IAW AMM 52-22-00.SDR AALA201705299005Bottle · low pressureR3 DOOR DAMPER PRESSURE LOW. SERVICED R3 DOOR DAMPER IAW AMM 52-22-00.SDR AALA201705089022Bottle · low pressureR3 DOOR DAMPER BELOW LIMIT. SERVICED R3 DOOR DAMPER PER AMM 52-10-00.SDR AALA201705019031Damper · low pressureFOUND THE R3 DOOR DAMPER WITH PRESSURE LOW. SERVICED THE R3 DOOR DAMPER IAW AMM 52-22-00.SDR AALA201704239005Damper · low pressureR3 DOOR DAMPER PRESSURE LOW. SERVICED R3 DOOR DAMPER IAW AMM 52-22-00.SDR AALA20170319002Battery · no testEMARGENCY EXIT LIGHT BATTERY 14WL FAILED TEST. REPLACED EMERGENCY EXIT LIGHT BATTERY IAW AMM 33-51-38.SDR AALA20170319001Bottle · low pressureEMERGENCY EXIT R3 DOOR ASSIST BOTTLE IS BELOW LIMITS. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-22-00.SDR AALA20170118003Cylinder · low pressureAIRCRAFT NOT GROUNDED. R3 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-22-00. OPERATIONAL CHECK GOOD.SDR AALA20170104002Battery · dischargedAIRCRAFT NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT 13WL FAILED PS2 CHECK. REMOVED AND REPLACED EPSU BATTERY IAW AMM 33-51-38-000-002. OPERATIONAL CHECK GOOD.SDR AALA20161213019Oven · contaminatedAIRCRAFT WAS NOT GROUNDED. DURING TAXI OUT A FLIGHT ATTENDANT REPORT SMOKE AND FIRE IN THE FIRST CLASS NR 1 OVEN. MAINTENANCE FOUND A PIECE OF PAPER TAPED TO THE BACK OF THE OVEN RACK. REMOVED AND REPLACED OVEN IAW AMM 25-35-19. OPERATIONAL CHECK GOOD.SDR AALA20161208008Oven · fireFORWARD GALLEY OVEN FIRE. REMOVED AND REPLACED THE NR 1 OVEN IAW AMM 25-35-19. OPS CHECKED GOOD.SDR AALA20161115015Cylinder · low pressureAIRCRAFT NOT GROUNDED. R3 EMERGENCY EXIT DOOR DAMPER CYLINDER PRESSURE LOW AT 100 PSI. SERVICED CYLINDER IAW AMM 52-22-00. OPERATIONAL CHECK GOOD.SDR AALA20161013002Battery Pack · inoperativeL2 DOOR EMERGENCY LIGHT BATTERY IS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-38. OPERATIONAL CHECKED GOOD.
Back to N156AN