What was found
LANDING GEAR FAILED TO EXTEND, DOORS FAILED TO OPEN. THIS CONDITION LASTED FOR 30 SECONDS. CYCLED LANDING GEAR HANDLE AND LANDING GEAR EXTENDED IMMEDIATELY, THREE RED LAMPS REMAINED ILLUMINATED DURING THE FIRST ATTEMPT). INSTALLED SERVICEABLE LANDING GEAR SAFETY VALVE PER AMM 32-31-17.