N164UP
Service difficulty reports · 137
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N164UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N164UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2175121Power Supply · inoperativeINSPECTION TYPE: 3C, EMERGENCY EXIT LIGHT P/B SWITCH INTEGRANULAR LAMO AT CREW DOOR DOES NOT LIGHT WHEN PRESSED. R & R EMERGENCY POWER SUPPLY IAW AMM 33-51-14-04.SDR IPXA12174996Floor Panel · crackedINSPECTION TYPE:3C, MAIN DECK CARGO FLOOR PANEL CRACKED AND DELAMINATED. REPAIRED FLOOR PANEL 231MJ IAW EO A300-5320-42721-B, PAR 6A.SDR IPXA12174995Floor Panel · crackedINSPECTION TYPE:3C, FLOOR PANEL 231MJ CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175023Structure · dentedINSPECTION TYPE:1C, RT MID FLAP BULLNOSE OTBD OF NR 3 FLAPTRACK SKIN IS DENTED. ACCOMPLISHED REPAIR ON RT MID FLAP BULLNOSE SKIN OTBD OF NR 3 FLAP TRACK IAW SRM 57-50-00, FIG 208, REV 21.SDR IPXA12175010Structure · chafedINSPECTION TYPE: 1C, RT MID FLAP OTBD BULLNOSE CHAFED. ACCOMPLISHED REPAIR ON RT MID FLAP OTBD BULLNOSE IAW SRM 57-50-00, FIG 208, REV21 AND EO A300-5720-45980-A.SDR IPXA12174533Skin · damagedFWD LWR CARGO DOOR OPENING FUSELAGE SKIN DAMAGED FR 20A, S28R. REPAIRED IAW EO A300-5330-47760-B.SDR IPXA11168941Light · inoperativeLAV AUX / MIRROR LIGHT INOPERATIVE. RELAMPED AND TESTED GOOD IAW MM 33-51-21-04.SDR IPXA1167752Slide · unserviceableCREW ENTRANCE DOOR WILL NOT ARM. REMOVED MAIN CABIN DOOR SLIDE IAW DMP 52-11-01-3 AND MEL 52-11-01-3.SDR IPXA11166764Skin · damagedRT WING OTBD CTR FLAP LOWER SKIN DAMAGED AND INNER STRINGER DAMAGED. REPAIRED IAW EO A300-5750-42754-A.SDR IPXA11166693Sleeve · damagedUPON ARRIVAL, MX INSP DISCOVERED RT ENG OTBD T/R SLEEVE PARTIAL SEPARATION FROM ACFT. APPX 1 FT X 7 FT SECTION OF T/R SLEEVE MISSING. DEBRIEF FROM FLT CREW NOTED LANDING RW 35L. TOWER AND CFR WAS NOTIFIED AND RWY INSP RECOVERED SEVERAL SMALL SECTIONS OF SAMESDR IPXA1166693Sleeve · separatedUPON ARRIVAL, MX INSP DISCOVERED RT ENG OTBD THRUST REVERSER SLEEVE PARTIAL SEPARATION FROM ACFT. APPX 1 FT X 7 FT SECTION OF T/R SLEEVE MISSING. DEBRIEF FROM FLT CREW NOTED LANDING SDF RW 35L. TOWER AND CFR WAS NOTIFIED AND RWY INSP RECOVERED SEVERAL SMALLSDR IPXA10163657Seat Track · wornINSPECTION TYPE:SV, DEFERRED ITEM D-435625: MAIN DECK SEAT TRACK DAMAGE FR 19 Y=1959. REMOVED DAMAGE, AND SPLICED IN NEW SEAT TRACK IAW STA-EA 300-5310-01-A2791 AND EO A300-5310-40580-A.SDR IPXA10159999Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOOR PANEL 231LG IS CRACKED AT FASTENER HOLE. FABRICATED FLOORBOARD 231LG IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160020Floorboard · crackedINSPECTION TYPE:5YR, FLOORBOARD 231LJ IS CRACKED AT UPPER SKIN INBD EDGE FABRICATED FLOORBOARD 231LJ IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160017Floor Panel · crackedINSPECTION TYPE:5 YR FLOOR PANEL 231PJ IS DELAMINATED AT FWD CTR AND CRACKED AT AFT INBD CORNER. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. B.SDR IPXA10160016Floor Panel · damagedINSPECTION TYPE:5 YR, BULK CARGO PANEL 161GF REQUIRES REPLACING. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. D.SDR IPXA10159998Floorboard · damagedINSPECTION TYPE:5YR, MAIN CARGO COMPARTMENT FLOOR PANEL 262DM REQUIRES REPLACING IAW EO A300-5320-16407-D. FABRICATED FLOORBOARD 262DM IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10159996Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD 231NJ IS CRACKED AT FWD EDGE FABRICATED FLOORBOARD 231NJ IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160151Floorboard · brokenINSPECTION TYPE:5 YR, MAIN CARGO COMPARTMENT NR 241 NK FLOORBOARD AT FWD CORNER EDGE BROKEN OFF. FABRICATED REPLACEMENT FLOOR PANEL NR241 NK IAW EO 300-5320-16407-D, APPENDIX A AND B.SDR IPXA10160096Stringer · damagedINSPECTION TYPE:5 YR, CORRELATE STRINGER REPAIR IAW SRM 53-10-14, AT FR. 28 BETWEEN STR 49L TO 51L REPAIRED IAW SRM 53-10-14, PARA. 5 AND FIG 208.SDR IPXA10160014Floor Panel · damagedINSPECTION TYPE:5 YR, FLOOR PANEL 131AH IN FWD CARGO REQUIRES REPLACING FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. C.SDR IPXA10159997Floorboard · delaminatedINSPECTION TYPE:5YR, MAIN CARGO COMP FLOOR PANEL 231VG HAS DELAMINATED AREA. FABRICATED FLOORBOARD 231VG IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10159970Floor Panel · brokenINSPECTION TYPE:5 YR, MAIN CARGO COMPARTMENT NR 251UJ FLOOR PANEL AT AFT OTBD CORNER IS BROKEN OFF. FABBED FLOOR PANEL 251UJ IAW UPS EO A300-5320-16407-D, APPX B.SDR IPXA10159968Floorboard · crackedINSPECTION TYPE:5YR, MAIN CARGO COMPARTMENT NR 252 WG FLOORBOARD AT INBD CTR AREA IS CRACKED. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. BSDR IPXA10160145Skin · misrepairedINSPECTION TYPE:5YR, REPAIR SURVEY SEQ 164-W3-02 LOCATED BETWEEN RIBS 13 & 15, STGR 2.6 & 2.8 DOES NOT CORRELATE WITH SRM. LT CTR FLAP. REPAIRED LT CTR FLAP REF STA EA 300-5753-01-A2322 IR AND EO A300-5750-37987-A.SDR IPXA10159957Floorboard · crackedINSPECTION TYPE:5YR, MAIN DECK FLOOR PANEL NR 251DF IS CRACKED. FABRICATED FLOOR PANEL 251DF IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160120Skin · misrepairedINSPECTION TYPE:5 YR, REPAIR SURVEY SEQ 164-W3-01 ON LT WING , INBD FLAP LOWER SURFACE OF T/E DOES NOT CORRELATE WITH SRM REPAIRED IAW EA 300-5750-A2316 REV I/R AND UPS EO A300-5750-37927-A.SDR IPXA10160015Floor Panel · damagedINSPECTION TYPE:5 YR, BULK CARGO FLOOR PANEL 161HF REQUIRES REPLACING FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. D.SDR IPXA10159958Floor Panel · damagedINSPECTION TYPE:5YR, BULK PIT FLOOR PANEL NR 162HF REQUIRES REPLACING IAW EO A300-5100 -16407-D. FABRICATED NEW FLOOR PANEL NR 162HF IAW EO A300-5320-16407-D, APPENDIX D.SDR IPXA99157902Skin · dentedFUSELAGE SKIN DAMAGE AT FRA 85 11 INCHES AFT OF TAIL STAND BALL. REPAIRED IAW EO A300-5330-35274-C AND SRM 53-10-12 FIGURE 208. REFERENCE NRC 354566.SDR IPXA09157565Light · inoperativeINSPECTION TYPE:N/A DOOR SLIDE ARMED WARNING LIGHT DOES NOT ILLUMINATE DURING TEST. DEFERRED M409564 PER MEL 52-73-01-1. C/W SLIDE ARMED LIGHT TEST REF MM 52-73-11-04. WARNING LIGHT AND WARNING TONE BOTH OPERATE NORMAL. THIS CLEARS M409564.SDR IPXA09155153Warning Light · false activationINSPECTION TYPE:N/A WHEN IN RANGE OF SDF, THE CAPTAIN ADVISED FLIGHT CONTROL HE HAD DECLARED AN EMERGENCY WITH SDF ATC DUE TO A THRUST REVERSER UNLOCK LIGHT. REACTIVATED NR 1 T/R PER AMM 78-31-00-09, ACP IDLE ENG RUN OPS TEST OF T/R PER AMM 78-31-00-05 AND SDR UPS08154077Roller · damagedL1 DOOR ROLLER & TRACK DAMAGE. REMOVED & REPLACED FWD ENTRY DOOR SLIDE IAW AMM 20-21-12-00 AND AMM 52-11-11-04SDR UPS08153413Generator · malfunctionedINSPECTION TYPE:N/A ATB - AFTER TAKEOFF NR 1 GEN FAULTED. APU GEN FAULTED ALSO UPON START UP REF LOG PAGE 964332. GPCU SHOWED GEN 1 GCU AT FAULT. REPLACED NR 1 GCU IAW AMM 24-22-12-04. REPLACED GPCU IAW AMM 24-41-11-04. OPS CHECK GOOD. GROUND RAN ENG NR SDR UPS08153141Light · malfunctionedEXIT LIGHT OVER DOOR REMAINS ON IN ALL SWITCH POSITIONS. ECAM SHOWS EXIT ON. PERFORMED ADJUSTMENT TEST OF SUPERNUMARY AREA EMERGENCY LIGHTS PER A300 MM 33-51-00-05. SYSTEM OPS CHECKED GOOD, CONTINUE IN SERVICE.SDR UPS08151396Switch · inoperativeINSPECTION TYPE:N/A ON FINAL APPROACH AT GEAR DOWN, GOT ECAM IND "LG POS DET SYS 2 FAULT". DID QRH PROC AND LANDED UNEVENTFULLY. DEF "LG POS DET SYS 2", PER MEL 32-61-04. PLACARD INSTALLED DEF 366625. REMOVED AND REPLACED LANDING GEAR NORMAL CONTROL MICROSSDR UPS07150047Stringer · puncturedAIRCRAFT SUSTAINED DAMAGE FROM RUNWAY CANS AT SECTION 130 FROM STATION 1817 FR 27-2241 FR 35. A/C HAS BEEN PUNCTURED AT THESE STATIONS. REMOVED DAMAGE PER A300 SRM 53-10-12. REPAIRED DAMAGE STRINGER L AFT OF FR IAW SRM 53-10-14. REPAIRED DAMAGE AREA IAW SR