What was found
UPON ARRIVAL, MX INSP DISCOVERED RT ENG OTBD T/R SLEEVE PARTIAL SEPARATION FROM ACFT. APPX 1 FT X 7 FT SECTION OF T/R SLEEVE MISSING. DEBRIEF FROM FLT CREW NOTED LANDING RW 35L. TOWER AND CFR WAS NOTIFIED AND RWY INSP RECOVERED SEVERAL SMALL SECTIONS OF SAME. REMOVED RT OTBD T/R COWL IAW AMM 71-13-03-04 STEPS 1A & B, 2 AND 3A, B1 THRU 27. INSP PYLON HINGE ATTACH POINTS AND SURROUNDING AREA, NO DAMAGE NOTED. OK TO INSTALL NEW T/R HALF. INSTALLED AND TORQUED RT T/R OTBD HALF IN REF TO MM 71-13-03-04.