N1709A
Service difficulty reports · 455
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019112535949Pin · brokenFO'S O2 MASK PIN ON DOOR BROKEN.(<P>FOUND FO'S O2 MASK SERVICEABLE. RE-ALIGNED DOOR PIN AND STOWED MASK IAW AMM 35-11-51. OPS TEST NORMAL AND LEAK CHECK GOOD.</P>)SDR UIEA2019112215941Warning Message · false activationFIRE/OVERHEAT SYSTEM EICAS ILLUMINATED ON APPROACH. (<P>PERFORMED AFOLTS TEST, NO DEFECT FOUND AT THIS TIME PER FIM 26-10 FAULTS TREE 803.</P>)SDR UIEA2019111205876Circuit Breaker · openON PRE-FLIGHT, L FUEL OVERRIDE CIRCUIT BREAKER OPEN.(<P>RESET L FUEL OVERRIDE PUMP CIRCUIT BREAKER IAW AMM 20-60-05. OPS CHECKED GOOD AT THIS TIME IAW AMM 28-22-00.</P>)SDR UIEA2019111315884Connector · damagedDURING POST-FLIGHT INSPECTION, DISCOVERED "APU FIRE LP 1" STATUS MESSAGE. (<P>TRANSFERRED TO DMI #120417 PER MEL CH 26-15-01-01, CAT "C".</P><P>LP 0994698 - M9: PERFORMED RESISTANCE CHECK 3.2 OHMS. NO TIME TO CHECK UPPER LOOPS, MDDR #120417 REMAINS OPEN PER FISDR UIEA2019110875867Warning Message · false activationAPU FIRE LOOP 1. (<P>PERFORMED APU FIRE DETECTION SYSTEM OPS TEST TWICE, NO DEFECTS NOTED AT THIS TIME. APU FIRE LP 1 REMAINS EXTINGUISHED, NO MESSAGES DISPLAYED REF B767 AMM 26-15-00.</P>)SDR UIEA2019110405852Fire Warning · false activationSTATUS MSG: APU FIRE LP 1.(<P>PERFORMED FIM 26-15 FAULT TREE 804, SYSTEM OPERATES NORMALLY, COULD NOT DUPLICATE.</P>)SDR UIEA2019110405845Status Message · false activationAPU FIRE LP 1 STATUS MSG.(<P>RESET POWER AND CONDUCTED FIRE LOOP TEST, TEST OK IAW AMM 26-15-00.</P>)SDR UIEA2019110305842Warning System · false activationWXR FAIL ON EADI.(<P>CYCLED C/B AND ACCOMPLISHED TEST REF AMM 34-43-00, ALL CHECKS OK.</P>)SDR UIEA2019110405851Lanyard · tornON ARRIVAL, FOUND MAIN ENTRY DOOR ELT LANYARD TORN.(<P>REMOVED AND REPLACED MAIN ENTRY DOOR ELT, REFERENCE AMM 25-63-03.</P>)SDR UIEA2019102985805Pressure Switch · malfunctionedR FWD FUEL PUMP EICAS.(<P>TRANSFERRED TO MDDR #119797 PER DDG 28-22-01, CAT 'C', DUE DATE: 07-NOV-19. MTX PROC C/W, MCC NOTIFIED AND PLACARDS INSTALLED. RESTRICTED TO 120 MIN. </P><P>LP 1212657 - M6: REMOVED AND REPLACED R/H FWD BOOST PUMP IAW AMM 28-22-03. OPSDR UIEA2019102905808Status Message · false activationSTATUS MSG APU FIRE LOOP 1. (<P>TRANSFERRED TO MDDR #119805 IAW MEL 26-15-01-01, CAT C, DUE DATE: 07-NOV-2019. PLACARDS INSTALLED AND MCC NOTIFIED. </P><P>LP 1212659 - M11: PERFORMED TEST AND OPS CHECK OF APU LOOP IAW B767 AMM 26-11-01, OPS CHECK GOOD. PERFORMSDR UIEA2019102905807Warning Message · false activationFIRE/OVERHEAT SYSTEM EICAS ON FINAL.(<P>PERFORMED FIRE/OVERHEAT SYSTEM TEST PER AMM 26-11-01, OPS CHECK GOOD.</P>)SDR UIEA2019102105766Control Valve · leakingAPU OIL COOLER TEMP CONTROL VALVE LEAKING. (<P>DEFERRED APU IAW MEL 49-11-01A, TRANSFERRED TO DMI #119428. MCC NOTIFIED AND ALL PLACARDS INSTALLED.</P><P>LP 1116578 - M18: REMOVED AND REPLACED APU OIL COOLER TEMP CONTROL VALVE IAW B767 AMM 49-27-10. OPS CHECKSDR UIEA2019102105765Controller · malfunctionedCABIN AUTO PRESSURE 2 CONTROLLER EICAS MSG.(<P>REMOVED AND REPLACED AUTO PRESSURE CONTROLLER IAW AMM 21-31-02, OPS CHECK GOOD.</P>)SDR UIEA2019102105771Transmitter · fluctuatesAPU OIL QUANTITY INDICATION FLUCTUATING ON EICAS BETWEEN .50 AND FULL.(<P>REMOVED AND REPLACED OIL QUANTITY TRANSMITTER IAW AMM 49-94-04. OPS CHECK AND LEAK CHECK GOOD.</P>)SDR UIEA2019102105763Fire Warning · false activationFIRE/OVERHEAT SYSTEM ILLUMINATED ON SHORT FINAL.(<P>PERFORMED AUTOMATIC FIRE/OVERHEAT TEST, TEST GOOD PER B767 AMM 26-10-00.</P>)SDR UIEA2019101545713Warning Message · false activationAPU FIRE LOOP 1 STATUS MESSAGE. TROUBLESHOOT IAW FIM 26-15 FAULT TREE 804, STEPS 1 AND 2. SYSTEM OPS CHECK NORMAL AT THIS TIME.SDR UIEA2019101095689Control Valve · failedLEFT PACK OFF. REMOVED AND REPLACED FLOW CONTROL VALVE IAW B767 AMM 21-51-01. LEAK CHECK AND OPS CHECK GOOD.SDR UIEA2019101095691Status Message · false activationSTATUS - CABIN ALTITUDE AUTO 2. PERFORMED AUTO PRESSURE CONTROLLER BITE CHECK, NO FAULTS FOUND. RESET BOX, MESSAGE STAYS EXTINGUISHED REF B767 AMM 21-31-00.SDR UIEA2019100755650Warning Message · false activation"L FWD FUEL PUMP" EICAS MSG DURING CLIMB UNTIL CRUISE. RAN QRH, MSG DISAPPEARED PRIOR TO QRH COMPLETION. COMPLIED WITH FIM 28-22 F/T 819, COULD NOT DUPLICATE FAULT. THE FUEL PUMP OPS NORMAL . ACFT OK FOR SERVICE.SDR UIEA2019100745644Warning Message · false activation"LEFT FWD FUEL PUMP" EICAS MESSAGE CAME ON TWICE, FOR 1 - 2 MINUTES, JUST PRIOR TO REACHING CRUISE ALT. COMPLIED WITH FIM 28-22 FT 819, COULD NOT DUPLICATE. FUEL PUMP OPS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR UIEA2019100215623Status Message · false indicationPRIOR TO ENG START, APU FIRE LP 1 STATUS MSG. C/W OPS TEST OF APU FIRE DETECTOR LOOP IAW AMM 26-15-02. ALSO, INSPECTED ELECTRICAL CONNECTOR AND PIN. FOUND NO ISSUES, OPS CHECK GOOD.SDR UIEA2019093005602Start Valve · not reportedPER POWERPLANT ENGINEERING, CHANGE L/H ENGINE STARTER VALVE. (<P>REMOVED AND REPLACED L/H ENGINE STARTER VALVE IAW B767 AMM 80-11-02. OPS AND LEAK CHECK GOOD AT THIS TIME. </P>)SDR UIEA201910015594Pump · malfunctionedDURING TAXI OUT CENTER LEFT FUEL PUMP EICAS MESSAGE DISPLAYED WITH APPROX 33.1 LBS OF FUEL IN CENTER TANK. REMOVED AND REPLACED LEFT OVERRIDE PUMP IAW AMM 28-22-05. OPS AND LEAK CHECK GOOD AT THIS TIME.SDR UIEA2019100397588Surge Valve · inoperativeAPU PNEUMATIC FUNCTION INOPERATIVE. REMOVED AND REPLACED APU SURGE VALVE IAW AMM 49-53-01, OPS CHECKED GOOD. PERFORMED OPS TEST OF APU IAW AMM 49-05-00, OPS CHECKED GOOD.SDR UIEA2019092105552Status Message · false activationSTATUS MSG AFT EQ EXH FAN 2. AFT EQ EXHAUST FAN 2 PLACED ON MEL 21-58-05, DMI #118029, DUE 01-OCT-19. NO MX ACTION REQUIRED. LP 1211040 - M6; NO EICAS STATUS MESSAGE IN VIEW. #2 AFT EQUIPMENT EXHAUST FAN OPS CHECK NORMAL IAW AMM 21-26-00. THIS CLEARS MDDR 1180SDR UIEA2019092605581Unknown · malfunctionedWX RADAR INOP. PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM. CHECKED NORMAL ON GROUND, NO FAULTS NOTED REF AMM 34-43-00.SDR UIEA2019091805532Unknown · malfunctionedAPU GENERATING INSUFFUCUENT PSI FOR ENGINE START. LESS THAN 15 PSI, ADP WAS IN OFF POSITION. TRANSFERRED TO MDDR 117929 IAW DDG 49-11-01A, CAT 'C', DUE 29SEP19. MCC NOTIFIED AND PLACARDS INSTALLED. LP 1211031 - M1: AMENDED DDG 49-11-01A TO NEW DDG. REF 49-11-0SDR UIEA2019091905542Warning System · false activationSTATUS MSG, RT ENG SPEED CARD. PERFORMED FIM 73-21 FAULT TREE 871. PERFORMED ERASE PROCEDURE AND MSG DID NOT RETURN. SYSTEM CHECKS GOOD AT THIS TIME.SDR UIEA2019091905541Status Message · false activationSTATUS MSG "R ENG SPEED CARD" AFTER TAKEOFF. PERFORMED TEST AS PER FIM 73-21 FAULT TREE 871. SYSTEM OPS CHECK NORMAL.SDR UIEA2019091905540Unknown · malfunctionedL & R RADAR PRODUCING SPOKE ARTIFACTS, MAKING RADAR UNUSABLE. PERFORMED TEST IAW AMM 34-43-00, OPS CHECK NORMAL.SDR UIEA2019091005479Status Message · false activationAFT EQ EXH FAN 2 STATUS MESSAGE. PERFORMED FIM TASK 21-26 FAULT TREE 808 PERFORMED MESSAGE ERASE PROCEDURE PER AMM 31-41-00 MESSAGE REMAINS EXTINGUISHED.SDR UIEA2019090905468Unknown · odorSTRONG SMELL AT ALTITUDE WHEN PACK TEMP WAS SELECTED AFTER. PERFORMED OPS CHECK OF LT PACK NO SMELL PRESENT IAW AMM 21-00-00.SDR UIEA2019090805457Control Valve · malfunctionedR PACK INOP. TRANSFERRED TO MDDR #117481 PER DDG 21-51-01-01 CAT C DUE 18-SEP-19 MX ACTION C/W. R/R FLOW CONTROL VALVE IAW AMM 21-51-01. OPS CK NORMAL DMI CLOSED.SDR UIEA2019090605452Modulating Valve · malfunctionedDURING RIGHT ENGINE START, DUCT PRESSURE OSCILLATED BETWEEN 16 TO 18 PSI. N2 MAX MOTORING WAS 18.3%. TRANSFERRED TO MDDR 117406 IAW MEL 49-11-01-01, CAT "C". LP 1116286 - M3: PERFORMED THE PUSH AND PULL TEST ON IGV IAW AMM 49-52-02 (TEST GOOD), PERFORMED CHIP SDR UIEA2019090905466Pin · stuckF/O OXYGEN MASK "RESET TEST" PIN IS STUCK IN. RESET AND SEATED PIN ON F/O'S OXYGEN MASK BOX. OPS CHECK IS GOOD. REF AMM 35-11-51.SDR UIEA2019090905467Unknown · malfunctionedAPU DUCT PRESSURE EXTREMELY WEAK DURING ENG 2 ENG START. PERFORMED ENGINE RUN IAW AMM 71-00-00. APU DUCT PRESSURE HOLD 30% DURING ENG START. NORMAL OPERATION OBSERVED. NO DISCREPANCY FOUND.SDR UIEA2019083095329Control Valve · failedRIGHT PACK TEMP EICAS MESSAGE DURING DESCENT, FOLLOWED QRH. PERFORMED BITE TEST OF THE PACK TEMP CONTROLLER IAW FIM 21-51 FT 803. FOUND TEMP CONTROL VALVE ON TEMP CONTROLLER. REMOVED AND REPLACED THE RT PACK TEMP CONTROL VALVE IAW AMM 21-51-12. OPS AND LEAK SDR UIEA2019082805309Module · malfunctionedDURING ENGINE START, APU DUCT PRESSURE NO HIGHER THAN 15 PSI. IMPENDING HOT START ON #2 ENGINE, STOPPED START, RESTART SUCCESSFUL. NO EXCEEDANCES. REMOVED AND REPLACED FLOW SENSING MODULE IAW B767 AMM 49-53-08. OPS CHECK GOOD AT THIS TIME.SDR UIEA2019082975306Sensor · malfunctionedEICAS RIGHT PACK TEMP. FOUND APU BLEED DUCT PRESSURE TO BE 8 PSI ON LEFT AND 10 PSI ON RIGHT. BITE CHECK OF APU ECU MINI FLAG 3 & 6. FAULTY APU SURGE CONTROL VALVE. REMOVED AND REPLACED APU SURGE CONTROL VALVE AND REMOVED AND REPLACED BELLOW SEAL, AFT OF APSDR UIEA2019082705300Indication Sys · false indicationDURING ENGINE START, APU DUCT PRESSURE FALLS FROM 25 PSI TO LESS 15 PSI. N2 GETS TO NO MORE THAN 18% N2. NO START LIMITATIONS EXCEEDED. NOTED BY MX. PERFORMED APU BITE IAW AMM 49-11-00/958, OPS NORMAL, NO FAULTS NOTED. PERFORMED ENGINE RUN IAW AMM 71-00-00, ASDR UIEA2019082765288Warning Message · false activationRIGHT PACK OUT CAUTION MESSAGE. TURNING BASE, TURNED PACK OFF. PERFORMED FIM 21-51 FT 803, NO DEFECTS NOTED. OPS TEST GOOD. NO EICAS MSG OR PACK CONTROLLER FAULTS.SDR UIEA2019082105250Hose · tornHOSE BETWEEN PORTABLE O2 BOTTLE AND MASK IS TORN. PORTABLE O2 BOTTLE ON WALL NEXT TO CARGO ACCESS DOOR. (<P>REMOVED AND REPLACED PORTABLE O2 BOTTLE HOSE AND MASK IAW B767 AMM 35-31-01. NO DEFECTS NOTED AT THIS TIME. </P>)SDR UIEA2019082005230Warning Message · false activation"RIGHT PACK TEMP" EICAS MESSAGE DISPLAYED IN FLIGHT. AFTER SWITCHING TO STANDBY-N, THE MESSAGE DISAPPEARED. T/S PER B767 FIM 21-51 FT 807. NO FAULTS NOTED, CAN NOT DUPLICATE ON GROUND. </P>)SDR UIEA2019080984969Controller · failedNR 2 PRESSURE CONTROL SYS STATUS MESSAGE CABIN ALTITUDE SHOWING. REMOVED AND REPLACED THE NR 2 CABIN PRESSURE CONTROLLER IAW AMM 21-31-02, OPS CHECKED GOOD.SDR UIEA2019080804967Warning Message · false activationON DESCENT BELOW 10000 FT, WITH LEFT PACK OFF, RECEIVED RIGHT PACK TEMP ADVISORY. MESSAGE CLEARED AND SWITCHED TO LEFT PACK. PERFORMED PACK TEMP CONTROLLER BITE IAW FIM 21-51 FT 803. NO FAULTS, EICAS MESSAGE CLEARED. NO DEFECTS NOTED.SDR UIEA2019062854573Indicator · malfunctionedCABIN ALTITUDE INDICATOR FLUCTUATES CONSTANTLY, EVEN ON GROUND. CONFIRMED ALT RATE INDICATOR HAS MINOR VIBRATION, BUT STILL OPERATIONAL. REMOVED AND REPLACED CABIN PRESSURE CONTROL PANEL IAW 21-33-01. OPS CHECKED GOOD.SDR UIEA2019062524552Screw · looseSTATUS MESSAGE FOR APU OIL QTY. PERFORMED APU EXTERNAL INSPECTION IAW AMM 49-21-00-206-001. FOUND APU GENERATOR HOUSING SCREWS LOOSE AND LEAKING. SECURED GENERATOR HOUSING SCREWS IAW AMM 20-11-00. REPLENISHED APU OIL IAW AMM 12-15-04. LEAK CHECKED OK AT THSDR UIEA201906054372Ecu · malfunctionedAPU FAULT AND SHUTDOWN ON GROUND. REMOVED AND REPLACED APU ECU IAW AMM 49-61-03. OPS CK NORMAL.SDR UIEA2019060304380Microphone · no testF/O OXYGEN MASK MICROPHONE FAILS TEST. (<P>REMOVED AND REPLACED F/O OXYGEN MASK IAW AMM 35-11-04. </P><P>LP 1088341 - M2: SWAPPED OBSERVER AUDIO SELECTOR PANEL WITH F/O IAW AMM 23-40-00. OPS CHECK GOOD. </P>)
Back to N1709A