N1709A
Service difficulty reports · 455
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018112762704Status Message · false activationSTATUS MESSAGE L ENG FIRE LOOP 2(<P>PERFORMED ENG FIRE LOOP TEST L ENG FIRE LOOP 2 OPS TEST NORMAL PER AMM 26-11-00</P>)SDR UIEA2018111502621Warning Light · false activationRH ENG VALVE LIGHT ON(<P>C/W FIM 76-11 F/T 808 NO FAULTS NOTED AT THIS TIME <BR /></P>)SDR UIEA2018111202572Warning System · false activationLT FWD FUEL PUMP LOW PRESSURE LITE ILLUMINATED IN FLT, LT MAIN TANK FUEL QTY WAS 12.6LBS. PERFORMED OPERATIONAL TEST OF ENGINE FUEL FEED SYSTEM TEST OF ENGINE FUEL FEED PASSED NO DEFECTS NOTED AT THIS TIME AS PER AMM 28-22-00.SDR UIEA2018102902419Pin · malfunctionedFO OXYGEN MASK RESET / TEST LEVER INOP. PIN WILL NOT ENGAGE WITH O2 MASK. RESET PIN, PERFORMED OPS CHECK PIN & MASK IN OK CONDITION IAW AMM 35-11-52.SDR UIEA2018102102296Valve · malfunctionedAPU INOP REVERSE FLOW. REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01. OPS TEST GOOD.SDR UIEA2018102102295Relief Valve · faultyEICAS MSG RT ENGINE PRV. REMOVED AND REPLACED PRV AND CONTROLLER IAW AMM 36-11-18 & 36-11-19. OPS CK NORMAL.SDR UIEA2018102102307Controller · not reportedRT ENG PRESSURE CONTROLLER. REMOVED AND REPLACED RIGHT ENGINE PRESSURE CONTROLLER IAW AMM 36-11-19. OPS CHECK GOOD NO DEFECT NOTES.SDR UIEA2018102202319Status Message · false activationSTATUS MSG: RT ENG PRV. PERFORMED FIM 36-10 FLT 878- N0 DEFECTS NOTED, ALL SUPPLY BITE NO FAULTS EICAS MSG CLEARED.SDR UIEA2018102102305Warning System · activatedAPU INOP REVERSE FLOW FAULT. TRANSFER TO MDDR 101485 IAW MEL 49-11-01A CAT C DUE DATE 31 OCT -18.SDR UIEA2018102102306Relief Valve · malfunctionedEICAS MSG RT ENG PRV. REMOVED AND REPLACED RT ENG PRV IAW AMM 36-11-18. OPS CHECK NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018101802284Exciter · malfunctionedAPU FAULT. APU INOP. PERFORMED OPS CHECK OF APU IAW AMMM 49-11-00. NO LIGHT OFF (NO EGT RISE) BITE CHECK OF ECU IAW FIM 49-11-FT958, ECU BITE SAID IGN UNIT. R&R APU EXCITER BOX IAW AMM 49-41-03. REMOVED AND REPLACED APU IGNITION LEAD IAW AMM 49-41-04, P/N 3888SDR UIEA2018101602274Unknown · malfunctionedON INITIAL CLIMBOUT WXR FAILED, BUT CAME BACK. PERFORMED OPERATIONAL TEST ON WXR SYSTEM IAW AMM 34-43-00-715, OPS CKD GOOD AT THIS TIME.SDR UIEA2018101602275Light · inoperativeAPU BLEED FLOW BAR INOP. RELAMPED BLEED SWITCH IAW AMM 33-10-01. OPS CK OK.SDR UIEA2018101502262Wire · shortedAPU GENERATOR INOP. R&R APU GENERATOR IAW AMM 24-21-01 FAILED PS CHECK. T/S APU GEN PMG FAULT & FOUND WIRE 242-301R-18 SHORTED. REPLACED WIRE IAW IAW SWPM 20-10-13. PERFORMED GOOD OPS CHECK OF APU GEN IAW AMM 24-21-00 NO FURTHER ACTION REQUIRED.SDR UIEA2018101502263Wire · shortedAPU (FISHPOLE HLST PROCEDURE) (ETOPS) APU OFF: P-1672/ APU ON: P-2300. COMPLIED WITH TASK CARD A-49-999-00-01. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01 FAILED OPS CHECK. T/B APU GENE PMG FAULT FOUND WIRE W 242-30R-18 SHORTED. REPAIRED WIRE IAW SWPM SDR UIEA2018101502264Wire · missingDURING ENG RUN NR 2 BLEED LIGHT ILLUMINATED. TROUBLESHOOT ENG NR 2 BLEED IAW FIM 36-10-00 TREE 847 FOUND WIRE MISSING, SAME INSTALLED IAW WDM 36-11-62 OF THE P37. OPS CHECK CARRIED OUT IAW AMM 71-00-00, OPS CHECK SATISFACTORY.SDR UIEA2018101102244Battery Pack · dischargedEMERGENCY LIGHTS FAIL OPS CHECK. REMOVED AND REPLACED NEW BATTERY PACK IAW AMM 33-51-07. PERFORMED SATISFACTORY OPS CHECK IAW AMM 33-51-07 STEP E.SDR UIEA2018101102241Duct · leakingLT EACAS BAY DUCT LEAKING FWD 1/B SIDE. REMOVED AND REPLACED LT EACAS BAY DUCT 1/B GASKET IAW AMM 21-51-04 AND PERFORMED LEAK CHECK IAW AMM 21-51-04 NO LEAK NOTED.SDR UIEA2018101102242Seal · not reportedRT EACAS BAY AFT DUCT LEAKING. REMOVE AND REPLACED SEAL A7 RT BODY CROSSOVER DUCT O/B OF CHECK VALVE IAW AMM 36-11-01. PERFORMED GOOD LEAK CHECK IAW AMM 36-11-01 NO LEAKS NOTED.SDR UIEA2018101102243Controller · not reportedSTAND BY PACK CONTROLLER FAILS REQUIRES REPLACEMENT. REMOVED AND REPLACED STANDBY PACK CONTROLLER IAW AMM 21-51-14-400. PERFORMED SATISFACTORY OS CHECK IAW AMM 21-51-06-700.SDR UIEA2018101102240Connector · looseLT EACAS BAY O/B SIDE, PNEUMATIC DUCT TEMP SENSOR CONNECTOR HAS LOOSE BACKSHELL JUST AFT OF LT FLOW CONTROL VALVE. REMOVE AND REPLACE CONNECTOR ON 02152 IAW SWPM 20-61-00, PERFORM SATISFACTORY OPS CHECK ON SENSOR IAW AMM 21-52-08 STEP F.SDR UIEA2018090701913Warning System · false activationLT ENGINE BLEED LIGHT ILLUMINATED IN CLIMB OUT WITH NO EICAS MSG. NO FAULTS NOTED AT THIS TIME REF FIM 36-20-00. OPS CHECK GOOD IAW AMM 36-11-00-715-149.SDR UIEA2018090701924Circuit Card · not seatedLEFT ENG BLEED LIGHT ON DURING TAKEOFF AND INITIAL CLIMB. EXTINGUISHED APPROX 7 MIN AFTER TAKE OFF. NO EICAS MSG. NO FAULTS NOTED ON AIR SUPPLY BITE PER FIM 36-20-00. RERACKED LEFT BLEED AIR CONTROL CARD REF AMM 36-11-12. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018090401880Warning System · false activationOVERHEAD LEFT ENGINE BLEED LIGHT ILLUMINATED ON INTIAL CLIMB FOR A FEW MINUTES, NO EICAS MESSAGE. PERFORMED FIM 36-20 TREE 804, PERFORMED BITE OF AIR SUPPLY MODULE LT ENGINE NO FAULTS NOTED.SDR UIEA2018090501894Controller · malfunctionedOVERHEAD LEFT ENGINE BLEED LIGHT ILLUMINATED ON CLIMB OUT. NO EICAS MSG, REPLACED LT ENG HP CONTROLLER IAW AMM 36-11-08. OPS & LEAK CHECK OK.SDR UIEA2018090501895Circuit Card · dirtyLT ENG BLEED LIGHT ON, ON TAKEOFF ROLL NO EICAS MSG LIGHT GOES OUT AFTER FIRST POWER REDUCTION ALL PARAMETERS NORMAL. CLEANED PINS ON M859 LT BLEED AIR CONTROL CARD AT P50 PANEL. RE-RACKED. ALL OPS OK PER AMM 36-11-12. NO FAULTS ON BITE.SDR UIEA2018090101863Warning Light · false indicationLT ENG BLEED DISCRETE LT ON OVERHEAD PANEL ILLUMINATED DURING INITIAL CLIMB. NO EICAS MSG. LT WENT OUT AFTER 2-3 MINS. RECURRING WRITE-UP. PERFORMED BITE TEST PROCEDURE IAW FIM 36-20-00 FAULT TREE 804. NO FAULTS FOUND.SDR UIEA2018083101861Terminal · brokenLT ENG FIRE LP 1 STATUS MSG. T/S ENGINE 1 FIRE LOOP 1. RANG OUT WIRES AT ENGINE PYLON TO FIRE DETECTOR ELEMENTS, FOUND TO BROKEN TERMINALS ON UPPER AFT AND LOWER AFT ELEMENTS. REPLACED 2 TERMINALS FOR UPPER AND LOWER ELEMENTS IAW SWPM 20-30-11. OPS CHECK TEST SDR UIEA2018090401886Fire Warning · false activationLT ENG FIRE LP1 STATUS MSG. STATUS MESSAGE NOT CURRENTLY SHOWN. PERFORMED ENGINE FIRE DETECTION, OPS CHECK IAW 26-11-00. NO DEFECTS NOTED. GOOD FOR SERVICE.SDR UIEA2018090401885Valve · malfunctionedLT ENGINE BLEED OFF MSG, FAMV FAULT. REMOVED AND REPLACED FAN AIR VALVE IAW AMM 36-11-16. PERFORMED TEST OK.SDR UIEA2018083001857Fire Warning · false activationAPU FIRE LP 1 STATUS MSG. PERFORMED FIRE DETECTION BITE PROCEDURE IAW FIM 26-15 TASK 804, FAULT CLEARED.SDR UIEA2018083001858Fire Warning · false activationFIRE / OVHT SYS EICAS ILLUMINATED ON SHORT FINAL. PERFORMED FIRE DETECTION BITE PROCEDURE IAW FIM 26-15 FT 804 FAULT CLEARED.SDR UIEA2018083001852Modulating Valve · faultyLEFT ENGINE BLEED INOP / (FAN AIR (PRECOOLER) CONTROL SYSTEMS. REMOVED AND REPLACED FAN AIR MODULATING VALVE IAW AMM 36-11-16 , PERFORMED OPERATIONAL TEST AND FAN AIR VALVE BITE TEST IAW AMM 36-11-16 NO FAULTS NOTED, THE SYSTEM WORKS NORMAL AT THIS TIME.SDR UIEA2018083001847Status Message · false activationLT ENG FIRE LP1 STATUS MSG. STATUS MESSAGE NOT CURRENTLY SHOWN. PERFORMED ENGINE FIRE DETECTION OPS CHECK IAW 26-11-00. NO DEFECTS NOTED. GOOD FOR SERVICE.SDR UIEA2018082901840Warning System · false activationDURING CLIMB OUT, LT ENG BLEED LIGHT ILLUMINATED, BUT NO EICAS MSG, WENT AWAY. FOLLOWED FIM 36-20 FAULT TREE 804, PERFORMED BITE TEST ON AIR SUPPLY, NO DEFECTS NOTED AT THIS TIME. HPSOV PLACE ON ORDER AS PRECAUTIONARY. P/N 802170-12. VISUALLY INSP HPSOV, NO DESDR UIEA2018082901842Warning System · intermittentLEFT BLEED LIGHT ILLUMINATED INTERMITTENTLY DURING CLIMB. NO ASSOCIATED EICAS OR CAUTION. PER FIM 36-20-43 804 PERFORMED BITE CHECK ON AIR SUPPLY MODULE NO DEFECTS NOTED AT THIS TIME A/C OK FOR SERVICE.SDR UIEA2018082401789Warning System · false activationLT ENGINE BLEED LIGHT ON OVERHEAD PANEL ILLUMINATED DURING INITIAL CLIMB. LIGHT EXTINGUISHED AFTER APPROXIMATELY 1 MIN. NO EICAS. THIS IS A REPEAT WRITE UP. PERFORMED AIR SUPPLY BITE TEST IAW AMM 36-23-00-715-001. OPS CHECK GOOD, NO FAULTS NOTED AT THIS TIME.SDR UIEA2018082701812Unknown · malfunctionedWEATHER RADAR SEEMED TO NOT DEPICT HEAVY WEEATHER VISIBLE TO FLIGHT CREW. ON APPROACH, WX RADAR DEPICTED MOD/HEAVY RAIN BUT WE ONLY ENCOUNTERED LT RAIN. GROUND OPERATIONAL CHECKS GOOD IAW 34-43-00/501.SDR UIEA2018082201767Unknown · malfunctionedWEATHER RADAR NO DEFIC HEAVY WEATHER VISIBLE TO FLIGHT CREW ON APPROACH WX RADAR MOD/HEAVY RAIN BUT WE ONLY ENCOUNTERED LT RAIN. GROUND OPERATIONAL CHECK GOOD IAW AMM 34-43-00.SDR UIEA2018081401693Smoke Detector · inoperativeSMOKE DETECTOR POS A2 INOP.REMOVED AND REPLACED A2 SMOKE DETECTOR IAW AMM 26-19-01.SDR UIEA2018081301683Warning System · false activationLEFT BLEED LIGHT ON OVERHEAD PANEL ILLUMINATED BRIEFLY IN FLIGHT. INTERROGATED M-129 BLEED AIR SUPPLY MODULE AND RESET ACOMPLISHED LT ENG RUN AND BLEED AIR CHECK PER AMM 36-11-00 BITE TEST OF M-129 AIR SUPPLY MOD SHOWS NO FAULTS NO SUBSEQUENT BLEED OFF LIGHTS SDR UIEA2018081301684Not Reported · malfunctionedMAIN TANK IN FLIGHT FUEL IMBALANCE OF 1200LBS (LEFT LOW/RIGHT HIGH). BITE TEST OF M-121 FUEL QTY PROCESSOR SHOWS NO FAULTS FUEL CONFIG LIGHT DID NOT ILLUMINATE AND NO ASSOCIATED EICAS MSG IN VIEW SUSPECT 1200LB APU FUEL BURN DUE TO 4 PLUS HOUR DELAY INBD. NOTESDR UIEA2018081301678B-Nut · looseDURING CRUISE LEFT DUCT PRESSURE 10 PSI THE BLEED DISCRET LIGHT ON OVERHEAD PANEL CAME ON FOR SEVERAL SECONDS. REF LOG PAGE 0965172 ITEM 3. T/S BLEED SYSTEM AND FOUND LOOSE B NUT ON PRV SUPPLY PRESSURE LINE, TIGHTEN B NUT OPS CK WITH ENGINE RUNNING GOOD IAW FISDR UIEA2018081001644Warning System · false activationCARGO FIRE SMOKE DETECTOR A2 LIGHT ILLUMINATED. PERFORMED OPERATIONAL TEST OF CARGO DETECTION SYSTEM WITH NO FAULTS PER FIM 26-19F/T 809.SDR UIEA2018081301677Connector · defectiveDURING CRUISE LEFT DUCT PRESSURE 10 PSI. THE BLEED DISCRETE LIGHT ON OVERHEAD PANEL CAME ON FOR SEVERAL SECONDS. REPLACED ELECTRICAL CONNECTOR D4156P, WHICH IS DAMAGED IAW SWPM 20-35-11. SECURED CONNECTOR ON STRUT DISCONNECT PANEL. OPS CK REQUIRED.SDR UIEA2018081301674Seal · damagedLEFT DUCT SHOWING 5 PSI IN FLIGHT AT CRUISE. RECONNECTED SEPARATED LT ENGINE PNEUMATIC SUPPY DUCT, AND REPLACED SEAL UPSTREAM OF LOW AND HIGH PRESSURE "Y" MANIFOLD PER MM CH 36-11-01. LK & OPS-CK GOOD ON ENGINE MX RUN IAW MM CH 71-00-00 AND CH 36-00-00.SDR UIEA2018081001645Wire Harness · defectiveLEFT FUEL FLOW INDICATION INOP. (NO CALCULATED FUEL ON FMS). REPLACED W13 HARNESS ON NR 1 ENG IAW AMM 73-21-18. FUEL FLOW CHECK DURING ENGINE RUNS IAW AMM 71-00-00.SDR UIEA2018081501698Not Reported · malfunctionedLEFT ENGINE N1, DURING CLIMB COULD NOT ALIGN THE COMMANDED N1, DUE TO HIGH N2. LEFT N2 IN CLIMB WAS 109.2. PERFORMED ENG RUNS PER IAW 71-00 ALL PARAMETERS NORMAL.SDR UIEA2018081301676Duct · separatedLEFT ENG BLEED OFF EICAS MESSAGE DURING FLIGHT. RECONNECTED SUPPLY DUCT, PERFORMED ENG RUNS IAW 36-11-00 AND 71-00. ALL OPS NORMAL.SDR UIEA2018081301675Idg · lowLEFT IDG VALVE STATUS MESSAGE. SERVICED LEFT IDG IAW MM CH 12-13-03. SYSTEM CK'S GOOD DURING ENGINE MX RUN PER MM CH 24-11-00.