N1709A
Service difficulty reports · 455
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1709A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018081301673Control Valve · inoperativeNR 1 ENG STARTER CONTROL VALVE INOP. REMOVED AND REPLACED NR 1 ENG STARTER CONTROL VALVE IAW AMM 80-11-02. OPS CK GOOD.SDR UIEA2018080201608Unknown · malfunctionedWXR FAIL. PERFORMED OPS CHECK ON LEFT AND RIGHT WX SYS IAW AMM 34-00-715-001-001, BOTH PASSED OPS NORMAL.SDR UIEA2018080201607Warning System · false activation"WXR FAIL". PERFORMED OPS CHECK ON LEFT AND RIGHT WX SYSTEM IAW AMM 34-43-00-715-001-001. BOTH PASSED, OPS NORMAL.SDR UIEA2018073001590Cover · looseRT AFT FUEL PUMP INOP. RESECURED SWITCH ASSEMBLY. SWITCH COVER WAS LOOSE. IAW 28-21-00.SDR UIEA2018071301457Warning System · false activationWEATHER RADAR FAILED IN FLIGHT. PERFORMED OPS AND SYSTEM TEST OF LT AND RT WEATHER RADAR REF AMM 34-43-00 NO FAULTS NOTED AT THIS TIME, OK FOR SERVICE.SDR UIEA2018070601367Actuator · failedAPU WOULD NOT START AFTER TWO ATTEMPTS, FAULT LIGHT ILLUMINATED ON BOTH ATTEMPTS. R&R INLET GUIDE VANE ACTUATOR IAW AMM 49-52-02. OPS CHECK OK.SDR UIEA2018062301222Control Panel · unsecure"WX FAIL" MSG DISPLAYED. CLEANED AND RESECURES WX CONTROL PANEL AND PERFORMED OPS TEST IAW AMM 34-43-00-715-001-001. NO FAULTS NOTED AT THIS TIME.SDR UIEA2018062301223Warning System · false activationEICAS MSG "TAT PROB". PERFORMED OPERATIONAL TEST OF TAT IAW AMM 30-33-00-715-010. NO FAULTS NOTED AT THIS TIME.SDR UIEA2018061301148Detector · inoperativeNR 2 ENG FIRE LOOP NR 1 INOP "EICAS MSG". REPLACED AFT LOWER DETECTOR ASSY, ENGINE 2 IAW AMM 26-11-02 OPS CHECK NORMAL.SDR UIEA2018061301149Unknown · malfunctionedRT PACK EXHAUST DOOR DID NOT CLOSE IN FLT MODE. PERFORMED ACTUATOR CHECK OPS CHECKS NORMAL IAW AMM 21-53-01.SDR UIEA2018061301150Actuator · inoperativeRIGHT DEFUEL VALVE ACT UNABLE TO TRANSFER FUEL. REMOVED AND REPLACED ACTUATOR OPS CHECK NORMAL IAW AMM 28-26-11.SDR UIEA2018061301151Actuator · malfunctionedRIGHT RAM AIR INLET DOOR ACTUATOR. R&R RIGHT HAND RAM AIR DOOR ACTUATOR OPS CHECK GOOD IAW AMM 21-53-01.SDR UIEA201806051026Fire Detector · failedRIGHT ENGINE FIRE LOOP NR 2 STATUS MESSAGE DISPLAYED. R & R THE UPPER AFT FIRE DETECTOR ASSY IAW AMM 26-11-02. OPS CHECKED WITH NO ISSUES NOTED.SDR UIEA201806011010Circuit Breaker · trippedEICAS MESSAGE FOR THE CENTER LT FUEL PUMP. COMPLIED WITH QRH, TURNED THE PUMP OFF. MESSAGE CLEARED. FOUND C369 CIRCUIT BREAKER TRIPPED AT THE P6. RESET THE CIRCUIT BREAKER IAW AMM 20-60-01. ACCOMPLISHED FIM 28-22 TASK 812. LEFT CENTER FUEL PUMP OPS CHECKESDR UIEA2018051870909Warning Message · false activationTAT PROBE EICAS MESSAGE AFTER LANDING. PERFORMED AN OPS TEST OF THE TAT PROBE HEAT SYSTEM IAW AMM 30-33-00, OPS CHECKED GOOD, NO DEFECTS NOTED.SDR UIEA2018051500897Warning System · false activationTAT PROBE MESSAGE ON EICAS. BITE MODULE, NO FAULTS FOUND IAW FIM 30-33 FAULT TREE 803. SYSTEM NORMAL.SDR UIEA201805290977Radar · intermittentWEATHER RADAR FAILED ON TAKEOFF, RESUMED OPERATION AT FL 350. ACCOMPLISHED A BITE TEST OF THE WEATHER RADAR, NO FAULTS FOUND. OPS CHECKED GOOD IAW FIM 34-43-00, AND AMM 34-43-00.SDR UIEA2018040300522Sensor · intermittentDURING CRUISE FLIGHT, N1 INDICATION FLUCTUATED INTERMITTENTLY, FOR THE NR 1 ENGINE. REMOVED AND REPLACED THE NR 1 ENG N1 FAN SPEED SENSOR IAW AMM 77-12-01. OPS CHECKED NORMAL IAW AMM 71-00-00.SDR UIEA2018031200368Battery · dischargedAPU BATTERY DISCHARGED, CONSIDERED APU INOPERATIVE. REMOVED AND REPLACED THE APU BATTERY IAW AMM 24-31-04.SDR UIEA2018022800308Radar · malfunctionedLEFT AND RIGHT RADAR SHOWING SPIKES ON ALL RANGES WELL AS TILT SETTINGS. PERFORMED AN OPERATIONAL CHECK OF THE LEFT AND RIGHT WEATHER RADAR SYSTEM , OPS TESTED GOOD IAW AMM 34-43-00.SDR UIEA2018022600280Pump · intermittentDURING CRUISE, LEFT FWD FUEL PUMP PRESSURE INTERMITTANT. OPS CHECKED THE FUEL PUMP IAW AMM 28-22-00, OPS CHECKED GOOD. OK FOR SERVICESDR UIEA2018020800194Connector · damagedWITH FUEL IN CENTER TANK AND AFTER SELECTING CENTER PUMPS ON, THE LEFT CENTER PUMP DID NOT LOD SHED , RIGHT INDICATED NORMAL OPERATION. REPLACED THE CONNECTOR AT LT OVERRIDE PRESSURE SWITCH IAW SWPM 20-61-11. REMOVED AND REPLACED THE LEFT OVERRIDE PRESSURESDR UIEA2018020300170Warning Message · false activationPRIOR TO PUSH CREW NOTED NO EGT, FUEL FLOW AND OIL TEMP INDICATION. PERFORMED AN ENGINE START IAW AMM 71-00-00-862-053-H03, ENGINE OPS NORMAL, ALL INDICATION NORMAL.SDR UIEA2018020100161Pressure Switch · malfunctionedAT LEVEL OFF AT FL 360, THE LT FWD FUEL PUMP EICAS MESSAGE CAME ON , AND THE LT FWD FUEL PUMP PRESSURE SWITCH LIGHT ILLUMINATED EICAS MESSAGES AND PRESSURE LIGHT, WENT OUT REPLACED LT FWD BOOST PUMP PRESSURE SWITCH; SYSTEM CHECKED GOOD IAW AMM 28-42-01.SDR UIEA2018020200168Control Panel · malfunctionedPRE DEPARTURE, CABIN ALTITUDE AUTO 1 STATUS MESSAGE. REMOVED AND REPLACED THE CABIN PRESSURE SELECT PANEL. OPS NORMAL IAW AMM 21-31-01.SDR UIEA2018020100163Selector Panel · malfunctionedDURING PRE DEPARTURE, THE CABIN ALTITUDE AUTO 1 STATUS MESSAGE. REMOVED AND REPLACED THE CABIN PRESSURE SELECTOR PANEL. OPS CHECKED GOOD IAW AMM 21-31-01.SDR UIEA2018020100162Switch · inoperativeRIGHT UTILITY BUSS ON LIGHT IS INOPERATIVE. REMOVED AND REPLACED THE RT UTILITY BUSS SWITCH IAW AMM 36-16-02.SDR UIEA2018012400108Controller · malfunctionedEICAS STATUS MESSAGE "CABIN ALT AUTO 1" NOTE: BITE ON BOX FAULTS SELECTED. REMOVED AND REPLACED CABIN PRESSURE CONTROLLER, OPS CHECKS OK.SDR UIEA2018012200098Coupling · leakingNR 2 PACK SECONDARY HEAT EXCHANGER LEAKING AT COUPLING. REMOVED AND REPLACED THE COUPLING IAW IAW AMM 21-51-02.SDR UIEA2018012200099Switch · damagedTEMPERATURE CONTROL PANEL, TRIM AIR SWITCH BINDING. REMOVED AND REPLACED THE TRIM AIR SWITCH IAW SPM 20-84-13.SDR UIEA2018012200100Seal · leakingNR 1 PACK SECONDARY HEAT EXCHANGER LEAKING AT COUPLING. REMOVED AND REPLACED THE COUPLING SEALS IAW AMM 21-57-01.SDR UIEA2018012200101Feeder Cable · damagedLEFT ENGINE POWER FEEDER CABLE HEAT SHRINK FOR THE IDG DAMAGED. INSTALLED THE HEAT SHRINK IAW SWPM 20-10-14.SDR UIEA2018012200102Feeder Cable · damagedRIGHT ENGINE POWER FEEDER CABLE HEAT SHRINK FOR IDG DAMAGED. INSTALLED HEAT SHRINK IAW SWPM 20-10-14.SDR UIEA2018012200103Liner · damagedNR 1 ENGINE MID OUTER LINER IN THE 2 POSITION, HAS SEVERAL HOLES. REMOVED AND REPLACED THE LINER IAW AMM 72-33-01.SDR UIEA2018011900090Unknown · vibrationDURING INITIAL CLIMB, AS FLAPS WERE RETRACTING 5 TO 1, AN AMBER REVERSER MESSAGE APPEARED FOR THE LEFT ENGINE. DECLARED AN EMERGENCY, PERFORMED QRH PROCEDURE, RETURNED TO DEPARTURE. RUMBLE & VIBRATION NOTED ABOVE 120 KIAS. PERFORMED UNUSUAL CONDITION INSPECSDR UIEA2018010600017Pressure Switch · failedRIGHT AFT FUEL PUMP PRESSURE LIGHT IS NOT ILLUMINATED WITH PUMP TURNED OFF. R & R THE RT AFT BOOST PUMP PRESSURE SWITCH IAW AMM 28-42-01, LEAK AND OPS CHECKED OK.SDR UIEA2018010800038Apu · unknownAPU INOPERATIVE. PERFORMED AN APU OPS TEST IAW AMM 49-11-00, OPS TESTED OK.SDR UIEA2018010800041Circuit Card · failedRIGHT ENGINE SPEED CARD MESSAGE DISPLAYED. REMOVED & REPLACED THE NR 2 ENGINE N2 SPEED CARD IAW AMM 73-21-54. OPS CHECKED OK.SDR UIEA2017121902416Switch · brokenRIGHT AFT FUEL PUMP SWITCH BROKEN. REMOVED AND REPLACED CONTROL PANEL ASSY IAW AMM 28-22-17.SDR UIEA2017121102390Duct · rupturedAPU BLEED DUCT COUPLING IS RUPTURED (<P>REMOVED AND REPLACED BLEED DUCT AS PER 49-53-01 OPS CHECK GOOD,LEAK CHECK GOOD , NO DEFECTS NOTED AT THIS TIME </P>)SDR UIEA2017121102389Control Panel · malfunctionedR GEN LIGHT INOP (<P>REMOVED AND REPLACED SERVICEABLE GEN CONTROL PANEL AS PER AMM 24-22-01 OPS CHECK GOOD </P>)SDR UIEA2017121102391Switch · malfunctionedRIGHT ENG VALVE LIGHT DID NOT ILLUMINATE ON START OR SHUTDOWN (<P>TRANSFERRED TO MDDR # 86908 AS PER MEL 73-21-03-01 CAT C </P><P>LOG PAGE 944350 REMOVED AND REPLACED RH ENG VALVE KORRY SWITCH AS PER AMM 33-13-00 OPS CHECK NORMAL MDDR # 86908 CLOSED </P>)SDR UIEA2017112202280Control Panel · inoperativeWEATHER RADAR FAILED ON BOTH ND WITH RR/T BUTTON SELECTED. REMOVED AND REPLACED THE WEATHER RADAR CONTROL PANEL IAW AMM 34-43-02. OPS CHECKED GOOD.SDR UIEA2017110802203Control Panel · malfunctionedWEATHER RADAR WILL ONLY TILT 11 DEGREES DOWN. REPLACED THE WEATHER RADAR PANEL IAW AMM 34-43-02, OPS CHECKED GOOD.SDR UIEA2017110602178Switch · unsecureLEFT CENTER PUMP SWITCH FALLING OUT OF IT`S SOCKET. REMOVED AND REPLACED THE BOOST PUMP SWITCH IAW SWDM 20-83-00, OPS CHECKED GOOD.SDR UIEA2017110402171Controller · failedRIGHT ENGINE PRV EICAS MESSAGE ANNUNCIATED DURING CLIMB AT APPROXIMATELY 10000 FT. REPLACED THE NR 2 ENGINE PRV CONTROLLER IAW AMM 36-11-19, OPS CHECKED OK.SDR UIEA2017102902134Idg · failedAFTER ENGINE START, LT GEN OFF LIGHT ILLUMINATED, LT GEN DRIVE EICAS MESSAGE CAME ON, ATTEMPTED RESET IAW QRH PROCEDURE UNSUCCESSFUL. REPLACED THE LT GCU IAW MM 24-22-02, GCU REMAINS OPEN. IDG REPLACED, LEAK AND OPS CHECKED NORMAL.SDR UIEA2017103002139Status Message · false indicationSTATUS MESSAGE R ENG PRV. STATUS MESSAGE CLEARED IAW AMM REF 36-00-00.SDR UIEA2017102201991Radar · unknownBOTH WEATHER RADARS INOPERATIVE. PERFORMED AN OPS CHECK OF THE WEATHER RADAR SYSTEM, OPS CHECKED GOOD IAW AMM 34-45-00.SDR UIEA2017100201913Bleed Valve · inoperativeAPU AUTOSHUTDOWN WHEN TURNING THE LT PACK OFF, RIGHT PACK WAS ALREADY OFF. PERFORMED A BITE CHECK IAW FIM 49-11, FT 958. BITE REVERSE FLOW, MINI FLAG, NO FAULTS. REMOVED AND REPLACED THE SURGE BLEED VALVE, CHECKED OK IAW 49-53-01.