N178DZ
Service difficulty reports · 153
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N178DZ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N178DZ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022032401988Unknown · unknownSHIP 1708 FOUND R1 DOOR SLIDE ARMED INDICATOR LIGHT INOP, CORRECITVE ACTION: REMOVED AND REPLACED R1 DOOR SLIDE LT ASSY PER B767-300 AMM 33- 13. OPS NML. (8869108)SDR DALA2022010100004None · noneSHIP 1708 UNABLE TO ARM L2 DOOR. CORRECTIVE ACTION: INSTALLED AND ADJUSTED LATCH PIN PER MM 52-11. (8245272)SDR DALA2021112507277None · noneSHIP 1708 FOUND EMER EXIT LIGHT INOP IN LLCR. CORRECTIVE ACTION: R/R EMER EXIT LIGHT IN LLCR REF B767-300 AMM 3351. OPS CHK NML. (8161340)SDR DALA2021072304176Sign · inoperativeSHIP 1708 EMERGENCY LIGHTS AT CHAIR LOCATION ARE INOPERATIVE. CORRECTIVE ACTION: REPLACED EXIT SIGN. SYSTEM OPERATION IS NORMAL. (LP 7453849)SDR DALA2021071303958Sign · inoperativeSHIP 1707 CREW REST EMERGENCY EXIT SIGN LIGHT INOPERATIVE. CORRECTIVE ACTION: REPLACED AFT WALL MOUNT EXIT SIGN MCO/PLAC REMOVED,SDR DALA2021071203879Switch · faultedSHIP 1708 MAIN ENTRY/SERVICE DOOR ARMED INDICATION LIGHT CORRECTIVE ACTION: REPLACED SLIDE ARM SWITCH. SYSTEM OPERATION IS NORMAL. (LP 1866341)SDR DALA2021062903561Switch · bindingSHIP 1708 L1 DOOR DOWN SWITCH ON P21 PANELS STICKING. CORRECTIVE ACTION: REPLACED L1 DOOR SWITCH. SYSTEM OPERATION IS NORMAL. (LP 7616978)SDR DALA2021040702039Connector · damagedSHIP 1708 DURING MIDLIFE REFRESH OF EXIT SIGNS WHILE TERMINATING NEW HARNESS MAINTENANCE FOUND CONNECTOR D10720 PIN 13 POPULATED AT M1209. ACCOMPLISHED WIRE TERMINATION DEVIATION. SYSTEM OPERATION IS NORMAL. (LP 1775056)SDR DALA2021012700515Panel · delaminatedDURING INSPECTION MAINTENANCE FOUND DELAMINTATION ON VERTICAL STAB RT FWD TORQUE BOX PANEL NR 175T2001. C/W ERA 589568-14.SDR DALA2021012700522Panel · delaminatedDURING INSPECTION MAINTENANCE FOUND 2 LOWER BAYS DELAMINATED ON PANEL 175T2001-4. REPAIRED PER ERA 589581-14 AND SRM 51-70-10.SDR DALA2020121604117Connector · unsecureEMERGENCY LIGHTS AT SEAT 13GF ARE INOPERATIVE. MAINTENANCE RE-SECURED CONNECTOR UNDER SEAT 13GF. SYSTEM OPERATION IS NORMAL.SDR DALA2020040102115Fuse · blownEMERGENCY LIGHTS INOPERATIVE AT SEATS 13-20FG. MAINTENANCE REPLACED FUSE 4 BATTERY PACK M102 SYSTEM OPERATION IS NORMAL (LP6926794)SDR DALA202002030824Battery Pack · inoperativeEMERGENCY LIGHTS AT ROWS 13-20 ARE INOPERATIVE. REPLACED BATTERY PACK ASSEMBLY. SYSTEM OPERATION IS GOOD.SDR DALA2020010900171Lens · missingCROSS AISLE EXIT SIGN LENS MISSING AT 2R. REPLACED LENS (LP 7215574)SDR DALA2019121707371Trigger · misinstalledDURING RT WING SLIDE REPLACEMENT FOUND INFLATION TRIGGER INSTALLED INCORRECTLY AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA2019121217242Battery Pack · inoperativeFOUND EMERGECY LGITHS DIM AT SEATS 13G-20G. REPLACED BATTERY M1209. SYSTEM OPERATION IS NORMAL.SDR DALA2019120317012Battery Pack · looseL1 F/A SEAT BATTERY PACK LOOSE IN SUPPLY. SCREWS NEED TO BE ENGAGED. ENGAGED L1 EMERGENCY BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2019070904159Motor · inoperativeON PREFLIGHT FO ELECTRICAL SEAT SPARKED ON AFT MOVEMENT POWER CORD APPEARS TO BE PINCHED. FOUND SEAT POWER MOTOR INOPERATIVE. REPLACED F/O SEAT MCO/PLAC REMOVED.SDR DALA2019070103960Charger · inoperativeDURING SERVICE CHECK FOUND EMERGENCY LIGHTS INOPERATIVE 13FG TO 20FG IN SEAT. REPLACED CHARGER. SYSTEM OPERATION IS NORMA.SDR DALA2019052803252Oven · smokeOVEN #5 SMOKING WHEN HEATING. CLEANED COMPARTMENT AIR EXTRACTION FILTER. AND REPLACED OVEN. SYSTEM OPERATION IS NORMAL.SDR DALA2019031101728Stringer · damagedBULK CARGO COMPARTMENT FOUND 01EA STRINGER UPPER EDGE DAMAGE AT STA1562 TO STA1582, S-31L. STRINGER REPLACED. (LP 0979576)SDR DALA2019030901726Skin · crackedFUSELAGE BETWEEN STA1654.5 AND STA1678. S-13AL. CRACKED SKIN AND REPAIRED PER SRM 53-80-01. (LP 0976711)SDR DALA2019030901725Skin · dentedLT WING I/B SLAT NO 6 UPPER SKIN O/B FOUND DENT. REPAIRED PER SRM 57-43-02-2R-1 & SRM 51-70-10. (LP 0976391)SDR DALA2019030901724Skin · dentedLT WING O/B SLAT NO 2 UPPER O/B EDGE FOUND DENT. REPAIRED. (LP 0976387)SDR DALA2019030901719Strap · not reportedRT STA 955 FAIL SAFE STRAP REPAIRED.SDR DALA2019030501457Seat Track · corrodedCORROSION LEVEL: 2 SEAT TRACK- CORROSION FOUND ON CABIN SEAT TRACK RBL 88.5, STA 1098 TO STA 1208 FOUND 5 LOCATON WITHIN OF LIMIT. STA1131 IS 0.043". STA1197 IS 0.037" FOUND 2 LOCATION OUT OF LIMITS. REPAIRED. (LP 0970460)SDR DALA2019030501456Skin · dentedFOUND RT WING L/E SLAT NR 10 UPPER SKIN. REPAIRED PER SRM 57-43-02. (LP 0970348).SDR DALA2019030501455Skin · dentedFOUND RT WING L/E SLAT NR 12 UPPER SKIN 01 EA DENT. REPAIRED PER SRM 57-43-02. (LP 0970340)SDR DALA2019030601629Structure · corrodedCORROSION LEVEL: 2 FLOOR STRUCTURE FOUND CORRODED ON STA 917, LBL11. UNDER MID LAV AND REPAIRED. (LP 0970645)SDR DALA2019030701718Skin · corrodedCORROSION LEVEL: 2 CONTROL BAY ACCESS DOOR INTERIOR SURFACE FOUND CORROSION. REPLACED THE CORRODED SKIN. (LP 0973659)SDR DALA2019030501458Seat Track · corrodedCORROSION LEVEL: 2 SEAT TRACK - CORROSION FOUND ON SEAT TRAK RBL 88.5, FROM STA 1208 TO STA 1428 THE CLEANUP DEPTH IN BOTTOM OF TRACK:STA1301 IS 0.043" STA 1329 IS 0.064" FOUD OUT OF LIMIT. C/W ERA 575499-14. (LP 0970475)SDR DALA2018092105698Connector · looseEMERGENCY CEILING LIGHTS ABOVE ROW 3 RIGHT AISLE ARE INOPERATIVE. FOUND LOOSE CONNECTION AND SECURED MCO/PLACARD REMOVED.SDR DALA201805143300Battery Pack · inoperativeEMERGENCY LIGHTS AT ROWS 32 - 39 WILL NOT ILLUMINATED. REPLACED THE BATTERY PACK AT SEAT 39R.SDR DALA2018022601213Structure · crackedFOUND A CRACK, APPROX 4 INCHES AT SECTION 48 RT SIDE FWD OF HORIZONTAL STAB. BETWEEN BS 1627 TO 1630. COMPLIED WITH SRM 53-00-01.SDR DALA2017122008748Lens · damagedEMERGENCY EXIT COVER DIFFUSER LENS DAMAGED AT ROW 41. REPLACED SIGN SYSTEM OPERATION IS NORMAL.SDR DALA2017121308590Engine · flamed out#2 ENGINE FLAMED OUT. TOWER AND OTHER AIRCRAFT REPORTED SMOKE FROM RT ENGINE. NO FIRE WARNING. REPLACED #2 ENGINE ON LP 0334128SDR DALA2017122608930Engine · damagedNR 2 ENGINE FAILED A BOROSCOPE INSPECTION. THE ENGINE WAS CHANGED IAW ERA 564039-14.SDR DALA2017082506387Structure · gougedON ARRIVAL, FOUND A GOUGE AT LOWER FORWARD CORNER OF AFT CARGO DOOR. MEASURING 3/16" DEEP AND 1/4" LENGTH. COMPLIED WITH A TIME LIMITED REPAIR IAW ERA 561360-14.SDR DALA2016050303647Battery Pack · inoperativeWHILE WORKING PDC SQUIB TEST FOR LT AND RT ESCAPE LIGHT WILL NOT TEST. MAINTENANCE REPLACED BATTERY PACK AND CHARGER. SYS OPERATION IS NORMAL.SDR DALA2016030301609Battery Pack · dischargedEMERGENCY LIGHTS AT SEATS 6-9 ARE INOPERATIVE. MAINTENENACE REPLACED THE BATTERY PACK CHARGER. SYSTEM OPS ARE NORMAL.SDR DALA2015122907815Battery Pack · inoperativeEMERGENCY EXIT LIGHTS AT SEATS 5-10 AND RT ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK ABOVE SEAT 6. SYSTEM OPERATION IS NORMAL.SDR DALA2014110906075Connector · unsecureDURING ETOPS SERVICE CHECK, TEST OF THE EMERGENCY ESCAPE SQUIBS DOES NOT WORK. FOUND ELECTRICAL CONNECTOR LOOSE. RESECURED, TESTED OK.SDR DALA14008221708Battery Pack · inoperativeEMERGENCY ESCAPE TEST 1 SLIDE L/R AND TEST 2 SPOILER L/R WILL NOT TEST. . REPLACED LT & RT OVERWING SLIDE BATTERIES AND CHARGERS IAW AMM 25-65. IAW AMM 25-65. FOUND REPLACED BATTERIES TO BE FAULTY ALSO. R & R BATTERIES AGAIN. CHECKED NORMAL.SDR DALA13069991708Battery Pack · inoperativeEMERGENCY ESCAPE SLIDE SQUIBS WILL NOT TEST. REPLACED LT SIDE OVERWING ESCAPE BATTERY AND CHARGER IAW AMM 25-65, TESTED GOOD.SDR DALA13055791708Battery · inoperativeSQUIB TEST PANEL EMERGENCY LT & RT ESCAPE LIGHTS WOULD NOT TEST. FOUND M961 SQUIB SLIDE BATTERY PACK HAS LOW VOLTAGE. R & R BATTERY AND CHARGER IAW AMM 767 25-61. OPS CHECKED OK, PRESS TO TEST OK. OK FOR SERVICE.SDR DALA13055801708Ground Stud · looseEMERGENCY CEILING LIGHT, POS 40 GF IS INOPERATIVE. FWD TO MCO IAW MEL 33-51-01A. FOUND GROUND STUD LOOSE, SECURED GROUND STUD IAW STANDARD PRACTICE 20-20, OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13045321708Battery Pack · inoperativeOVERWING SQUIB SLIDE TEST LT FAILED. CHANGED BATTERY OF THE EMERGENCY BATTERY PACK IAW TASK 25- 65-17, OK FOR SERVICE.SDR DALA13040991708Battery Pack · inoperativeON PDC SQUIB TEST EMERGENCY ESCAPE LIGHT FAILED. REPLACED LT OVERWING SLIDE SQUIB BATTERY CHARGER AND BATTERY PACK IAW AMM 25-65. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA13027411708Charger · inoperativeLEFT SIDE SQUIB NOT TESTING IAW FIM 25-65. FOUND BATTERY PACK CHARGER INOPERATIVE. R & R BATTERY CHARGER IAW AMM 25-65. OPS CHECKED GOOD.SDR DALA13018031708Battery Pack · inoperativeOVERWING SLIDE/SPOILER SQUIB TEST INOPERATIVE. REPLACED BATTERY IN LT POWER SUPPLY. OPS NORMAL