N18119
Service difficulty reports · 98
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N18119' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N18119' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017112004166Girt Bar · out of positionL4 DOOR SLIDE LIGHT INOPERATIVE. CLEANED, LUBED, AND REPOSITIONED GIRT BAR ASSY. DOOR ARMS AND DISARMS NORMALLY. OPS CHECKED GOOD.SDR CALA2017111704063O-Ring · leakingFUEL LEAK LEFT ENGINE DURING FLT. 3500 LBS DIFFERENCE BETWEEN FMC AND CALC FUEL. VISUALLY CONFIRMED THE LEAK. EMERGENCY DECLARED. MOTORED ENGINE AND FOUND SIGNIFICANT FUEL LEAK COMING FROM HIGH PRESSURE FUEL PUMP OUTLET SUPPLY LINE TO FUEL CONTROL GOVENOR, SDR CALA2017103003863Light · defective4R SLIDE PRESS LT FLASHING. REMOVED AND REPLACED LAMP AT 4R SLIDE LIGHT REF AMM 33-51-06-962 OPS CHECKS GOOD.SDR CALA2017102703817Lamp · inoperativeEMERGENCY LIGHTS ARMED LIGHT RT SIDE INOPERATIVE ON THE OVERHEAD. REPLACED THE LAMPS, TESTED OK.SDR CALA2017102003716Cover · out of positionEMERGENCY LIGHTS COVER SWITCH DOES NOT ARM EMERGENCY LIGHTS WHEN CLOSED REPOSITION EMERGENCY LIGHT SWITCH COVER. OPS CK GOOD.SDR CALA2017092203286Latch · looseL4 DOOR SLIDE COVER LATCH IS LOOSE. SECURED THE LATCH STRAP IAW AMM 25-66-01SDR CALA2017090803061Girt Bar · lack of lubeF/A REPORTED AFTER PUSH BACK, THE L4 DOOR SLIDE LIGHT DID NOT ILLUMINATE. REMOVED THE SLIDE COVER, LUBRICATED AND CHECKED ADJUSTMENT OF GIRT BAR SLIDER IAW AMM 52-11-25-825-001 AND OPS CHECKED WITH GIRT BAR MECHANISIM IAW AMM 52-11-25-735-024. ALL OPS CHECKSDR CALA2017082802933Proximity Switch · dirty3R SLIDE ARM LITE FLICKERS. CLEANED DEBRIS FROM PROX SWITCH, OPS CHECK GOOD.SDR CALA2017082502844Trigger · out of adjustSLIDE LIGHT ON THE R1 DOOR HAS BEEN INTERMITTENT THE LAST 2 HOURS. CYCLES ON/OFF EVERY 20 MINUTES. ADJUSTED PASSENGER DOOR ESCAPE SLIDE TRIGGER MECHANISM IAW AMM 52-11-32. OPS CHECKED GOOD.SDR CALA2017062501978Oven · odorGALLEYS GALLEY G4A OVEN AUTO STOPS DURING COOKING, FAULT 6 DISPLAYED, FAINT ELECTRICAL ODOR. FOUND NR 1 OVEN INOPERATIVE. REMOVED AND REPLACED THE OVEN, OPS CHECKED GOOD IAW AMM 25-34-00SDR CALA2017061701859Switch · dirtyR1 DOOR ARM LIGHT NOT ILLUMINATING WITH DOOR CLOSED. CLEANED SLIDE SWITCH IAW SWP 20-60-01. OPS CHECKED GOOD.SDR CALA2017051201343Frame · dentedFWD CARGO FRAME HAS THREE DENTS BS 660, STRINGERS 22 - 25L REPAIRED THE FRAME IAW IAW 2012210-17.SDR CALA2017051201342Skin · dentedLEFT HORIZONTAL STABILIZER UPPER SURFACE DENTED LOCATED APPROXIMATELY 40 INCHES FROM FUSELAGE AND 21 INCHES FROM FRONT SPAR. FOUND TO BE OUT OF LIMITS IAW SRM 55-10-01 ALLOWABLE DAMAGE . CLEANED AND REPAIRED THE AREA IAW SRM 51-70-10.SDR CALA2017051201341Frame · dentedFWD CARGO FRAME DENTED BS 660, STRINGER 23R . REMOVED THE DENT AND REPAIRED THE FRAME IAW SRM 53-00-07, FIGURE 201, SHUT 4.SDR CALA2017050101202Frame · dentedAFT CARGO FRAME BS 1480 BETWEEN STRINGERS 23 AND 24L WAS FOUND DENTED. REPAIRED IAW SRM 53-00-07, REPAIR 5.SDR CALA2017081402650Structure · corrodedBS 1140 + 6, RBL 9 UPPER WHEELWELL SURFACE HAS A DOUBLER WITH CORROSION. REMOVED AND INSTALLED NEW DOUBLER IAW SRM 57-40-05 , DRAWING 140N3441, REV J, SRM 57-40-02, AMM 20-10-09-404-006, AMM 29-11-00-796-030, AND DRAWING 144N8006.SDR CALA2017031000559Oven · smokeGALLEYS GALLEY G1A - OVEN AT GALLEY DEFECTIVE (DESCRIBE DEFECT) OVEN 204 SMOKING AND SPARKING WHEN IN USE. REPLACED GALLEY OVEN G1A WITH SERVICEABLE UNIT OVEN OPS CKS GOOD.SDR CALA2017030400523Lamp · inoperativeLEFT AFT OVERWING EMERGENCY EXIT EXT SLIDE LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-06. OPS CHECKED NORMAL.SDR CALA2017030400522Light · inoperativeL4 DOOR EXT SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHT ASSY IAW AMM 33-51-06. OPS CHECKED NORMAL.SDR CALA2017013000199Oven · dirtyFWD GALLEY OVEN BELOW POS205 SMOKES DURING OPERATION. RECOMMEND CLEANING. CLEANED OVEN NO SMOKE NOTED DURING OPERATION AT THIS TIMESDR CALA2016111100875Socket · not seatedSLIDE LIGHT DID NOT ILLUMINATE WHEN ARMING. 1R RESEATED LIGHT SOCKET OPS CHECK GOOD.SDR CALA2015071500572Unknown · engagedLOW SPEED ABORT AROUND 80 KTS FOR RT THROTTLE. AFTER AUTO THROTTLE ENGAGED RT THROTTLE STOPPED HALFWAY & WOULD NOT MOVE. DISENGAGED AUTO THROTTLE, STILL WOULD NOT MOVE FWD, RT THROTTLE RETURNED TO IDLE. FOUND NR 2 ENG PART POWER BAULK ENGAGED. STOWED BAULKSDR CALA2015040600253Slide · unwanted deployWHILE FACILITATING OTHER MX, L4 DOOR ESCAPE SLIDE INADVERTENTLY DEPLOYED. R & R L4 DOOR SLIDE IAW AMM 25-66-01. ROTABLE PARTS CHANGE WAS INDICATED. TT 1697700, SN OFF 00332 SLIDE, 757-200, OFF 19-2567-9-0001 0332 ON 19-2567-9-0001 0559.SDR CALA2015040600240Bottle · malfunctionedREFERENCE LOG PAGE 8170488, L4 DOOR ASSIST BOTTLE NOT FIRING, THIS LOG PAGE FOR SDR REPORTING ONLY. R & R L4 EMER POWER RESERVOIR & DOOR ASSIST IAW AMM 52-11-30. SEE LOG PAGE 8170488 FOR ADJUSTMENT OF DOOR ASSIST FIRE. MECH ROTABLE PARTS CHANGE WAS INDICATESDR CALA2014052700679Frame · crackedFRAME CRACKED AT STATION 1580, AT PSU SUPPORT INBD FASTENER. INSTALL FRAME REPAIR AT STATION 1580 BETWEEN STRINGER 6R TO 29R. CUT OUT CRACKED 4 INCHES. FABRICATED REPAIR ANGLES FROM 7075 0.063. SIZE 18 X 4, NO CRACKS NOTED. REINSTALLED OVERHEAD BIN IAW SRMSDR CALA2014052700678Intercostal · crackedFORWARD CARGO LOWER SILL INTERCOSTAL CRACKED LOCATED IN BS 573 RBL 17 - 25. R & R INTERCOSTAL AT FWD CARGO LOWER SILL AREA BS 573 BETWEEN RBL 17 - 25 IAW DWG NR 143N8549 & SRM 51-40-02.SDR CALA2014052700677Door Sill · corrodedFORWARD CARGO LOWER SILL CORRODED AT CTR SECTION. R & R FWD CARGO SILL CHORD IAW 2007145-60 & ECRA 5311-01690.SDR CALA2014052700660Light · brokenSUPPORT TASK EPL LIGHT ASSEMBLY BROKEN AT SEAT 31A. R & R EPL LIGHT ASSEMBLY AT SEAT 31A IAW AMM 33 -51-11, TESTED NORMAL.SDR CALA2014052700659Switch · defectiveFWD CABIN AREA, AISLE, SEATS & DOOR EMERGENCY SIGNS & LIGHTS INOPERATIVE. R & R EMERGENCY LIGHT TEST SW S10292, PERFORMED OPERATIONS CHECK FWD CABIN AREA, AISLE, SEATS DOOR EMERGENCY SIGNS & LIGHT FOUND NORMAL IAW AMM 33-51-00 & WD 33-51-12.SDR CALA2014052300651Web · corrodedCORROSION AT MAIN DECK FLOOR AFT GALLEY STATION 1720 UNDER SCUPPER, BL0 TO RBL 70, SDR FORM ATTACHED. REMOVED CORROSION ON STATION 1720 BETWEEN RBL 30" & LBL 30" IAW SRM 51-40-02. FOUND OUT OF LIMITS & INSTALLED REPAIR SPLICES & A WEB REPAIR AT MAIN DECK AFTSDR CALA2014052300646Frame · crackedFRAME CRACKED AT INBD FASTENER HOLE FOR PSU SUPPORT BRACKET AT STATION 760, LT SIDE, BETWEEN STRINGER 8 & 9. REPAIR CARRIED OUT IAW SRM 53-00-07, REPAIR-1, CAT-B.SDR CALA2014052300645Frame · crackedFRAME CRACKED AT INBD FASTENER HOLE FOR PSU BRACKET AT STATION 760, RT SIDE, BETWEEN STRINGER 8 & 9. REPAIR CARRIED OUT IAW SRM 53-00-07, REPAIR-1, CAT-B.SDR CALA2014051300589Support · corrodedR2 DOOR THRESHOLD WATER TRAY SUPPORT HAS CORROSION AT FWD, AFT END CTR AREA. SDR FORMS ATTACHED. REMOVED & REPLACED CHORD BETWEEN STATION 664.85 THRU STATION 755.12, RBL 64 IAW DRWG 143N8322 & SRM 51-40-02.SDR CALA2014051200580Crease Beam · corrodedB757-53-3-0479 STATION 301 RBL 64 CABIN FLOOR CREASE BEAM CORRODED. SDR FORM ATTACHED. R & R CABIN FLOOR CREASE BEAM ANGLE IAW DWG 141N8422 & SRM 51-40-02, AT RBL 64 & BETWEEN STATION 301 - 377. FORM 44-0008 PGS 1 & STEPS 6.SDR CALA2013091600678Fuse · blownEMERGENCY AISLE LIGHTS FLOOR INOPERATIVE ROWS 20-30. TROUBLE SHOT IAW WDM 33-51-22. FOUND A BLOWN FUSE IN EMERGENCY LIGHTS BATTERY PACK M10699, REPLACED. SYSTEM GROUND CHECKED GOOD IAW MM 33-51-07.SDR CALA2012020200066Gcu · faultyOUT OF 7000 ON CLIMBOUT EICS YAW DAMPNER LIGHT FLICKERED ALONG WITH FLIGHT INSTRUMENTS. RESET FLIGHT AIRECATICS. CONTINUED WITH CLIMBOUT THE YAW DAMPNER WAS JERKING THE RUDDER AND ATTITUDE AND NAVIGATION SCREENS FLICKERED ON AND OFF CHANGED ATA 2400 TO 2420.SDR CALA2011010400006Battery · dischargedONE AFT GALLEY EMERGENCY FLASHLIGHT IND. LIGHT DOES NOT BLINK. REPLACED BATTERY IN FLASHLIGHT. OPS CHECK`S NORMAL. SECURED LIGHT IN HOLDER.SDR CALA2011052000374Gcu · malfunctionedDURING CLIMBOUT LEVEL AT 10000FT 300KTS CAPTS EFIS SCREENS BEGAN TO FLICKER ACCOMPANIED BY A CASCADE OF LIGHTS EICAS MSGS AND THEN A STRONG ELECTRICAL BURNING SMELL/SMOKE STRONGEST ON CAPTS SIDE. OVERWEIGHT APPCH AND TOUCHDOWN. BRAKES OK CREW EXPERIENCED A LSDR CALA2009121600721Charger · inoperativeROW 21 LT OVERHEAD BULKHEAD EMERGENCY LIGHT INOPERATIVE. FOUND BATTERY CHARGER (POWER SUPPLY) DEFECTIVE, REMOVED AND REPLACED, OPS CHECK NORMAL, REF AMM 33-51-07.SDR CALA2009121600722Charger · inoperativeEMERGENCY LIGHTS INOPERATIVE AT L1 MAIN DOOR EXTERIOR. PATH LIGHTS BUSINESS 1ST, BULL NOSE 1, 3 AND 4AB. REPLACED BATTERY PACK AND PWR SUPPLY, OPS CHECKS GOOD AT EMERGENCY LIGHTS AS NOTED ABOVE. PWR SUPPLY REPLACED M731 PER W/D 33-51-01.SDR CALA0800741Crease Beam · corrodedRIGHT SIDE OF FLOOR STURCTURE CREASE BEAM LOCATED AT STATION 1200 TO 1320 CORRODED IN SEVERAL SPOTS. REMOVED DAMAGED SECTION AND FABRICATED NEW INBOARD CHORD SECTION OF CREASE BEAM FROM STATION 1180 TO 1310, PERFORMED REPAIR TO RIGHT SIDE FLOOR STRUCTURE INBOSDR CALA0800714Floor Support · corrodedCORROSION AT FLOOR SUPPORT STA 333, LBL-20. REMOVED AND REPLACED FLOOR SUPPORT FITTING AT STA 333, LBL-20. INSTALLED NEW FASTENERS, REF SRM 51-40-02, REF BOEING DWG 141N5170.SDR CALA0300420Oven · inoperativeTHE FIRST CLASS GALLEY OVEN #204 BEGAN TO PRODUCE AN ELECTRICAL ODOR WHILE IN ROUTE TO ANC. THE OVEN SHUTDOWN AUTOMATICALLY AND WOULD NOT RESET. THE FLIGHT CONTINUED TO ANC WITHOUT FURTHER INCIDENT. THE OVEN WAS PLACARDED INOPERATIVE. THE OVEN WAS REMOVED AND SDR CALA0300218Skin · puncturedPUNCTURE DAMAGE TO INNER SKIN OF L4 DOOR. REPAIR PUNCTURE DAMAGE PER EC/RA 5210-01692.SDR CALA9800473Actuator · inoperativeTHE EICAS GEAR DISAGREE AND GEAR AMBER LIGHT ILLUMINATED AFTER GEAR RETRACTION WITH GEAR HANDLE IN THE UP POSITION. MOVING THE GEAR HANDLE TO THE OFF POSITION REMOVED BOTH WARNINGS. NOSE GEAR RETRACTION SEEMED LONGER THAN NORMAL. THE FLIGHT CONTINUED TO EWRSDR CALA9800270Bottle · low pressureINSPECTION FOUND THE L-2 DOOR ASSIST BOTTLE PRESSURE LOW. THE L-2 DOOR ASSIST BOTTLE WAS REMOVED AND REPLACED IAW MM 52-11-30.SDR CALA9701640Actuator · inoperativeWHEN FLAP/SLAT HANDLE WAS PLACED TO 1 DEGREE, THE LEADING EDGE SLATS DISAGREE LIGHT ILLUMINATED AND FLAP INDICATOR SHOWED .5 DEGREE. ALTERNATE FLAP SYSTEM WAS USED AND THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND OVERLOAD INDICATOR ON NR 3 SLAT TRSDR CALA9701398Actuator · inoperativeWHEN GEAR HANDLE WAS MOVED TO UP AFTER TAKEOFF, THE AMBER DOORS LIGHTS AND AMBER GEAR LIGHT REMAINED ILLUMINATED AND ALL GREEN LIGHTS WERE OUT. THE EICAS MESSAGE GEAR DISAGREE ALSO APPEARED. ALL LIGHTS WENT OUT AFTER APPROXIMATELY 45 SECONDS. MAINTENANCE FO