What was found
FRAME CRACKED AT STATION 1580, AT PSU SUPPORT INBD FASTENER. INSTALL FRAME REPAIR AT STATION 1580 BETWEEN STRINGER 6R TO 29R. CUT OUT CRACKED 4 INCHES. FABRICATED REPAIR ANGLES FROM 7075 0.063. SIZE 18 X 4, NO CRACKS NOTED. REINSTALLED OVERHEAD BIN IAW SRM 53-00-07, 51-10-02, AMM 51-21-04, 25-28-02-004-001, NDT51-10-16P6 & 51-00-19.