N192DN
Service difficulty reports · 182
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N192DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N192DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018102806395B-Nut · looseFLIGHT 166 SIN-NRT, DIVERTED TO MNL DUE TO CREW O2 PRESSURE AT 0 PSI. MAINTENANCE FOUND B NUT LOOSE AT SECOND OBS SEAT O2 BOX ON BACK OF BOX. TIGHTENED SAME AND PERFORMED LEAK. SYSTEM CHECKS NORMAL.SDR DALA2018071904578Control Panel · malfunctionedDURING RIGHT OFF WING SLIDE DEPLOY TEST, SLIDE FAILED TO DEPLOY WHEN THE RIGHT AFT OVER WING WAS REMOVED, OPERATED NORMAL WHEN FORWARD EXIT WAS REMOVED. REPLACED ARM SWITCH PANEL. SYSTEM OPERATION IS NORMAL.SDR DALA2018071804577Slide · deployedRIGHT OFF WING SLIDE DEPLOYED. REPLACED RIGHT SPOILER OVERRIDE BLOWN DOWN ACTUATOR, RIGHT FORWARD AND AFT DOOR OPEN ACTUATORS AND RIGHT DOOR RELEASE ACTUATOR. SYSTEM OPERATION IS NORMAL.SDR DALA2018052503579Skin · cracked3/4 INCH LONG CRACK NOTED IN AFT FUSELAGE SKIN, STRINGER 13AL, BS 1674. REPAIRED IAW SRM 53-80-01.SDR DALA2018052503578Skin · crackedONE INCH LONG CRACK NOTED IN THE AFT FUSELAGE SKIN, STRINGER 13AR, BS 1674. REMOVED THE DAMAGE IAW SRM 53-80-01.SDR DALA2018030501430Power Supply · inoperativeDURING A SERVICE CHECK, FOUND THREE EXTERIOR EMERGENCY LIGHTS INOPERATIVE LEFT SIDE OF AFT WING. REPLACED THE POWER SUPPLY M728. SYSTEM OPS NORMAL.SDR DALA2018011500281Fuse · failedDURING A SERVICE CHECK, FOUND EMERGENCY LIGHTS CABIN RT SIDE ROWS 4, 5, & 6 INOPERATIVE. FOUND THE FUSE IN BATTERY PACK BAD AND REPLACED. SYSTEM OPS NORMAL.SDR DALA2017112708315Slide · unwanted deployINADVERTENT SLIDE DEPLOYMENT DOOR L1. REPLACED DOOR SLIDE.SDR DALA2017112708301Wire Splice · brokenEMERGENCY LIGHT OUT AT MID FWD LAV. FOUND WIRE SPLICE BROKEN AND REPAIRED.SDR DALA2017081906339Actuator · failedON FINAL APPROACH, EICAS ANNUNCIATED C HYDRAULIC SYSTEM QUANTITY, QUICKLY FOLLOWED BY C HYDRAULIC PRESSURE. PERFORMED A GO AROUND, ACCOMPLISHED HYDRAULIC, FLAP AND LANDING GEAR PROCEDURES. LANDED FLAPS 20. MAINTENANCE REPLACED INBOARD SOILER ACTUATOR NR 5. SDR DALA2017020701028Sign · inoperativeCOCKPIT EXIT SIGN DOES NOT ILLUMINATED WITH EMERGENCY LIGHT SWITCH SET TO ON, AND BATTERIES. SYSTEM OPERATION IS NORMAL.SDR DALA2016021601131Bulb · inoperativeEXTERIOR EMERGENCY LIGHTS ARE INOPERATIVE AT 2ND AND POSITION FROM AFT ON BOTH SIDES. MAINTENANCE REPLACED BULB FOR ACFT LT SIDE AND POWER SUPPLY WITH BATTERY FOR RT SIDE. SYSTEM OPERATION IS NORMAL.SDR DALA2015101906316Connector · unsecureSEAT 31A EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE SECURED SEAT CONNECTOR AT 31A, SYSTEM OPS NORMAL.SDR DALA2015100706008Charger · inoperativeAFT LEFT EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE CHARGER AT ROW 39FG. SYSTEM OPS NORMAL.SDR DALA2015082005239Battery Pack · inoperativeDURING PDC INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE FROM ROW 32 UP TO LAST. MAINTENANCE REPLACED BATTERY PACK AND SLADE CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2015072704659Charger · inoperativeON SERVICE CHECK, FOUND EMERGENCY LIGHTS FROM SEATS 31 INOPERATIVE. MAINTENENCE REPLACED THE BATTERY AND CHARGER. SYSTEM OPS NORMAL.SDR DALA2015072104575Light · inoperativeEMERGENCY LIGHTS AT SEAT 1A ARE INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA2015040802856Beam · corrodedCABIN RT UPPER MAIN SILL BEAM WEB FOUND CORROSION AT RBL 93 BETWEEN STA 1334 AND STA 1347. REPLACED IAW SRM 51-40-02.SDR DALA2015040102621Door Frame · crackedAFT CARGO BAY DOOR CUTOUT AT BS 1351, S25 - 26R FRAME FOUND CRACKED. FRAME REPAIRED IAW SRM 53-00-07. LP 1885744SDR DALA2015033102618Stringer Clip · corrodedRT CABIN STRINGER CLIP FOUND CORROSION AT BS 933 AND S-19R. STRINGER REPLACED. LP 1883903SDR DALA2015033102620Roller Tray · corrodedFWD CARGO, CENTER LT & RT ROLLER TRAY AT STA 654+22, FOUND CORROSION, CLEANED UP AND REPAIRED.
SDR DALA2015033102619Seat Track · corrodedLT CABIN SEAT TRACK FOUND CORROSION LBL 88.5 BETWEEN BS 752 AND BS 1097. DAMAGED SEAT TRACK REPAIRED.SDR DALA2015033002615Intercostal · corrodedRT CABIN INTERCOSTAL FOUND CORROSION AT STA 790 AND S-18R CORRODED. THE DAMAGE REPLACED. LP 1882776SDR DALA2015033002617Failsafe · corrodedCABIN LT AFT EMERGENCY EXIT HATCH FAIL SAFE STRAP FOUND CORROSION AT WINDOW CUTOUT FWD EDGE. FAIL SAFE STRAP REPLACED.SDR DALA2015032702613Seat Track · corrodedSEAT TRACK FOUND CORRDED AT RBL 88.5 BETWEEN BS 1209 AND 1427 AND FOUND OUT OF LIMITS IAW SRM 53-00-52. SEAT TRACK REPLACED IAW SRM 51-40-02.SDR DALA2015033002616Truss · corrodedCABIN TRUSS FOUND CORROSION AT S-20R AND STA 1197+10 CORRODED. TRUSS REPLACED. LP 1882785SDR DALA2015032702614Truss · corrodedTRUSS FOUND CORRODED AT BS 1144 AND S20R CORRODED. TRUSS REPLACED.SDR DALA14015930192Terminal · looseEXTERIOR EMERGENCY LIGHT AT R1 DOOR IS INOPERATIVE. MAINTENENANCE FOUND OPEN WIRE AND GROUND TERMINAL LOOSE AND TIGHTENED. SYSTEM OPERATION IS NORMAL.SDR DALA14011150192Power Supply · inoperativeEXTERIOR EMERGENCY LIGHT INOPERATIVE, LEFT AFT AREA. MAINTENANCE REPLACED THE POWER SUPPLY AT SEAT 38A. SYS OPERATION IS NORMAL.SDR DALA13022920192Bulb · looseOVERHEAD CEILING EMERGENCY LIGHT AT 25-26F INOPERATIVE. MX SECURED LAMP IN SOCKET. SYS OPS NORMAL.SDR DALA13020550192Light · inoperativeEXIT SIGNS AT BS 899 INOPERATIVE. REPAIRED IAW VA 85505MA.SDR DALA1303790192Battery Pack · inoperativeON WALK AROUND FOUND O/W ESCAPE AFT EMERGENCY LIGHTS INOPERATIVE. MX REPLACED M738 BATTERY PACK. SYS OPS IS NORMAL.SDR DALA1301710192Wire · unsecureEMERGENCY LIGHTS AT ROW 32AB ARE INOPERATIVE. MX SECURE THE WIRE HARNESS PLUG. SYSTEM OPS IS NORMAL.SDR DALA1256350192Connector · looseFOUND 39B EMERGENCY AISLE ESCAPE LIGHT INOPERATIVE. FOUND LOOSE CONNECTOR AT UNDER THE SEAT SECURED LIGHT CHECK OK. ACFT OK FOR SERVICE.SDR DALA1204010192Strap · crackedHMV2 FAIL SAFE STRAP CRACKED STA 995 LT SIDE OPN 8701AD. REPAIR PER ERA 499083-14AD REV 0.SDR DALA1201840192Strap · crackedFAIL SAFE STRAP-INSP (OPN 8701AD) ULTRASONIC INSP CARRIED OUT ON STA 955 FAIL SAFE STRAP (LT SIDE) & FOUND CRACK INDICATION NRC # 0015 RAISED TO REMOVED AFFECTED FASTENER & CONFIRM CRACK INDICATION AT 2 O`CLOCK & 8 O`CLOCK POSITION. BS 955 REAR SPAR BULKHEAD SDR DALA1168860192Unknown · malfunctionedIFE DISPLAY UNIT SEAT 5A STARTED TO SMOKE BRIEFLY ACRID SMELL UNIT WAS SHUTDOWN NO FURTHER INDICATIONS. REMAINDER OF FLIGHT UNEVENTFUL. FAINT SMELL DETECTED INSP ALL CONN TO SDU. SEAB AND SPM FOUND NO VISIBLE DAMAGE. SDU AND SEB WERE REPLACED PER OCC REQUESDR DALA1164030192Light · inoperativeCEILING EMERGENCY LIGHT ABOVE SEAT 2B INOPERATIVE. REPLACED CEILING LIGHT ASSEMBLY PER AMM 33-51-05. OPS CHECKS NORMAL.SDR DALA1501040192Fairing · crackedNR 3 AFT FLAP LINKAGE FAIRING CRACKED, AT 4 O'CLOCK POS .75 L/E. CARRIED OUT PERMANENT REPAIR SRM 51-70-17, PARA 4A, REV 91-03 AND PAINTED IAW SRM 51-2-01, REV 91.03.SDR DALA1156810192Wire Harness · brokenEMERGENCY LIGHT AT SEAT 40GK INOP. FOUND WIRE HARNESS BROKEN. REPLACED SAME. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR DALA1155720192Connector · looseEMERGENCY LIGHTS IN ROW 40GF, 37GF AND 25AB ARE INOPERATIVE. MAINTENANCE REPLACED LOOSE CONNECTORS ON 40GF, 37GF AND 25AB. SYSTEM OPERATION IS NORMAL.SDR DALA1141320192Wire · brokenMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTING AT SEATS 22FG INOPERATIVE. MAINTENANCE FOUND BROKEN WIRE AND REPAIRED. OPERATIONAL CHECK WAS NORMAL.SDR DALA1135340192Battery Pack · inoperativeMAINTENANCE FOUND EMERGENCY LIGHT OVER COCKPIT DOOR INOPERATIVE. MAINTENANCE REPLACED BATTERIES. LIGHT OPERATIONAL CHECK WAS OK.SDR DALA1112670192Light · inoperativeEMERGENCY LIGHTS AT SEAT 25G ARE INOPERATIVE. MAINTENANCE WAS UNABLE TO FIND SHORT AND DEFERRED TO MEL 33-51-03A.SDR DL76L101216Oil System · low pressureAT CRUSE FL 310, LOST ALL OIL QTY AND PRESS DROPPED, ENGINE RAN FOR 5 MIN WITH 0 OIL QUANTITY AT 0 THEN SHUT ENGINE DOWN. PRESSURE WAS 53 WHEN SHUTDOWN. 25 MINUTE WINDMILL. ENGINE VIBS WERE NORMAL. MX IN PROGRESS. ETOPS CATEGORY 'A': ANY IN-FLIGHT SHUTDOWN.SDR DL76L092027Outflow Valve · inoperativeUNABLE TO CONTROL CABIN PRESSURIZATION. AUTO PRESS CONT 1 AND 2 FAIL ALSO UNABLE TO CONTROL MANUALLY. DIVERTED, FOUND POTABLE WATER LEAKING AND ICE ACCUMULATION AROUND OUTFLOW VALVE. REMOVED ICE. AUTO 1 RESET GOOD/MAN CONT GOOD. AUTO 2 RESET NO GOOD. A/C PRESDR DL76L090448Frame · crackedDURING CURRENT HMV, LT AND RT 903.5 FRAME CHORDS WERE FOUND CRACKED IN TYPICAL LOCATIONS. MANUFACTURER APPROVED REPAIRS INSTALLED, AND ARE DOCUMENTED IN 473030-14SDR DL76L090254Terminal · meltedBURNING ODOR COMING FROM CABIN AROUND DOOR 1L. NOTED OUTLET FOR DOOR 1L BLACK. PULLED CB AND REMOVED OUTLET. FOUND OUTLET MELTED. REMOVED TERMINALS AND INSTALLED INSULATION PER SWPM 20-10-11, CB P6 L24 PULLED AND COLLARED. FWD TO MCO.SDR DL76L090122Switch · malfunctionedFLAP/SLAT ELEC STATUS EICAS MESSAGE WHEN MOVING FLAP HANDLE FROM 1 TO 5 DEGREES. FOUND S 846 INTERMITTENTLY STICKING IN HIGH. SWAPPED W/C2 E PUMP SWITCH S34 LEAK CK OK FLAP/SLAT ELEC CKS GOOD MFR P NBR S271T452-1 S846 SN NOW U01222 S34 SN NOW U 01185 HIGH F SDR DL76L081700Compressor · odorPOTABLE WATER COMPRESSOR INOP AND EMITTING ELEC SMELL. FOUND COMPRESSOR WITH BURNT SMELL. DISCONNECTED AND STOWED CONNECTOR. PULLED/SECURED C/B H6 ON P33. FWD TO MCO PLAC REF MEL 38-10-01A SMELL OCCURRED AT GATE WITH PAX ONBOARD. REMOVED AND REPLACED POTA