N210UA
Service difficulty reports · 205
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010051001584Eec · faultyRT ENGINE DID NOT SHUTDOWN WITH FUEL-SHUTOFF TO OFF POSITION. RT ENGINE SHUTDOWN BY FIRE HANDLE. REPLACED EEC AND ENG RELAY UNIT, NO HELP. DUE TO RECURRING PROBLEMS WITH NR 2 ENG SLOW RESPONSE TO FUEL CUT OFF WITH RELAY K76207 REPLACED AND STILL INCONSISTENSDR UALA2010050501510Controller · faultedRT OVERHEAD BUSS CONTROLLER IS FAULTY. CONTROLLER IS INADEQUATE. NEEDS TO BE REPLACED. REPLACED RIGHT OVERHEAD BUSS CONTROLLER. OPS GOOD.SDR UALA2010050401501Circuit Card · faultyBLEED LOOP 2 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR RT DUCT LEAK OVERHEAT DETECTION SYS (DLODS) CARD. STATUS MSG-2631142 ACTIVE ER HARD MSG-2631142 ACTIVE ER HARD MSG-2631132 INACTIVE ER INTER. AHM FAULTING BLD BODY LP-2 ZONE 13,14 IS OPEN-INTMTNT-CRSDR UALA2010050401504Fmu · faultyCREW REPORTS RT ENGINE TOOK APPROX 1 MINUTE TO SHUTDOWN AFTER FUEL CUT-OFF SW MOVED TO CUT-OFF. MSG 73-60212 AND 28-11006 ON EXISTING FAULTS. REPLACED FMU IAW AMM. PERFORMED LEAK CHECK OF NR 2 ENG FMU ON ACCT OF FMU CHANGE. NO LEAKS NOTED. RAN ENG IAW TEST TSDR UALA2010050301464Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 1 LIGHT IS INOPERATIVE. RELAMPED. CHECKS GOOD.SDR UALA2010050301462Light · inoperativeEMERGENCY LIGHT AT SEAT 48G IS INOPERATIVE. REPLACED EMERGENCY LIGHT. CHECKS GOOD.SDR UALA2010050301461Light · inoperativeEMERGENCY LIGHT AT SEAT 45G IS INOPERATIVE. REPLACED LIGHT ASSY. CHECKS GOOD.SDR UALA2010040801182Engine · failedLEFT ENG FAILURE AT TAKE OFF. OPS CHECKS ON ENG DONE IAW MM. REPLACED NR1 ENGINE.SDR UALA2010031800907Module · failedCAPTAIN'S ND, CTR UPPER AND LWR DU'S BLANK OUT INDISCRIMINATELY. RADAR FAILED MSG DISPLAYS ON ND WHEN SCREENS GOES BLANK. SELECTED ALT CONTROL DISPLAY SW, NO HELP. BLANKING IS MOMENTARY AS IF GRAPHICS GEN ARE SWITCHING. REPLACED L AIMS AND COMPLETED SOFTWASDR UALA2010030800784Light · brokenPAX SEAT 51D EMERGENCY LIGHT ASSY BROKEN. REPLACED PAX SEAT EMERGENCY LIGHT ASSY AND OPS CKD GOOD.SDR UALA2010030200749Circuit Card · faultyICE DETECTORS BOTH LEFT AND RIGHT ICE DETECTORS FAILED. MAINT MSG 30-10141 ON MAT. RESET LEFT AND RIGHT ACIPS, MSG CLEARED MOMENTARILY THEN RETURNED. REPLACED LEFT AND RIGHT ACIPS CARDS.SDR UALA2009091102874Module · faultedBRIEF ELECTRICAL ENCOUNTER RESULTING IN MULTIPLE EICAS MESSAGES AND WARNINGS. ACFT DOWNLINKED FAULT ELEC GEN SYST LEFT MSG 31-69624, AND POWER BUS (L MAIN AC BUS) IN P100 IS NOT POWERED.THE BRIEF POWER EVENT IN THE LT MAIN AC BUSS CAUSED FAULT MESSAGES IN THE SDR UALA2009090902848Battery Pack · dischargedDOOR 4L EMERGENCY EXIT SIGNS, AND SEVERAL EMERGENCY CEILING LIGHTS INOP. CHARGED BATTERY PACK, OPS CHECKS GOOD.SDR UALA2009090802836Battery · defectiveMAIN BATTERY STATUS MESSAGE. REPLACED MAIN BATTERY. OP'S CHECKED GOOD.SDR UALA2009083102706Pump · malfunctionedLATE CALL, RIGHT AFT FUEL PMP STATUS MSG DISPLAYED. LO PRESS LIGHT ON, WITH PUMP SWITCH ON. REPLACED RIGHT AFT MAIN BOOST PUMP. OPS CHECKED OKAY, LEAK CHECKS OKAY.SDR UALA2009082402628Control Valve · failedPACK FCV R STATUS, RESET ONCE NOW BACK ON. REPLACED UPPER FLOW CONTROL VALVE AND OPS CHECKED.SDR UALA2009082402599Gcu · disconnectedELEC GEN SYS RT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. REPLACED RT ENG GCU WITH GCU SWAPPED FROM APU POSITION OPS CHECK OK, MSG CLEARED. (MR24241-74 NOW IN RT ENG SDR UALA2009080302306Idg · faultyEICAS MSG IDG FILTER DISPLAYED, FOUND RED DELTA P POPPED ON IDG. REPLACED RIGHT ENGINE IDG AND RAN ENG. OPS CHECKS OKAY.SDR UALA2009063001880Seal · blownAPU AND APU CONTROL STATUS MESSAGES. FOUND SURGE DUCT SEAL BADLY BLOWN, DUMPING HOT AIR INTO APU COMPARTMENT. REPLACED SURGE DUCT SEAL.SDR UALA2009062901821Light · inoperativeSEAT 29G EEL DAMAGED INOPERATIVE. REPLACED LAMP ASSEMBLY, CHECKS OKAY.SDR UALA2009062901820Light · inoperativeSEAT 20G EEL DAMAGED INOPERATIVE. REPLACED LAMP, CHECK OKAY.SDR UALA2009062901819Light · brokenSEAT 52G EEL DAMAGED INOP. REPLACED BROKEN LIGHT SOCKET AND LAMP. CHECKS GOOD.SDR UALA2009062901818Light · damagedSEAT 35G EEL DAMAGED INOPERATIVE. REPLACED DAMAGED SOCKET AND LIGHT BULB. CHECKS GOOD.SDR UALA2009062901814Light · inoperativeSEAT 30G EEL DAMAGED INOPERATIVE. REPLACED LIGHT ASSY, OP NORMAL.SDR UALA2009062901813Light · inoperativeSEAT 18G EEL DAMAGED INOPERATIVE. REPLACED LIGHT ASSY, OP NORMAL.SDR UALA2009052701521Idg · failedELEC GEN SYS L IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. GCU ALSO SHOWS INTERNAL FAULT. REPLACED AND TESTED L-GCU (PRECAUTIONARY). IDG REPLACED AND ENGINE RUN CHECKSSDR UALA2009052601513Module · failedLT & RT ICE DETECTOR MSG. REPLACED LEFT AIMS IOM- M008. OPS NORMAL. ICE DETECTOR LT & RT MSG CLEARED.SDR UALA2009042001143Relay · malfunctionedLANDING GEAR DID NOT RETRACT (NO EICAS MSG), RTFL. CHECKED ALL PROX SENSORS AND CONNECTORS ON MAIN GEARS AND NOSE GEAR FOUND NO DISCREPANCY. JACKED AIRCRAFT. CYCLED ALL GEARS. ALL OPS CHECK GOOD WITH GEAR HANDLE AND NO RELATED MESSAGES. REPLACED K32214 AISDR UALA2009012300257Oil Filter · failedRIGHT MAIN IDG OIL FILTER SHOWS BLOCKED ON MAINTENANCE PAGE. REPLACED NR 2 ENGINE MAIN IDG OIL FILTER. IDLE RUN OPS AND LEAK CHECK OK MAINT PAGE SHOWS NORMAL.SDR UALA2009011900214Skin Panel · damagedDEICER STRUCK LT OUTBOARD WING TIP DAMAGING T/E. AFT WING TIP PANEL REMOVED AND ROUTED TO SHOP 273 FOR PERMANENT REPAIR. PANEL REINSTALLED, LIGHT AND STATIC DISCHARGERS CHECKED BY SFOOV AMT. WORK ACCOMPLISHED ON WU U5098J.SDR 2008UALA04214Light · inoperativeFIRE BOTTLE ARMED AND BOTTLE DISCHARGED LIGHTS ON P-40 PANEL INOP. *S/D* FOUND CORRODED INDICATOR LIGHT SOCKETS. REPLACED INDICATOR ASSEMBLY'S OP CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03984Filter · pluggedAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF ONE ARINC 629 CHANNEL. *S/D* FOUND PLUGGED OIL FILTER. APU OIL FILTER PER MM 49-27-03, OP CHECK GOOD. AC OK FOR SERVICE.SDR UALA2008111303985Fseu · faultySTATUS MESSAGES PFCS INTERFACE & FLAP-SLAT CONTROL 1 WILL NOT ERASE. REPLACED FSEU 1. REPLACED SFCU 1.SDR 2008UALA03985Warning Message · illuminatedSTATUS MESSAGES PFCS INTERFACE & FLAP-SLAT CONTROL 1 WILL NOT ERASE.SDR 2008UALA03959Shutoff Valve · faultyEICAS STABILIZER R. *S/D* FOUND FAULTY SHUT OFF VALVE AND BAD CONNECTOR. REPLACED SHUT OFF VALVE AND CONNECTOR, OP CHECK GOOD. AC OK FOR SERVICE.
SDR 2008UALA03351Module · faultyDURING LIGHT TEST GREEN ON LIGHT FOR RAT DID NOT COME ON. *S/D* SUSPECT FAULTY RAT CHECK OUT MODULE. REPLACED MODULE RERACKED A4 CARD, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03207Control Unit · faultyHYD PUMP DEM C1 LOW CENTER HYDRAULIC DEMAND PUMP NR 1 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 1 OVERHEATED. STATUS MSG03- NOT ACTIVE INITIAL CLIMB MODE DEPENDENT; AIR DRIVEN PUMP (ADP) (C1) SPEED IS OUT OF RANGE. DB- HYDRAULIC INTERFACE MODULE (SDR UALA2008111302843Switch · faulty"STAB AUTO SHUTDOWN" STATUS MSG IS DISPLAYED ON EICAS. STAB SYS GND TEST FAILS. EXISTING FAULTS MAINT MSG 27-10007, 27-10010..UNABLE TO CONTROL STAB TRIM USING RT STAB TRIM CUTOUT SWITCH, STAB CONTINUES TO MOVE WITH SWITCH IN CUTOUT. REPLACED STCM SHUTOFF VALSDR 2008UALA02843Stabilizer · malfunctioned"STAB AUTO SHUTDOWN" STATUS MSG IS DISPLAYED ON EICAS. STAB SYSTEM GND TEST FAILS. EXISTING FAULTS MAINT MSG 27-10007, 27-10010. UNABLE TO CONTROL STAB TRIM USING RIGHT STAB TRIM CUTOUT SWITCH, STAB CONTINUES TO MOVE WITH SWITCH IN CUTOUT.SDR 2008UALA02613Warning Horn · malfunctionedEQUIPMENT COOLING HORN KEEPS GOING OFF. FOUND EQUIPMENT COOLING AIR FILTER DIRTY. REPLACED FILTER. RESET ECS CARD HORN SILENCED. AC OK FOR SERVICE.SDR 2008UALA02612Detector · failedICE DETECTOR L LEFT ICE DETECTOR FAILURE. STATUS CREW COMMENTS, STATUS MESSAGE ICE DETECTOR L MSG-3010141 ACTIVE ES HARD. REPLACED ICE DETECTOR LRU IAW MM30-81-01 OPS CHK GOOD. AC OK FOR SERVICE.SDR 2007UALA04872Connector · damagedRIGHT UTILITY BUSS NO POWER. FOUND PIN "A1" DAMAGED ON M24211 & ON RECEPTICAL. REPLACED P200 PANEL. ACCOMPLISHED P200 PANEL OP CHECK. A/C OK FOR SERVICE.SDR 2007UALA04592Wire Harness · damagedFLAP SLAT SKEW MSG IN VIEW. FOUND WIRE HARNESS DAMAGED ON RT OUTBOARD FLAP-SLAT SKEW. REPLACED SKEW SENSOR NR 7 WIRING HARNESS. OP CHECKED PASSED. AC OK FOR SERVICESDR 2007UALA02972Light · inoperativeNR 4R DOOR EXTERIOR EMERGENCY SLIDE LIGHT INOP. RELAMPED SLIDE LIGHT.SDR 2007UALA01981Module · failedSPOILERS FAILURE OF ONE OR MORE SPOILER PAIRS. [07-13-07] PULLED CIRCUIT BREAKER. RERACKED ACTUATOR CONTROL ELECTRONICS (ACE) - L2 MODULE. RESET CB AND PERFORMED PRIMARY FLIGHT CONTROL MAINT ACCESS TERMINAL (MAT) TEST, PASSED. MSG NOT ACTIVE AND SPOILER ADVSDR 2006UALA01849Engine · leakingRECEIVED LOW OIL PRESSURE MSG ON RIGHT ENGINE. OIL PRESSURE CONTINUED TO DROP. SHUT DOWN ENGINE. 1 HPT STAGE-2 BLADE FRACTURED AT AIRFOIL MID-SPAN. TRAILING EDGE COOLING HOLES PARTIALLY PLUGGED DUE TO INTERNAL SULFIDATION. THIS SULFIDATION CHOKES-OFF COOLSDR 2006UALA01279Adc · inoperativeACTIVE CRUISE HARD;SECONDARY ATTITUDE AIR DATA REFERENCE UNIT HAS NO OUTPUT ON ANY BUS. FIM: 34-21T TASK 874LONMSG-3438801 ACTIVE ER HARD MSG-3438801 ACTIVE ER HARD. REPLACED SECONDARY ATTITUDE AIR DATA REFERENCE UNIT. HAS NO OUTPUT ON ANY BUS. AIRCRAFT SSDR 2006UALA00336Bleed Valve · malfunctionedON CLIMBOUT RECEIVED -BLEED OFF ENG L- EICAS MESSAGE. AT CRUISE, RESET LEFT ISO VALVE AND LEFT ENG BLEED VALVE. BLEED RESTORED 6 MINUTES THEN -BLEED OFF ENG L- MESSAGE AGAIN WITHOUT ISO VALVE CLOSING. TEMPERATURE SENSOR WAS REPLACED AT ORD. TESTING OF REMOSDR 2004UALA01175Aspirator · damagedASPIRATOR HAS DAMAGED FLAPPER VALVE. FAILED AIR RETENTION TEST DUE TO LEAKING OF VALVE. SUPPLEMENTAL DATA UPDATE SLIDE/RAFT WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. DISCREPANT ASPIRATOR WAS OBSERVED DURING SLIDE/RAFT OVERHAUL AIR RETENTION SDR 2002UALA01452Floorbeam · crackedFLOORBEAM MIDCHORD CRACKED AT LBL 38, STA 246. MAJOR REPAIR ACCOMPLISHED. DOUBLER ANGLE INSTALLED.
Back to N210UA