N210UA
Service difficulty reports · 205
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012030201300Connector · faultyCEILING LIGHT ASSY L33146 ABOVE AFT LT LAV STA 1980, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR. CHECKS GOOD.SDR UALA2012030101280Controller · faultyPER FUELER RT OUTBD REFUEL VALVE WILL NOT OPEN. RENDERED RT OUTBD REFUEL VALVE INOP PER MEL 28040. RPLC'D RT OUTBD REFUELING VALVE CONTROLLER PER MM. OPS AND LEAK CHECK GOOD.SDR UALA2012012700558Fitting · scratchedRIGHT SIDE OF LOWER TORSION LINK FITTING AREA 1.5' SCRATCH. SMOOTH OUT BY HAND BLENDING, CHKD X10 GLASS AND APPLIED FR PRIMER PER ECRA 3221-01129 PART 1 & 2. PER SHOP AMTS 116720, 020221, 100015, 139269 AND INSP 30591. PERMANENT REPAIR PER ECRA AS STATED ABSDR UALA2012012600538Cylinder · damagedNOSE GEAR STRUT CYLINDER AND TOW BAR CONNECT FITTING DAMAGE BY BROKEN TOW BAR HIT. FOLLOWED ECRA3221-01129.SDR UALA2012012400495Window · faultyR1 WINDOW ANTI-FOG ELEC TERMINAL BURNT. NRTMM REPLACED PLUG. REQUIRES WINDOW RPLCMNT. KIT 109-7290, WINDOW 120-4147 & TYSTRAP 586-1594. R1 WINDOW WAS REMOVED. RECEIVED NEW WINDOW AND COA KIT. FOUND J13 TERMINAL WIRE WAS BURNT. REPLACED R1 WINDOW AND J15,SDR UALA2012011600345Wire · faultyRIGHT ACE FAILS ACE MONITORING TEST. TRIED RESETTING, NO HELP. ACE ON ORDER FROM TERMINAL PCN: 483-9204. STARTED REMOVAL PER MM. PULLED APPLICABLE CBS ON PSA-R. ACE MONITOR TEST" FAILS TEST WITH MSG 27-13007, EICAS SHOWS "FLIGHT CONTROL STATUS" MSG.
FOUNSDR UALA2012011200259Sensor · failedBURNING ODOR IN COCKPIT. ODOR IS COMING FROM COCKPIT TEMP SENSOR AREA. DISCONNECTED CONNECTOR M21601 AND M21600 AND STOWED. AUTOTEMP CONTROL INOPERATIVE. REPLACED FLIGHT COMPARTMENT AIR TEMP SENSORS, CHECKED OKAY.SDR UALA2011121406840Relay · faultyDC POWER WILL NOT ENERGIZE WHEN BATTERY SWITCH PUSHED IN. RELAY K24006 & K24025 REPLACED AT P310 POWER MANAGEMENT PANEL, NO HELP. NOTE, GROUND POWER ENERGIZED & BATTERY SWITCH ON, DC POWER ENERGIZED, DE-ENERGIZED GROUND POWER , DC POWER STAY ON. BATTERY SWITCSDR UALA2011110405997Unknown · malfunctionedAPU CONTROL MESSAGE PRESENT. MESSAGE 49-10760. "ELECT. MOTOR HAS BRUSH WEAR" --INF- :NOTE: APU ELECT STARTER & START CONTACTOR REPLACED 16OCT2011 FOR SAME MSG. REF: FIM 49-40 AND PERFORM TASK 807 ESPECIALLY THE PIN, WIRE CHECKS. IF SIGNED OFF AS "OPS OK" IT SDR UALA2011110405998Idg · leakingELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). ADVISORY MSG-2431552 LATCHD ER MODE. REPLACED RT IDG PER AMM. OPS CHECK AND LEAK CHECK OKAY.SDR UALA2011102505773Unknown · odorODOR IN AFT CABIN GALLEY, RETURNED TO FIELD. ODOR DESCRIBED AS A RUBBER SMELL. THAT ODOR MOST PREVALENT IN AREA OF ROW 35. CREW HAD MADE A SLIGHT INCREASE IN CABIN TEMPS JUST PRIOR TO REPORT OF ODOR FROM CABIN. RECIRCULATION FILTERS WERE REPLACED, UPPER ASDR UALA2011101205529Detection Sys · failedBLEED LOOP 1 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR LEFT DUCT LEAK OVERHEAT DETECTION SYSTEM (DLODS) CARD. STATUS MSG-2631141 INACTV ER INTER MSG-2631131 INACTV CL INTER. MSG 26-31141 DISPLAYED ON MAT REF FIMMAN 26-18-803 FOR FAULT ISOLATION.SDR UALA2011101005462Tire · wornNR 2 FRONT LT MLG TIRE HAS METAL PROTECTOR EXPOSED. REPLACED NR 2 MLG TIRE ASSY.SDR UALA2011100705429Circuit Card · mismarkedWHEN CHECKING SYSTEM CONFIG FOR LEFT DLODS CONTROL CARD FOUND HARDWARE PART NUMBER FIELD FILLED WITH MULTIPLE STAR SYMBOLS INSTEAD OF 35010-30. CENTER AND RIGHT CONTROL CARDS SHOW CORRECT NUMBER. REPLACED LEFT DLODS CARD. CORRECT HARDWARE P/N AND SOFTWARE OSDR UALA2011100705428Module · failedCPM-BASIC MODULE (M002) IN RIGHT AIMS FAILED. REPLACED RIGHT AIMS CPM- BASIC (M002) MODULE IAW MM, OPS NORMAL.SDR UALA2011092805248Attach Fitting · out of adjustSECURITY GATE RELEASE KNOB AND ATTACH FITTING OUT OF ADJUSTMENT. SECURED RELEASE KNOB AND BOTTOM FLOOR ATTACH FITTING.SDR UALA2011072503764Potentiometer · faultedMASTER BRIGHT SWITCH WHEN TURNED FULL BRIGHT ALL STDBY INSTRUMENTS. FOUND THAT WHEN MASTER BRIGHT CONT (P5 PANEL) ENGAGED (BUTTON PUSHED IN) THAT STBY INSTRUMENTS CAN GO FULL DIM WITH LIGHT PRESSURE ON KNOB. WITH MASTER BRIGHTNESS DISENGAGED STBY LIGHTING ANSDR UALA2011071903658Crank Assy · defectivePUSH BUTTON ON F/O'S SLIDING WINDOW CRANK STUCK IN DEPRESSED POS. REMOVED AND REPLACED CRANK.SDR UALA2011070503294Processor · inoperativeUNABLE TO GET FULL REQUESTED FUEL INTO ACFT (UNABLE TO FUEL ABOVE 82,900). RERACKED PROCESSOR AND RESET CB'S OPENED. RESET NO HELP. BOTH RIGHT REFUEL VALVES INOPERATIVE. REPLACED INTEGRATED REFUEL PANEL PER AMM. REPLACED FUEL QTY PROCESSOR UNIT. REFUEL SDR UALA2011070503293Connector · looseEEL LIGHTS ROWS 44 THRU 53 RT & LT INOP. FOUND LOOSE CONNECTOR BELOW ROW 44, SECURED SAME, EEL LIGHTS OP CHECK NORMAL.SDR UALA2011070103261Processor · faultyAIRCRAFT WILL NOT TAKE FUEL. PROCESSOR FOUND DEFECTIVE. REPLACED FUEL QUANTITY PROCESSOR PER MM. OPS OKAY.SDR UALA2011053102665None · noneICE DETECTOR L MESSAGE DISPLAYED. ACCOMPLISHED FIM 30-81 TASK 802. TESTED OKAY.SDR UALA2011041101757Connector · unsecureRIGHT ENGINE DID NOT SHUT DOWN WHEN FUEL LEVER PLACED IN CUT OFF PER CREW. ACP MAT TEST ON FMU TEST IS GOOD. ACP CLEANED AND RE-SECURED FMU CONNECTOR J3. ACP RT ENG RUN ENG SEVERAL TIMES ENG SHUTDOWN WITH FUEL CUTOFF. OPS CHECK IS NORMAL.SDR UALA2011041101736Detector · failedICE DETECTOR L LEFT ICE DETECTOR FAILURE. SEE HISTORY. NO TIME TO T- S AND REPLACE. REPLACED DETECTOR, TEST PASSED ON MAT.SDR UALA2011041101739Shutoff Valve · vibrationVIBRATION IN APU DUCT WITH APU BLEED VALVE OPEN (AT DOOR 3L). REPLACED 1 ADP SHUTOFF VALVE PER MM & RE-INSTALLED BOTH SERVO HEATER PROBES. OPS CHECK OKAY, NO VIBRATION NOTED.SDR UALA2011040801702Probe · faultyR ENG T3 THERMOCOUPLE PROBE CH A IS OUT OF RANGE. REPLACED T3 THERMOCOUPLE PROBE PER MM. OPS CHECKED OKAY.SDR UALA2011040501637O-Ring · leakingFUEL LEAKING FROM AFT SPAR, LT WING. REPLACED O-RINGS ON LT OTBD REFUEL VALVE CONTROL UNIT, NO LEAKS NOTED DURING REFUELING OF ACFT.SDR UALA2011033101545Display · inoperativeRT COPILOT PFD BLANK. SWAPPED LEFT DU INTO CENTER POSITION. CENTER DU IS INOP. REPLACED CTR LWR DU AS PER MM. INSTALLATION TEST, PASSED.SDR UALA2011032901501Seal · pinchedFUEL NOTED AT PRESSURE SWITCH OF APU DC FUEL PUMP AT LT FWD SPAR AREA. REPLACED APU PUMP SWITCH PER MM. NO FUEL LEAK FOUND AFTER RE-ACTIVATING PUMP AND FUEL PRESS SWITCH O-RING REPLACED. SWITCH WAS NOT FULLY SECURED UPON REMOVAL, SEAL WAS PINCHED.SDR UALA2011032801468Converter · faultyLEFT BACKUP GENERATOR IS OFF OR HAS FAILED. ELECTRICAL BACKUP GENERATOR LT EICAS MESSAGE. ATTEMPTED RESET. MESSAGE RE-APPEARED. REPLACED BUG CONVERTER PER MM. NO FAULT NOTED.SDR UALA2011031001159Fire Bottle · dischargedNR 1 ENG FIRE EXTINGUSHING BOTTLE EICAS MESSAGE AND BOTTLE ENG NR 1 INDICATING LIGHT ILLUMINATED. FOUND NR 1 FIRE BOTTLE DISCHARGED. REPLACED NR 1 FIRE BOTTLE PER MM. OPS CHECKED AND TESTED FIRE BOTTLE SYSTEM PER MM.SDR UALA2011030801133Sign · looseAISLE EXIT LIGHT SUPPORT IS WEARING AND LOOSE ON THE INBD CEILING CONNECTION. REPLACED CROSSAISLE EXIT SIGN PER MM.SDR UALA2011030301039Pressure Switch · leakingFUEL LEAK LEFT INBD AREA NEAR FUEL PUMP BAY AREA. APU DC FUEL PUMP ONLY LEAKING AT PRESS SWITCH WHEN PUMP IS RUNNING. WHEN PUMP IS OFF AND DURING FUELING VERIFIED NO LEAKS OUT OF PUMP.SDR UALA2011021400774Video Unit · faultyALL VIDEO MONITORS ARE OFF LINE AND WILL NOT RESET. VIDEO INTERFACE UNIT ON ORDER. REPLACED VIDEO INTERFACE UNIT AND RECYCLED VIDEO MONITORS CB, NO HELP. NEED MORE TROUBLESHOOTING. REPLACED VIU, OPS CHECK OK.SDR UALA2011021400772Rub Strip · damagedNR 1 ENGINE ATTRITION LINER AT 6 O'CLOCK POSITION FILLER REPAIR, BREAKING LOOSE. APPROX 3"X 2". ON WALK AROUND FOUND NR 1 ENG RUB STRIP AT APPROX 6 O'CLOCK POSITION DAMAGED. DAMAGE IS WITHIN THE RUB STRIP INNER LAYER, MEASURING 3.5 INCHES WIDEST AREA. FAN RUSDR UALA2011020100555Power Supply · damagedLEFT FLIGHT CONTROL PSA HANDLE IS BROKEN. UNIT M24101 IS LOCATED ON E1-6 SHELF. REPLACED PSA LEFT.SDR UALA2011020100554Pcu · no testACE MONITOR TEST FAILED MSG27-13004. FOUND ACTIVE MESSAGE 27-10116. LT INBD ELEVATOR PCU PRESSURE REDUCER SOLENOID OPERATED VALVE IS NOT IN COMMANDED POSITION. TRIED NEW ACE- NO HELP. VERIFIED 28 VDC AT PCU CONNECTOR IAW FIM. IAW FIM WIRE CHECKS OK FROM ASDR UALA2011011900308Charger · faultySTATUS MESSAGE BAT CHARGER APU. REPLACED AND TESTED APU CHARGER PER MM, CHECKS OKAY.SDR UALA2011011300216Satcom · faultySATCOM EICAS MSG 2 SATCOM STATUS MSGS. REPLACED SATCOM DATA UNIT PER AMM, BITE TEST OKAY, LOG-ON LOW AND HIGH GAIN GOOD.SDR UALA2011010600091Precooler · leakingNR 1 ENG, PNEU LEAKAGE NOISE FROM UNDER COWLING. FOUND AIR LEAK FROM PRECOOLER. NR 1 ENG AIR LEAK FROM PRECOOLER, ALSO FAILS LEAKAGE TEST. RECEIVED PARTS AND TOOLING 0030. PRECOOLER REMOVED AT 0200. REPLACED L ENG PRECOOLER.SDR UALA2011010600090Monitor · false activationVIBRATION INDICATION (ENGINE) - BLANK MSG01- ACTIVE ENGINE START HARD; SIGNAL CONDITIONER UNIT (LEFT) HAS NO OUTPUT ON SYSTEM ARINC 629 BUS (LEFT). DB- LEFT AIMS MSG-7708841 ACTIVE ES HARD. RESET CIRCUIT BREAKER PER FIM 77-31-825, NO HELP. RESET AIRCRAFT PSDR UALA2010121704609Packing · leakingFUEL LEAKING LT ENGINE NR9 STRUT DRAIN. PRESSURIZED FUEL SYS FOUND LOWER COUPLING LEAKING VIEW THRU PNL 432CR. FUEL LEAKING FROM COUPLING CONNECTION INSIDE PYLON. LOOKING UP THROUGH ACCESS PANEL 432CR. NEW PACKINGS IN FUEL OFFICE. R & R PACKINGS AT LOWER COUPSDR UALA2010091703470Idg · faultedLT ENGINE IDG FILTER INDICATES "BLOCKED" ON MX ELECTRICAL PAGE. LT IDG DISCONNECTED. PRESSURE INDICATOR PIN WAS EXTENDED IAW MEL. IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED. REPLACED IDG PER MM. OPS NORMAL.SDR UALA2010081102931Battery · malfunctionedMAIN BATTERY CHARGER MAIN STATUS. REPLACED MAIN BATTERY, TESTED OK. MESSAGE GONE.SDR UALA2010062802292Light · crackedFLOOR EMERGENCY LIGHT CRACKED AT GALLEY F2. REPLACED LIGHT ASSYS, OP CK OK.SDR UALA2010062802291Light · crackedFLOOR EMERGENCY LIGHT CRACKED AT M1 GALLEY. REPLACED LIGHT ASSYS, OPS CK OK.SDR UALA2010062402243Sign · brokenEMERGENCY EXIT SIGN BROKEN FWD OF DOORWAY 3R. REPLACED EMERGENCY EXIT SIGN, OP CHECK OKAY.SDR UALA2010062402242Indicator · looseDOOR 3R EPAS RESERVOIR PRESSURE INDICATOR IS LOOSE. REPLACED EPAS RESERVOIR. OPS NORMAL.SDR UALA2010062402241Battery Pack · inoperativeEMERGENCY LIGHTS AT DOOR 4L WILL NOT REMAIN ILLUMINATED. BATTERY PACK DOES NOT TEST. REPLACED EMERGENCY BATTERY PACK M3340, OPS CHECK OK.SDR UALA2010062402240Battery Pack · inoperativeEMERGENCY LIGHTS AT DOOR 3L WILL NOT REMAIN ILLUMINATED. REPLACED EMERGENCY LIGHT BATTERY PACK M33406, OPS CK OK.
Back to N210UA