N21129
Service difficulty reports · 96
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N21129' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N21129' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20260406002Sign · inoperativeFWD CEILING EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED EMERGENCY EXIT SIGN. OPS CHECK SAT.SDR JJBA20260327015Lamp · inoperativeRH WING/FUSELAGE FWD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RH FWD EXT EMERGENCY LAMP. OPS CHECK SAT.SDR JJBA20260220055Sign · detachedEXIT SIGN BY 1A FALLING OFF. SECURED EXIT SIGN.SDR JJBA20260119039Lamp · inoperativeRIGHT OVERWING EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RH OVERWING EXTERNAL EMERGENCY LAMP. OPS CHECK SAT.SDR JJBA20250627019Battery Pack · no testMULTIPLE EXTERIOR AND INTERIOR EMERGENCY LIGHT INOPERATIVE. SUSPECT BAD BATTERY. REMOVED AND REPLACED EMERGENCY BATTERY 3. OPS CHECK SAT.SDR JJBA20250613012Lamp · inoperativeINTERIOR EMERGENCY LIGHS ABOVE SEATS 18A AND 18CD INOPERATIVE. REMOVED AND REPLACED BOTH BULBS. OPS CHECK SAT.SDR JJBA20250529092Trim Panel · unsecureSERVICE DOOR HARD TO OPEN OR CLOSE. FOUND DOOR TO BE BINDING ON TRIM. RESECURED TRIM. OPS CHECK GOOD.SDR JJBA20250509046Lock · out of adjustMCD NOT SEALED FULLY WHILE SHOWING CLOSED. REMOVED THE SIDE HINGE MAIN DOOR LINING. SERVICED AND ADJUSTED ACTUATING AND LOCKING MECHANISM OF MCD. UPS/LEAK CHECK SAT. PERFORMED PRESSURIZATION CHECK. LEAK CHECK SAT. INSTALLED MCD LINING.SDR JJBA20250502074Manifold · leakingHYD SYSTEM 1 FAIL WITH MFD HYD SYSTEM INDICATION ZERO. REMOVED AND REPLACED LH HYD MANIFOLD ASSEMBLY. OPS/LEAK CHECK SAT.SDR JJBA20250217027Skin · mechanic error2 MISDRILLED HOLES ON RUDDER II ABOVE ACCESS PANEL 327CL. REMOVED DAMAGE ON RUDDER 2 ABOVE ACCESS PANEL, FABRICATED REPAIR PARTS, LOCATED AND DRILLED HOLES. PREP, PRIMED DOUBLER AND FILLER. INSTALLED DOUBLER AND FILLER REPAIR PARTS ON RUDDER 2 ABOVE ACCESS PNLSDR JJBA20250225008Skin · damagedDAMAGE TO THE LH REAR FUSELAGE 1 AT FRAMES 70 TO 72 AND STRINGERS 16L-18L. PERFORMED HIGH FREQUENCY EDDY CURRENT INSPECTION ON AND AROUND DAMAGED AREA OF LH REAR FUSELAGE I FROM FRAMES 70-72, STRINGERS 16L-18L. NO INDICATION OF CRACKS FOUND AT THIS TIME. REMOVSDR JJBA20250317001Doubler · damagedFOUND DOUBLER ON RUDDER 1 FRON LH SIDE TO BE DAMAGED. REMOVED RUDDER 2. REMOVED RUDDER 1. REMOVED DOUBLER ON RUDDER 1. FABRICATED NEW DOUBLER W/ 2024-T3 0.040". TRANSFERRED HOLES TO NEW DOUBLER. INSTALLED DOUBLER ON RUDDER 1. APPLIED FILLET SEAL TO DOUBLER. INSDR JJBA20250317005Panel · damagedDURING INSPECTION FOUND SURFACE CORROSION INSIDE PANEL 335GB ON LH ELEVATOR. REMOVED LH ELEVATOR. REPLACED LH ELEVATOR TIP. INSTALLED LH ELEVATOR. INSTALLED NEW HARDWARE TO ATTACH TORQUE TUBE TO STABILIZER STRUCTURE. BALANCED L ELEVATOR. INSTALLED ELEVATOR ANDSDR JJBA20231128030Lamp · inoperativeFOUND RH FORWARD LOWER FAIRING EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RH FORWARD LOWER FAIRING EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20231128018Battery Pack · inoperativeFOUND FWD CENTER INTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY #4. OPS CHECK SAT. REMOVED AND REPLACED FWD CENTER INTERIOR EMERGENCY EXIT LIGHT. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA20231011012Unknown · unknownOVERWING PASSENGER EXIT SIGN FALLING DOWN (CENTER). RESECURED EXIT SIGN. OPS CHECK SAT.SDR JJBA20230606005Unknown · unknownENTRANCE BEAM HAS CORROSION. REMOVED FLOOR SUPPORT BEAM AND REPLACED WITH NEW.SDR JJBA20230606004Unknown · unknown2 FLOOR DOUBLERS IN FRONT OF SERVICE DOOR CORRODED. INSTALLED DOUBLERS.SDR JJBA20221130033Snap Ring · wornMAIN CABIN DOOR NOT OPENING FROM INSIDE. FOUND SNAP RING ON INTERMEDIATE TORQUE TUBE WORN AND OUT OF PLACE. REMOVED AND REPLACED SNAP RING. OPS CHECK SATSDR JJBA20220919021None · noneLG AIR/GROUND FAIL, DID NOT RETRACT ON TAKEOFF AFTER 400FT. PLACED AIRCRAFT ON JACKS TO TROUBLESHOOT FAULT, WHILE AIRCRAFT IS OFF GROUND, AIRCRAFT GOES INTO ESSENTIAL MODE WITH "ELEC ESS ERF FAIL" MESSAGE ON EICAS. PERFORMED FIM, FAILURE ON ESSENTIAL BUS CONTASDR JJBA20211214017Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED #3 EMERGENCY BATTERY. OPS CHECK GOOD.SDR JJBA20211107013None · noneRH AFT EMERGENCY LIGHT INOPERATIVE. R&R AFT EMERGENCY LIGHT BULB. OPS CHECK SAT.SDR JJBA20210826057Light · inoperativeEMERGENCY LIGHT ABOVE PAX DOOR INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT ABOVE PAX DOOR. OPS CHECK SATSDR JJBA20210708017Gusset · corrodedFF2 LH INBD FLOOR GUSSET FOUND CORRODED FR 8-13. DOUBLER CUT. FF2 LH INBD FLOOR GUSSET BTW FR 8-13 REPLACED WITH REPAIR DOUBLER.SDR JJBA20210708015Flange · crackedRH PYLON YOKE UPPER FLANGE HOLE (X1) FOUND WITH CRACK. RH PYLON YOKE UPPER FLANGE HOLE REAMED. AFTER NDT INSPECTION, DAMAGE IS STILL PRESENT AT RH PYLON YOKE UPPER FLANGE. HOLE OVERSIZED AT SECOND PERMISSIBLE DIMENSION (0.421). 2 BUSHINGS LOCALLY FABRICATED. RSDR JJBA2021071508014Skin · corrodedCF1 ON RH FUSE AT FR23 AT LEVEL JUNCTION STRINGER SPLICE STR 16R-17R-18R CORRODED. CORROSION ON STR 16R AND 17R AT FR 23 RH FUSE BLENDED AND FOUND WITHIN LIMIT. NO SIGNIFICANT LOSS OF MATERIAL. CORROSION ON STR 18R AT FR 23 BLENDED, FOUND OUT OF LIMITS. STR 18SDR JJBA20210708011Beam · corrodedCF1 ON LH FUSE OMEGA BEAM LH AND REPAIR ANGLE CORRODED. OMEGA BEAM REPLACED AND INSTALLEDSDR JJBA20210629008Doubler · corrodedCF 1 ON RH FUSE BTW FR 19-20 SILL ASSEMBLY FWD AND DOUBLER SILL AFT CORRODED. CF1 ON RH FUSE BTW FR 19-20 SILL ASSY FWD CORROSION REMOVED WITHIN LIMITS AND REPROTECTED. LESS THAN .001" REMOVED. DVI INSP C/OUT WITH MAGN GLASS 30X NO FAULT FOUND. CF1 RH SILL AFTSDR JJBA20210629007Flange · corrodedFRAME 65 LOWER FLANGE AT STR 16L CORRODED. FRAME 65 LOWER FLANGE AT STR 16L BLENDED OUT OF LIMIT. CUT OUT ON FR65 LOWER FLANGE AT STR 16L REPAIRED.SDR JJBA20210629006Door Frame · corrodedCORROSION FOUND ON CARGO DOOR FRAME 65 BTW STR 16 & 17. CARGO DOOR FR65 BTW STR 16L AND 17L CORROSION REMOVED OUT OF LIMITS. FR65 CUT AND SPLICE MFG BTW STR 14L-15L. CARGO DOOR FRAME 65 LH BTW STR 14-15 REPAIRED.SDR JJBA20210313013Tube · crackedON CLIMB OUT AT 6000 FEET E2 BLEED LEAK MESSAGE ON EICAS. FOUND LEAKING JOINT BLOWING HOT AIR ON SENSOR LOCATION #26. FOUND "T" TUBE BEFORE CROSSBLEED VALVE CRACKED. REMOVED RH BLEED VALVE, RH PACK VALVE, RH A/I VALVE, RH ATS VALVE AND ATTACHING DUCT TO FACILISDR JJBA20210301007Skin · damagedLH WING L/E NO 3 REPAIR FOUND BTW RIB 22-23 ON NOSE SKIN. LH WING L/E #3 REPAIR REWORKED.SDR JJBA20210215028Skin · dentedRIGHT WING L/E NR 1 DENT ON SKIN 4.0 FEET FROM INBOARD EDGE AND 7.5" FROM TOP EDGE. RT WING L/E NR 1 SKIN REPAIRED.SDR JJBA20210209023Rudder · chafedRUDDER 1, LT SKIN CHAFFED 8 INCH FROM LOWER EDGE, 12 INCH LONG. CHAFFED LT SKIN OF RUDDER 1 AT LOWER EDGE REPAIRED.SDR JJBA20210209022Skin · damagedREAR FUSELAGE II, LT SIDE, AT FR 77-78-79, BTW STR 3-8 MULTIPLES REPAIR BUSHING. REAR FUSE II AT FR 77 BTW STR 3-4L SKIN REPAIRED AT THE 2 CONSECUTIVE REPAIR BUSHING LOCATIONS.SDR JJBA20210209017Skin · dentedON RH FUSE SKIN BTW FR 12-11 AND STR 20-21 2 DENTS FOUND. DENT #1 ON RH FUSE SKIN FROM 0650 FWD FR 11 AND 2100 ABOVE STR 21R DENT DRILLED 0185 AND INSTALLED RIVET PLUG. RH FUSE SKIN BTW FR 12-11 AND STR 20-21R DENT #2 IS AN EXISTING BLEND REMAINING 025 AND 032SDR JJBA20210209015Skin · dentedRH FUSE BTW FR 2-3 AND BTW STR 11-13, SKIN DENTED. RH FUSE SKIN BTW FR 2-3 STR 11-13 REPAIREDSDR JJBA20210209013Skin · dentedON RH FUSE DENT FOUND BTW FR26 AND FR25 AND BTW STR 13R AND 14R. DENT IS OUT OF LIMITS. DENT DIMENTION L 0.800 W 0.600 H 0.020. RH FUSE SKIN BTW FR26 & FR25 BTW STR 13R & 14R REPAIRED.SDR JJBA20210204012Skin · damagedSUSPICIOUS BLEND ON RH FUSELAGE SKIN AT FR 68 BTW STR 18-19. DOUBLER REPAIR ON RH LOWER REAR FUS-1, AT FRAME 68, BTW STR 18R-19R REPAIREDSDR JJBA20210203010Skin · not reportedREPAIR DOUBLER ON RH CENTER FUSE 2, BTW FR 26-27 AND BTW STR 16R-18R. REPAIR DOUBLER ON RH FUSELAGE 2, BTW FR 26-27, AND STR 16R-18R REWORKEDSDR RAIA202003100001Valve · inoperativeBLEED 2 OVERHEAT. REMOVED CARGO FLOOR TO INSPECT REFERENCE LINES. REMOVED AND REPLACED #2 FAN AIR VALVE. FOUND NO DEFECTS. OPS CHECK GOOD. AIRCRAFT GOOD FOR SERVICE. MORE INFORMATION AVAILIBLE LATER.SDR RAIA2020022760001Unknown · odorSMOKE IN COCKPIT WITH ASSOCIATED BURNING SMELL. PERFORMED INSPECTION AND OPS CHECK OF CAPT'S AND F/O'S CHART HOLDER LAMPS. NO SMOKE OR BURN SIGNS. INSPECTED RELAY BOX AND RELAY WITH POWER ON AIRCRAFT. NO SIGN OR SMOKE NOTED. INSPECTED L/H AND R/H SIDE WINDSHSDR RAIA201909150001Warning System · false activationABORTED TAKE OFF AT 60KTS. PITCH TRIM T/O CONFIG WARNING. PITCH TRIM INDICATOR NEEDLE MOVING, BUT SETTING STAYS AT 8. RERACKED AURAL WARNING UNIT, CLEANED HSCU CONNECTORS, HORIZ (STAB) ACTUATOR POTS. PERFORMED T/O CONFIG TEST, CHECKS GOOD. VERIFIED HORIZ STAB SDR RAIA2019080760001Flap System · malfunctionedFLAP FAIL ON EXTENSION DURING APPROACH UPON FLAPS 9 EXTENSION, PERFORMED GVI OF FLAPS, RESET FLAP SYSTEM. OPS CHECK GOOD. AC OK FOR SERVICESDR RAIA201905030003Structure · corrodedSTOP SIGN ON RT SIDE AT FRAME 20 HAS CORROSION. REMOVED AND REPLACED STOP SIGN ON RT SIDE AT FRAME 20.SDR RAIA201905030002Structure · corrodedSTOP SIGN ON RT SIDE AT FRAME 22 HAS CORROSION. REMOVE AND REPLACED STOP SIGN AT FRAME 22.SDR RAIA201905030001Angle · corrodedCARGO DOOR Z ANGLE HAS CORROSION. REMOVED AND REPLACED CARGO DOOR Z ANGLE.SDR RAIA20190220001Line · looseENGINE 2 SHUTDOWN IN FLIGHT STARTING DESCENT DUE TO E2 LOW OIL PRESSURE EICAS MSG. R&R NR 2 ENG AFT TUBE OIL LINE TO OUTER BYPASS, OPS AND LEAK CHECK GOOD.SDR RAIA2018110129001Coffeemaker · shortedSMOKE IN GALLEY COMIMG FROM COFFEE MAKER AREA. F/A DISCHARGED FIRE EXTINGUISHER. A/C LANDED IN ROC AND WAS FARRIED TO ORD FOR MX. R&R COFFEE MAKER AND PORTABLE FIRE EXTINGUISHER. ALSO R&R COFFEE MAKER RAIL AND FUSE. ALL OPS CHECKS GOOD.SDR RAIA201804030001Warning System · false activationSTEERING INOP MESSAGE ON EICAS. PERFORMED MIP1.91, MIP SUCCESSFUL. NO FURTHER ACTION REQ.
Back to N21129