N211UA
Service difficulty reports · 189
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N211UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N211UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010040901190Circuit Card · defectiveLT HYD MODULE FAILED. CARD FOUND FAULTY. REPLACED HYDIM CL INTER-FACE CARD. TESTED OKAY PER MM.SDR UALA2010040801181Ram Air Turb · faultyRAT WON'T DEPLOY.SDR UALA2010020100409Actuator · faultyOXYGEN MASK COMPARTMENT OPEN AT SEATS 19H AND 19J ON LANDING. DUE TO CHRONIC PANEL DEPLOYMENT WILL NEED TO REPLACE ELECTRIC LATCH ACTUATOR IAW CH8451 AND VERIFY OPERATION BY MASK DROP. SEATS 19H & 19J NOT TO OCCUPIED UNTIL PSU OXY PNL LATCHING MECHANISM CORSDR UALA2010012100263Valve · malfunctionedRIGHT PACK MODE IN EICAS RT PACK KEEPS TRIPPING OFF. REPLACED THE LOW LIMIT VALVE, OPS CK'D GOOD.SDR UALA2010011900240Oxygen Mask · unsecure19HJ OXYGEN MASK FELL OUT. MASKS UNSECURE. RESTOWED O2 MASKS.SDR UALA2009122103943Line · brokenMANIFOLD AY-SENSING PT4.95 LINE BROKEN AT 6 O'CLOCK POSITION. REPLACED SENSE LINE. ACP'D ENGINE RUN AND TEST AS REQUIRED. ALL INDICATIONS NORMAL.SDR UALA2009111003514Control Unit · malfunctionedWINDOW HEAT L FWD LOSS OF LEFT FORWARD WINDOW HEAT. ADVISORY MSG01- ACTIVE CLIMB HARD; WINDOW SENSOR (LEFT NR 1 ANTI-ICE) CIRCUIT IS OPEN OR SHORTED. DB- WINDOW HEAT CTRL UNIT (LT FWD & RT SIDE) MSG-3021031 ACTIVE CL HARD. REPLACED WHCU, NO HELP. SWAPPED TSDR UALA2009102603325Battery · dischargedTHE 2R FLASHLIGHT NOT BLINKING. REPLACED FLASHLIGHT BATTERY.SDR UALA2009071602106Control Panel · inoperativeCABIN SYSTEM CONTROL PANEL LOCK UP. CABIN SYSTEM CONTROL PANEL INOP, HAVE A CSCP IN DEN. TRIED SWAPPING AREA CONTROL PANEL TOUCH SCREEN WITH CSCP TOUCH SCREEN, NO HELP. NEEDS CSMU ON AOG F5256. MAINT NOTED, ALL OPS CHECK NORMAL.SDR UALA2009062201759Fire Loop · shortedFIRE LOOP 1 APU AUXILIARY POWER UNIT (APU) FIRE DETECTION SYSTEM LOOP 1 FAILURE. STATUS MSG01- NOT ACTIVE CRUISE INTERMITTENT; APU FIRE DETECTION CARD HAS AN INTERNAL FAULT. DB- APU FIRE DETECTION CARD MSG02- ACTIVE CRUISE HARD; APU FIRE DETECTION CARD HAS ASDR UALA2009051301365Indication Sys · malfunctionedFUEL SYNOPTIC PAGE DOES NOT SHOW PRESSURE BAR WHEN RIGHT PUMPS ARE ON. FUEL MGNT INFO PAGE INDICATES BOTH RT PUMPS ARE COMMANDED ON WITH PRESSURE, NO EICAS MESSAGES. AFTER ENGINE START ALL FUEL SYNOPTICS APPEARED NORMAL. FUEL PAGE CKS NORMAL.SDR UALA2009042901240Skin · puncturedLWR FUSELAGE SKIN PUNCTURED FWD AND RIGHT OF DOOR 313AL SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGE EDDY CURRENT CUTOUT. INSTALLED "J" REPAIR.SDR UALA2009042901235Compressor · cracked3 BOLTS SHEARED OFF THE FWD SIDE OF THE COMPRESSOR HOUSING SECTION, 3,9,11 O`CLOCK POSITIONS ON THE APU. REPLACED APU. APU IS READY FOR LEAK AND OPS CHECK. OPS CHECKED GOOD.SDR UALA2009031000723Actuator · leakingNR 1 ENG RT REVERSER ACTUATOR IS LEAKING FROM LOWER ACTUATOR AT APPROX 60 DROPS PER MINUTE WITH SYSTEM DEPRESSURIZED. REPLACED NR 1 ENG LOWER RT THRUST REVERSER LOCK ACTUATOR.SDR UALA2009030501402Actuator · leakingNR 1 ENG RT REVERSER ACTUATOR IS LEAKING FROM LOWER ACTUATOR AT APPROX 60 DROPS PER MINUTE WITH SYSTEM DEPRESSURIZED. REPLACED NR 1 ENG LOWER RT THRUST REVERSER LOCK ACTUATOR.SDR UALA2009031000649Plug · wornAPU IGNITER SYSTEM A IGNITER PLUG WORN. REPLACED IGNITER PLUG.SDR UALA2009022500649Plug · wornAPU IGNITOR SYSTEM A IGNITOR PLUG WORN. REPLACED IGNITOR PLUG.SDR UALA2009012300255Wire · brokenPRIOR TO DEPARTURE, CREW CALL, RIGHT FCV MSG DISPLAYED ON EICAS. ACCOMPLISHED MAT TEST 2X FAILED 2X. LOCKED OUT RIGHT LOWER FLOW CONTROL VALVE PER MEL. RIGHT LWR FLOW CONTROL VALVE LOCKED CLOSED. REPLACED LOWER FCV-RIGHT PACK. FOUND AND REPAIRED BROKEN GRSDR UALA2008111806547Igniter · inoperativeL ENG IGNITOR 1 INOPERATIVE.SDR 2008UALA06358Fan · odorODOR OF SMOKE IN COCKPIT. FOUND FAN BEARING BAD ALSO BLACK SMOKE AT FAN BLADES. REPLACED EQ COOLING FAN.
SDR 2008UALA02247Lamp · inoperativeEXTERIOR EMERGENCY LIGHTS AT DOORS 1L, 2R, AND 4R INOP.SDR 2008UALA01650Oxygen System · reads lowOXYGEN SYSTEM NEEDS SERVICING.SDR 2008UALA01649Warning Light · illuminatedAPU FIRE BOTTLE DISCHARGE ILLUMINATED AT WHEELWELL LOCATION.SDR 2008UALA01006Fuel Control · failedAPU NO START AT DISPATCH. FOUND FUEL& LUBE CLUSTER SHAFTS NOT TURNING. REPLACED FUEL CLUSTER. REPLACED LUBE CLUSTER. PENALTY RUN ACCOMPLISHED, FLITERS & OIL REPLACED, NO DISCREPANCIES FOUND AFTER RUNS. ACFT OK FOR SERVICE.SDR 2008UALA00618Solenoid · faultySTATUS MESSAGE FLAP-SLAT CONTROL 2 DISPLAYED. SUSPECT VALVE SHUTOFF SOLENOID. CHECKED RESISTANCE AT PRIMARY CONTROL SHUTOFF VALVE SOLENOID (V27004). FOUND SOLENOID NEEDS REPLACEMENT. REPLACED SOLENOID. ACFT OK FOR SERVICE.
SDR 2007UALA05119Valve · shutdownAPU AUTO SHUTDOWN AT DEPARTURE. HIGH OIL TEMP. ALSO, APU OIL PRESSURE -3 PSI. REPLACED LUBE CLUSTER AND THERMAL BYPASS VALVE
A/C OK FOR SERVICE.SDR 2007UALA03928Cabin Pressure · fluctuatesFLIGHT EXPERIENCED PRESSURIZATION FLUCTUATIONS. PERFORMED GROUND TEST OF ( L) AND (R) AUTO PRESS CONTROLLERS AND CHECKED NORMAL. NO HISTORY ON THIS AUTO PRESS CONTROL SYS. AS PRECAUTION ALSO CHECKED MANUAL OPERATION OF FWD AND AFT OUTFLOW VLVS. CONDUCTED SDR 2007UALA03619Oxygen Mask · leakingOXYGEN MASK PROBLEM CREW COMMENTS: CAP OXYGEN MASK LEAKS. 10-11-07 REPLACED CAPTAIN'S OXYGEN MASK. LEAK CHECKS GOOD. OK FOR SERVICE. SUSPECT PRESSURIZATION CYCLES & CARELESS STOWAGE CAUSED THE LEAKAGE.SDR 2007UALA02860Apu · odorSTRONG ELECTRICAL ODOR IN COCKPIT. [80-21-07] ACCOMPLISHED FIM 21-00 TASK 808 AND FOUND THE APU TO BE THE SOURCE OF THE ODOR IN THE FLT DECK AND CABIN. ACCOMPLISHED PACK BURN USING ENG BLEED TO OPERATE PACKS, OPS NORMAL NO DEFECTS NOTED. REPLACED BOTH OZSDR 2007UALA02048Blades · damagedRTFL DUE TO NR 2 ENGINE COMPRESSOR STALL. [08-21-07] SURGED IN CLB. EGT EXCEEDED RL FOR 2:37; PEAK 733¡C. SHUTDOWN. METAL IN TAILPIPE. ENGINE REPLACED AT ORD. SHOP DISASSEMBLY REVEALED EXTREME DAMAGE INSIDE THE HP COMPRESSOR. ALL BLADES SHOWED SEVERESDR 2007UALA01790Idg · faultedELEC GEN DRIVE L LEFT IDG FAULT. [07-06-07] REPLACED IDG PER MM 24-11- 01, SUBSEQUENT VERIFICATION FLIGHT CONFIRMED CORRECTION OF PREVIOUS PROBLEM. AIRPLANE OK FOR ETOPS.SDR 2007UALA01437A/C Pack · unknownLEFT AIR COND PACK PROB CAUSED DIVERSION. [SUP 06-01-07] REPLACED RT HAND FLOW CONTROL VALVE PER MM21-51-02. FAULT CLEARED AND OP CHECKED GOOD.SDR 2004UALA00248Smoke · detectedSMOKE ORIGINATE MOMENTARILY AT BEGIN OF DESCENT ON CAPT'S SIDE IN COCKPIT. APU, SHOULDER-FOOT HEATERS OFF. THE REPORT OF SMOKE WAS ON A FLIGHT FROM LAX TO HNL. HNL MX CONDUCTED A COMPREHENSIVE CHECK OF NR 1 ENGINE FOR OIL LEAKS, BUT FOUND NONE. MAINTENANCESDR 2004UALA00099Slide · deployedTHE 2R EMERGENCY EVACUATION SLIDE PARTIALLY DEPLOYED. DOOR 2R SLIDE/RAFT PARTIAL DEPLOYMENT OCCURRED DURING SLIDE INSTALLATION. DURING INSTALLATION SEQUENCE THE DOOR WAS ARMED, THEN WAS INADVERTENTLY OPENED SUFFICIENT TO RELEASE THE SLIDE PACK. AMM PROVIDES ASDR 2003UALA00475Bearing · misrepairedOIL ODOR IN FLIGHT DECK AREA. SMOKE AND ODOR IN MAIN CABIN WITH LOWER RECIRCULATING FAN OFF. *SUPPLEMENTAL DATA UPDATE* MAINTENANCE CONFIRMED THE SMELL WAS COMING FROM APU. APU WAS REPLACED AND THE SHOP DISASSEMBLED THE LOAD COMPRESSOR MODULE TO FIND THE RSDR 2003UALA00177Stiffener · crackedSTA 246 FLOOR BEAM HAD CRACKED STIFFENER AT LBL 26.26 MAJOR REPAIR ACCOMPLISHED. REPLACED STIFFENER.SDR 2003UALA00174Support · cracked(U) CHANNEL SUPPORT IS CRACKED AT STA 246 AFT SIDE OF FLOORBEAM, UPPER OUTBOARD & INBOARD RADIUS. MAJOR REPAIR ACCOMPLISHED. REPLACED 'U' CHANNEL SUPPORT.SDR 2003UALA00173Stiffener · crackedFOUND 3 STIFFENERS CRACKED AT STA 246 FLOORBEAM: LBL 38.5, RBL 7.88, RBL 26.06. MAJOR REPAIR ACCOMPLISHED. STIFFENERS REPLACED.SDR 2003UALA00172Floorbeam · crackedSTATION 246 FLOORBEAM WAS CRACKED AT RBL 38.5 AND LBL 38.5. MAJOR REPAIR ACCOMPLISHED. BOTH CRACKS WERE REPAIRED AT 'C' CHECK.