N218UA
Service difficulty reports · 170
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N218UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N218UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011091905020Relay · faultyCABIN SMOKE INDICATION, RTFL. PER CREW LOWER CREW REST AREA SMOKE DET MSG ON CABIN AREA PANELS WITH ASSOCIATED WARNING HORN SOUNDING. CREW REST DOOR CYCLED, ALT PA SYSTEM SELECTED, BOTTLE DISCHARGE SWITCH SELECTED TO ARM WITH NO HELP. CB'S FOR CREW REST SOV-SDR UALA2011081504331Transceiver · faultyHF RADIO - TRANSMISSION PROBLEM. CREW COMMENTS: HF 1 APPEARS NOT TO XMIT AND TOOK A LONG TIME TO TUNE. LEFT HF CONSIDERED INOPERATIVE. TESTED LEFT HF AFTER AIRCRAFT ARRIVED. HF TRANSMITTED AND RECEIVED NORMAL. REPLACED LEFT HF TRANSCEIVER PER MM. HF CHSDR UALA2011071203485Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK IN DOOR 3R LWR LOBE CREW REST. REPLACED PBE.SDR UALA2011071203484Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 4R. REPLACED PBE.SDR UALA2011071203483Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 4L. REPLACED PBE.SDR UALA2011071203482Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 3R. REPLACED PBE.SDR UALA2011071203481Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 3L. REPLACED PBE.SDR UALA2011071203479Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 1R. REPLACED PBE AT DOOR 1R.SDR UALA2011071203478Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK BY DOOR 1L. REPLACED PBE AT DOOR 1L.SDR UALA2011071203477Pbe · unserviceablePBE POUCH FEELS SPONGY AND SOFT PER 'A' CHECK PAPERWORK IN FLIGHT DECK STOWAGE COMPT. REPLACED PBE IN FLIGHT DECK.SDR UALA2011070103260Strip · peelingUPPER LT SIDE OF RUDDER HAS ELECTRO STATIC METAL STRIP PEELING BACK. REMOVED CORNER SECTION 2X2X3 INCH AREA AND APPLIED SPEED TAPE FOR INTERIM REPAIR PER MPP 05-100-01. TAPE MUST BE CHECKED ONCE A DAY. WON'T EFFECT OPERATION OF RUDDER MOVEMENT. ** DL8360 SDR UALA2011060702789Idg · faultyL IDG DISCONNECT. FOUND MAINTENANCE MSG IN HISTORY: 24-31631 IDG L FREQUENCY IS LOW. ACCOMPLISHED FIM 24-11, TASK 805, INDICATES IDG REPLACEMENT. REMOVED L IDG. INSTALLED IDG ON LEFT ENGINE PER MM.SDR UALA2011060702788Gcu · faultyELEC GEN SYS L FAULTS. DUE TO RECENT HISTORY OF ELEC GEN SYS L FAULT, ACP FIM TASK 24-23-837. ACCOMPLISH FIM TASK INCLUDING WIRING CKS. INCLUDE OHMS AND CONTINUITY READINGS IN SIGNOFF. IF NO FAULTS ARE FOUND REPLACE THE RIGHT GCB (566-0549) PER AMM THE LESDR UALA2011042602022Terminal · damagedPACK FCV R ONE (BUT NOT BOTH) OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. REPAIRED GROUND TERMINAL AT VALVE. FLOW CONTROL VALVE OPERATION IS NOW NORMAL.SDR UALA2011042101930Cooling Fan · faultyLEFT EQUIPMENT COOLING SUPPLY FAN MSG. LEFT EQUIPMENT FAN INOP. REPLACED LEFT EQUIP COOLING FAN PER AMM.SDR UALA2011041501840Control Valve · faultyPACK FCV-L STATUS MSG. RPL'D LT UPPER FCV, OPS CKS GOOD & TESTS PASSED.SDR UALA2011041101721Cooling Fan · failedEQUIP COOLING FAN R ELECTRICAL EQUIPMENT COOLING AIR SUPPLY FAN 2 IS FAILED OR INOP. REPLACED EQUIPMENT COOLING FAN IAW MM. RPL EQUIP COOLING DUCT PRESSURE SENSOR AND EQUIP COOLING AIR FILTER. OPS CKS OKAY.SDR UALA2011031401206Connector · looseSEAT ROW 2E AND 2F ALL 4 EMERGENCY LIGHT INOP. FOUND CONNECTOR LOOSE AT SEAT 2E AND REPLACED LIGHTS AT SEAT 2F, ALL LIGHTS OP CHECK GOOD.SDR UALA2011031401191Engine · crackedNR 1 ENG FOUND RADIAL CRACKS IN AREA "A" OF HPT. CURRENTLY ON INTVL NR 3, RVI PIX POSTED. ENGINE CHANGE REQUIRED. WIDE LOAD CA TRUCK PERMIT NOT AVAIL WEEKENDS. ENGINE ETA 17MAR 1400. OLD ENG OFF. FIREWALL READY FOR ENG. INSTALLED NEW ENGINE.SDR UALA2011012600431Computer · malfunctionedON PRE-FLIGHT STATUS MESSAGE GROUND PROX SYS. RESET GPWC, NO HELP. DEFER IAW MEL, NOTIFIED DD. REPLACED GPWC IAW MM34-46- 01.SDR UALA2011012400378Light · inoperativeSEAT MOUNTED EMERGENCY LIGHT INOP, SEAT 3E. SEAT 3F EMERGENCY LIGHTS CHECKED OK. REPLACED SEAT 3E EMERGENCY LIGHT AND CHECKED OK.SDR UALA2010122704711Pressure Sensor · malfunctionedSTATUS MESSAGE WAI PRESSURE SENSOR RT DISPLAYED. MX MESSAGE:30-10220. CONFIRMED WAI-R VALVE OPS CHECKED OK. REPLACED RT WAI PRESSURE SENSOR, NO HELP. REPLACED RT WAI PRESSURE SENSOR IAW MM. ACP OPS CHECK OF WAI USING MAT AND MM.SDR UALA2010092103514Generator · inoperativeGENERATOR INOPERATIVE.SDR UALA2010082303113Module · faultyFOUND C2 TRU STATUS MSG ON LOWER EICAS. IAW MM MSG 24-13058 WORKED THRU FIM 24-32- TASK 810 C.4.F. WIRING CHECKS GOOD FROM TRU TO D31012P. ACP FIM 24-32-810 WIRING CHECKED NORMAL. REPLACED SIGNAL CONDITIONING CARD M24412 IN THE P310 PANEL IAW MM. INSTALLEDSDR UALA2010081602989Wire · brokenWATER PRESSURE PROBLEM. FOUND CABLE BROKEN ON PRES ELECT OVERFLOW VALVE. PUT VALVE IN CLOSED POSITION. ALL WATER PSI CHECKS OK IAW MEL.SDR UALA2010072302631Idg · faultedELEC GEN OFF AND DRV DISCONNECT RT MESSAGES. IDG FOUND FAULTY. REPLACED NR 2 ENG IDG, ALL TESTS NORMAL.SDR UALA2010072002594Transformer · faultyPRIOR TO DEPT STATUS MSG TRU C2 MSG. FOUND TRU C2 NOT CHARGING. REPLACED TRU. PERFORMED OPS CHECK, MSG CLEARED.SDR UALA2010071202457Tru · faultyELEC TRU C2 TRANSFORMER RECTIFIER C2 FAILED. STATUS MSG01- NOT ACTIVE CLIMB INTERMITTENT; TRANSFORMER-RECTIFIER UNIT (TRU C2) IS INOPERATIVE. DB- ELMS P310 ELECTRONICS UNIT MSG-2413058 INACTV CL INTER. REPLACED C2 TRU IAW MM. DC-STBY PWR SYS TEST PASSED.SDR UALA2010061502112Line · leakingNR1 ENG HYD TUBES HAVE EVIDENCE OF LEAKING. REPLACED PRESSURE, CASE DRAIN, AND RETURN HOSES ON NR 1 ENG EDP.SDR UALA2010050601543Tube · cokedNR 1 ENG HAS SEVERE COKING AROUND THE NR 3 BEARING BREATHER TUBE. PERFORM BORESCOPE INSP OF NR 3 BEARING WEEP (VENT) TUBE REF MM. NR 1 ENGINE BORESCOPE INSP OF NR 3 BEARING BREATHER TUBE LB3, NO SIGNS OF COKING. ACP BORESCOPE OF NR 3 BEARING WEEP TUBE, NO BLOSDR UALA2010041401256Panel · looseSEAT 2F PANEL NEAR FLOOR WILL NOT CLOSE CAUSING TRIPPING HAZARD. REPLACED VELCRO TAPE, OPS CHECKED GOOD.SDR UALA2010041401254Battery · faultyWHEN DOOR 3R IS ARMED THE EXIT SIGNS ILLUMINATE AT DOOR 3L-R AND 4L-R. REPLACED BATTERY AND POWER SUPPLY, RESTORED SYS.SDR UALA2010022200656Pump · faultyABOUT ONE HOUR AFTER TAKEOFF FUEL IMBALANCE MSG WITH CENTER PUMPS ON. PUMP FOUND DEFECTIVE. REPLACED CTR TANK LEFT OVERRIDE FUEL PUMP, OPS AND LEAK CHECKS GOOD.SDR UALA2010022200647Display · faultySMOKE OBSERVED FOR ONE MINUTE FROM VIDEO SCREEN AT 22H NO RECURRENCE. FOUND VIDEO DISPLAY INOP AT 22H. NEED TO REPLACE VIDEO DISPLAY ASSY. ROBBED DISPLAY FROM SEAT 25C, MOUNTED AT SEAT BACK OF 24C AND NO HELP. REPLACED 22H MONITOR, OPS CKS GOOD.SDR UALA2009120703781Terminal Block · damagedMID GALLEY EMERGENCY LIGHT TERMINAL BLOCK IN COMPARTMENT 300, BROKEN WITH WIRES HANGING DOWN. REPLACED GALLEY EMERGENCY LIGHTS TERMINAL BLOCK.SDR UALA2009120703786Satcom · malfunctionedSATCOM STATUS MSG AND EICAS DISPLAYED. REPLACED SATCOM DATA UNIT, BITE TEST OK.SDR UALA2009102803376Fan · odorCREW REPORT ODOR IN AND AROUND 2L AND VIDEO CABIN AREA. OPENED CABIN CEILING AT 2R&2L, RUN APU AND BOTH ENG WITH PACKS ON & GALLEY LOADED WITH OVEN, C-F MAKER, CHILLER, CABIN HEAT UP TO 85 DEGREE, CAP & F/O SHOULDER HEAT & FLIGHT DECK REST AREA HEATER. COULDSDR UALA2009101603244Duct · dirtySMOKE IN COCKPIT AND BUNKIE SMOKE ALARMS ACTIVATED WHEN AT FL320 AND LEFT PACK OFF AND TEMP CONTROLS TO FULL WARM. COULD NOT DUPLICATE WHEN AT 10000FT. WHEN REPEATING TESTS WITH RIGHT PACK OFF, THERE IS MUCH LESS SMOKE AND BUNKIE SMOKE ALARM DOES NOT ACTIVASDR UALA2009101203202Heater · odorLEFT PACK RUNNING OIL ODOR IN COCKPIT. ACP'D POWER RUN OF BOTH ENGINES, OPERATED PACKS TO ISOLATE SOURCE OF ODOR. FOUND ODOR PRESENT ONLY WHEN LEFT TRIM AIR SELECTED ON AND HEAT DEMANDED. CONDITION EXISTS REGARDLESS OF AIR SOURCE. ODOR NOT PRESENT WITH RIGSDR UALA2009100103086Heater · faultyELECTRICAL SMOKE ODOR. TURNED OFF BUNK HEATER, ODOR WENT AWAY. HEATER NOT TO BE USED. OPS GOOD, NO ELECTRICAL ODOR.SDR UALA2009090402786Light · unsecureTHE 2F EEL LIGHT LOOSE, HANGING DOWN. SECURED LT ASSY, OPS CHECKED OK.SDR UALA2009082402605Filter · faultySTRONG ODOR IN FLT DECK AND CABIN ON ARRIVAL (FL260). OPERATED BOTH PACKS, UNABLE TO DUPLICATE PROBLEM. OUTBOUND CREW WILL OBSERVE AND LOG ANY FAULTS. AFTER TURNING OFF RECIRC FAN, A LIGHT AMOUNT OF HAZE/SMOKE APPEARED IN THE COCKPIT, AFTER REVIEWING WITH SSDR UALA2009082502658Extinguisher · dischargedLOWER FLIGHT CREW REST FIRE BOTTLE EXTINGUISHED INADVERTENTLY BY SECURITY AGENT, ASSOCIATED WITH STATUS MESSAGE: "BOTTLE CREW REST LOWER". REPLACED LLAR MODULE FIRE EXTINGUISHING BOTTLE. ALL TESTS PASSED.SDR UALA2009070601925Light · inoperativeEEL LIGHT ON END BAY OF SEAT 33G INOPERATIVE. RELAMPED EEL.SDR UALA2009070601924Lamp · inoperativeEMERGENCY LIGHT ON END BAY OF SEAT 36G INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR UALA2009070601923Lamp · inoperativeEMERGENCY LIGHT ON SEAT END BAY AT 21C INOPERATIVE. RELAMPED EMERGENCY LIGHT.SDR UALA2009070601926Light · inoperativeEEL LIGHT ON END BAY OF SEAT 2F INOPERATIVE. ONE LIGHT INOP ON SEAT 2F. REPLACED EEL LIGHT, OPS CHECKED GOOD.SDR UALA2009062301774Precooler · splitNR 2 ENGINE PRECOOLER HAS A LARGE SPLIT ON THE LOWER INBOARD SIDE. REPLACED PRECOOLER, OP CHECKS GOOD.SDR UALA2009033100935Charger · dischargedAPU WILL NOT START. FOUND BATTERY CHARGER C/B POPPED. REPLACED APU BATTERY CHARGER. ALSO REPLACED APU BATTERY. APU STARTS AND OPS CHECKS NORMAL.SDR UALA2009032500884Clevis · wornNR 2 ENGINE AFT ENGINE MOUNT OUTBOARD CLEVIS HAS A WORN AREA ON INNER, AFT SURFACE. CONTINUED INSTALLATION OF AFT ENGINE MOUNT. NEED TO COMPLETE TORQUE AND SAFETY OF ALL MOUNT BOLTS.
Back to N218UA