N218UA
Service difficulty reports · 170
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N218UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N218UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2008120906792Lamp · inoperativeSEAT 36G AISLE EMERGENCY LIGHT INOP. REPLACED LAMP. OPS CHECKED OKAY.SDR UALA2008120906791Lamp · inoperativeSEAT 32G AISLE EMERGENCY LIGHT INOP. REPLACED LAMP. OPS CHECKED OKAY.SDR UALA2008112006574Relay · faultyNO LAND 3 DEGRADATION IN AUTOLAND SYS PRIOR TO APPROACH (BEFORE LAND 3 AUTOLAND STATUS ANNUNCIATION). AUTOLAND SYS IS NO LONGER FAIL-OPERATIONAL. ADVISORY MSG01- ACTIVE CRUISE MODE DEPENDENT; BUS ISOLATION IS NOT AVAILABLE. DB- AUTOPILOT FLIGHT DIRECTOR COMPUSDR 2008UALA06299Electrical Sys · malfunctionedFLIGHT REPORTED ELECTRICAL PROBLEM. FLIGHT DIVERTED.SDR 2008UALA06131Shutoff Valve · faultyPRESSURIZATION PROBLEM. FLIGHT DIVERTED. SUSPECT FAULTY FCSOV. REPLACED RIGHT UPPER AND LOWER FLIGHT CONTROL SHUTOFF VALVE. RAN ENGINES. NO PROBLEMS FOUND. ALL OPS NORMAL.
SDR 2008UALA05395Carbon Seal · leakingLT ENG LEAKING OIL. FOUND DRAIN LINE 10 LEAKING PAST LIMITS. REPLACED LEFT ENG IDG AND CARBON SEAL MM 24-11-11-01 AND 72-61-04. ACP ENG RUN AND LEAK CHECK, NO LEAKS NOTED.SDR 2008UALA03710Unknown · unknownRUNNING OUT OF WATER AND LAVS SHUTTING DOWN. FLIGHT DIVERTED.SDR 2008UALA03402Idg · faultyELEC GEN SYS R IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; INTEGRATED DRIVE GENERATOR (R) FREQUENCY IS LOW. DB- GENERATOR CSDR UALA2008111303097Connector · defectiveTHE LT OUTBOARD REFUEL VLV INOP. REPLACED CONNECTOR DV28108 REF WD 28-21-21 ON ACCOUNT OF INTERNALLY SHORTED WIRES 2 AND 5. REPLACED REFUEL VALVE CONTROL UNIT.SDR 2008UALA03097Valve · inoperativeLEFT OUTBOARD REFUEL VLV INOP.SDR 2008UALA02979Controller · malfunctionedRIGHT ENG BLEED SYSTEM HAS LARGE PRESSURE FLUCTUATIONS WITH ASSOCIATED ENG PARAMETER FLUCTUATIONS IN CLIMB AND IN CRUISE. WITH RIGHT PACK SELECTED -OFF- THE PRESSURE AND ENG PARAMETERS ARE STABLE. REPLACED ASCPC FOR RT AIR SUPPLY. ASCPC INSTALLED AND CABIN PSDR 2008UALA01193Shaft · shearedFOUND BACKUP GENERATOR (L) HAS A SHEARED SHAFT.SDR 2008UALA01158Light · looseEMERGENCY SIDE LIGHT AT SEAT 2E LOOSE. SECURED EMERGENCY SIDE LIGHT.SDR 2007UALA04947Blade · damagedNR 2 ENG HAS HPT STG 1 BLADE TRAILING EDGE BREAKTHROUGH INTO INTERNAL CAVITY. 1 BLADE TRAILING EDGE BREAKTHROUGH INTO INTERNAL CAVITY. REPLACED WITH ESN 222175 IN POS 02. PER TOD AMM 71-00-02 CONFIG 2 FIG 422.SDR 2007UALA04945Seal · damagedDURING A-CHECK SERVICE OF NR 1 IDG, FOUND IDG LEVEL LOW. FOUND EVIDENCE OF INPUT SHAFT SEAL OF IDG LEAKING. INPUT SHAFT SEAL OF IDG LEAKING. REPLACED IDG. AC OK FOR SERVICE.SDR 2007UALA02747Connector · mispinnedFWD BUSINESS CLASS CABIN HAS STRONG ELECTRICAL ODOR. [08-14-07] SUSPECT ONE OF ELEC UNIT UNDER SEAT ROW 9FED CREATED THE ODOR. DEACTIVATED ALL ELEC. UNIT AT THIS SEAT ROW. RECONNECTED VIDEO CONNECTIONS UNDER SEATS 8 DE&F, 9 DE&F, OPS CHECKED SYSTEM FOR ABOSDR 2007UALA00838Light · missingAFT SEAT MOUNTED EMERGENCY LIGHT AT SEAT 2E IS MISSING. REPLACED AFT SEAT 2E EEL LIGHT ASSY. EEL LIGHTING SYSTEM CHECKS OKSDR 2006UALA01850Engine · vibrationHIGH N2 VIBRATION ON NR 2 ENGINE. ONE HPT STAGE-2 BLADE HAD CORDWISE AIRFOIL FRACTURE AT THE MID-SPAN. THIS WAS THE RESULT OF INTERNAL SULFIDATION THAT CHOKES-OFF COOLING AIR FLOW WITHIN THE BLADE AIRFOIL. THIS RESULTS IN OVERHEATING OF THE PARENT MATERIAL SDR 2005UALA00259Valve · stuckLEFT ENG ANTI-ICE VALVE STUCK CLOSED. MAINTENANCE REPLACED LH ENGINE ANTI-ICE VALVE. OP CHECKED OK AFTER REACTIVATING VALVE.SDR 2004UALA00644Power Unit · malfunctionedPRIM EXT POWER ACCEPT NORMALLY, BUT SEC EXT POWER WON'T ACCEPT. WHENEVER PROVIDE TO SEC EXT POWER, GROUND POWER WILL TRIP BY OVER OR UNDER VOLTAGE. SEC EXT PWR CABLE TERMINALS SHORTED BETWEEN PHASES A & B, LOCATED ON INTERNAL SIDE OF PWR RECEPTACLE. MAY H