N219WN
Service difficulty reports · 301
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021122052809Skin · delaminatedRIGHT WING-OTBD TRAILING EDGE -AFT FLAP-DELAMINATED AT INBD END. REMOVED AND REPLACED R/H OUTBOARD AFT FLAP PER MM 27-51-12SDR SWAA2021062887708Cover · looseEMERGENCY EXIT SIGN#2OVERWING FELL OFF ; / [01] RE-INSTALLED EMERGENCY EXIT SIGN COVER IAW AMM 33-51-01SDR SWAA2021040560080Intercostal · crackedINTERCOSTAL AT CRACKED AT BS 344-BS 360; BL 0; WL 207.5 / REMOVED AND REPLACED INTERCOSTAL AT B.S344- B.S360; BL0 WL207.5 IAW SRM 51-40-02-0G-0 AND DWG 141A5400SDR SWAA2021040559122Lamp · inoperativeOVERWING INTERIOR EMERGENCY LIGHTS HAVE BURNED OUT BULBS / REMOVED; REPLACED AND PERFORMED GOOD OPS CHECK OF ALL INOP OVERWING INTERIOR EMERGENCY EXIT SIGN LIGHT LAMPS PER AMM 33-51-01-960-801 STEP 2.B.(1)(A) AND 2.B.(1)(C) AND 2.B.(2).SDR SWAA2021040559121Lamp · inoperativeR/H OVERWING EXTERIOR EMERGENCY EXIT LIGHT IS INOP / REMOVED; REPLACED; AND PERFORMED GOOD OPS CHECK OF R/H OVERWING EXTERIOR EMERGENCY EXIT (SLIDE) LIGHT LAMP PER AMM 33-51-04-960-801.SDR SWAA2021040559120Lamp · inoperativeAFT L/H ENTRY DOOR EXTERIOR EMERGENCY EXIT LIGHT IS INOP / REMOVED; REPLACED AND PERFORMED GOOD OPS CHECK OF AFT L/H ENTRY EXTERIOR EMERGENCY EXIT (SLIDE) LIGHT LAMP PER AMM 33-51-04-960-801.SDR SWAA2021040558825Connector · damagedEMERGENCY LIGHT COMMON TO FUSELAGE SKIN AT BS 757 JUST BELOW STR 21L CONNECTOR IS DAMAGED / REMOVED AND REPLACED CONNECTOR D11082 AT BS 757 PER SWPM 20-61-28. PERFORMED GOOD OPERATIONAL CHECK PER AMM 33-51-04-960-801 STEP 2.F(2)SDR SWAA2021040558482Attach Angle · crackedACB BS 947 RBL 45 WL 196 SIDEWALL UPPER ATTACH ANGLE CRACKED / REMOVED CRACKED ACB SIDEWALL ATTACH ANGLE BS 887-947 RBL 45 RECIEVED SERVICABLE PART. LOCATED DRILLED & INSTALLED PER SRM 51-10-02-0G-0; SRM 51-40-02-0G-0 & DWG 149A9490SDR SWAA2021040556839Doubler · crackedREINFORCEMENT DOUBLER IS CRACKED ON FWD SIDE OF LOWER VAPOR BARRIER BS663 RBL26 WL154 / REMOVED REINFORCEMENT DOUBLER DAMAGED AND INSTALLED NEW REINFORMENT DOUBLER AT BS 663 RBL 6-25 WL 154 IAW SRM 51-40-02-0G-0 AND DWG 111A1001.SDR SWAA2021040556840Former · chafedFAIRING FORMER HAS CHAFE DAMAGE BS657 TO BS667 WL150 RBL28 / REMOVED AND REPLACED FAIRING FORMER BS657-BS667; WL150; RBL28 IAW SRM 51-40-05-0G-0 FIG 3+4; AND DWG 149A7216. WILL BE INSTALLED ON NRC U287789SDR SWAA2022030179122Strip · corroded***CORROSION*** ACB NUTPLATE STRIP BS 787-792 RBL 2 0 WL 156 / REPLACED ACB NUTPLATE STRIP BS 787-792 RBL 20 WL 156 PER SRM 51-40-02-0G-0 AND DWG 146A0081SDR SWAA2022030179121Strap · corroded***CORROSION*** ACB FLOOR STRAP BS 767+7' LBL 22 WL 156 / RECEIVED NEW SERVICEABLE FLOOR STRAP ON SWA P.O. # 813290/1; NEW STRAP WILL BE INSTALLED ON SWA CARD # JPANEL-141-CLOSESDR SWAA2022030179123Strap · corroded***CORROSION***ACB FLOOR STRAP BS 887 LBL 7 WL 156 / RECEIVED NEW SERVICEABLE FLOOR STRAP ON SWA P.O.# 814641/1. NEW STRAP WILL BE INSTALLED ON SWA CARD # JPANEL-141-CLOSESDR SWAA2021040554788Web · corroded***CORROSION*** ACB WEB BS 767-787 RBL 6 WL 156 / REPLACED ACB WEB BS 767-787 RBL 6 WL 156 PO# 818018 PER SRM 51-40-02 AND DWG 146A8130 REV: B 59899U 17MAR21SDR SWAA2021040554790Web · corroded***CORROSION*** ACB WEB BS 787-807 RBL 6 WL 156 / CORROSION ON WEB FOUND OUT OF LIMITS DUE TO PROXIMTY TO FASTENER HOLES RECIEVED SERVICABLE WEB CUSTOMER P.O.# 81825C. LOCATED DRILLED & INSTALLED 787-807 RBL 6 WEB PER SRM 51-46-02-0G-0; SRM 51-40-05-0G-0; DWG SDR SWAA2021040554796Support Angle · corroded***CORROSION*** FORWARD CARGO BAY BULKHEAD SUPPORT ANGLE BS 500D RBL18 TO LBL18 WL156 / REPLACED FWD CARGO BAY BULKHEAD SUPPORT ANGLE BS 500D RBL 8 TO LBL 18 WL 156 PO # 818035 PER SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DWG 143A9485-35 AND DWG 143A9481SDR SWAA2021040555960Support · corroded***CORROSION*** ACB FLOOR TO BULKHEAD SUPPORT BS 947 RLB 20-LBL 8 WL 156 / REMOVED DAMAGED FLOOR TO BKD SUPPORT AND INSTALLED NEW FLOOR TO BKD SUPPORT BS 947 RBL 20 - LBL 10 WL 156 IAW SRM 51-40-02-0G-0 AND DWG 149A8110; 147A7500SDR SWAA2021040555961Support · corroded***CORROSION*** SIDEWALL TO BULKHEAD SUPPORT BS 947 RBL 21 WL 156 / REMOVED DAMAGED SIDEWALL TO BKD AND INSTALLED NEW SIDEWALL TO BKD SUPPORT BS 947 RBL 21-45 WL 156 IAW SRM 51-40-02-0G-0 & DWG 149A8110; 147A7500SDR SWAA2021040556630Support Angle · crackedACB BULKHEAD SUPPORT ANGLE BS 727+4' RBL 4 WL 162 IS CRACKED REMOVED AND REPLACED ACB BULKHEAD SUPPORT ANGLE BS 727+4; WL 162; RBL 4 IAW SRM 5140020G0; DWG# 144A2600SDR SWAA2021040554791Web · corroded***CORROSION*** ACB SUBTHRESHOLD WEB BS 792-847 RBL 25 WL 156 / REPLACED ACB SUBTHRESHOLD WEB BS 792-847 RBL 25 WL 156 PER SRM 51-40-05-0G-0; SRM 51-40-02-0G-0 AND DWG 146A8340SDR SWAA2021040556640Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS400 TO BS420 STR26L WL158 / REPLACED FCB INTERCOSTAL BS 400 TO BS 420 STR 26L WL 158 PO # 764707 PER DWG 143A7505 AND SRM 51-40-02-0G-0SDR SWAA2021040556641Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS500 TO BS500A STR26L WL158 / REPLACED FCB INTERCOSTAL BS 500 TO BS 500A STR 26L WL 158 PO # 812273/6 PER DWG 143A7505 AND SRM 51-40-02-0G-0SDR SWAA2021040556642Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS500C TO BS500D STR26L WL158 / REPLACED FCB INTERCOSTAL BS 500C TO 500D STR 26L WL 158 PER SRM 51-40-02-0G-0 AND DWG 143A7505SDR SWAA2021040554776Intercostal · corroded***CORROSION*** ACB INTERCOSTAL BS 747-767 RBL 22 WL 156 / CORROSION ON INTERCOSTAL WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER: SRM 53-00-04-1A-1. INTERCOSTAL IS A PART OF THE 146A7502-51 ASSY AND WAS REPLACED ON NRC U287962SDR SWAA2021040554778Intercostal · corroded***CORROSION*** ACB INTERCOSTAL BS 767787 RBL 22 W L 156 CORROSION DAMAGE EVALUATION PN 146A812320 ACB INTERCOSTAL ASSY BS767787; RBL 22; WL 156; WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO HOLES PER SRM 530004. REMOVED AND INSTALLED NEW ACB INTERCOSTAL SDR SWAA2021040556633Intercostal · crackedACB CRACKED INTERCOSTAL BS 927-947 RBL 21 WL 156 / REMOVED DAMAGED INTERCOSTAL AND INSTALLED NEW INTERCOSTAL AT BS 927-947 RBL 21 WL 156 IAW SRM 51-40-02-0G-0 AND DWGSDR SWAA2021040556634Angle · crackedACB CRACKED ANGLE BS 947 LBL 10 WL 156 / REMOVED DAMAGED ANGLE AND INSTALLED NEW ANGLE AT BS 947 LBL 10 WL 156 IAW SRM 51-40-02-0G-0 AND IPC 53-42-51-03SDR SWAA2021040556635Stiffener · crackedLT HORIZ. STAB RIB AT STAB STA 92.70 1ST VERT STIFFENER IS CRACKED. / REPAIRED LT HORIZ. STAB RIB AT STAB STA 92.70 1ST VERT. STIFFENER IAW SRM 55-10-09-2R-4.SDR SWAA2021040556639Stiffener · crackedRT HORIZ. STAB RIB AT STAB STA 129.50 4TH VERT STIFFENER IS CRACKED. REPAIRED RT HORIZ. STABILIZER RIB AT STAB STA 129.50 4TH VERT STIFFENER IAW SRM 5510092R4. 59796C 15MAR21.SDR SWAA2021040556638Stiffener · crackedLT HORIZ. STAB RIB AT STAB STA 129.50 4TH VERT STIFFENER IS CRACKED. / INSTALLED REPAIR LEFT HORIZONTAL STABILIZER RIB STAB STA 129.50 4TH VERTICAL STIFFENER IAW SRM 55-10-09-2R-4SDR SWAA2021040556637Stiffener · crackedLT HORIZ. STAB RIB AT STAB STA 129.50 2ND VERT STIFFENER IS CRACKED. / REPAIRED LT HORIZ STAB RIB AT STAB STA 129.50 2ND VERTICAL STIFFENER IAW SRM 55-10-06-2R-4. 59796C 15MAR21SDR SWAA2021040556636Stiffener · crackedLT HORIZ. STAB RIB AT STAB STA 92.70 3RD VERT STIFFENER IS CRACKED. / REPAIRED LT HORIZONTAL STAB RIB AT STAB STA 92.70 3RD VERTICAL STIFFENER IAW SRM 55-10-09-2R-4. 59796C 15MAR21SDR SWAA2021040554801Angle · crackedFORWARD CARGO BAY CRACKED CLIP AFT SIDE OF THE FRAME BS400 LBL21 WL158 / REPLACED FCB CLIP AFT SIDE OF THE FRAME BS 400 LBL 21 WL 158 PER SRM 51-10-02-0G-0 AND DWG 143A7505SDR SWAA2021040556631Angle · crackedACB CLIP CRACKED BS 827 RBL 19 WL 156 REPLACED ACB CLIP BS 827 RBL 19 WL 156 PO# 817763 PER SRM 5140020G0 AND DWG 146A8120SDR SWAA2021040554787Support Angle · corroded***CORROSION*** ACB SHIELD SUPPORT ANGLE BS 767-787 RBL 22 WL 156 / CORROSION DAMAGE EVALUATION ON ACB SHIELD SUPPORT ANGLE BS 767-787; RBL 22; WL 156 WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN SRM. NEW ACB SHIELD SUPPORT ANGLE WILL BE REPLACED ASSDR SWAA2021040554799Shield · corroded***CORROSION*** FORWARD CARGO BAY SHIELD BS492 TO B500A RBL 23 WL156 / REMOVED AND REPLACED FCB SHIELD BS 492 TO BS 500A RBL 23 WL 156 I.A.W SRM 51-40-02-0G-0 AND DWG 143A0080 REV:-SDR SWAA2021040554800Web · corroded***CORROSION*** FORWARD CARGO BAY SUB THRESHOLD WEB BS449 TO BS480 RBL 25 WL156 / CORROSION ON FWD CARGO BAY SUB THRESHOLD WEB BS 449-480; RBL 25; WL 156 FOUND OUT OF LIMITS DUE TO PROXIMITY TO HOLES PER SRM 53-30-15-1A-1 FIG 103 DETAIL D. REMOVED WEB; LOCATEDSDR SWAA2021040554773Support · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 727+4' TO 767 RBL 21 WL 156 / CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE PRIXCIMITY TO FASTENER HOLES PER: SRM 53-00-53-1A-2. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02 AND DRAWING 146A7500SDR SWAA2021040554777Shield · corroded***CORROSION*** ACB SHIELD BS 767-792 RBL 22 WL 156 / CORROSION DAMAGE EVALUATION ON ACB SHIELD P/N 146A8127-12 WAS FOUND TO BE OUT OF LIMITS. DUE TO NO LIMITS GIVEN IN SRM. REMOVED AND INSTALLED NEW ACB SHIELD BS 767-792; RBL 22; WL 156. PER DWG 146A0081. ANDSDR SWAA2021040554780Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' RBL 8 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER SRM 51-40-02 (737-700) AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554781Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' RBL 3 WL 156 / FOUND OUT OF LIMITS DUE TO NO LIMITS (SRM.) REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3SDR SWAA2021040554782Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 3 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554783Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 8 WL 156 / FOUND OUT OF LIMITS DUE TO NO LIMITS. (SRM) REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3SDR SWAA2021040554784Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 13 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554798Shield · corrodedCORROSION FORWARD CARGO BAY SHIELD BS420TO BS 440 RBL 23 WL156 REMOVED AND REPLACED FORWARD CARGO BAY SHIELD ASSY BS 420 BS 440 RBL 23; WL 156 PER SRM 514005; 514002 AND DWG # 143A0080 REVSDR SWAA2021040554774Support · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 727+4' TO 847 LBL 21 WL 156 / REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT BS 847-927 LBL 21 WL 156 IAW SRM 51-40-02-0G & DWG 146A7500 AND 149A8102SDR SWAA2021040554785Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 17 WL 156 /SDR SWAA2021040554797Support · corroded***CORROSION*** FORWARD CARGO BAY L/H FLOOR TO SIDE WALL SUPPORT BS400 TO BS500D LBL 21 WL156 / REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT BS 396 - 500D LBL 21 WL 156 IAW SRM 51-40-02-0G-0 & DWG 284A0603SDR SWAA2021040554802Angle · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 88 7' TO 947 RBL 21 WL 156 / REMOVED FLOOR TO SIDEWALL SUPPORT DAMAGED AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT ANGLE AT BS 887-947 RBL 21 WL 156 IAW SRM 51-40-02-0G-0 AND DWG 147A7500SDR SWAA2021040554803Frame Angle · corrodedCORROSION ACB BS947 FRAME CLIP LBL8; WL175. REMOVED DAMAGED FRAME CLIP AT BS 947 LBL 8 WL 175 AND INSTALLED NEW FRAME CLIP IAW SRM 5140020G0 AND DWG 147A1047.
Back to N219WN