N222UA
Service difficulty reports · 154
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N222UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N222UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101620432Battery · no testLLAR EMERGENCY LIGHT BATTERY TEST FAILED. EMERGENCY LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2026101620430Battery · no testDOOR 4R M33409 EMER LT BATTERY TEST FAIL. EMERGENCY LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2026101620428Battery · no testL1 DOOR EMER LIGHT POWER SUPPLY M33093 TEST FAILED. POWER SUPPLY BATTERY REPLACED & TESTED NORMAL IAW AMM33-51-06.SDR CALA2026101620426Charger · no testDR 2R M33098 EMER LT BATTERY CHARGER TEST FAIL. EMERGENCY BATTERY CHARGER REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2026101620424Battery · no testR4 DOOR EMER LIGHT POWER SUPPLY M33408 TEST FAILED. EMER LT PWR SUPPLY BATTERY REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2026101620422Battery · no testSUPPORT TASK - L4 DOOR EMER LIGHT POWER SUPPLY M33407 TEST FAILED. TRANSFER NON-ROUTINE HX WO.7336103 AND ORIGINATED BY V943251 DOOR 4L M33407 EMERGENCY LIGHT BATTERY TEST FAILED AND BATTERY REPLACED DR 4L M33407 EMER LT PWR SUPPLY BATT REPLACED AND TESTED NORSDR CALA2026101620420Charger · no testL3 DOOR, EMERGENCY LIGHT BATTERY CHARGER TEST FAILED. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2026101620418Charger · no testL2 DOOR, EMERGENCY LIGHT BATTERY CHARGER TEST FAILED. CHARGER REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026101620415Charger · no testL2 DOOR, EMERGENCY LIGHT BATTERY CHARGER TEST FAILED. BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026041715435Battery Pack · inoperativeALL OF FIRST-CLASS EMERGENCY FLOOR PROX LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT DOOR 1R. EMERGENCY LIGHTS OPS CHECK GOOD. REF AMM 33-51-06-960-802.SDR CALA2026020613621Fire Detector · faultedSTATUS MSGS OVERHEAT CIRCUIT R1 & R2 FIRE LOOP 1/2 ENG R T/S REF FIMS 26-11 TASK 811 AND 26-11 TASK 809. FOUND NR 2 ENG DET 2: M26005 (LOWER AFT ENG) BROKEN OFF AT TERMINAL END ATTACH POINT AND DET 1: M26006 MISSING HARDWARE. REQUIRES DETECTOR 2 M26005 REPLACESDR CALA2025112611489Actuator · faultedDOOR FLIGHT LOCK 3R STATUS MESSAGE DUE TO HISTORY, COMPLIED WITH *DM* REF. MX FAULT MSG 52-11330 FIM 52-11 TASK 806 FOR FAULT ISOLATION, REPEAT WRITE-UP, AFTER FAULT ISOLATION, REMOVED AND REPLACED DOOR LOCK ACTUATOR IAW AMM 52-11-26-400-801 OPS TEST GOOD.SDR CALA2025102010288Battery Pack · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY PATH LIGHTS INOP IN SEAT 18G, 28G, AND 30D DUPLICATE WRITE UP. WORK PERFORMED ON LOG PAGE #6651473 DUPLICATE LOG PAGE. WORK PERFORMED ON LOG PAGE #6651473SDR CALA2025102010285Module · inoperativePOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY PATH LIGHTS INOP IN SEAT 18G, 28G, AND 30D REPLACED FLOOR PROXIMITY LIGHT ASSEMBLY ON SEAT 18G, 28G, AND 30D REFER AMM 33-51-05. OPS CHECK GOOD.SDR CALA2025102010281Battery Pack · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY BATTERY PACK FOR EMERGENCY POWER SUPPLY M33098 OVERDOOR 2R FAILED FUNCTIONAL TEST REPLACED BATTERY PACK AT POWER SUPPLY M33098 OVERDOOR 2R. OP CHECK GOOD REF AMM 33-51-06. OP CHECK GOODSDR CALA2025100709751Skin · ground damageAIRCRAFT AFT FUSALAGE CONTACTED LAV TRUCK AT LAV SVC HATCH. MULTIPLES DENTS AREAS AROUND LAV SERVICE DOOR ON THE STRINGERS THAT REQUIRED OPEN UP FOR FURTHER INSPECTION FOR DAMAGE. REF. SRM 53-00-01-1A-1. SEE ATTACHED PHOTOS FOR LOCATION OF DAMAGE. SKIN AND SDR CALA2025100609636Stringer · dentedREF. LOG PAGE # 6361899 STRINGER 49R IS DAMAGED BETWEEN STA. 1958 AND STA. 1979CUT OUT DAMAGED SECTION OF STRINGER REF. SRM 53-70-03-2R-1 REPAIR 1 PARAGRAGH 4.C. REQUEST ON INSPECTOR PERFORM HFEC INSPECTION OF CUT EDGES AND ALL INITAL FASTENER HOLES IN REPAIRSDR CALA2025030300469Battery Pack · no testSUPPORT TASK - CABIN DR R3 EXIT SIGN FOUND DIM DURING DEEP CYCLE (POWER FROM EMER PWR PACK M33404). WORK TRANSFER NON ROUTINE WO.4474384. CABIN DR 3 EMER LT POWER BATTERY PACK (M33404) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33SDR CALA2025030300468Battery Pack · no testSUPPORT TASK - CABIN DR R2 EXIT SIGN FOUND DIM DURING DEEP CYCLE (POWER FROM EMER PWR PACK M33097). WORK TRANSFER NON ROUTINE WO.4474373. CABIN DR R2 EMER LT POWER BATTERY PACK ( M33097) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM SDR CALA2025030300467Battery Pack · no testSUPPORT TASK - CABIN DR L2 EXIT SIGN FOUND DIM DURING DEEP CYCLE (POWER FROM EMER PWR PACK M33096). WORK TRANSFER NON ROUTINE WO.4474361. CABIN DR L2 EMER LT POWER BATTERY PACK ( M33096) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM SDR CALA2025030300466Battery Pack · no testSUPPORT TASK - LLAR BACK-UP LIGHT FOUND DIM DURING DEEP CYCLE (POWER FROM PWR PACK M023). WORK TRANSFER NON ROUTINE WO.4474388. LLAR EMER LT POWER BATTERY PACK ( M023) REPLACED AND INSTALLATION TEST CARRIED OUT WITH RESULT NORMAL AS PER AMM 33-51-06.SDR CALA2025022800464Battery Pack · dischargedSUPPORT TASK - CABIN DR L3 FWD EXIT IDENTIFIER FOUND DIM DURING DEEP CYCLE (POWER FROM EMER PWR PACK M33400). WORK TRANSFER NON ROUTINE WO.4474375 AND ORIGINATED BY EMP V920592. CABIN DR L3 EMER LT POWER BATTERY PACK ( M33400) REPLACED AND INSTALLATION TEST CASDR CALA2024101800859Battery · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - EMERGENCY LIGHTS AT 2L DOOR (INSIDE) AND FWD MID GALLEY GO OUT AFTER A FEW MINUTES REPLACED BATTER AT POWER SUPPLY M33096 PER AMM 33-51-06-960-802 CK OK POWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURESDR CALA2024101800858Battery · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - 1L DOOR SLIDE LIGHT (EXTERIOR) INOP R&R BATTERY PACK FOR EMERGENCY POWER SUPPLY M33424 REF AMM 33-51-06-960-802. OPS CHECK GOOD PARTS USED: 99-3351-3-0015,QTY :1SDR CALA2024101800857Battery · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - 1R DOOR SLIDE LIGHT AND ASSOCIATED INTERIOR LIGHTS INOP REPLACED BATTERY PACK AT POWER SUPPLY M33094 PER 33-51-06-960-802 CK REPLACED BATTERY PACK AT POWER SUPPLY M33094 PER 33-51-06-960-802 CK OK PARTS USSDR CALA2024101800856Battery Pack · no testPOWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - 3R DOOR SLIDE AND ASSOCIATED INTERIOR LIGHTS INOP REPLACED BATTERY PACK AT POWER SUPPLY M33401 REF AMM 33-51-06-960-802 CK OK PARTS USED: AD-D717-01-100,QTY :1SDR CALA2024101702667Panel · brokenPDA 1 PANEL 196JR DEPARTED AC UPON LANDING AND DAMAGED PANEL 198JR. PANEL FOUND ON RUNWAY AFTER LANDING IN HNL. REF LP 9565702 REMOVED REMAINING HINGES ATTACHED TO THE PLANE PER AMM 53-46-01-000-801. FOUND FOLDING STRUT FITTING ASSEMBLY DAMAGED (CRACKED). REMOSDR CALA2024072900305Pump · failedFUEL SCAVENGE PUMP FAIL INFLIGHT FAULT HISTORY SHOWS "CENTER TANK FUEL SCAVENGE WAS NOT COMPLETED". THIS OCCURED ON THE 22 AND 24TH JULY. MAINTENACE MESSAGE IS 28-11081. REF FIM 28-22 TASK 901. CHECKED FAULT HISTORY, FOUND MAINT MESSAGE HIT ON PREVIOUS LEG. CESDR CALA2023103003234Battery Pack · dischargedEMER LT BATTERY PACK AT DR 2R FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295789, ORIG BY V920586 EMER LT BATTERY PACK AT DR 2R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2023103003232Battery Pack · dischargedEMER LT BATTERY PACK AT DR 3L FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295784, ORIG BY V920586 EMER LT BATTERY PACK AT DR 3L REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023103003230Battery Pack · dischargedEMER LT BATTERY PACK AT DR 4R FOUND CAPACITY FUNCTION CHECK FAIL (M33409) REF HX NR WO.2295764, ORIG BY V920586 EMER LT BATTERY PACK AT DR 4R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 (M33409) ACCOMPLISHED BY MECH V920586, INSP V896992SDR CALA2023103003228Battery Pack · dischargedEMER LT BATTERY PACK AT DR 3R FOUND CAPACITY FUNCTION CHECK FAIL REF HX NR WO.2295839, EMER LT BATTERY PACK AT DR 3R REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2023103003226Battery Pack · dischargedEMER LT BATTERY PACK (M33099) AT DR 2L FOUND CAPACITY FUNCTIONAL CHECK FAIL REF HX NR WO.2295826, ORIG BY V920586 EMER LT BATTERY PACK AT DR 2L REPLACED AND INSTALLATION TEST RESULT NORMAL IAW AMM 33-51-06 (M33099)SDR CALA2023061601868Light · inoperativeFOUND PAX SEAT 20G 21G 22G 32G FLOOR PROXIMITY LIGHT LAMPS INOP - ORIGINATED BY EMP V916788 ON HAECO NR 9461070, SUPPORT TASK. PERFORMED BY EMP V903179, IDT BY V903189. REPLACED THE PAX SEAT 20G 21G 22G 32G FLOOR PROXIMITY LIGHT ASSY AND PERFORMED OP TEST FOUNSDR CALA2023061601867Battery · failedFOUND R3 DOOR SECTIONS OF EMERGENCY LIGHTS INOP - ORIGINATED BY EMP V916788 ON HAECO NR 9461070, SUPPORT TASK. PERFORMED BY EMP V903179, IDT BY V903189. PERFORMED T/S FOUND M3 3405 POWER SUPPLY BATTERY PACK FAILED, REPLACED THE BATTERY PACK AND PERFORMED OP TESDR CALA2023061601866Battery · failedFOUND R2 DOOR SECTIONS OF EMERGENCY LIGHTS INOP - ORIGINATED BY EMP V916788 ON HAECO NR 9461070, SUPPORT TASK. PERFORMED BY EMP V903179, IDT BY V903189. PERFORMED T/S FOUND M3 3098 POWER SUPPLY BATTERY PACK FAILED, REPLACED THE BATTERY PACK AND PERFORMED OP TESDR CALA2022010700054Battery Pack · inoperativeB777-33-3-7031 - SEAT 47-53 - AND AFT GALLY FWD PARTITION AREA EMER LT FOUND DIM. EMER LT POWER SUPPLY BATTERY REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2022010700042Battery Pack · dischargedB777-33-3-7031 - SEAT 27-36 AND CREW REST DOORWAY AREA EMER LT FOUND DIM - REFER TRANSFER NON-ROUTINE ZHA501993 AND ORIGINATED BY EMP V935378 M33404 EMER LT POWER SUPPLY BATTERY REPLACED AND TEST NORMAL AS PER AMM 33-51-06 ADD EMP:V896992 IDT INSPECTED OKAY BYSDR CALA2020072001064Battery Pack · dischargedR4 EMERGENCY BATTERY FAILED OPS CHECK ON T/C NO. 97-1011-1-6904 REMOVED AND REPLACED R4 BATTERY PACK P/N AD-D717-01-1 S/N 180833 REF 777 MM 33-51-06-960-802. OPS CHECK GOOD.SDR CALA2020021200401Bulb · inoperativeB777-33-3-7030 L/H NO.3 DOOR EXTERIOR EMER LT FOUND UNILLUMINATE REFER NR LP 9130048 L/H NO.3 DOOR EXTERIOR EMER LT REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-51-04 ADD EMP:V927706 IDT BY HX 195306SDR CALA2020020800369Light · malfunctionedB777-33-3-7030 R/H NO.4 DOOR EXTERIOR EMER LT FOUND ILLUMINTED REFER NR LP 9130049 R/H NO.4 DOOR EXTERIOR EMER LT REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-51-04SDR CALA2020020800368Battery Pack · inoperativeSUPPORT TASK LLAR EMER LT FOUMS UNILLUMINATED REFER NR LP 9131122 LLAR EMER LT CHARGER REPLACED AND OP TEST RESULT NORMAL AS PER AMM 33-29-01SDR CALA2020020800367Power Supply · inoperativeSUPPORT TASK DR R3 EMERGENCY LT PWR SUPPLY (M33401) INOP REFER NR LP 9131097 DR R3 EMERGENCY LT PWR SUPPLY (M33401) REPLACED AND OP TEST FOUND NORMAL AS PER AMM 33-51-06 ADD EMP:V896992SDR CALA2019042200634Engine · surges2822-2 ESN 222036 EXPERIENCED SURGE DURING TAKEOFF RUN AT 60KTS. ON RETURN TO GATE GRUMM REPORTED METAL IN TAILPUPE. ACCOMPLISH BORESCOPE INSPECT HPC STG 5,6,9,AND HPT STG 1 AND 2. REF AMM72-00-00 P6XX CFG2. IF SIGNS OF IMPACT, INSPECT OTHER STAGES. PERFORMEDSDR CALA2019020100201Engine · surgesE1 SURGE, DATA PRINT AND EMAIL. E1 SN 222210 (TSI=380 HRS). HAD A SILENT SURGE REPORTED BY AHM IN CRZ T/803-29 IAD-NRT. PLEASE SEND DATA FOR ENGINEERING REVIEW (1) REF AMM 31-61-00 PG201. ACCESS MCDU MAINT PGS CHAP71 PER. EPCS PG 1 & 2, AND L ENG EXCD. FIND ALSDR CALA2018070301569Battery · dischargedM/D LLAR EMER LT BATTERY 1EA FOUND LOW CAPACITY. REPLACED THE CABIN LLAR EMERGENCY LT PWR PACK BATTERY AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 83.SDR CALA2018070301568Light · brokenM/D MID GALLEY, 5EA LWR EMER LIGHTS FOUND BROKEN. REPLACED THE CABIN MID GALLEY 5EA LWR EMERGENCY LIGHTS AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-05-960-802 REV 83.SDR CALA2018070301567Light · brokenM/D A & B ZONE CTR PARTITION, 4EA LWR EMER LIGHTS FOUND BROKEN. REPLACED THE CABIN ZONE A & B CTR PARTITION TOTAL 4EA LOWER EMERGENCY LT AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33 -51-05-960-802 REV 83.SDR CALA2018070301566Light · brokenM/D A4 GALLEY LT 1EA LWR EMER LT FOUND BROKEN. REPLACED THE CABIN A4 GALLEY LT SIDE 1EA LWR EMERGENCY LIGHT AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-05-960-802 REV 83.SDR CALA2018070301553Lens · missingM/D DOOR 1 CTR PARTITION 1EA CTR LWR EMER LIGHT LENS FOUND MISSING. REPLACED THE CABIN DOOR 1 CTR PARTITION 1EA CTR LWR EMERGENCY LT AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-05-960- 802 REV 83.