What was found
STATUS MSGS OVERHEAT CIRCUIT R1 & R2 FIRE LOOP 1/2 ENG R T/S REF FIMS 26-11 TASK 811 AND 26-11 TASK 809. FOUND NR 2 ENG DET 2: M26005 (LOWER AFT ENG) BROKEN OFF AT TERMINAL END ATTACH POINT AND DET 1: M26006 MISSING HARDWARE. REQUIRES DETECTOR 2 M26005 REPLACEMENT AND DET 1 M26006 HARDWARE REPLACEMENT. INSTALLED MISSING FASTENERS AND REPLACED FIRE LOOP #2 REF AMM 26-11-01-400-805-002. UP TO CHECKS. PERFORMED ENGINE FIRE DECTECTION OPERATIONAL TEST, TASK 26-11-00-710-801. TEST PASSED, NO STATUS MSGS PRESENT. PERFORMED ENGINE FIRE DECTECTION OPERATIONAL TEST, TASK 26-11-00-710-801. TEST PASSED, NO STATUS MSGS PRESENT.