N2243U
Service difficulty reports · 34
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2243U' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2243U' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026031814654Battery Pack · no testTHE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 3L POWER SUPPLY M33303. REPLACED BATTERY PACK ON THE DOOR 3L POWER SUPPLY M33303, THEN PERFORMED INSTALLA TION TEST,THE RESULT WAS NORMAL IAW AMM 33-51-06-960-802 REV 106 .SDR CALA2026031814653Battery Pack · dischargedTHE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 1R POWER SUPPLY M33094.. REPLACED BATTERY PACK ON THE R1 DOOR POWER SUPPLY M33094, THEN PERFORMED INSTALLATION TEST, THE RESULT WAS NORMAL IAW AMM 33-51-06-960-802 REV 106.SDR CALA2026031814652Battery Pack · inoperativeTHE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 3R POWER SUPPLY M33304 REFER HAECO NON-ROUTINE 9451831. REPLACED BATTERY PACK ON THE DOOR 3R POWER SUPPLY M33304, THEN PERFORMED INSTALLATION TEST, THE RESULT WAS NORMAL IAW AMM 3SDR CALA2025091108776Light · brokenGALLEY M2 RIGHT SIDE EMER FLOOR PROXIMITY LIGHT HOUSING BROKEN AND LENS MISSING. R & R GALLEY M-2 RIGHT SIDE EMERGENCY PROXIMITY LIGHT ASSY AND TEST CHK OK.SDR CALA2025082007965Bulb · no testWING ILLUMINATION LIGHTS - OPERATIONAL TEST PROCEDURE - LEFT LANDING LIGHT BULB DOES NOT PROVIDE ILLUMINATION UPON REMOVAL OF BULB NOTICED TERMINALS TO BE SINGED AND EMITTING AN ODOR. INSPECTED LEFT WING LANDING LIGHT (L33115) WIRES. FOUND ON WIRE W5164-0056-1SDR CALA2025062005729Slide · low pressureWHILE PERFORMING #2 SVC CHECK FOUND L4 DOOR SLIDE PRESSURE OUT OF LIMITS REF AMM 25-66-01-200-801. L4 DOOR SLIDE NIS IN EWR, REF IPC 25-66-01-04A ITEM (50) P/N 63604-339 (M/E 23-2566-9-0002) REMOVED AND REPLACED L4 EMERGENCY ESCAPE SLIDE AS PER MM TASK 25-SDR CALA2025061705605Bottle · low pressureDOOR 4L SLIDE PRESSURE REPORTED BY CREW TO BE IN RED, BAND. ACCOMPLISHED DOOR 4L SLIDE PRESSURE INDICATION REF. TASK 25-66-01-200-801 ,NEDDLE TOUCHING GREEN AREA.SDR CALA2025012300183Battery · dischargedDR1 OVHD FLIGHT CREW REST EMER PWR PACK M33145 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.4339486 AND ORIG BY DR1 OVHD FLIGHT CREW REST EMER PWR PACK M33145 REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025012300182Battery · dischargedDR3 RH EMER PWR PACK M33305 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.4339489 AND ORIG BY DR3 RH EMER PWR PACK M33305 REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025012300181Battery · dischargedDR4 RH EMER PWR PACK M33404 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.4339488 AND ORIG BY DR4 RH EMER PWR PACK M33404 REPLACED AND TESTED NORMAL IAW AMM33-51-06SDR CALA2025012300180Battery · dischargedDR4 LH EMER PWR PACK M33400 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.4339487 AND ORIG BY DR4 LH EMER PWR PACK M33400 REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025012300179Battery · dischargedDR3 LH EMER PWR PACK M33302 CAPACITY LOW. DR3 LH EMER PWR PACK M33302 REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025012300178Battery · dischargedDR3 LH EMER PWR PACK M33301 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.4339493 AND DR3 LH EMER PWR PACK M33301 REPLACED AND TESTED NORMAL IAW AMM33-51-06.SDR CALA2025012200176Structure · crackedRH FRONT SPAR LWR CHORD 1EA HOLE FND 2EA CRACK INDICATION WING CTR TANK FRONT SPAR LWR CHORD MOD AT BOTH L/R BS1035 IAW EA5711-01165 REV C OP16SDR CALA2025010900073Light · brokenSEAT 31D FLOOR PROXIMITY LIGHT FOUND INOP. SEAT 31D FLOOR PROXIMITY LIGHT ASSY REPLACED AND TESTED NORMAL IAW AMM33-51-05.SDR CALA2024121901579Light · faultedFLOOR EMER LT ASSY BROKEN ON THE GALLEY DR 2. REPLACED EMER LT ASSY, OPS CHK GOOD.PARTS USED: 25-3327-3-0004, QTY :1SDR CALA2024041001027Wheel · fireFLAMES EXTIGUISHED AFT LDG GEAR BY EDDF FIRE BRIGADE. LOG FOR AFFECTED BRAKES (1,2,7,12) REMAINING WHEELS COOLED DOWN WITH AIRCOOLER. BRAKE 1 SMALL BRAKEFIRE, COOLED DOWN PER FIREGUARD WITH AIR AND WATERSPRAY HIGH ENERGY STOP INSPECTION PERFORMED PER AMM 05-5SDR CALA2024040200921Coupling · leakingALL LAVS LEAKING BROWN SEWAGE FROM SINKS.BIOHAZ ARD. FOUND BLOCKAGE AT WASTE LINE ELBOW INFRONT OF FWD DRAIN MAST. INNER COATING OF ELBOW IS DAMAGED AND CAUSING BLOCKAGE. FOR REF SEE IPC 38-31-53-81A ITEM 220 ELBOW HOSE M&E 99-3831-3-0025 MFG P/N BOE2013-0458SDR CALA2023050901424Battery Pack · no testB777-33-3-7019:NO LIGHT AT OFAR ENTRANCE AND LEFT SIDE BUNK EMER GENCY LIGHT DURING OPERATION TEST.FOUND EMERGENCY LIGHT BATTERY (M33143) INOPERATIVE.PN OFF:D717-01-100, SN OFF:433673. EMERGENCY LIGHT BATTERY PACK REPLACED AS PER AMM 33-51-00. INSTA LLATION TESDR CALA2023050901433Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 RIGHT (M33401) EMERGENCY LIGHT BAT TERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 155992 REPLACED DOOR 4 RIGHT EMERGENCY LIGHT BATTERY PACK M33401 AND IN WORK ACCOMPLISHED BY V943538 STALLATION TEST PASSED ASSDR CALA2023050901432Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 LEFT (CENTER M33406) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 434082 REPLACED DOOR 4 LEFT EMERGENCY LIGHT BATTERY PACK M33406 AND WORK ACCOMPLISHED BY V943538 INSTALLATION TEST PASSEDSDR CALA2023050901431Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 4 LEFT (AFT M33405) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 434096 REPLACED DOOR 4 LEFT EMERGENCY LIGHT BATTERY PACK M33405 AND INS WORK ACCOMPLISHED BY V943538 TALLATION TEST PASSED ASDR CALA2023050801403Battery Pack · no testB777-33-3-7019 B2 INT: DR 5 RIGHT (AFT M33409) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 433005 REPLACED DOOR 5 RIGHT EMERGENCY LIGHT BATTERY PACK M33409 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: D7SDR CALA2023050801402Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 5 RIGHT (FWD M33408) EMERGENCY LIGHT BATTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 432865 REPLACED DOOR 5 RIGHT EMERGENCY LIGHT BATTERY PACK M33408 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: SDR CALA2023050801401Battery Pack · no testB777-33-3-7019 B2 INT: DOOR 2 RIGHT FWD (M33097) EMERGENCY LIGHT BTTERY FAILED OPERATIONAL AND BITE TEST. P/N OFF: D717-01-100 S/N OFF: 176485 REPLACED DOOR 2 RIGHT EMERGENCY LIGHT BATTERY PACK M33097 AND INSTALLATION TEST PASSED AS PER AMM 33-51-06. P/N ON: DSDR CALA2023050501362Oxygen Bottle · unserviceableDURING LAVATORY CDS OXYGEN SYSTEM INSPECTION FOUND LAV ''A'' CDS O XYGEN CYLINDER DISCHARGE INDICATOR DAMAGED. TO REPLACE CDS OXYGEN CYLINDER TEST AS PER AMM TASK 35-21-00-710-801. TEST PASSED. P/N ON:4441806-022 S/N ON:41806-022-05983 FOUND THE LANYARD ASSY DSDR CALA2021121702393None · noneON TAKE OFF ROLL ON RWY 9R ORD A/C STATE ON TAXI WAY. ELEC TEST. TEST OK. VERIFIED RUNWAY 9R WAS SELECTABLE PER TOMC REQUEST VERIFIED THE FOLLOWING INFORMATION: CORRECT NAV FOR EGPWC DB SOFTWEAR UPDATE TO 624. EGPWC DATA BASE U772112.001 INSTALLED. GPS COORDISDR CALA2021082001386Slat · damagedPDA 1 6"BY 9" PIECE SECTION MISSING FROM #5 SLAT. FOUND ON ARRIVAL. FOLLOWING GMM 02-30-95SDR CALA2020042600878Stringer · unknownSUPPORT TASK - REF QC REQUEST - REF EA 5310-07558 OP 002 - 777-3 00ER RH UNDERWING LONGERON FITTING MODIFICATION (FOR SCEPTRE INF O UPDATE) REF NR LP 9130441 EA 5310-07558 OP 002 777-300ER RH UNDERWING LONGERON FITTING MOD IFICATION ACCOMPLISHED, STRUCTURAL SISDR CALA2020042600875Stringer · unknownSUPPORT TASK - REF QC REQUEST - REF EA 5310-07558 OP 003 - 77-30 0ER LH UNDERWING LONGERON FITTING MODIFICATION (FOR SCEPTRE INFO UPDATE) REF NR LP 9130442 EA 5310-07558 OP 003 777-300 ER LH UNDERWING LONGERON FITTING MO DIFICATION ACCOMPLISHED, STRUCTURAL SIGSDR CALA2020040300782Battery Pack · failedB777-33-3-7015 NO.4 RH DR M33401 EMER PWR BATTERY PACK CAPACITY CHK FAIL (LESS THAN 5MINS) REFER NR LP 9130097 NO.4 R/H DR M33401 EMER PWR BATTERY PACK REPLACED AND CHECKED FOUND NORMAL AS PER AMM 33-51-06SDR CALA2020040300781Battery · failedB777-33-3-7015 NO.2 DR R/H M33097 EMER PWR BATTERY PACK CAPACITY CHK FAIL (LESS THAN 15MINS) REFER NR LP 9130098 NO.2 DR R/H M33097 EMER PWR BATTERY PACK REPLACED AND CHECK NORMAL IAW AMM 33-51-06SDR CALA2017121604472Oven · smokeFWD GALLEY OVEN 106 SMOKING BADLY. REPLACED THE OVEN.SDR CALA2017112104182Lamp · inoperativeDURING A CHECK, FOUND SEAT 45G EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS AND TESTED GOOD IAW AMM 33-51-00.
Back to N2243U