N2332U
Service difficulty reports · 24
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2332U' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2332U' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026082618935Hook · brokenDOOR FRAME, LOWER HOOK AFT SIDE HOOK IS BROKEN. REF IPC 523-12-01-03 ITM 168. REMOVED AND INSTALLED LOWER HINGE HOOK FOR SLIDE.SDR CALA2025121212079Valve · faultedNR 1 ENGINE IS EXPERIENCING AN INCREASE IN OIL CONSUMPTION. PE RFORM A VISUAL INSPECTION THE SUBJECT ENGINES EDUCTOR VALVE. BE SURE TO CHECK THE AIR LINE THAT RUNS ALONG THE VALVE TO SEE IF THERE ARE ANY INDICATIONS. IAW AMM 79-21-17/401 FOR LOCATION OF THE EDSDR CALA2025120911930Packing · leakingENGINE HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. ACCOMPLISHED A SNIFF CHECK OF OIL FOR FUEL ODOR IN THE OIL SYS, IAW AMM 12-13-01-130-803-002, STEP F.(1). ACCOMPLISH FIM 71-05/805 TO TROUBLESHOOT FOR HOC. PERFORM TEST NR 6. POWER LEAK CHECK WITH ALL DSDR CALA2025071506580Light · brokenSEAT 48G AISLE EMERGENCY LIGHT BROKEN REPLACED LIGHT ASSEMBLY AND OPERATION CHK OK. REPLACED LIGHT ASSEMBLY AND OPERATION CHK NORMAL.SDR CALA2025042804255Battery Pack · dischargedEMERGENCY FLASHLIGHT BATTERY DATE CHECK - VISUAL CHECK (ADDED BY EC0300-01598) PROCEDURE - REPLACE ALL EMERGENCY FLASHLIGHT BATTERIES EXCEPT POSITION 4L, 5L, AND 3L BECAUSE MANUFACTURE EXPIRATION DATE LESS THAN SLM LIMITE. REPLACE THESE EMERGENCY FLASHLIGHT BASDR CALA2025042204127Battery Pack · dischargedDR L3 EMER PWR BATTERY PACK M33302 CAPACITY LOW. DR L3 EMER PWR BATTERY PACK M33302 REPLACED AND CARRIED OUT INSTALLATION TEST WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545065).SDR CALA2025042204126Battery Pack · dischargedDR 1 RH EMER PWR BATTERY PACK M33094 CAPACITY LOW. DR 1 RH EMER PWR BATTERY PACK M33094 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545015).SDR CALA2025042204125Battery Pack · dischargedDR 2 LH EMER PWR BATTERY PACK M33096 CAPACITY LOW. DR 2 LH EMER PWR BATTERY PACK M33096 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544821).SDR CALA2025042204124Battery Pack · dischargedDR 5 OVERHEAD CREW REST EMER PWR BATTERY PACK M33142 CAPACITY LOW. DR 5 OVERHEAD CREW REST EMER PWR BATTERY PACK M33142 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544747).SDR CALA2025042204121Battery Pack · dischargedDR R5 EMER PWR BATTERY PACK M33408 CAPACITY LOW. DR R5 EMER PWR BATTERY PACK M33408 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4545121).SDR CALA2025042204120Battery Pack · dischargedDR R4 EMER PWR BATTERY PACK M33401 CAPACITY LOW. DR R4 EMER PWR BATTERY PACK M33401 REPLACED AND INSTALLATION TEST HAD BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4543695).SDR CALA2025042204119Battery Pack · dischargedDR R4 EMER PWR BATTERY PACK M33404 CAPACITY LOW. DR R4 EMER PWR BATTERY PACK M33404 REPLACED AND INSTALLATION TEST HAS BEEN C/O WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544848).SDR CALA2025042204118Battery Pack · dischargedDR L4 EMER PWR BATTERY PACK M33400 CAPACITY LOW . DR L4 EMER PWR BATTERY PACK M33400 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544899).SDR CALA2025042204116Battery Pack · dischargedDR R3 EMER PWR BATTERY PACK M33304 CAPACITY LOW. DR R3 EMER PWR BATTERY PACK M33304 REPLACED AND CARRIED OUT INSTALLATION TEST WITH NORMAL RESULT AS PER AMM 33-51-06 (REF ELB 4544964)SDR CALA2025022702499Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - FOUND THE DOOR 4L 3EA EMER AREA LT MAIN AISLE NOT WORKING. R/R THE NEW BATTERY PACK AND OPCK NML PER A.M.M 33-51-06-960-802. REPLACED THE BATTERY & OPS CKD OK.SDR CALA2025020402192Light · brokenINSPECTION FOUND THE EMERGENCY LIGHT BROKEN AT SEAT 48G. REPLACED LIGHT ASSY AND CONDITION CHK OK.SDR CALA2025012702067Guard · brokenEMER LIGHTS EICAS ADVISORY FLIGHT DECK EMERGENCY LIGHT SWITCH IS NOT IN THE ARMED POSITION, OR SWITCH IN ARMED POSITION AND FLIGHT ATTENDENT EMERGENCY LIGHT SWITCH SELECTED ON. EMER LTS SWITCH-SWITCH GUARD BROKEN/LOOSE. WONT ENGAGE SWITCH WH EN CLOSD SECURED CSDR CALA2024120601435Sight Glass · crackedDOOR 1L SLIDE PACK PRESSURE GUAGE LENS CRACKED. REPLACED DOOR ASSIST PRESSURE GAUGE VIEW PORT AS REQUIRED.SDR CALA2022110403041Battery · failedB777-33-3-7019 DR R5 EMER LIGHT BATTERY PACK M33409 TEST FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1156371 AND ORIGINATED BY EMP V898181. DR R5 EMER LIGHT BATTERY PACK M33409 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 AND ATTACH FORM 44-0008 ITEM 1 TO 2 ACSDR CALA2022071501768Strainer · broken#2 ENGINE MAIN FUEL PUMP INTERSTAGE STRAINER FOUND BROKEN AND DEFORMED . REFERENCE TASK 73-11-04-200-801-H00. FOUND ABNORMAL DISCREPANCY (BROKEN MAIN FUEL PUMP INTERSTAGE LP#9057853 LOCATION IS # 1 ENGINE DISCREPANCY. FILTER) AT#1 ENGINE. RECOMMEND SDR TO BSDR CALA2019063001095Hose · brokenON ARRIVAL, FOUND NO.1 BRAKE HYD HOSE LINE BROKEN AND HYD LEAK DURING TAXING IN. NR 1 BRAKE HYD HOSE REPLACED AND LEAK CHECK GOOD IAW AMM 20-10-10SDR CALA2018010500068Flashlight · inoperativeFLASHLIGHT AT THE L2 DOOR DISPLAYS A RED LIGHT. REPLACED THE FLASHLIGHT.SDR CALA2017120804371Light · inoperativeDURING A CHECK, FOUND SEAT 42G & 44G EMERGENCY LIGHTS INOPERATIVE. THE EMERGENCY LIGHTS WERE REPLACED IAW AMM 33-51-00.SDR CALA2017032100664Battery · dischargedEMERGENCY FLASHLIGHT AT 4L INOP. REMOVED AND REPLACED 4L EMERGENCY FLASHLIGHT BATTERY WITH SERVICEABLE UNIT. OPERATION IS NORMAL.
Back to N2332U