N24702
Service difficulty reports · 97
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N24702' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N24702' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017081102587Pressure Switch · leakingHYDRAULIC PRESSURE INDICATED ZERO, SYSTEM B LOSS OF HYD B SYSTEM. EMERGENCY DECLARED. B SYSTEM BOTH ELECTRICAL AND EDP SHUTOFF BY CREW WHEN LOW PRESSURE LIGHT FLICKERED ON . RESERVOIR STILL HAD SOME FLUID IN IT, ON ARRIVAL. FOUND PTU PRESSURE SWITCH BUSHSDR CALA2017041400965Post · crackedL1 WINDOW POST CRACKED UPPER OUTBD CORNER. REPAIRED L1 WINDOW IAW EC/RA 5610-01395.SDR CALA2017041400964Window Frame · crackedR1 WINDOW FRAME HAS A TOOLING MARK WITH A CRACK ON INSIDE SURFACE OF THE UPPER O/B RADIUS. REPAIRED R1 WINDOW IAW EC/RA 5610-01394. SEE FLEET CYCLE LP 98 98271 FOR WORK PERFOMED.SDR CALA2017041000946Skin · corrodedAFT CARGO DOOR HAS SPOTS OF CORROSION BY THE DOOR LINER LOWER SNAP CLIPS (AFT AND FWD CLIP BTM.) NON ROUTINE COMPLETED SEE WIP AND TASK'S FOR WORK ACCOMPLISHED. ALL WORK DONE IN ACCORDANCE WITH ECRA 5232-01161.SDR CALA2017041000945Door Frame · crackedFWD BOTTOM OF R1 DOOR CUTOUT STRUCTURE AT ATTACHMENT POINT TO THE R1 DOOR CORD AT STA 294.5 RBL 55 IS CRACKED. NON ROUTINE COMPLETED SEE WIP AND TASK'S FOR ALL WORK ACCOMPLISH ED. ALL WORK DONE IN ACCORDANCE WITH ECRA 5311-01854.SDR CALA2017040700879Skin · damagedFOUND SKIN DAMAGED JUST ABOVE THE FIRST FWD INBD NUT PLATE FOR PANEL 191CR. REPAIRED THE SKIN AT BS 500C, STRINGER 27R IAW EC/RA5330-06028.SDR CALA2017040700873Fitting · brokenBROKEN AFT SPAR HINGE FITTING FOR THE NR 4 FLIGHT SPOILER PANEL. THE FITTING WAS REPLACED IAW DWG 115A5100, AND SRM 51-40-02, PG 4, FIG 12.SDR CALA2017040700872Fitting · brokenBROKEN AFT SPAR FITTING FOR THE NR 5 FLIGHT SPOILER PANEL. THE FITTING WAS REPLACED IAW DWG 115A5100, AND SRM 51-40-02, PG 4, FIG 12.SDR CALA2017032400692Bulkhead · crackedR/H WHEEL WELL VERTICAL PRESSURE WEB BETWEEN RBL 31.83 AND RBL 40 AREA IS CRACKED. R/H WHEEL WELL VERTICAL PRESS WEB HAS BEEN REPAIRED IAW SRM 57-10-10 REP 3 THRESHOLD INSP AT 56000 FLT CYCLES AFTER REPAIR FOLLOWED BY REPEAT INSP AT EACH 36000 FLT CYC''S PERSDR CALA2017031100577Skin · dentedDENT LOCATED AT STA 1058 RIGHT SIDE OF FUSELAGE JUST BELOW THE APU INLET WAS FOUND TO BE OUT OF LIMITS AS PER SRM 53-00-01 FIG 103 DETAIL (G) EXTERNAL REPAIR INSTALLED IN ACCORDANCE WITH SRM 53-00-01 REPAIR 3.SDR CALA2016091900660Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK IN FWD CEILING PANEL IS DEAD. R & R THE BATTERY PACK.SDR CALA2016060600350Bulb · inoperativeR1 EXTERIOR LIGHT INOPERATIVE. R & R THE BULB IAW AMM 33-51-04. OPS CHECKED GOOD IAW AMM 33-51-04-710-0 02.SDR CALA2016060600349Battery Pack · inoperativeL1 OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R BATTERY PACKS AT POS M01672, M01673, M01674 & M01675 IAW AMM 33-51-06. PERFORMED EMERGENCY LIGHTS OPERATIONS CHECK IAW AMM 33-51-00, FOUND NORMAL AMM 33-51-00- 720-003. OPERATIONS TESTED GOOD IAW AMM 33-51-710-SDR CALA2016060600345Skin · not reportedACCOMPLISHED REPAIR TO EXTERNAL POWER FUSELAGE SKIN AFT SIDE OF POWER RECEPTACLE, TWO EACH DAMAGED HOLES IAW ECRA 5330-05715.SDR CALA2015121801001Battery Pack · dischargedEEPL INOPERATIVE AT ROWS 22 - 29 DEF. R & R EEPL BATTERY PACK IAW AMM 33-51-06. OPERATIONS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2015121801003Battery Pack · dischargedEEPL BIN LIGHT IS INOPERATIVE AT 20 ABC. R & R EEPL BATTERY PACK. OPERATIONS CHECKED GOOD IAW AMM 33-51-06. SEE LOG PAGE 5846549 FOR ENTRY FOR BATTERY PACK REPLACEMENT AT STATION 727C+13,WL 212 & LBL 68.SDR CALA2015121300990Battery Pack · dischargedEEPL BIN LIGHT INOPERATIVE AT 11 ABC. R & R EEPL BATTERY PACK. OPERATIONS CHECKED GOOD IAW AMM 33-51-06. SEE LOG PAGE 5846549 FOR ENTRY FOR BATTERY PACK REPLACEMENT AT STATION 727L+13, WL 212 & LBL 68.SDR CALA2015121801002Nut Plate · missingR1 DOOR FWD GIRT BAR FITTING NEEDS TO BE REMOVED TO FOM. RE-INSTALL ON THIS CARD. REMOVED R1 DOOR FWD GIRT BAR FITTING, FOUND NUTPLATE TO BE MISSING UPON INSTALL. REPLACED BONDED NUTPLATE IAW SRM 51-40-10. RE-INSTALLED R1 FWD GIRT BAR FITTING IAW AMM 25-66SDR CALA2014070700883Rod End · damagedDOOR L1 OPENED IN FLIGHT 4 INCHES PRESSURIZATION. DID LOTS OF ABNORMAL THINGS TURN ON PACKS ON HIGH, HELPED PART-TIME. ALSO HEARD 2 LOUD THUMPS BELOW CAPTAINS FEET. 1L NOT CLOSING PROPERLY DUE TO VERY DETERIORATED & DAMAGED GUIDE ARM ROD END. R & R GUIDE ASDR CALA2013040500202Switch · inoperativeRT FUEL BYPASS LIGHT ON. R & R FUEL FILTER ELEMENT AND INSTALLED NEW SWITCH FOR FILTER ELEMENT. TESTED IAW 73-1102-900-801-F00.SDR Z6WR20120319005Ring · wornREF: CMM 78-31-37, 01MAR2012, REV 023. INSPECTION FINDING OF (2) MISSING BACB30LE6K29 BOLTS (FIGURE 12, ITEM 100) NOTES THE FOLLOWING RELATED DISCREPANCIES. A) FIGURE 12, ITEM 115 AREA OF MATERIAL WEAR MEASURING .32 X .08 X .018 DEEP ON THE 315A2222-5 CASCADSDR CALA2012031400177Skin · damagedLIGHTNING STRIKE STA 1016 BETWEEN STR 7L AND 8L. REPAIRED PER ECRA 5310-05470, PARTIAL WORK ACCOMPLISHED BACK FORM 44.0008 ATTACHED. ISSUE A DIP TO ACCOMPLISH A PERMANENT REPAIR PRIOR TO MARCH 7 2014 PLANNING TO CONTACT ENGINEERING AFTER JANUARY 7 2014 BUT BESDR CALA2012030500155Frame · crackedRIGHT FRAME BRACKET AT STA 500A R CRACKED INTO RADIUS. REPAIRED FRAME IN ACCORDANCE WITH EC/RA 5310-05468.SDR CALA2012022800137Bracket · crackedSUPPORT TASK LEFT FRAME BRACKET AT STA 400L CRACKED INTO RADIUS. INSTALLED FRAME REPAIR REF EA-5310-04716 REV C AT STA 400L BETWEEN STR 8 AND 9 LEFT.SDR CALA2012022800138Bracket · crackedSUPPORT TASK RIGHT FRAME BRACKET AT STA 440R CRACKED INTO RADIUS. REPAIRED FRAME IAW EA 5310-04716 REV C.SDR CALA2012022800134Threshold · corrodedR-2 DOOR CHORD THRESHOLD CHORD IS CORRODED. INSTALLED NEW R2 CHORD IAW SRM 51-40-02.SDR CALA2012022800136Intercostal · crackedSUPPORT TASK FWD CABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 277 TO 294.5 AT BL 0. REMOVED AND REPLACED FWD CABIN FLOOR STRUCTURE INTERCOSTAL STA 277 TO STA 294.5 IAW SRM 51-40-02.SDR CALA2012022800135Bracket · crackedSUPPORT TASK LEFT FRAME BRACKET AT STA 480L CRACKED. REPAIRED LEFT FRAME BRACKET PER EA5310-04716.SDR CALA2012022800133Bracket · crackedSUPPORT TASK - LEFT FRAME BRACKET AT STA 500C CRACKED. REPAIRED LEFT FRAME BRACKET STA 500C STR 8L-STR 9L PER ECRA 531 0-04716.SDR CALA2012022800132Bracket · crackedRIGHT FRAME BRACKET AT STA 480R CRACKED INTO RADIUS. REPAIR RIGHT FRAME BRACKET AT STA 480R IAW EA5310-04716 REV C.SDR CALA2012022800131Bracket · crackedSUPPORT TASK - LEFT FRAME BRACKET AT STA 727D L CRACKED. REPAIR LEFT FRAME BRACKET AT STA 727 D LT IAW EA 5310-04716 REV C.SDR CALA2012022800130Bracket · crackedSUPPORT TASK - LEFT FRAME BRACKET AT STA 500A CRACKED. REPAIRED LEFT FRAME AT 500A IAW EA# 5310-04716.SDR CALA2012022800129Bracket · crackedSUPPORT TASK RIGHT FRAME BRACKET AT STA 747R CRACKED. REPAIR PER EA5310-04716 REV C . SEE FORM 44.0008 ATTACHED FOR PARTIAL WORK ACCOMPLISH .SDR CALA2012022800128Bracket · crackedSUPPORT TASK RIGHT FRAME BRACKET AT STA 787R CRACKED. REPAIR FRAME AT STA 787R PER EA 5310-04716 REV C.SDR CALA2012022400122Bracket · corrodedSUPPORT TASK, RIGHT FRAME BRACKET AT STA 867 R CRACKED. REPAIRED PER EA 5310-04716 REV C.SDR CALA2011102000677Connector · looseNR 2 ENGINE A LOOP INOPERATIVE AFTER TAKEOFF, RECIEVED A FAULT LIGHT, INTERMITTENT CONTACT. MX RESET CIRCUT BREAKER IAW INSTRUCTION, FAULT LIGHT WENT OUT. CONTINUED ON TO DESTINATION. 2 HRS LATER FAULT LIGHT ILLUMINATED AGAIN, LANDED IAW QRH. FOUND CONNECSDR CALA2011051600368Cable Assy · disconnectedLANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF LANDING WEIGHT 148.0 SMOOTH LANDING REF FIM 32-30-00-810-813. FOUND GSBV INTERLOCK ACTUATING CABLE DISCONNECTED. RECONNECTED REF AMM 27-12-00-820-803 FIM REPAIR CONFIRMATION GOOD.SDR CALA2011013100049Unknown · smokeON TAKEOFF ROLL AT ABOUT 110 KNOTS, CABIN AND COCKPIT BEGAN TO FILL WITH SMOKE, AS WE PITCHED UP SMOKE INCREASED DRAMATICALLY FILLED THE COCKPIT FROM CEILING DOWN TO THE POINT WHERE F/O HEAD WAS NOT VISIBLE AND BREATHING IMPAIRED. SMOKE WAS COMING OUT OF EXHASDR CALA2010061700282Skin · damagedSUPPORT TASK: REFERENCE LOG PG 8135297 RE-INSPECTED DAMAGE LOCATED AT 3 INCHES FROM FWD EDGE AND 20.25 INCHES FROM BOTTOM OF DOOR TO BE OUT OF LIMITS IAW SRM 52-30-01 ALLOWABLE DAMAGE 1. REPAIRED AFT CARGO DOOR LOWER FWD SKIN REF ECRA 5230-01840.SDR CALA2009082600503Light · inoperativeRIGHT WING EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED RIGHT WING EXTERIOR EMERGENCY LIGHT, OPS CHECKS GOOD.SDR CALA2009040300177Charger · inoperativeDURING SERVICE CHECK FOUND EMERGENCY AISLE LIGHTING INOPERATIVE AT SEAT ROWS 15 - 21 LEFT, R-1, R-2, R-3 LEFT AND AT FORWARD GALLEY. REPLACED BATTERY PACKS AND CHARGERS AT FORWARD GALLEY OVERHEAD AND LEFT MID-CABIN POSITIONS PER AMM 33-51-06-960-805 AND AMM 3SDR CALA0800965Battery Pack · dischargedSEVERAL ROWS OF EMERGENCY EXIT LIGHTS ARE INOPERATIVE. ISOLATED TO AFT GALLEY OVERHEAD BATTERY PACK. REMOVED AND REPLACED AFT GALLEY OVERHEAD BATTERY PACK, ALL EMERGENCY LIGHTS CHECK NORMAL.SDR CALA0700694Skin · corrodedLOWER FUSELAGE STA 500 CORRODED AT VERIZON ANT FOOTPRINT. REPAIRED PER SRM 53-00-01 REPAIR 3.SDR CALA0700693Door Frame · corrodedINSPECTION FOUND L-1 DOOR CHORD CORRODED AT STA 291.5-360, LBL 43. THE CHORD WAS REMOVED AND REPLACED IAW SRM 51-40-02 AND GMM 10-900-02.SDR CALA0500312Threshold · corrodedINSPECTION FOUND L-2 DOOR LOWER THRESHOLD FRAME CORRODED AT STA 937-996, LBL 52 TO RBL 52. THE L-2 DOOR THRESHOLD WAS REMOVED AND REPLACED IAW SRM 51-40-02.SDR CALA0500310Floorbeam · corrodedINSPECTION FOUND FORWARD FLANGE OF FLOORBEAM CORRODED ON NUT PLATE HOLES AT STA 986.6, LBL 23, LBL 26, RBL 4, RBL 12, AND RBL 20. THE FLOORBEAM WAS REPAIRED IAW ECRA 5321-01292.SDR CALA0500309Floorbeam · corrodedINSPECTION FOUND LITE CORROSION UNDER SCREW HOLES ON FLOORBEAM AT STA 967, LBL 30 TO RBL 30. REPAIRED FLOORBEAM IAW ECRA 5321-01291.
Back to N24702