N2534U
Service difficulty reports · 36
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2534U' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2534U' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025112811560Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK 1 (M33118) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33118) IAW AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025112811558Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK 2 (M33145) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33145) IAW AMM 33-51-00,FOUND WORKING SATISFACTORY.SDR CALA2025112811556Battery · no testOFCR EMERGENCY POWER SUPPLY BATTERY PACK RH (M33142) FAIL TEST. BATTERY PACK REPLACED. INSTALLATION TEST CARRIED OUT FOR BATTERY PACK (M33142) AS PER AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025112811552Battery · inoperativeDOOR 4L EMERGENCY POWER SUPPLY BATTERY FAILED TEST. BATTERY REPLACED IAW AMM 33-51-00. INSTALLATION TEST CARRIED OUT FO DOOR 4L EMERGENCY POWER SUPPLY BATTERY (M33406) AS PER AMM33-51-00, FOUND WORKING SATISFACTORY.SDR CALA2025102010254Oven · smokeOVEN SMOKING OR SPARKING G9B GALLEY HALF CARRIER BOX 938R OVEN 606 SMOKING WHEN ON. OVEN 606 HAS STRONG SMELL OF BURNED FOOD. OVEN NEEDS DEEP CLEAN OR REPLACEMENT. DEFERRED OVEN 606 AS PER NEF 2520AV. M PROC C/W. REMOVED AND REPLACED 606 OVEN PER AMM 25-32-SDR CALA2025100209558Slide · no discrepancyOFF-WING ESCAPE SLIDE PACK - INSTALLATION OFF-WING ESCAPE SLIDE PACK INSTALLATION, LT OVERWING SLIDE ETASK CARD BLOCK 8 TO BLOCK 12 ARE RII ITEMS. INSPECTION BUYBACK REQUIRED. UPGRADED TO RII. ALL STEPS ACP'D. INSPECTION WITNESSED INSTALLATION ON LH OVERWING SDR CALA2025092309162Bracket · damagedFWD CARGO DOOR SENSOR (S52001) BRACKET DAMAGED. INSTALLED BRACKET FOR PROXIMITY SWITCH WITHIN LIMITS IAW AMM 52-34-20-201 PERFORMED INDICATION PROXIMITY SENSOR TEST 52-71-02-730-801 OK FOR SERVICE. INSTALLED STRIKER PLATE TARGET FROM AIRCRAFT 2139 PER IPC 5SDR CALA2025091809023Light · inoperativeFOUND 43D, 48G EMERGENCY LIGHT ARE INOP. REPLACED NEW EMERGENCY LIGHT ASSEMBLY IN SEAT, CHK FUNCTION NORMALSDR CALA2025071606622Seal · faultedNR 1 ENGINE HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. ACCOMPLISH A SNIFF CHECK OF OIL FOR FUEL ODOR, IAW AMM 12-13-01-130-803-002, STEP F.(1). ACCOMPLISH FIM 71-05 TASK 805, STEPS D.(1) TO D.(4) TO TROUBLESHOOT FOR HOC. PERFORMED TEST NR 6, PART POWER SDR CALA2025050704526Safety Wire · incorrectRIGHT NLG WHEEL RIM TIE BOLTS SAFETY WIRED INCORRECTLY. TIRE SHOP SAFETIED FUSE PLUGS INCORRECTLY. SEE PICTURES. UPDATED PICS REPLACED SAFETY WIRE ON RIGHT NLG RIM TIE BOLTS . REF AMM SUBTASK 32-45-03-210-001. AS REQUSTED BY THE FAA, SUBMITTING SDR FOR FINDINGSDR CALA2025031402811Engine · oil consumptionE2 ESN 901206 HAS EXPERIENCED AN INCREASE IN OIL CONSUMPTION. A CCOMPLISH A SNIFF CHECK OF THE OIL FOR FUEL SMELL IN THE OIL SYS TEM, REF. AMM 12-13-01-130-803-002 STEP F.(1). ACCOMPLISH FIM 71 -05 TASK 805 STEPS D.(1) TO D.(4) TO TROUBLESHOOT FOR HOC. ALSO PSDR CALA2024120601426Lamp · inoperativeDURING CHECK FOUND LT HAND DOME LIGHT EMERGENCY BULP NOT ILLUMINATING L/H FLT DECK DOME LIGHT EMERGENCY BULB REPLACED AND TESTED SATIS IAW AMM 33-51-07 REV 102.USED ONE P/N: 1317 FROM SPAREBOX.SDR CALA2024102402725Battery · failedDR 3R OVER WING ESCAPE SYSTEM BACKUP BATTERY PACK DURING OP TEST TRANSFER REFER NON-ROUTINE WO.3933141 AND ORIGINATOR V920580 CORRECTION: DR 3R OVER WING ESCAPE SYSTEM BACKUP BATTERY PACK DURING OPC TEST RED LIGHT NOT COME ON DR 3R OVER WING ESCAPE SYSTEM BACKSDR CALA2024102302723Battery · no testCABIN: SEAT 36-43 AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33401 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302722Battery · no testCABIN: R/H DOOR 4 AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33404 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302721Battery · no testCABIN: R/H MOST AFT ZONE AREA EMERG LT CAPACITY TEST FAIL. EMERG LT PWR PACK M33409 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302720Battery · no testCABIN: R/H DOOR 5 AREA EMERG LT CAPACITY TEST FAIL. EMERG LT PWR PACK M33408 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302719Battery · no testCABIN: DOOR 1 AREA EMERG LT CAPACITY TEST FAIL. EMER PWR PACK M33093 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302718Battery · no testCABIN: FWD ZONE L/H EMERG LT CAPACITY TEST FAIL. EMER PWR PACK M33424 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302717Battery · no testCABIN: R/H DOOR 2 AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33097 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302716Battery · no testCABIN: R/H SEAT 9-22 CEILING EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33304 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302715Battery · no testCABIN: L3 DOOR AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33301 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302714Battery · no testCABIN: SEAT 30-43 CEILING EMERG LT CAPACITY TEST FAILED. EMER LT PWR PACK M33303 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302707Battery · no testCABIN: SEAT 9-16 FLOOR PROX LT CAPACITY TEST FAIL EMERG LT PWR PACK M33096 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302706Battery · no testCABIN: DOOR 2 AREA & FWD ZONE R/H EMERG LT CAPACITY TEST FAIL. EMERG LT PWR PACK M33094 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2023110303280Fuse · inoperativeROWS 46DEFG THROUGH 51DEFG FLOOR PROXIMITY EMERGENCY LIGHTS INOP REQUEST TO PLACE AFFECTED PROXIMITY LIGHT(S) ON DEFERRAL MEL 3351A MAINT IS TRYING TO CLEAR THIS ITEM. REPLACED FUSE, OPS CHECK NORMAL AT THIS TIME REF AMM 33-51-06 & WDM 33-51-11SDR CALA2023030100589Battery · failedB777-33-3-7019 DR R2 EMER LIGHT BATTERY M33098 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462757 AND ORIGINATOR V898181. DR R2 EMER LIGHT BATTERY M33098 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK SDR CALA2023030100587Battery · failedB777-33-3-7019 DR L2 EMER BATTERY M33096 CAPACITY CHECK FAIL. TRANSFER REFER NON-ROUTINE WO.1462768 AND ORIGINATOR V898181. DR L2 EMER LIGHT BATTERY M33096 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPSDR CALA2023030100586Battery · failedB777-33-3-7019 AFT CREW REST L/H EMER LIGHT BATTERY M33143 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462794 AND ORIGINATOR V898181. AFT CREW REST EMER LIGHT BATTERY M33143 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPSDR CALA2023030100584Battery · failedB777-33-3-7019 DR L4 EMER LIGHT BATTERY M33405 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462800 AND ORIGINATOR V934240. DR L4 EMER LIGHT BATTERY M33405 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED. WORK ACCOMPLSDR CALA2023030100583Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33305 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462812 AND ORIGINATOR V898181. DR R3 EMER LIGHT BATTERY M33305 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V89695SDR CALA2023030100582Charger · failedB777-33-3-7019 DR R4 EMER LT CHARGER M33401 TEST FAIL. TRANSFER REFER NON-ROUTINE WO.1462818 AND ORIGINATOR V898181 DR R4 EMER LT BATTERY CHARGER M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V898181 AND INSPECTED BY V896958 SDR CALA2023030100581Battery · failedB777-33-3-7019 DR R4 EMER LIGHT BATTERY M33401 CAPACITY LOW. TRANSFER REFER NON-ROUTINE WO.1462826 AND ORIGINATOR V898181. DR R4 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06 ATTACH FORM 44-0008 ITEM 1 TO 2 ACCOMPLISHED WORK ACCOMPLISDR CALA2022112503211None · noneCREW HEARD A LOUD BANG ON CLIMBOUT THROUGH 8000 FT NOISE NOTICED FWD OF DOOR 1LEFT . DISCOVERED BIRD STRIKE BELOW AND AFT OF L3 COCKPIT WINDOW. PERFORMED BIRD STRIKE INSP PER AMM 05-15-18-210-801. NO DAMAGE OR EVIDENCE OF ADDITIONAL BIRD STRIKES FOUND ON AIRCRSDR CALA2019110501916Battery Pack · dischargedLH DOOR 2 ONE ZONE OF EMERGENCY LIGHT INOP CHK FOUND BATTERY PACK INOP, HOWEVER NIL STOCK IN HKGSDR CALA2017112004165Light · missingDURING A CHECK, PAX SEAT 20D EMERGENCY LIGHT ASSY AND MOUNTING SHROUD MISSING. REPLACED THE MISSING SHROUD AND LIGHT ASSY. OPS CHECKED OK.
Back to N2534U