N262UP
Service difficulty reports · 82
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N262UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N262UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2020100961119Support Fitting · corrodedINSPECTION TYPE: 3C MAIN CABIN FLOOR AT STA 1481 RT OF CENTERLINE IS CORRODED. REMOVED, FABRICATED, AND REPLACED SUPPORT FITTING, IAW DWG AEA0364 AN SRM 51-33-01.SDR IPXA2020072458180Skin · chafedINSPECTION TYPE:3C#3 ENG PYLON FWD APRON I/B SIDE IS CHAFED THROUGH SUPPORT BEAM AND APRON SKIN.REPAIRED APRON SKIN AND SUPPORT BEAM ON #3 PYLON FWD APRON I/B SIDE BETWEEN YWN=144.300 AND YWN=155 AND BETWEEN XWN=8.000 AND XWN=9.350 IAW EA 011-5410-01-A8374 REVSDR IPXA2020072057978Structure · corrodedINSPECTION TYPE:3C, CENTER TO AFT CARGO FLOOR BULKHEAD UPPER STRUCTURE WAS CORRODED AROUND FASTENER HOLES, ENTIRE LENGTH FROM LT TO RT AT BS 1841. REMOVED THE BULKHEAD CHORD, FABRICATED AND INSTALLED IN MID TO AFT CARGO IAW DWG AGA7170.SDR IPXA2020071357727Floorbeam · corrodedINSPECTION TYPE:3CBULK CARGO COMP UPPER FLOOR BEAM HAS CORROSION BELOW FASTENER HOLES AT STA Y = 1902 X = -15.REPAIRED CORRODED FLOOR BEAM IN BULK CARGO AT STA Y = 1902 X = -15 IAW EA 011-5310-01-A8364 AND EO MD11-5310-77127-A. (MAJOR)SDR IPXA2020071357729Cargo Track · corrodedINSPECTION TYPE:3CBULK CARGO COMP SEAT TRACK FASTENER HOLES HAVE CORROSION FROM STA 1821 TO 1964.X -20REMOVED CORRODED SEAT TRACK FABRICATED AND INSTALLED IN BULK CARGO FROM STA 1821 TO 1967 X= -20 IAW DWG AGA3855, AGA6724 AND EA 011-5310-01-A8368 , EO MD11-53SDR IPXA2020070857528Doubler · chafedINSPECTION TYPE:3C TAIL CONE INTERNAL PRODUCTION DOUBLER AT STA 2163 AND BETWEEN Z= 40 TO Z= 60 HAS CHAFE DAMAGE. REPAIRED DAMAGED TAIL CONE PRODUCTION DOUBLER IAW EA 011-5350-01-A8337 REV I/R AND EO MD11-5330-77105-A. (MINOR)SDR IPXA2020070357262Seat Track · corrodedINSPECTION TYPE:3C AFT CARGO LEFT SEAT TRACK BETWEEN STA 1887 TO STA 1941 X=20 HAS CORROSION AROUND SEVERAL FASTENER HOLES. REMOVED CORRODED SEAT TRACK, FABRICATED AND INSTALLED IN AFT CARGO BETWEEN STA 1887-1941 X=20 IAW DWG AGA3855 AND SRM 51-31-01. (MINORSDR IPXA2020070357257Angle · puncturedINSPECTION TYPE:3C EXTENDED TAILCONE HAS PUNCTURED THROUGH THE RT Z-FRAME. REPAIRED EXTENDED TAILCONE RT Z-FRAME IAW EA 011-5300-1-A8334 REV IR AND EO MD11-5350-77041-A. (MINOR)SDR IPXA2020070157198Support · crackedINSPECTION TYPE:3C CENTER CARGO COMPARTMENT FLOORBEAM SUPPORT RIGHT SIDE AT STA 5-32 BL-16R CRACKED. REMOVED CRACKED FLOOR BEAM SUPPORT, FABRICATED AND INSTALLED IN CENTER CARGO RT SIDE AT STA 5-32 BL-16R IAW SRM 51-35-01.SDR IPXA2020070357256Longeron Splice · crackedINSPECTION TYPE:3C CENTER CARGO COMP LONGERON 33R SPLICE CRACKED INSIDE CHANNEL AT STA 5-123. REMOVED CRACKED SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO LONGERON 33R AT STA 5-123 IAW SRM 51-33-01. (MINOR)SDR IPXA2020070357255Longeron Splice · crackedINSPECTION TYPE:3C CENTER CARGO COMP LONGERON 28R SPLICE CRACKED INSIDE CHANNEL AT STA 5-123. REMOVED CRACKED SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO ON LONGERON 28R AT STA 5-123 IAW SRM 51-33-01. (MINOR)SDR IPXA2020070257254Longeron Splice · crackedINSPECTION TYPE:3C CENTER CARGO COMP LONGERON 41L SPLICE CRACKED INSIDE CHANNEL AT STA 5-123. REMOVED CRACKED SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO ON LONGERON 41L AT STA 5-123 IAW SRM 51-33-01. (MINOR)SDR IPXA2020070257252Longeron Splice · crackedINSPECTION TYPE:3C CENTER CARGO COMP LONGERON 40R SPLICE CRACKED AT CHANNEL STA 5-123. REMOVED CRACKED SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO LONGERON 40R AT STA 5-123 IAW DRAWING N5A6774. (MINOR)SDR IPXA2020070357251Longeron Splice · crackedINSPECTION TYPE:3C CENTER CARGO COMP LONGERON 43L SPLICE CRACKED INSIDE CHANNEL AT STA 5-123. REMOVED CRACKED SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO LONGERON 43L AT STA 5-123 IAW SRM 51-33-01. (MINOR)SDR IPXA2020070157200Support Strut · brokenINSPECTION TYPE:3C CENTER CARGO COMPARTMENT FLOORBEAM TO FRAME SUPPORT STRUT BROKEN IN HALF AT STA 5-32 LBL-17. REMOVED BROKEN FRAME SUPPORT STRUT, FABRICATED AND INSTALLED IN CENTER CARGO AT STA 5-32 LBL-17 IAW SRM 51-35-01. (MINOR)SDR IPXA2020063057199Floor Support · corrodedINSPECTION TYPE:3C MAIN CARGO FLOOR CENTER LINE AT STA 1381 FLOOR SUPPORT HAS CORROSION. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED IN MAIN CARGO AT STA 1381 X=0 IAW SRM 51-35-01.SDR IPXA2020062957115Longeron Splice · crackedINSPECTION TYPE:3C, CENTER CARGO COMPARTMENT LONGERON 35R SLPICE CRACKED INSIDE RADUIS AT STA 5-123.REMOVED CRACKED LONGERON SPLICE, FABRICATED AND INSTALLED IN CENTER CARGO AT LONGERON 35R STA 5-123 IAW SRM 51-33-01. (MINOR)SDR IPXA2020072097943Seat Track · crackedINSPECTION TYPE:3C, MAIN CARGO TRACK CRACKED AT STA 839 X= -75.50. REPAIRED THE CRACKED CARGO TRACK IAW SRM 53-00-52, REPAIR 1, FIG 201, REV.66. MAJOR.SDR IPXA2020072097941Floor Support · crackedINSPECTION TYPE:3C, MAIN CARGO FLOOR SUPPORT AT BS 775 RBL-80 IS CRACKED. REMOVED CRACKED FLOOR SUPPORT, FABRICATED AND INSTALLED IN MAIN CARGO IAW DWG ACA3763.SDR IPXA2020072097946Tee Fitting · chafedINSPECTION TYPE:3C, RIGHT WING FIXED L/E LWR T CHORD AND UPPER ANGLE ARE CHAFED FROM THE TELESCOPIC DUCT PANEL ON I/B SIDE.REMOVED CHAFED T-CHORD, FABRICATED AND INSTALLED ON RH WING FIXED L/E XOS-464 IAW DWG ARB2926.SDR IPXA2020072097945Cap · chafedINSPECTION TYPE:3C, RT WING FIXED L/E LOWER T-CHORD AND UPPER ANGLE CHAFED FROM TELESCOPIC DUCT PANEL ON I/B SIDE.REMOVED CHAFED T-CAP, FABRICATED AND INSTALLED ON RH WING FIXED L/E XOS=464 IAW DWG 1284.SDR IPXA2020072097944Splice Angle · chafedINSPECTION TYPE:3C, RT WING FIXED L/E LWR T CHORD AND UPPER ANGLE CHAFED FROM THE TELESCOPIC DUCT PANEL ON I/B SIDE. REMOVED CHAFED SPLICE ANGLE, FABRICATED AND INSTALLED ON THE RT WING FIXED L/E XOS=464 IAW DWG 1284.SDR IPXA2020070757466Support Angle · crackedINSPECTION TYPE:3C, RH WING L/E PANEL SUPPORT ANGLE ATTACHED TO RIB AT XORS 995 IS CRACKED.REMOVED CRACKED ANGLE, FABRICATED AND INSTALLED ON RH WING L/E RIB AT STA XORS 995 IAW DWG ARB2920. (MINOR)SDR IPXA2020062957118Rib · crackedINSPECTION TYPE:3CRH WING FIXED L/E RIB IS CRACKED ON T/E AT STA XORS 471.REMOVED CRACKED RIB, FABRICATED AND INSTALLED ON RH WING FIXED L/E AT STA XORS 471 IAW SRM 51-35-01. (MINOR)SDR IPXA2020062256762Doubler · crackedINSPECTION TYPE:3C RT WING FIXED L/E BEADED DOUBLER IS CRACKED AT STA XOS 659. REPAIRED CRACKED RT WING FIXED L/E BEADED DOUBLER AT STA XOS 659 IAW SRM 57-40-02 REPAIR 15 FIG 205. (MAJOR)SDR IPXA2020061456571Support Angle · crackedINSPECTION TYPE:3C WTB SUPPORT ANGLE IS CRACKED AT THE TOP, IN THE RADUIS AT STA 1581 BETWEEN L30L AND L31L. FABRICATED AND REPLACED CRACKED ANGLE AT STA 1581 BETWEEN STA L30L AND L31L IAW SRM 51-33-01 AND SRM 51-35-01. (MINOR)SDR IPXA202008058653Seat Track · corrodedINSPECTION TYPE:C3, MAIN CABIN FLOOR, BS 1130 TO 1530, X-107 SEAT TRACK HAD CORROSION IN SEVERAL AREAS. REMOVED AND REPLACED THE SEAT TRACK BETWEEN BS 1276 AND 1410 IAW SRM 53-00-52, REPAIR 1, FIG 201, AND ACA7414. MAJOR REPAIR.SDR IPXA2020062436898Web · crackedINSPECTION TYPE:3C, UPPER CARGO COMPARTMENT L-3 DOOR FWD JAMB TORQUE BOX WEB IS CRACKED BETWEEN STA 1250 - 1256REPAIRED CRACKED L3 DOOR FWD JAMB TORQUE BOX WEB BETWEEN STA 1250-1256 IAW SRM 53-40-15 REPAIR 3 FIG 201 REV 66. (MAJOR)SDR IPXA2020062256860Torque Box · crackedINSPECTION TYPE:3C UPPER CARGO COMPARTMENTL3 DOOR AFT JAMB TORQUE BOX HAS 2EA CRACKES AROUND WEB LIGHTNING HOLE. REPAIRED CRACKED L3 DOOR AFT JAMB TORQUE BOX WEB AROUND LIGHTNING HOLE BETWEEN STA 1305.25 AND 1315.42 IAW SRM 53-40-15 REPAIR 3 FIG 201 REV 66. (SDR IPXA2020062256857Support Angle · crackedINSPECTION TYPE:3C UPPER LT WTB RIB SUPPORT ANGLE AT STA 1361 BELOW L30L IS CRACKED. REMOVED CRACKED ANGLE, FABRICATED AND INSTALLED UPPER LT WTB RIB SUPPORT ANGLE AT STA 1361 BELOW L30L IAW SRM 51-35-01 AND DRWG AEA0553. (MINOR)SDR IPXA2020062256822Door Frame · crackedINSPECTION TYPE:3C MAIN CABIN FLOOR R3 DOOR SURROUND FWD LOWER LIGHTNING HOLE HAS A CRACK. REPAIRED CRACKED R3 DOOR JAMB SKIN BETWEEN STA 1250-1256 IAW SRM 53-40-15 REPAIR 3 FIG 201. (MAJOR)SDR IPXA2020061556531Stiffener · crackedINSPECTION TYPE:3C 3RD VERTICAL STIFFENER FROM FRONT IN RT MLG WW O/B AFT CUTOUT IS CRACKED. REPLACED CRACKED STIFFENER 3RD FROM FRONT IN RT MLG WW O/B AFT CUTOUT IAW SRM 51-35-01. (MINOR)
Back to N262UP