- Registered owner
- Delux Public Charter LLC
- Location
- Dallas, TX
- Owner type
- LLC
- Serial number
- 145726
- Year built
- 2003
- Type
- Fixed wing multi engine
- Engine
- Turbo-fan
- Airworthiness
- Standard, transport
- Airworthiness date
- August 4, 2021
- Certificate issued
- October 24, 2019
- Expires
- October 31, 2029
- Mode S code
- A29625
Embraer EMB-135LRTCDS T00011ATAirframe · Embraer EMB-135LRTCDS TE6CHEngine · Rolls-Royce AE-3007A1/3
From the FAA registry file of October 24, 2026.
On this page
Airworthiness directives that may apply · 89
Matched by this aircraft’s airframe and engine models. Each AD’s applicability may narrow it by serial number, part number or equipment.
| 1998 | 1 |
|---|---|
| 1999 | 2 |
| 2000 | 10 |
| 2001 | 9 |
| 2002 | 6 |
| 2003 | 5 |
| 2004 | 12 |
| 2005 | 16 |
| 2006 | 9 |
| 2007 | 4 |
| 2008 | 8 |
| 2009 | 2 |
| 2010 | 8 |
| 2011 | 3 |
| 2012 | 1 |
| 2013 | 1 |
| 2014 | 1 |
| 2015 | 2 |
| 2017 | 3 |
| 2018 | 1 |
| 2019 | 1 |
| 2020 | 1 |
| 2021 | 2 |
| 2023 | 1 |
| 2025 | 1 |
| 2026 | 1 |
Airframe · Embraer EMB-135LR
AD 2026-13-02NavigationAD 2024-26-07FuselageAD 2023-10-02Indicating/Recording System, NavigationInformation bulletins that may apply · 8
Advisory, not mandatory.
Airframe · Embraer EMB-135LR
SAIB AIR-21-15R1Navigation SystemSAIB AIR-20-17Air Conditioning - Cabin Pressure Control SystemSAIB NM-19-17Ice and Rain Protection: Electrical Wiring Terminations at Pitot and TAT RelaysSAIB NM-10-13Navigation: Flight Management SystemSAIB NM-09-03Engine Fuel and Control - Implementing Fuel Tank System Airworthiness LimitationsSAIB NM-08-15Instruments: Contamination of the Attitude Heading Reference System (AHRS) ComputersSAIB NM-07-40Embraer EMB-135/145 Landing Gear IncidentSAIB NM-07-20Flight Data RecordersHistorical bulletins · 1
NTSB investigations
No NTSB investigations matched to N266JXMatched by N-number and event date, checked against the reported serial number, make and model. Investigations from before this aircraft carried the mark are under Earlier aircraft. Investigations on Embraer EMB-135LR aircraft
FAA incident reports
No FAA accident or incident reports matched to N266JXMatched by N-number and event date, checked against the reported make and model. Reports from before this aircraft carried the mark are under Earlier aircraft. Reports on Embraer EMB-135LR aircraft
Service difficulty reports · 3
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 4DPA202404290001Monitor · faultedCREW REPORTED- NO PRESSURIZATION INDICATIONS DURING CLIMB OUT. CORR ACTION- MX RESET CPAM AND PRESSURIZATION INDICATIONS WERE PRESENT AND DID NOT DASH OUT.SDR 4DPA2022081105001Switch · out of adjustISSUE- CREW REPORTED BAGGAGE DOOR OPEN MESSAGE APPEARED ON EICAS CLIMBING THROUGH 17000 FEET. LEVELED OFF AT 18000 FEET AND RAN QRH, COMPLIED WITH ALL CHECKLISTS AND DECIDED TO RETURN TO LAS. NO ISSUES WITH PRESSURIZATION HOWEVER AIR RETURNED AS PRECAUTION. COSDR 4DPA2022060400001Dau · failedON DESCENT BELOW 14,000’ CREW HEARD LOUD CLACKING & THUDDING UNDERNEATH COCKPIT, LOUD ENOUGH THAT WE THOUGHT THE LANDING GEAR DOORS WERE OPENING & CLOSING. IMMEDIATELY AFTER, EICAS FILLED WITH WARNINGS & CAUTIONS. SEVERAL FLT INSTRUMENTS FAILED, TURNED OFF &
STCs that may be installed · 72
Approved for this aircraft’s airframe or engine model. The registry doesn’t record which STCs an aircraft has; its records do.
Airframe · Embraer EMB-135LR
STC ST00885LAInstallation of fire extinguisher cartridges as replacements for Pacific Scientific fire extinguisher cartridges in fire extinguisher bottles.STC ST02176AT-DInstallation of a Teledyne Mini Flight Data Acquistion UnitSTC ST02216AT-DInstallation of Teledyne Mini Flight Data Acquisition Unit in a Provisioned EMB-135/145.