N273UP
Service difficulty reports · 305
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N273UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N273UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA11M66108Skin · dentedCREASE IN FUSELAGE 18" BELOW OAT SENSOR ON RT SIDE OF ACFT. REPAIRED REF EO MD11-5330-42284-A.SDR IPXA1M64998Actuator · deactivatedAILERON DEFLECT DISAGREE ALERT ON TAKEOFF CLIMB. FOUND LT OTBD AILERON IS OUT OF LIMITS AT NEUTRAL POSITION. ADJUSTED LT OTBD DEFLECT ACTUATOR IAW AMM 27-16-02-4. CHECKS OK. PRECAUTIONARILY DEACTIVATE T/O DEFLECTED AILERON SYS IAW MEL. R & R INBD AILERON DSDR IPXA10M63948Power Supply · inoperativeINSPECTION TYPE: ASE, DURING EMERGENCY LIGHT TEST EAD SHOWS "EMER LT BAT 1 LO". REPLACED EMERGENCY LIGHT POWER SUPPLY IAW AMM 33-51-01-4. OPS CK GOOD.SDR IPXA10M63942Light · no testEMERGENCY LIGHT FAIL TEST LO 1. R & R WITH NEW MSC & EMERGENCY LIGHT TEST PASSED. ALSO, MSC RTS PASSED IN THE CFDS. REMOVED PLACARD IAW FIM 33-51-00-1 & AMM 31-42-01-4. ACFT OK FOR SERVICE.SDR IPXA0M63742Light · inoperativeEMERGENCY LIGHTING SYS (CARGO CONFIG) INOP. DEFERRED M440324 ASSIGNED. T/S IAW FIM FAULT TREE 33-51-02-00, BLOCKS 1-3. EMERGENCY EXIT LIGHTS OPS CKS GOOD. THIS CLEARS M440324.SDR IPXA10M63248Lamp · inoperativeEMERGENCY LIGHT INOP IN FILGHT DECK CEILING. RELAMPED, OPS CK GOOD IAW MM 33-52-00.SDR IPXA10M63247Lamp · inoperativeEMERGENCY LIGHTS AT L1 DOOR INOP. RELAMPED L1 EMERGENCY LIGHTS IN DOOR JAMB IAW MM 33-52-01.SDR IPXA10M62868Skin · dentedINSPECTION TYPE:2C, LT WING INBD FLAP UPPER SKIN SURFACE IS DENTED, CREASED REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR DOULBER IAW SRM 57-00-01, REPAIR 1, FIG 201.SDR IPXA10M62870Doubler · crackedINSPECTION TYPE:2C, RT WING L/E WEB HAS CRACK AT 3 EA RIVET MOUNTING HOLE ACCESS THROUGH PANEL 619DB. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR FILLER, DOUBLER, AND ANGLES IAW MD-11 SRM 57-40-02, REPAIR 9 FIG. 203SDR IPXA10M62869Doubler · crackedINSPECTION TYPE:2C, LT WING L/E COMPARTMENT HAS A CRACK AT FASTENER ON CEILING DOUBLER AT XOS 627. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR FILLER, DOUBLER, AND ANGLES IAW SRM 57-40-02, REPAIR 9, FIG 203.SDR IPXA10M62909Floorbeam · damagedINSPECTION TYPE:2C, DEFERRED ITEM: D-412982: MAIN DECK FLOOR SUPPORT BEAM REPAIR. REMOVED DAMAGE, FABRICATED AIND INSTALED FILLER, REPLACEMENT T-ANGLE IAW STA-SA EA 011-5310-01-A2695 I/R AND EO MD11-5310-39940-A.SDR IPXA10M58939Dimmer · burnedAT 1+20, INTO THE FLIGHT, CREW SMELLED STRONG ELECTRICAL SMELL IN COCKPIT. NOTICED ALL OVERHEAD LIGHTING (BACKLIGHT) WAS OUT AND COULD NOT RECOVER LIGHTING. AFTER 20 MIN SMELL WENT AWAY, NO LIGHTS. FOUND OVERHEAD LIGHTING DIMMER CONTROL U1-130 AT FAULT. RSDR IPXA09M57930Floor Panel · damagedBULK PIT FLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M57929Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M57928Floor Panel · damagedBULK PIT FLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M57927Floor Panel · damagedBULK PIT FLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M57926Floor Panel · damagedBULK PIT FLOOR DAMAGED. REPAIRED PER EO MD11-5320-27382-A.SDR IPXA09M57925Floor Panel · damagedBULK PIT FLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M57924Floor Panel · damagedBULK PIT FLOOR PANEL DAMAGED. REPAIRED PER EO MD11-5320-27386-A.SDR IPXA09M56888Indicator · faultyINSPECTION TYPE:N/A L1 DOOR SLIDE PSI IND ON ALL THE TIME WHEN THE DOOR IS CLOSED. REPLACED IND ASSY IAW MM 25-61-04-4. CHECKS GOOD.SDR IPXA09M56845Battery · dischargedINSPECTION TYPE:N/A EVACUATION SLIDE ON L1 DOOR INOP. REMOVED AND REPLACED BATTERIES. OPS TEST SATISFACTORY PER AMM CH 25-61-04.SDR IPXA09M56466Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQ 273-P2-01 EXTERNAL REPAIR DOUBLER ON NR 2 ENGINE PYLON RT SIDE BETWEEN STA YID558-913 AND 562-913 NOT CORRELATED TO SRM REPAIR. REMOVED EXISTING REPAIR FROM NR 2 PYLON LOWER AFT SECTION SKIN AT STA ZPTN2 36.270, FABRICATEDSDR IPXA09M56460Floorbeam · damagedINSPECTION TYPE:1/C TRANSFERRED FROM LOG PAGE 878165 / 1, REF D-395438, MAIN DECK FLOORBEAM LWR FLANGE INTERIM REPAIR. FABBED AND INSTALLED REPAIR DOUBLER IAW IPXA EO MD11-5310-32429-A AND SAA EA 011-5310-01-A1855, REF RCD 344928.SDR IPXA09M56463Slat · damagedINSPECTION TYPE:1/C REMOVED NR 8 SLAT ASSEMBLY P/N NRB6737-501, S/N 48497 FOR REPAIR AND INSTALLATION OF FASTENERS. REPAIRED NR 8 SLAT IAW IPXA EO MD11-5750-33838-B, SAA EA 011-5745-01-A1 834 REV A. REF IPXA RCD 344904.SDR IPXA09M56470Bulkhead · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQUENCE 273-F2-02 INTERNAL DOUBLER REPAIR ON AFT BODY PRESSURE BULKHEAD STA 2007 BETWEEN LBL 46 AND LBL 50 LOWER SIDE NOT CORRELATED TO SRM REPAIR. REMOVED DOUBLER, FABRICATED AND INSTALLED REPAIR DOUBLERS IAW IPXA EO MD11-53SDR IPXA09M56459Bulkhead · misrepairedINSPECTION TYPE:1/C REPAIR SURVEY SEQUENCE 273-F2-03 EXTERNAL REPAIR DOUBLER ON CLG AFT BULKHEAD STA 1521 BETWEEN BL 0 AND LBL 8 NOT CORRELATED TO SRM. REMOVED ORIGINAL DOUBLER AND FABBED AND INSTALLED REPAIR DOUBLER IAW SA A EA 011-5330-01-A1853, AND IPXA EOSDR IPXA09M56458Slat · damagedINSPECTION TYPE:1/C REMOVED NR 8 SLAT ASSEMBLY FOR REPAIR AND INSTALLATION OF FASTENERS. REPAIRED NR 8 SLAT IAW IPXA EO MD11-5745-01-A1834, SAA EA 011-5745-01-A1 834. REF RCD 344904.SDR IPXA09M56469Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQUENCE 273-F1-01 EXTERNAL SKIN DOUBLER REPAIR BETWEEN STA 1921 AND STA 1926 AND BETWEEN LONGERON 42L AND 44L NOT CORRELATED TO SRM REPAIR. REMOVED REPAIR, FABRICATED AND INSTALLED REPAIR DOUBLER, FILLER, AND TRIPLER IAW IPXASDR IPXA09M56465Skin · misrepairedINSPECTION TYPE:1C RT HORZ STAB L/E HAS L/E SKIN REPAIR THAT DOES NOT CONFORM TO SRM. REPAIRED RT HORZ STAB CENTER L/E AT XFS 240 AND XFS 223 REF EO MD11-55 10-34037-A AND EA 011-5510-01-A1796.SDR IPXA09M56445Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQ 273-W3-02 LT WING FIXED L/E LOWER SKIN BETWEEN STA XDLE330 TO XW344 U SHAPE EXTERNAL DOUBLER NOT PER SRM AND NOT LISTED ON MRCSSR. REMOVED EXISTING REPAIR DOUBLER AT LT WING FIXED L/E LOWER SKIN BETWEEN XDLE 330 AND XW344,SDR IPXA09M56433Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQ 273-W4-01 RT WING INBOARD FLAP UPPER SKIN BETWEEN STA XIFH165.300 TO XIFH183.300 EXTERNAL DOUBLER DOES NOT CORRELATE WITH SRM. REMOVED REPAIR DOUBLER ON RT WING INBOARD FLAP UPPER SKIN AT STA XIFH16 5.300 TO XIFH183.300. SDR IPXA09M56464Pressure Panel · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQ NR 273-F2-01 RT MLG HORZ PRESSURE WEB REPAIR NOT PER SRM NOT ON MRCSSR. REMOVED EXISTING REPAIR AT STA 1501-1521 X=-100 TO X=-109.5, ENLARGED TRIM OUT, FABRICATED REPLACEMENT REPAIR AND INSTALLED REF EO MD11-53 30-34035A ASDR IPXA09M56415Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQUENCE 273-W4-02 RT WING NR 1 SLAT BETWEEN STA XIS 168 TO XIS 207 EXTERNAL DOUBLER .1875 INCH HI-LOKS 3 PLACES SED (SHORT EDGE DISTANCE). REMOVED DOUBLER, FABRICATED AND INSTALLED REPAIR DOUBLER, FILLER, AND STRAP IAW UPS EOSDR UPS08M53714Battery · dischargedINSPECTION TYPE:N/A DURING AS-N FOUND EMERGENCY LIGHT BATTERY NR 1 LOW. REMOVED AND REPLACED NR 1 EMERGENCY BATTERY IAW AMM 33-51-01-4. TEST IAW 33-51-01-700- 802 SATIS.SDR UPS08M53326Light · inoperativeINSPECTION TYPE:PS5 EMERGENCY LIGHT IN FORWARD CREW REST MODULE ABOVE BUNK INOP. RELAMPED AND TESTED PER MM 33-50-00-5.SDR UPS08M52170Pump · failedINSPECTION TYPE:N/A THE NR 1 ENGINE FLAMED OUT ON DESCENT. ATTEMPTED TO RESTART ENGINE TWICE, UNSUCCESSFUL. CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED FUEL PUMP ON NR 1 ENG. PERFORMED LEAK CHECK AND ENG TEST PER AMM 73-12-SDR UPS06M48723Limit Switch · faultyINSPECTION TYPE: N/A UPON CLOSING CABIN DOOR FWD L-RECD ALERT DOOR NOT CLOSED. DEFERRED PER MEL 52-40-1-1 CNTL M338791 REQUIRES REINSPECT BEFORE EACH FLT. PERFORMED T/S IAW AMM 52-70-01 FIG 103 & FOUND CLOSE LIMIT SWITCH AT FAULT. REMOVED AND REPLACED CLOSESDR UPS06M47819Indication Sys · malfunctionedINSPECTION TYPE: N/A CABIN DOOR FWD L INDICATION STAYS ON AFTER DOOR IS CLOSED SECURED SLIDE COVER TO DOOR. OPS CKD DOOR. ALL INDICATIONS NORMALSDR UPS06M47719Brake · inoperativeUPON TOUCHDOWN LEVEL 2 AUTOBRAKE FAIL. NO AUTOBRAKES. WENT TO MANUAL ALL WORKED FINE. DISARMED AUTO BRAKE AND LEVEL 2 WENT AWAY. REVIEW ABSCU ON CFDS. NO FAULTS NOTED.SDR UPS06M47286Light · brokenINSPECTION TYPE:N/A, RIGHT DOOR SLIDE TEST LIGHT BROKEN. DFRD ITEM PER MEL 25-61-2 M328551. REPLACED RIGHT ENTRY DOOR PRESS TO TEST LIGHT ASSY. OPS CHECK GOOD. M328551 CLOSED.SDR UPS06M47172Control Panel · faultyINSPECTION TYPE:N/A EMERGENCY POWER LIGHTS INOP. R&R ELECTRICAL SYS CONTROL PANEL AS PER AMM 24-08-02-4.SDR UPS06M46206Indicator · reads lowINSPECTION TYPE:PS2, THE CREW O2 BOTTLE NR 3 READS APPROX 200 PSI LOWER AT THE BOTTLE THAN AT THE REMOTE FLIGHT DECK INDICATOR. THE LIMIT IS 150 PSI DIFFERENCE ACCORDING TO TASK CARD NR 0102. REMOVED AND REPLACED FLIGHT DECK REMOTE O2 IND IAW M/M 35-14-02. SDR UPS06M46205Indicator · reads lowINSPECTION TYPE:PS2, THE CREW O2 BOTTLE NR 4 IS LOW PRESS AT THE BOTTLE AND READS APPROX 200 PSI LESS THAN THE REMOTE FLIGHT DEAC INDICATOR, LIMIT IS 150PSI DIFFERENCE). REMOVED AND REPLACED NR 4 O2 BOTTLE IAW MM CH 35-11-01. REPLACED COCKPI T O2 INDICATOR ISDR UPS06M46204Smoke Goggles · crackedINSPECTION TYPE:PS2, RIGHT CURRIER SEAT SMOKE GOGGLES CRACKED AND STOWAGE POUCH TORN. REPLACED GOGGLES AND POUCH REF IPC 35-11-01SDR UPS05M44934Computer · inoperativeATB - BOTH AUTO PILOTS FAILED SIMULTANEOUSLY. TRIED NUMEROUS TIMES TO RE-ENGAGE, FINALLY ONE OF THEM WAS BACK ON LINE, AND IT LATER FAILED AGAIN REMOVED AND REPLACED NR 2 FCC, BOTH FCC'S PASSED RTS TEST PER MM 22-01-03-4.SDR UPS04M43417Oxygen Mask · failedCAPTAIN OXYGEN MASK WILL NOT RESET PROPERLY. REMOVED AND REPLACED CREW 02 MASK AND STOWAGE BOX IAW 35-13-01. LEAK TEST GOOD.SDR UPS04M43215Bulb · inoperativeR1 ENTRY DOOR SLIDE DISARM LIGHT NEEDS REPLACEMENT LIGHT BULB. REMOVED AND REPLACED, OPS CHECK GOOD.SDR UPS03M41567Detection Sys · malfunctionedDURING APU FIRE TEST NR 2 ENG FIRE HANDLE ILLUMINATED AND WOULD NOT EXTINGUISH. T/S SYS PER FIM 26-11-00 PG 106-111. CLEANED AND SECURED ASSOCIATED CONNECTORS. INSPECTED NR 2 PYLON JUNCTION BOX. NO DEFECTS NOTED IN THIS AREA. OPS CKS GOOD.SDR UPS03M40952Seat Track · corrodedINSPECTION TYPE:C AFT CABIN STA 1964 TO 2007 LT MOST OUTER SEAT TRACK FOUND SURFACE CORROSION AS MARKED. CORROSION REMOVED,SEAT TRACK 1964-2007LBL75.25 IAW SRM53-70-00V1R33. FOUND EXCEEDED LIMIT-ORI THK:0.08 AND REMOVED:0.029. AREA TRIMMED OUT IAW SRM53-70-SDR UPS03M40954Rib · crackedINSPECTION TYPE: C, LT NR 08 SLAT FOUND NR 16 SLAT AT X0S98 WITH I/B RIB CRACK AS MARKED. CRACKED SUPPORT LT NR 8 SLAT XOS98 REMOVED IAW SRM 51-35-01V2.R33. INSTALLED NEW SUPPORT RIB PER SRM 51-35-01 & 51-33-01V.2.R33.
Back to N273UP