N297PQ
Service difficulty reports · 119
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N297PQ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N297PQ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2017120401219Oxygen Mask · deployedFORWARD LAV O2 MASKS DEPLOYED NEED RESECURED
RESTOWED LAV O2 MASK IAW AMM 35-21-17. OK FOR SERVICE.SDR REXA2017110501153Actuator · failedAPU FIRE MASTER WARNING MESSAGE RECIEVED ON GROUND. APU AUTO SHUTDOWN. BOTTLES DID NOT DISCHARGE. TURNED OFF MASTER BATTERY. PERFORMED DOOR RIGGING PROCEDURE IAW AMM 49-14-19. DOOR WILL NOT CLOSE AFTER OPENING. REMOVED AND REPLACED THE APU INLET DOOR ACTUASDR REXA2017100601070Oxygen Mask · inoperativeAFT LAVATORY OXYGEN MASK IS INOPERATIVE. REPACKED AFT LAVATORY PAX OXYGEN MASK. ALL CHECKED GOOD IAW AMM 35-21-17.SDR REXA2017100501064Stowage Box · leakingFIRST OFFICER`S OXYGEN MASK LEAKING. REMOVED & REPLACED THE O2 MASK STOWAGE BOX IAW AMM T.A 35-11-15.SDR REXA2017091701008Acm · seizedCABIN WAS FILLED WITH SMOKE PRIOR TO PUSHBACK WHILE SITTING AT GATE WITH APU RUNNING AND BOTH PACKS SELECTED ON. HAD A L PACK AUTOFAIL CAUTION MSG ALONG WITH L PACK FAULT. OBSERVED DUCT TEM FOR L PACK ABOVE 99 DEGREES C. L PACK FAULT STATUS MSG DUE TO MT023-BSDR REXA2016122602497Oxygen Mask · leakingCAPTAIN`S OXYGEN MASK IS LEAKING AIR WHEN THE MASK CONTAINER DOOR COVER IS OPEN AROUND THE FLOW INDICATOR. REMOVED AND REPLACED THE OXYGEN MASK STOWAGE BOX IAW 35-11-15. OPS CHECK COMPLIED AND PASS IAW 23-51-06. LEAK TEST OF THE CREW OXY SYSTEM IAW 35-10-06.SDR REXA2016100601888Strap · brokenFORWARD STRAP ON FLASHLIGHT IS BROKEN. REPLACED THE STRAP AS REQUIRED IAWAMM 25-61-00SDR REXA2016053100959Light · unsecureJUMP SEAT DOES NOT BOUNCE BACK UP, FLOOR LIGHTING STRIP CAME LOOSE RT SIDE NEXT TO CARTS. INSTALLED EMERGENCY LIGHT STRIP IAW AMM 33-51-01. OK FOR SERVICE.SDR REXA2016040400551Light · inoperativeRIGHT EXTERIOR EMER LIGHT INOPERATIVE. DEFERRED RT EXTERIOR EMER LIGHT IAW MEL 33-51-2A CAT C PLACARD INSTALLED MMO2 UPDATED MOC NOTIFIED 96211. REPLACED RT AFT EXTERIOR EMER LIGHT ASSEMBLY, PN 2LA004305-75, SN OFF 2215934 & SN ON 1066480 IAW AMM 33-51-15. SDR REXA2016031000406Web · crackedPASSENGER DOOR HAS MULTIPLE CRACKS IN FWD & AFT WEBS. CONTINUATION CARD 81529711 OP 71. REPAIRED PAX DOOR AFT WEB IAW EO 670-52-11-104 REV F IAW STEPS 1 - 8 FOR WORK PERFORMED.SDR REXA2016031000405Retainer · damagedFORWARD & CTR BAGGAGE BAY DOORS EACH HAVE DAMAGED SEAL RETAINER AT LOWER INBD, FWD & AFT CORNERS. REPAIRED FWD & CTR CARGO BAY DOOR SEAL RETAINERS. REF STEPS 1 - 2 FOR WORK PERFORMED.SDR REXA2016030900408Housing · crackedMAIN AVI DOOR HANDLE HOUSING HAS 2 EACH CRACK INDICATIONS NOTED AROUND BASE OF SHAFT AT AFT SIDE, 90% FSH. FAILED NDT INSPECTION. CONTINUATION CARD 81529711 OP 74 INSTALLED NEW AVI DOOR HANDLE HOUSING PN 601R31053-3 & SN 1156. REF JOB 8152971 OP 48 STEPS 1 SDR REXA2016030900407Angle · crackedAFT BELLY FAIRING PANEL 195DL, SPLICE ANGLE IS CRACKED. REMOVED CRACKED ANGLE, RECEIVED NEW ANGLE PN CC690-39251-1. PERFORMED EO R53573 REVISION 1, REVISION DATE 29 JAN 16.SDR REXA2015110401053Flashlight · inoperativeFLIGHT ATTENDANT ALT JS FLASHLIGHT IS INOPERATIVE. DEFERRED JS ALT FLASHLIGHT IAW MEL 25-61-4A. ENTERED INMM02 & PLACARD INSTALLED.SDR REXA2015101900931Flashlight · inoperativeFOUND GALLEY FLASHLIGHT INOPERATIVE, RT SIDE OF GALLEY. DEFERRED GALLEY FLASHLIGHT RT SIDE IAW MEL 25-61-4A C. MXC NOTIFIED 96045.SDR REXA2015072600736Battery · dischargedFORWARD FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. R & R FWD NR 2 FLIGHT ATTENDANT FLASHLIGHT BATTERY IAW CMM 25-60-02. OPERATIONS CHECKED GOOD AT THIS TIME.SDR REXA2015062700626Door Seal · leakingEMERGENCY ESCAPE HATCH ON THE FRONT CORNER CLOSER TO CAPTAINS SIDE LEAKS. ALSO, A LEAK ONTO CAPTAINS SIDE CHART CLIP. REMOVED CREW ESCAPE HATCH, INSPECTED OUTER HANDLE SEAL & DOOR TO FUSELAGE SEAL IAW AMM 55-22-07. CLEANED & REAPPLIED LUBRICATION IAW AMM 12SDR REXA2015032200339Trim Panel · defectiveCREW REPORTED WATER LEAK FROM COCKPIT ESCAPE HATCH & ALSO WATER DRIPS FROM OVERHEAD INSTRUMENT PANELS. R & R CREW HATCH OUTER TRIM PANEL IAW 25-16-06. NOTED DAMAGE RT AFT CORNER OF TRIM PANEL, PROBLEM RECTIFIED.SDR REXA2015031400315Unknown · leakingCREW ESCAPE HATCH LEAKING WATER. INSPECTED CREW ESCAPE HATCH AS REQUIRED. DOOR SEAL CONDITION GOOD. ACFT GOOD FOR SERVICE.
Back to N297PQ